Skip to main content
Erschienen in: European Journal of Applied Physiology 5/2011

01.05.2011 | Original Article

Muscle oxygenation of vastus lateralis and medialis muscles during alternating and pulsed current electrical stimulation

verfasst von: Abdulaziz Aldayel, Makii Muthalib, Marc Jubeau, Michael McGuigan, Kazunori Nosaka

Erschienen in: European Journal of Applied Physiology | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

This study compared between alternating and pulsed current electrical muscle stimulation (EMS) for muscle oxygenation and blood volume during isometric contractions. Nine healthy men (23–48 years) received alternating current EMS (2500 Hz) modulated at 75 Hz on the knee extensors of one leg, and pulsed current EMS (75 Hz) for the other leg separated by 2 weeks in a randomised, counter-balanced order. Pulse duration (400 μs), on–off ratio (5–15 s) and other stimulation parameters were matched between conditions and 30 isometric contractions were induced at the knee joint angle of 100° (0° full extension). Changes in tissue oxygenation index (∆TOI) and total hemoglobin volume (∆tHb) of vastus lateralis and medialis muscles over 30 contractions were assessed by a near-infrared spectroscopy, and were compared between conditions by a two-way repeated measures ANOVA. Peak torque produced during EMS increased over 30 contractions in response to the increase in the stimulation intensity for pulsed current, but not for the alternating current EMS. The torque during each isometric contraction was less stable in alternating than pulsed current EMS. The changes in ∆TOI amplitude during relaxation phases and ∆tHb amplitude were not significantly different between conditions. However, the decreases in ∆TOI amplitude during contraction phases from baseline were significantly (P < 0.05) greater for the pulsed current than alternating current from the 18th contraction (−15.6 ± 2.3 vs. −8.9 ± 1.8%) to 30th contraction (−10.7 ± 1.8 vs. −4.8 ± 1.5%). These results suggest that the muscles were less activated in the alternating current EMS when compared with the pulsed current EMS.
Literatur
Zurück zum Zitat Binder-Macleod SA, Halden EE, Jungles KA (1995) Effects of stimulation intensity on the physiological responses of human motor units. Med Sci Sports Exerc 27:556–565PubMed Binder-Macleod SA, Halden EE, Jungles KA (1995) Effects of stimulation intensity on the physiological responses of human motor units. Med Sci Sports Exerc 27:556–565PubMed
Zurück zum Zitat Cettolo V, Ferrari M, Biasini V, Quaresima V (2007) Vastus lateralis O2 desaturation in response to fast and short maximal contraction. Med Sci Sports Exerc 39:1949–1959PubMedCrossRef Cettolo V, Ferrari M, Biasini V, Quaresima V (2007) Vastus lateralis O2 desaturation in response to fast and short maximal contraction. Med Sci Sports Exerc 39:1949–1959PubMedCrossRef
Zurück zum Zitat Chance B, Nioka S, Kent J, McCully K, Fountain M, Greenfeld R, Holtom G (1988) Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle. Anal Biochem 174:698–707PubMedCrossRef Chance B, Nioka S, Kent J, McCully K, Fountain M, Greenfeld R, Holtom G (1988) Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle. Anal Biochem 174:698–707PubMedCrossRef
Zurück zum Zitat Felici F, Quaresima V, Fattorini L, Sbriccoli P, Filligoi GC, Ferrari M (2009) Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises. J Electromyogr Kinesiol 19:e1–e11PubMedCrossRef Felici F, Quaresima V, Fattorini L, Sbriccoli P, Filligoi GC, Ferrari M (2009) Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises. J Electromyogr Kinesiol 19:e1–e11PubMedCrossRef
Zurück zum Zitat Gondin J, Giannesini B, Vilmen C, Dalmasso C, le Fur Y, Cozzone PJ, Bendahan D (2010) Effects of stimulation frequency and pulse duration on fatigue and metabolic cost during a single bout of neuromuscular electrical stimulation. Muscle Nerve 41:667–678PubMed Gondin J, Giannesini B, Vilmen C, Dalmasso C, le Fur Y, Cozzone PJ, Bendahan D (2010) Effects of stimulation frequency and pulse duration on fatigue and metabolic cost during a single bout of neuromuscular electrical stimulation. Muscle Nerve 41:667–678PubMed
Zurück zum Zitat Gorgey AS, Mahoney E, Kendall T, Dudley GA (2006) Effects of neuromuscular electrical stimulation parameters on specific tension. Eur J Appl Physiol 97:737–744PubMedCrossRef Gorgey AS, Mahoney E, Kendall T, Dudley GA (2006) Effects of neuromuscular electrical stimulation parameters on specific tension. Eur J Appl Physiol 97:737–744PubMedCrossRef
