Skip to main content
Erschienen in: Journal of Cardiothoracic Surgery 1/2017

Open Access 01.12.2017 | Case report

Modified ‘candy-plug’ technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

verfasst von: Sohsyu Kotani, Yoshito Inoue, Mio Kasai, Satoru Suzuki, Takashi Hachiya

Erschienen in: Journal of Cardiothoracic Surgery | Ausgabe 1/2017

Abstract

Background

The original ‘candy-plug’ technique has been reported to be beneficial for the treatment of residual perfused false lumen in patients with aortic dissection. However, this technique is also associated with several problems, such as narrowing of the true lumen and damage to the flap or vessel wall. Therefore, we modified the procedure to overcome these problems. Here we report a case in which the patient was successfully treated using the modified procedure.

Case presentation

A 59-year-old man presented with chronic type B aortic dissection with aneurysmal dilatation. The patient had undergone prosthetic graft replacement of the ascending aorta for acute type A aortic dissection 3 years previously and replacement of the descending aorta for residual type B aortic dissection with aneurysmal dilatation 1 year previously. After these procedures, the residual false lumen aneurysm of the distal descending aorta expanded to 57-mm in diameter. Endovascular stent grafting was successfully performed using the modified ‘candy-plug’ technique with relining of the true lumen and occlusion of the false lumen. The patient was discharged 10 days after the procedure. Follow-up imaging at 1 year showed a completely thrombosed false lumen aneurysm.

Conclusion

The modified ‘candy-plug’ technique is useful for treatment of residual type B aortic dissection with aneurysmal dilatation.
Abkürzungen
CTA
Computed tomography angiography
TEVAR
Thoracic endovascular aortic repair

Background

Recently, thoracic endovascular aortic repair (TEVAR) has become a useful operative treatment for complicated chronic type B aortic dissection by covering the primary entry. However, retrograde flow through distal entries or branch vessels makes complete false lumen thrombosis difficult.
Successful exclusion of the false lumen in chronic dissection remains a challenge. Survival is associated with aortic remodelling, which is related to persistence of flow in the false lumen [1].
The original ‘candy-plug’ technique was described for occlusion of a large false lumen aneurysm of the descending aorta using a ‘candy-shaped’ stent-graft [2]. However, endovascular intervention with this technique alone still has two major problems: 1. the possibility of narrowing the true lumen by compression of the ‘candy-plug’ stent [3] and 2. The possibility of flap or vessel wall injury by the stent [3]. To avoid these complications, we designed an efficient modification of the ‘candy-plug’ device, which is deployed adjacent to the distal end of the stent-graft in the true lumen at the same distal end.
Here, we report a case of residual type B chronic aortic dissection with aneurysmal dilatation that was successfully treated using the modified ‘candy-plug’ technique with an Excluder aortic extender after a staged operation for type A aortic dissection.

