Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 8/2017

16.10.2015 | Knee

Mobility of the rotating platform in low contact stress knee arthroplasty is durable

verfasst von: Arthur Zürcher, Kim van Hutten, Jaap Harlaar, Ruud Pöll

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 8/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The mobile bearing or rotating platform (RP) in total knee arthroplasty (TKA) is originally part of a low contact stress (LCS) concept, with bearing undersurface mobility compensating higher bearing upper-surface congruency. The in vivo range of axial femorotibial rotation in RP knees has been the subject of many studies, but always involving the performance of relatively low demanding task conditions. Hardly any study has addressed the maintenance of this rotation over time.

Methods

Two consecutive series of patients with LCS RP knees were studied in a cross-sectional study of 1- and 5-year follow-up. They were assessed using optoelectronic movement analysis during gait and the performance of a sit-to-walk (STW) task with and without turning steps.

Results

A mean range of rotation (SD) was found in the 1-year group of 13.4° (3.7) during gait, 17.8° (6.8) during STW straight, and 17.9° (6.9) during STW with turning. The range in the 5-year group was 11.2° (6.0) during gait, 18.5° (8.7) during STW straight, and 18.3° (8.3) during STW with turning. A so-called paradoxical axial rotation pattern during gait and STW straight occurred in both groups in a normal prevalence.

Conclusion

The amount and pattern of rotation in a LCS RP knee does not become impaired between 1 and 5 years postoperatively. The theoretical benefit of RP TKA has not been proven in any clinical study so far, and studies with suitable long-term follow-up need to prove whether this mobility also leads to improved prosthesis survival. However, our findings support the functioning of the rotating platform at a basal science level and illustrate the need for the use of more complex tasks in kinematic studies.