Zurück zum Zitat Grimby G, Wigerstad-Lossing I (1989) Comparison of high- and low-frequency muscle stimulators. Arch Phys Med Rehabil 70:835–838PubMed Grimby G, Wigerstad-Lossing I (1989) Comparison of high- and low-frequency muscle stimulators. Arch Phys Med Rehabil 70:835–838PubMed
Zurück zum Zitat Hamaoka T, McCully KK, Quaresima V, Yamamoto K, Chance B (2007) Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans. J Biomed Opt 12:062105PubMedCrossRef Hamaoka T, McCully KK, Quaresima V, Yamamoto K, Chance B (2007) Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans. J Biomed Opt 12:062105PubMedCrossRef
Zurück zum Zitat Hampson NB, Piantadosi CA (1988) Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia. J Appl Physiol 64:2449–2457PubMed Hampson NB, Piantadosi CA (1988) Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia. J Appl Physiol 64:2449–2457PubMed
Zurück zum Zitat Holcomb WR, Golestani S, Hill S (2000) A comparison of knee-extension torque production with biphasic versus Russian current. J Sport Rehabil 9:229–239 Holcomb WR, Golestani S, Hill S (2000) A comparison of knee-extension torque production with biphasic versus Russian current. J Sport Rehabil 9:229–239
Zurück zum Zitat Jubeau M, Sartorio A, Marinone PG, Agosti F, Van Hoecke J, Nosaka K, Maffiuletti NA (2008) Comparison between voluntary and stimulated contractions of the quadriceps femoris for growth hormone response and muscle damage. J Appl Physiol 104:75–81PubMedCrossRef Jubeau M, Sartorio A, Marinone PG, Agosti F, Van Hoecke J, Nosaka K, Maffiuletti NA (2008) Comparison between voluntary and stimulated contractions of the quadriceps femoris for growth hormone response and muscle damage. J Appl Physiol 104:75–81PubMedCrossRef
Zurück zum Zitat Kooistra RD, de Ruiter CJ, de Haan A (2008) Knee angle-dependent oxygen consumption of human quadriceps muscles during maximal voluntary and electrically evoked contractions. Eur J Appl Physiol 102:233–242PubMedCrossRef Kooistra RD, de Ruiter CJ, de Haan A (2008) Knee angle-dependent oxygen consumption of human quadriceps muscles during maximal voluntary and electrically evoked contractions. Eur J Appl Physiol 102:233–242PubMedCrossRef
Zurück zum Zitat Laufer Y, Elboim M (2008) Effect of burst frequency and duration of kilohertz-frequency alternating currents and of low-frequency pulsed currents on strength of contraction, muscle fatigue, and perceived discomfort. Phys Ther 88:1167–1176PubMedCrossRef Laufer Y, Elboim M (2008) Effect of burst frequency and duration of kilohertz-frequency alternating currents and of low-frequency pulsed currents on strength of contraction, muscle fatigue, and perceived discomfort. Phys Ther 88:1167–1176PubMedCrossRef
Zurück zum Zitat Laufer Y, Ries JD, Leininger PM, Alon G (2001) Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms. Phys Ther 81:1307–1316PubMed Laufer Y, Ries JD, Leininger PM, Alon G (2001) Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms. Phys Ther 81:1307–1316PubMed
Zurück zum Zitat Lyons CL, Robb JB, Irrgang JJ, Fitzgerald GK (2005) Differences in quadriceps femoris muscle torque when using a clinical electrical stimulator versus a portable electrical stimulator. Phys Ther 85:44–51PubMed Lyons CL, Robb JB, Irrgang JJ, Fitzgerald GK (2005) Differences in quadriceps femoris muscle torque when using a clinical electrical stimulator versus a portable electrical stimulator. Phys Ther 85:44–51PubMed
Zurück zum Zitat Mackel RG, Brink EE (1995) Accommodation in single human nerve fibers in vivo. Muscle Nerve 18:469–471PubMedCrossRef Mackel RG, Brink EE (1995) Accommodation in single human nerve fibers in vivo. Muscle Nerve 18:469–471PubMedCrossRef
Zurück zum Zitat McCully KK, Hamaoka T (2000) Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle? Exerc Sport Sci Rev 28:123–127PubMed McCully KK, Hamaoka T (2000) Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle? Exerc Sport Sci Rev 28:123–127PubMed
Zurück zum Zitat Owens J, Malone TR (1983) Treatment parameters of high frequency electrical stimulation as established on the Electro-Stim 180. J Orthop Sports Phys Ther 4:162–168PubMed Owens J, Malone TR (1983) Treatment parameters of high frequency electrical stimulation as established on the Electro-Stim 180. J Orthop Sports Phys Ther 4:162–168PubMed
Zurück zum Zitat Quaresima V, Lepanto R, Ferrari M (2003) The use of near infrared spectroscopy in sports medicine. J Sports Med Phys Fitness 43:1–13PubMed Quaresima V, Lepanto R, Ferrari M (2003) The use of near infrared spectroscopy in sports medicine. J Sports Med Phys Fitness 43:1–13PubMed