Case presentation

A 59-year-old man with a medical history of hypertension and smoking was diagnosed with acute type A aortic dissection in 2012. The patient underwent emergency surgery, and prosthetic graft replacement of the ascending aorta was performed. Residual type B aortic dissection with a perfused false lumen aneurysm from the proximal aortic arch to the right iliac artery was followed up by periodic computed tomography angiography (CTA) every 6 months. In 2015, the patient underwent prosthetic graft replacement using a 28-mm Dacron graft (J-Graft SHIELD NEO; Japan Lifeline Co, Ltd., Tokyo, Japan) from the hemi-arch to the descending aorta due to false lumen aneurysm dilatation. Six months after the second procedure, retrograde blood flow persisted through the distal entry in the false lumen, and the dissection with false lumen aneurysm expanded from 47 to 57-mm at its maximum diameter (Fig. 1). It also exhibited a 28-mm false lumen aneurysm and an 8-mm true lumen immediately above the celiac trunk. To dilate the true lumen and occlude the large false lumen, TEVAR was performed using the modified ‘candy-plug’ technique.
Two Conformable TAG stent-grafts (TGU282820J, TGU343420J; W. L. Gore & Associates, Flagstaff, AZ, USA) were selected to deploy in the true lumen. Since proximal diameter was the same as a 28-mm prosthetic graft, a 34*200-mm aortic stent-graft was chosen for proximal true lumen to achieve oversizing by just 20%. The dissection with false lumen aneurysm tapered toward the celiac trunk (8-mm true lumen and 28-mm false lumen), therefore a 28*200-mm aortic stent-graft (two sizes smaller than the proximal device in diameter) was chosen for distal true lumen. Length of thoracic coverage from a 28-mm prosthetic graft to the level of celiac trunk was 168-mm. To keep adequate landing zone, two different size of stent-grafts were required. A 36*45-mm Excluder aortic extender (PLA360400J; W. L. Gore & Associates, Flagstaff, AZ, USA) was chosen for placement of the ‘candy-plug’ in the distal false lumen based on the preoperative CTA results.
This procedure was performed under general anesthesia. To prepare the ‘candy-plug’ device, a 36*45-mm Excluder aortic extender was partially unloaded from the delivery system. To restrict opening of the stent-graft, a 2–0 Ethibond (Ethicon, Somerville, NJ, USA) suture was placed at the middle of the stent-graft, also using a 22-Fr DrySeal Sheath (DSL2228; W. L. Gore & Associates, Flagstaff, AZ, USA) to limit its maximum diameter to 10-mm, producing a shape similar to a wrapped candy (Fig. 2). Then, the stent-graft was reloaded and prepared in a standard manner.
The patient had a false lumen of the left femoral artery and a true lumen of the right femoral artery. First, a Radifocus guidewire (RF-GA35183; Terumo Medical, NJ, USA) was placed through the false lumen via an 8-Fr left femoral sheath, and then a double curve Lunderquist guidewire (TSCMG-35-300-LESDC-JP; Cook Medical, Bloomington, IN, USA) was positioned carefully in exchange for the Radifocus guidewire. Second, a Radifocus guidewire and a double curve Lunderquist guidewire were placed through the true lumen via the right femoral artery in a similar manner. Third, TEVAR was performed via a 24-Fr right femoral sheath. A 28*200-mm Conformable TAG stent-graft was placed in the small true lumen of the descending aorta immediately above the celiac trunk, and then a 34*200-mm Conformable TAG stent-graft was placed at the mid-portion of the 28-mm prosthetic graft of the descending aorta. Next, a customized 36*45-mm Excluder aortic extender was deployed in the large false lumen at the distal end of the 28*200-mm Conformable TAG stent-graft via a 24-Fr left femoral sheath. Finally, a 16-mm Amplatzer Vascular Plug II (9-AVP2–016; AGA Medical Corp., North Plymouth, MN, USA) was placed into the center of the ‘candy-plug’ of the Excluder extender to complete the occlusion. Postprocedural angiography demonstrated no major complications and no residual retrograde flow into the false lumen aneurysm.
The patient was discharged on the 10th postoperative day without any complications.
Follow-up CTA at 1 month post-TEVAR showed no endoleak and almost complete thrombosis of the false lumen above the ‘candy-plug’ device. CTA at 1 year also showed decreased maximum aneurysm diameter (47-mm), greater expansion of the true lumen, and volume reduction of the thrombosed false lumen (Fig. 3).