Level of evidence

Therapeutic study, Level III.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Buechel FF (2004) Mobile-bearing knee arthroplasty: rotation is our salvation! J Arthroplasty 19(Suppl):27–30CrossRefPubMed Buechel FF (2004) Mobile-bearing knee arthroplasty: rotation is our salvation! J Arthroplasty 19(Suppl):27–30CrossRefPubMed
2.
Zurück zum Zitat Callaghan JJ, Insall JN, Greenwald AS, Dennis DA, Komistek RD, Murray DW, Bourne RB, Rorabeck CH, Dorr LD (2001) Mobile-bearing knee replacement: concepts and results. Instr Course Lect 50:431–449PubMed Callaghan JJ, Insall JN, Greenwald AS, Dennis DA, Komistek RD, Murray DW, Bourne RB, Rorabeck CH, Dorr LD (2001) Mobile-bearing knee replacement: concepts and results. Instr Course Lect 50:431–449PubMed
3.
Zurück zum Zitat Callaghan JJ, Wells CW, Liu SS, Goetz DD, Johnston RC (2010) Cemented rotating-platform total knee replacement: a concise follow-up, at a minimum of twenty years, of a previous report. J Bone Joint Surg (Am) 92:1635–1639CrossRef Callaghan JJ, Wells CW, Liu SS, Goetz DD, Johnston RC (2010) Cemented rotating-platform total knee replacement: a concise follow-up, at a minimum of twenty years, of a previous report. J Bone Joint Surg (Am) 92:1635–1639CrossRef
4.
Zurück zum Zitat Carothers JT, Kim RH, Dennis DA, Southworth C (2011) Mobile-bearing total knee arthroplasty. A meta-analysis. J Arthroplasty 26:537–542CrossRefPubMed Carothers JT, Kim RH, Dennis DA, Southworth C (2011) Mobile-bearing total knee arthroplasty. A meta-analysis. J Arthroplasty 26:537–542CrossRefPubMed
5.
Zurück zum Zitat Dalury DF, Pomeroy DL, Gorab RS, Adams MJ (2013) Why are total knee arthroplasties being revised? J Arthroplasty 28(Suppl 1):120–121CrossRefPubMed Dalury DF, Pomeroy DL, Gorab RS, Adams MJ (2013) Why are total knee arthroplasties being revised? J Arthroplasty 28(Suppl 1):120–121CrossRefPubMed
6.
Zurück zum Zitat Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg (Br) 88:1016–2021CrossRef Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg (Br) 88:1016–2021CrossRef
7.
Zurück zum Zitat Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A (2005) Mobile-bearing total knee arthroplasty. Do the polyethylene bearings rotate? Clin Orthop Relat Res 440:88–95CrossRefPubMed Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A (2005) Mobile-bearing total knee arthroplasty. Do the polyethylene bearings rotate? Clin Orthop Relat Res 440:88–95CrossRefPubMed
8.
Zurück zum Zitat Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A (2004) A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res 428:180–189CrossRef Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A (2004) A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res 428:180–189CrossRef
9.
Zurück zum Zitat Fantozzi S, Leardini A, Banks SA, Marcacci M, Giannini S, Catani F (2004) Dynamic in vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 12:144–151CrossRefPubMed Fantozzi S, Leardini A, Banks SA, Marcacci M, Giannini S, Catani F (2004) Dynamic in vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 12:144–151CrossRefPubMed
10.
Zurück zum Zitat Garling EH, Kaptein BL, Nelissen RGHH, Valstar ER (2007) Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis. J Biomech 40(Suppl):25–30CrossRef Garling EH, Kaptein BL, Nelissen RGHH, Valstar ER (2007) Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis. J Biomech 40(Suppl):25–30CrossRef
11.
Zurück zum Zitat Glaister BC, Bernatz GC, Klute GK, Orendurff MS (2007) Video task analysis of turning during activities of daily living. Gait Posture 25:289–294CrossRefPubMed Glaister BC, Bernatz GC, Klute GK, Orendurff MS (2007) Video task analysis of turning during activities of daily living. Gait Posture 25:289–294CrossRefPubMed
12.
Zurück zum Zitat Hofstede SN, Nouta KA, Jacobs W, van Hooff ML, Wymenga AB, Pijls BG, Nelissen RG, Marang-van de Mheen PJ (2015) Mobile bearing vs fixed bearing prostheses for posterior cruciate retaining total knee arthroplasty for postoperatieve functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev 4(2):CD003130 Hofstede SN, Nouta KA, Jacobs W, van Hooff ML, Wymenga AB, Pijls BG, Nelissen RG, Marang-van de Mheen PJ (2015) Mobile bearing vs fixed bearing prostheses for posterior cruciate retaining total knee arthroplasty for postoperatieve functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev 4(2):CD003130