Zurück zum Zitat Robertson V, Ward AR, Low J, Reed A (2006) Electrotherapy explained: principles and practice. Butterworth-Heinemann Ltd, London Robertson V, Ward AR, Low J, Reed A (2006) Electrotherapy explained: principles and practice. Butterworth-Heinemann Ltd, London
Zurück zum Zitat Rooney JG, Currier DP, Nitz AJ (1992) Effect of variation in the burst and carrier frequency modes of neuromuscular electrical stimulation on pain perception of healthy subjects. Phys Ther 72:800–806 discussion 807–809PubMed Rooney JG, Currier DP, Nitz AJ (1992) Effect of variation in the burst and carrier frequency modes of neuromuscular electrical stimulation on pain perception of healthy subjects. Phys Ther 72:800–806 discussion 807–809PubMed
Zurück zum Zitat Sadamoto T, Bonde-Petersen F, Suzuki Y (1983) Skeletal muscle tension, flow, pressure, and EMG during sustained isometric contractions in humans. Eur J Appl Physiol Occup Physiol 51:395–408PubMedCrossRef Sadamoto T, Bonde-Petersen F, Suzuki Y (1983) Skeletal muscle tension, flow, pressure, and EMG during sustained isometric contractions in humans. Eur J Appl Physiol Occup Physiol 51:395–408PubMedCrossRef
Zurück zum Zitat Selkowitz DM (1985) Improvement in isometric strength of the quadriceps femoris muscle after training with electrical stimulation. Phys Ther 65:186–196PubMed Selkowitz DM (1985) Improvement in isometric strength of the quadriceps femoris muscle after training with electrical stimulation. Phys Ther 65:186–196PubMed
Zurück zum Zitat Sieck GC, Prakash YS (1995) Fatigue at the neuromuscular junction. Branch point vs. presynaptic vs. postsynaptic mechanisms. Adv Exp Med Biol 384:83–100PubMed Sieck GC, Prakash YS (1995) Fatigue at the neuromuscular junction. Branch point vs. presynaptic vs. postsynaptic mechanisms. Adv Exp Med Biol 384:83–100PubMed
Zurück zum Zitat Snyder-Mackler L, Garrett M, Roberts M (1989) A comparison of torque generating capabilities of three different electrical stimulating currents. J Orthop Sports Phys Ther 10:297–301PubMed Snyder-Mackler L, Garrett M, Roberts M (1989) A comparison of torque generating capabilities of three different electrical stimulating currents. J Orthop Sports Phys Ther 10:297–301PubMed
Zurück zum Zitat Snyder-Mackler L, Delitto A, Stralka SW, Bailey SL (1994) Use of electrical stimulation to enhance recovery of quadriceps femoris muscle force production in patients following anterior cruciate ligament reconstruction. Phys Ther 74:901–907PubMed Snyder-Mackler L, Delitto A, Stralka SW, Bailey SL (1994) Use of electrical stimulation to enhance recovery of quadriceps femoris muscle force production in patients following anterior cruciate ligament reconstruction. Phys Ther 74:901–907PubMed
Zurück zum Zitat Stefanovska A, Vodovnik L (1985) Change in muscle force following electrical stimulation. Dependence on stimulation waveform and frequency. Scand J Rehabil Med 17:141–146PubMed Stefanovska A, Vodovnik L (1985) Change in muscle force following electrical stimulation. Dependence on stimulation waveform and frequency. Scand J Rehabil Med 17:141–146PubMed
Zurück zum Zitat Suzuki S, Takasaki S, Ozaki T, Kobayashi Y (1999) Tissue oxygenation monitor using NIR spatially resolved spectroscopy. In: Britton C, Robert RA, Bruce JT (eds) SPIE, pp 582–592 Suzuki S, Takasaki S, Ozaki T, Kobayashi Y (1999) Tissue oxygenation monitor using NIR spatially resolved spectroscopy. In: Britton C, Robert RA, Bruce JT (eds) SPIE, pp 582–592
Zurück zum Zitat Ward AR (2009) Electrical stimulation using kilohertz-frequency alternating current. Phys Ther 89:181–190PubMedCrossRef Ward AR (2009) Electrical stimulation using kilohertz-frequency alternating current. Phys Ther 89:181–190PubMedCrossRef
Zurück zum Zitat Ward AR, Robertson VJ (2000) The variation in fatigue rate with frequency using kHz frequency alternating current. Med Eng Phys 22:637–646PubMedCrossRef Ward AR, Robertson VJ (2000) The variation in fatigue rate with frequency using kHz frequency alternating current. Med Eng Phys 22:637–646PubMedCrossRef
Zurück zum Zitat Ward AR, Shkuratova N (2002) Russian electrical stimulation: the early experiments. Phys Ther 82:1019–1030PubMed Ward AR, Shkuratova N (2002) Russian electrical stimulation: the early experiments. Phys Ther 82:1019–1030PubMed
Metadaten
Titel
Muscle oxygenation of vastus lateralis and medialis muscles during alternating and pulsed current electrical stimulation
verfasst von
Abdulaziz Aldayel
Makii Muthalib
Marc Jubeau
Michael McGuigan
Kazunori Nosaka
Publikationsdatum
01.05.2011
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 5/2011
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1699-9