Discussion

The ‘candy-plug’ technique is a useful treatment option for occlusion of the false lumen in chronic type B aortic dissection. Kölbel et al. originally described this technique using a Zenith TX-2 ProForm stent-graft (Cook Medical, Bloomington, IN, USA) [2]. In this report, the plug was placed in a false lumen in which the true lumen is guarded by a stent-graft. Rholffs et al. reported early results of 18 patients using this ‘candy-plug’ technique for endovascular false lumen occlusion in chronic aortic dissection [4]. They said their technique was feasible and associated with low morbidity and mortality due to its minimal invasiveness [4].
Ogawa et al. recommended using an Excluder aortic extender for the ‘candy-plug’ device instead of the Zenith TX-2 due to the ease of modification [3]. However, they placed it at an unprotected level without a stent-graft in the true lumen. They were also concerned about the possibility of complications caused by the ‘candy-plug’ device. One of the technical problems of the ‘candy-plug’ is the possibility of narrowing the true lumen as the result of expanding the ‘candy-plug’ within the false lumen [3]. This possibility presents the risk of thrombosis of the branch vessels, which are located near the distal entries. Another concern is the possibility of flap or vessel wall injury due to continuous shear stress from the ‘candy-plug’ device [3].
Disproportionate stress from the ‘candy-plug’ device edge has the risk of intimal injury [5]. According to this previous report, the intimal flap is barely stabilized by being sandwiched the embolized false lumen and stented true lumen. We think that a stent-graft in the true lumen should be deployed at the level of distal end of the occluder device in the false lumen.
Our modified ‘candy-plug’ technique with an Excluder aortic extender can reduce the risk of these complications by deploying it adjacent to the distal end of the stent-graft in the true lumen. A stent-graft in the true lumen can avoid narrowing the true lumen and will thus protect the flap from damage by the ‘candy-plug’ device.
We chose 34-mm and 28-mm aortic stent-grafts for the true lumen and a ‘candy-shaped’ 36*45-mm Excluder aortic extender for the false lumen while using a 28-mm prosthetic graft in the descending aorta; the 28-mm false lumen aneurysm and the 8-mm true lumen were located immediately above the celiac trunk. In TEVAR for aortic dissection, the size of stent-graft is determined by the diameter of the proximal landing zone. Generally, 10–20% oversizing of the stent-graft based on the proximal landing zone diameter is recommended. In this case, since proximal diameter was the same as a 28-mm prosthetic graft, a 34*200-mm stent-graft was chosen for proximal true lumen to achieve oversizing by just 20%. The dissection with false lumen aneurysm tapered toward the celiac trunk, therefore a two sizes smaller diameter stent-graft was chosen for distal true lumen. A 36*45-mm Excluder aortic extender was selected because of the easy modification and based on the mean diameter of false lumen which was 31.3-mm. It is difficult to determine the appropriate size of stent-grafts because the thrombosed false lumen will become smaller after ‘candy-plug’ deployment, and the radial force of its frame may increase. Kölbel et al. selected their customized 42-mm TX-2 ProForm stent-graft based on preoperative CTA results, which identified a false lumen diameter < 36-mm. Ogawa et al. based the diameter of their Excluder extender on the mean diameter of the false lumen observed on axial CTA images.
This case had the risk of paraplegia due to long coverage with total false lumen thrombosis. The incidence of symptomatic spinal cord ischemia after TEVAR is ranging between 1 and 5% [6]. Some patients with occluded lower thoracic levels may not suffer from paraplegia whereas others with these segments preserved may well show symptomatic spinal cord ischemia. There are 4 vascular territories supplying the spinal cord (left subclavian, intercostal, lumbar, and hypogastric arteries) and simultaneous closure of some of these vascular territories has association with symptomatic spinal cord injury [6]. We could keep these arteries except intercostal arteries in this case. In addition, we always avoid intraoperative prolonged hypotension. This case didn’t show no sign of paraplegia in the perioperative period.

Conclusion

We performed a successful endovascular repair using the modified ‘candy-plug’ technique for a residual large false lumen aneurysm in the descending aorta. This technique has the potential to effectively occlude large distal false lumen aneurysms within chronic aortic dissection with aneurysmal dilatation.

Acknowledgements

Not applicable.

Funding

The authors declare no funding for this publication.