13.
Zurück zum Zitat Hopley CD, Crossett LS, Chen AF (2013) Long-term clinical outcomes and survivorship after total knee arthroplasty using a rotating platform knee prosthesis. J Arthroplasty 28:68–77CrossRefPubMed Hopley CD, Crossett LS, Chen AF (2013) Long-term clinical outcomes and survivorship after total knee arthroplasty using a rotating platform knee prosthesis. J Arthroplasty 28:68–77CrossRefPubMed
14.
Zurück zum Zitat Kim YH, Kim JS, Choe JW, Kim HJ (2012) Long-term comparison of fixed-bearing and mobile-bearing total knee replacements in patients younger than fifty-one years of age with osteoarthritis. J Bone Joint Surg (Am) 94:866–873CrossRef Kim YH, Kim JS, Choe JW, Kim HJ (2012) Long-term comparison of fixed-bearing and mobile-bearing total knee replacements in patients younger than fifty-one years of age with osteoarthritis. J Bone Joint Surg (Am) 94:866–873CrossRef
15.
Zurück zum Zitat Komistek RD, Dennis DA, Mahfouz M (2003) In vivo fluoroscopic analysis of the normal human knee. Clin Orthop Relat Res 410:69–81CrossRef Komistek RD, Dennis DA, Mahfouz M (2003) In vivo fluoroscopic analysis of the normal human knee. Clin Orthop Relat Res 410:69–81CrossRef
16.
Zurück zum Zitat Kwak JY, Jeong JH, Lee SH, Jung HJ, Jung YB (2012) Comparison of the clinical outcomes after total knee arthroplasty with the LCS Rotating Platform Mobile Bearing Knee System and the PFC Sigma RP-F mobile bearing knee system. Clin Orthop Surg 4:256–262CrossRefPubMedPubMedCentral Kwak JY, Jeong JH, Lee SH, Jung HJ, Jung YB (2012) Comparison of the clinical outcomes after total knee arthroplasty with the LCS Rotating Platform Mobile Bearing Knee System and the PFC Sigma RP-F mobile bearing knee system. Clin Orthop Surg 4:256–262CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat LaCour MT, Sharma A, Carr CB, Komistek RD, Dennis DA (2014) Confirmation of long-term in vivo bearing mobility in eight rotating-platform TKAs. Clin Orthop Relat Res 472:2766–2773CrossRefPubMedPubMedCentral LaCour MT, Sharma A, Carr CB, Komistek RD, Dennis DA (2014) Confirmation of long-term in vivo bearing mobility in eight rotating-platform TKAs. Clin Orthop Relat Res 472:2766–2773CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Liu F, Ohdera MH, Wasielewski RC, Komistek RD, Mahfouz MR (2009) In vivo kinematic determination of total knee arthroplasty from squatting to standing. Knee 16:116–120CrossRefPubMed Liu F, Ohdera MH, Wasielewski RC, Komistek RD, Mahfouz MR (2009) In vivo kinematic determination of total knee arthroplasty from squatting to standing. Knee 16:116–120CrossRefPubMed
19.
Zurück zum Zitat Manal K, McClay I, Stanhope S, Richards J, Galinat B (2000) Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: an in vivo study. Gait Posture 11:38–45CrossRefPubMed Manal K, McClay I, Stanhope S, Richards J, Galinat B (2000) Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: an in vivo study. Gait Posture 11:38–45CrossRefPubMed
20.
Zurück zum Zitat Meftah M, Ranawat AS, Ranawat CS (2012) Ten-year follow-up of a rotating-platform, posterior-stabilized total knee arthroplasty. J Bone Joint Surg (Am) 94:426–432CrossRef Meftah M, Ranawat AS, Ranawat CS (2012) Ten-year follow-up of a rotating-platform, posterior-stabilized total knee arthroplasty. J Bone Joint Surg (Am) 94:426–432CrossRef
21.
Zurück zum Zitat Minudo Y, Kobayashi A, Iwaki H, Iwakiri K, Inori F, Sugama R, Ikebuchi M, Yoshinori K, Takaoka K (2009) In vivo analysis of polyethylene wear particles after total knee arthroplasty: the influence of improved materials and designs. J Bone Joint Surg (Am) 91(Suppl 6):67–73CrossRef Minudo Y, Kobayashi A, Iwaki H, Iwakiri K, Inori F, Sugama R, Ikebuchi M, Yoshinori K, Takaoka K (2009) In vivo analysis of polyethylene wear particles after total knee arthroplasty: the influence of improved materials and designs. J Bone Joint Surg (Am) 91(Suppl 6):67–73CrossRef
22.