Weitere Artikel der Ausgabe 5/2011

European Journal of Applied Physiology 5/2011 Zur Ausgabe

Neu im Fachgebiet Arbeitsmedizin

Elterliches Belastungserleben, Unaufmerksamkeits‑/Hyperaktivitätssymptome und elternberichtete ADHS bei Kindern und Jugendlichen: Ergebnisse aus der KiGGS-Studie

Open Access ADHS Leitthema

Die Aufmerksamkeitsdefizit‑/Hyperaktivitätsstörung (ADHS) ist eine der häufigsten psychischen Störungen im Kindes- und Jugendalter [ 1 ]. In Deutschland beträgt die Prävalenz einer elternberichteten ADHS-Diagnose bei Kindern und Jugendlichen 4,4 % …

Substanzkonsum und Nutzung von sozialen Medien, Computerspielen und Glücksspielen unter Auszubildenden an beruflichen Schulen

Open Access Leitthema

Die Begrenzung von Schäden durch Substanzkonsum und andere abhängige Verhaltensweisen von Jugendlichen und jungen Erwachsenen ist ein wichtiges Anliegen der öffentlichen Gesundheit. Der Übergang von der Adoleszenz zum jungen Erwachsenenalter ist …

Berufsbelastung und Stressbewältigung von weiblichen und männlichen Auszubildenden

Leitthema

In der Öffentlichkeit wird die berufliche Ausbildung oftmals unter ökonomischen Gesichtspunkten diskutiert: Mit den geburtenstarken Jahrgängen gehen erfahrene Fachkräfte in Rente und von nachfolgenden Generationen rücken zu wenige Arbeitskräfte …

Rauschtrinken in der frühen Adoleszenz

COVID-19 Leitthema

Alkohol ist in Deutschland die mit Abstand am häufigsten konsumierte psychoaktive Substanz. Mehr als 2 Drittel aller Erwachsenen im Alter von 18 bis 64 Jahren (70,5 %) hat 2021 in den letzten 30 Tagen Alkohol konsumiert [ 1 ]. Von diesen …