Availability of data and materials

All data generated or analyzed during this study are included in this published article.
Not applicable.
This patient included in the study consented to participate in research and consent to publish.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Mani K, Clough RE, OTA L, et al. Predictors of outcome after endovascular repair for chronic type B dissection. Eur J Vasc Endovasc Surg. 2012;43:386–91.CrossRefPubMed Mani K, Clough RE, OTA L, et al. Predictors of outcome after endovascular repair for chronic type B dissection. Eur J Vasc Endovasc Surg. 2012;43:386–91.CrossRefPubMed
2.
Zurück zum Zitat Kölbel T, Lohrenz C, Kieback A, et al. Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther. 2013;10:484–9.CrossRef Kölbel T, Lohrenz C, Kieback A, et al. Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther. 2013;10:484–9.CrossRef
3.
Zurück zum Zitat Ogawa Y, Nishimaki H, Chiba K, et al. Candy-plug technique using an excluder aortic extender for distal occlusion of a large false lumen aneurysm in chronic aortic dissection. J Endovasc Ther. 2016;23:483–6.CrossRefPubMed Ogawa Y, Nishimaki H, Chiba K, et al. Candy-plug technique using an excluder aortic extender for distal occlusion of a large false lumen aneurysm in chronic aortic dissection. J Endovasc Ther. 2016;23:483–6.CrossRefPubMed
4.
Zurück zum Zitat Rohlffs F, Tsilimparis N, Fiorucci B, et al. The candy-plug technique: technical aspects and early results of a new endovascular method for false lumen occulusion in chronic aortic dissection. J Endovasc Ther. 2017;24:549–55.CrossRefPubMed Rohlffs F, Tsilimparis N, Fiorucci B, et al. The candy-plug technique: technical aspects and early results of a new endovascular method for false lumen occulusion in chronic aortic dissection. J Endovasc Ther. 2017;24:549–55.CrossRefPubMed
5.
Zurück zum Zitat Furukawa T, Uchida N, Yamane Y, et al. A pitfall of false lumen embolization in chronic aortic dissection: intimal injury caused by the embolization device edge. Interact Cardiovasc Thorac Surg. 2017;24:153–5.CrossRefPubMed Furukawa T, Uchida N, Yamane Y, et al. A pitfall of false lumen embolization in chronic aortic dissection: intimal injury caused by the embolization device edge. Interact Cardiovasc Thorac Surg. 2017;24:153–5.CrossRefPubMed
6.
Zurück zum Zitat Czerny M, Eggebrecht H, Sodeck G, et al. Mechanisms of symptomatic spinal cord ischemia after TEVAR. J Endovasc Ther. 2012;19:37–43.CrossRefPubMed Czerny M, Eggebrecht H, Sodeck G, et al. Mechanisms of symptomatic spinal cord ischemia after TEVAR. J Endovasc Ther. 2012;19:37–43.CrossRefPubMed
Metadaten
Titel
Modified ‘candy-plug’ technique for chronic type B aortic dissection with aneurysmal dilatation: a case report
verfasst von
Sohsyu Kotani
Yoshito Inoue
Mio Kasai
Satoru Suzuki
Takashi Hachiya
Publikationsdatum
01.12.2017
Verlag
BioMed Central
Erschienen in
Journal of Cardiothoracic Surgery / Ausgabe 1/2017
Elektronische ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-017-0647-8

Weitere Artikel der Ausgabe 1/2017

Journal of Cardiothoracic Surgery 1/2017 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Deutlich weniger Infektionen: Wundprotektoren schützen!

08.05.2024 Postoperative Wundinfektion Nachrichten

Der Einsatz von Wundprotektoren bei offenen Eingriffen am unteren Gastrointestinaltrakt schützt vor Infektionen im Op.-Gebiet – und dient darüber hinaus der besseren Sicht. Das bestätigt mit großer Robustheit eine randomisierte Studie im Fachblatt JAMA Surgery.

Chirurginnen und Chirurgen sind stark suizidgefährdet

07.05.2024 Suizid Nachrichten

Der belastende Arbeitsalltag wirkt sich negativ auf die psychische Gesundheit der Angehörigen ärztlicher Berufsgruppen aus. Chirurginnen und Chirurgen bilden da keine Ausnahme, im Gegenteil.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.