Zurück zum Zitat Moskal JT, Capps SG (2014) Rotating-platform TKA No different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis. Clin Orthop Relat Res 472:2185–2193CrossRefPubMedPubMedCentral Moskal JT, Capps SG (2014) Rotating-platform TKA No different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis. Clin Orthop Relat Res 472:2185–2193CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Namba R, Graves S, Robertsson O, Furnes O, Stea S, Puig-Verdié L, Hoeffel D, Cafri G, Paxton E, Sedrakyan A (2014) International comparative evaluation of knee replacement with fixed or mobile non-posterior-stabilized implants. J Bone Joint Surg (Am) 96(Suppl 1):52–58CrossRef Namba R, Graves S, Robertsson O, Furnes O, Stea S, Puig-Verdié L, Hoeffel D, Cafri G, Paxton E, Sedrakyan A (2014) International comparative evaluation of knee replacement with fixed or mobile non-posterior-stabilized implants. J Bone Joint Surg (Am) 96(Suppl 1):52–58CrossRef
24.
Zurück zum Zitat Noble PC, Gordon MJ, Weiss JM, Reddix RN, Conditt MA, Mathis KB (2005) Does total knee replacement restore normal knee function? Clin Orthop 431:157–165CrossRef Noble PC, Gordon MJ, Weiss JM, Reddix RN, Conditt MA, Mathis KB (2005) Does total knee replacement restore normal knee function? Clin Orthop 431:157–165CrossRef
25.
Zurück zum Zitat O’Brien S, Spence DJ, Ogonda LO, Beverland DE (2012) LCS mobile bearing total knee arthroplasty without patellar resurfacing. Does the unresurfaced patella affect outcome? Survivorship at a minimum 10-year follow-up. Knee 19:335–338CrossRefPubMed O’Brien S, Spence DJ, Ogonda LO, Beverland DE (2012) LCS mobile bearing total knee arthroplasty without patellar resurfacing. Does the unresurfaced patella affect outcome? Survivorship at a minimum 10-year follow-up. Knee 19:335–338CrossRefPubMed
26.
Zurück zum Zitat Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M (2004) In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res 418:184–190CrossRef Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M (2004) In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res 418:184–190CrossRef
27.
Zurück zum Zitat Shi K, Hayashida K, Umeda N, Yamamoto K, Kawai H (2008) Kinematic comparison between mobile-bearing and fixed-bearing inserts in NexGen legacy posterior stabilized flex total knee arthroplasty. J Arthroplasty 23:164–169CrossRefPubMed Shi K, Hayashida K, Umeda N, Yamamoto K, Kawai H (2008) Kinematic comparison between mobile-bearing and fixed-bearing inserts in NexGen legacy posterior stabilized flex total knee arthroplasty. J Arthroplasty 23:164–169CrossRefPubMed
28.
Zurück zum Zitat Smith H, Jan M, Mahomed NN, Davey JR, Gandhi R (2011) Meta-analysis and systematic review of clinical outcomes comparing mobile bearing and fixed bearing total knee arthroplasty. J Arthroplasty 26:1205–2013CrossRefPubMed Smith H, Jan M, Mahomed NN, Davey JR, Gandhi R (2011) Meta-analysis and systematic review of clinical outcomes comparing mobile bearing and fixed bearing total knee arthroplasty. J Arthroplasty 26:1205–2013CrossRefPubMed
29.
Zurück zum Zitat Smith TO, Ejtehadi F, Nichols R, Davies L, Donell ST, Hing CB (2010) Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 18:325–340CrossRefPubMed Smith TO, Ejtehadi F, Nichols R, Davies L, Donell ST, Hing CB (2010) Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 18:325–340CrossRefPubMed
30.
Zurück zum Zitat Sorrells RB, Capps SG (2006) Clinical results of primary low contact stress cementless total knee arthroplasty. Orthopedics 29(Suppl):42–44 Sorrells RB, Capps SG (2006) Clinical results of primary low contact stress cementless total knee arthroplasty. Orthopedics 29(Suppl):42–44
31.
Zurück zum Zitat Stiehl JB, Dennis DA, Komistek RD, Crane HS (1999) In vivo determination of condylar lift-off and screw-home in a mobile-bearing total knee arthroplasty. J Arthroplasty 14:293–299CrossRefPubMed Stiehl JB, Dennis DA, Komistek RD, Crane HS (1999) In vivo determination of condylar lift-off and screw-home in a mobile-bearing total knee arthroplasty. J Arthroplasty 14:293–299CrossRefPubMed
32.
Zurück zum Zitat Ulivi M, Orlandini L, Meroni V, Consonni O, Sansone V (2015) Survivorship at minimum 10-year follow-up of a rotating-platform, mobile-bearing, posterior-stabilised total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23:1669–1675CrossRefPubMed Ulivi M, Orlandini L, Meroni V, Consonni O, Sansone V (2015) Survivorship at minimum 10-year follow-up of a rotating-platform, mobile-bearing, posterior-stabilised total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 23:1669–1675CrossRefPubMed
33.
Zurück zum Zitat Utzschneider S, Harrasser N, Schroeder C, Mazoochian F, Jansson V (2009) Wear of contemporary total knee replacements. A knee simulator study of six current designs. Clin Biomech 24:583–588CrossRef Utzschneider S, Harrasser N, Schroeder C, Mazoochian F, Jansson V (2009) Wear of contemporary total knee replacements. A knee simulator study of six current designs. Clin Biomech 24:583–588CrossRef
34.
Zurück zum Zitat Vince KG (1993) Principles of condylar knee arthroplasty: issues evolving. Instr Course Lect 42:315–324PubMed Vince KG (1993) Principles of condylar knee arthroplasty: issues evolving. Instr Course Lect 42:315–324PubMed
35.
Zurück zum Zitat Watanabe T, Yamazaki T, Sugamoto K, Tomita T, Hashimoto H, Maeda D, Tamura S, Ochi T, Yoshikawa H (2004) In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion. J Orthop Res 22:1044–1049CrossRefPubMed Watanabe T, Yamazaki T, Sugamoto K, Tomita T, Hashimoto H, Maeda D, Tamura S, Ochi T, Yoshikawa H (2004) In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion. J Orthop Res 22:1044–1049CrossRefPubMed
36.
Zurück zum Zitat Wen Y, Liu D, Huang Y, Li B (2011) A meta-analysis of the fixed-bearing and mobile-bearing prostheses in total knee arthroplasty. Arch Orthop Trauma Surg 131:1341–1350CrossRefPubMed Wen Y, Liu D, Huang Y, Li B (2011) A meta-analysis of the fixed-bearing and mobile-bearing prostheses in total knee arthroplasty. Arch Orthop Trauma Surg 131:1341–1350CrossRefPubMed
37.
Zurück zum Zitat Wolterbeek N, Garling EH, Mertens B, Valstar ER, Nelissen RG (2009) Mobile bearing knee kinematics change over time. A fluoroscopic in rheumatoid arthritis patients. Clin Biomech 24:441–445CrossRef Wolterbeek N, Garling EH, Mertens B, Valstar ER, Nelissen RG (2009) Mobile bearing knee kinematics change over time. A fluoroscopic in rheumatoid arthritis patients. Clin Biomech 24:441–445CrossRef
38.
Zurück zum Zitat Wolterbeek N, Nelissen RGHH, Valstar ER (2012) No differences in in vivo kinematics between six different types of knee prostheses. Knee Surg Sports Traumatol Arthrosc 20:559–564CrossRefPubMed Wolterbeek N, Nelissen RGHH, Valstar ER (2012) No differences in in vivo kinematics between six different types of knee prostheses. Knee Surg Sports Traumatol Arthrosc 20:559–564CrossRefPubMed
39.
Zurück zum Zitat Zürcher AW, van Hutten K, Harlaar J, Terwee CB, Albers GHR (2014) Mobile-bearing total knee arthroplasty: more rotation is evident during more demanding tasks. Knee 21:960–963CrossRefPubMed Zürcher AW, van Hutten K, Harlaar J, Terwee CB, Albers GHR (2014) Mobile-bearing total knee arthroplasty: more rotation is evident during more demanding tasks. Knee 21:960–963CrossRefPubMed
40.
Zurück zum Zitat Zürcher AW, Wolterbeek N, Harlaar J, Pöll RG (2008) Knee rotation during a weightbearing activity: influence of turning. Gait Posture 28:472–477CrossRefPubMed Zürcher AW, Wolterbeek N, Harlaar J, Pöll RG (2008) Knee rotation during a weightbearing activity: influence of turning. Gait Posture 28:472–477CrossRefPubMed
41.
Zurück zum Zitat Zürcher AW, Wolterbeek N, Valstar ER, Nelissen RG, Pöll RG, Harlaar J (2011) The Femoral Epicondylar Frame to track femoral rotation in optoelectronic gait analysis. Gait Posture 33:306–308CrossRefPubMed Zürcher AW, Wolterbeek N, Valstar ER, Nelissen RG, Pöll RG, Harlaar J (2011) The Femoral Epicondylar Frame to track femoral rotation in optoelectronic gait analysis. Gait Posture 33:306–308CrossRefPubMed
Metadaten
Titel
Mobility of the rotating platform in low contact stress knee arthroplasty is durable
verfasst von
Arthur Zürcher
Kim van Hutten
Jaap Harlaar
Ruud Pöll
Publikationsdatum
16.10.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 8/2017
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-015-3823-1

Weitere Artikel der Ausgabe 8/2017

Knee Surgery, Sports Traumatology, Arthroscopy 8/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.