Abstract

Determination of chloride concentration in sweat is the current diagnostic gold standard for Cystic Fibrosis (CF). Nanoduct® is a new analyzing system measuring conductivity which requires only 3 microliters of sweat and gives results within 30 minutes. The aim of the study was to evaluate the applicability of this system in a clinical setting of three children’s hospitals and borderline results were compared with sweat chloride concentration. Over 3 years, 1,041 subjects were tested and in 946 diagnostic results were obtained. In 95 children, Nanoduct® failed (9.1% failure rate), mainly due to failures in preterm babies and newborns. Assuming 59 mmol/L as an upper limit of normal conductivity, all our 46 CF patients were correctly diagnosed (sensitivity 100%, 95% CI: 93.1–100; negative predicted value 100% (95% CI: 99.6–100) and only 39 non CF’s were false positive (39/900, 4.3%; specificity 95.7%, 95%CI: 94.2–96.9, positive predicted value 54.1% with a 95%CI: 43.4–65.0). Increasing the diagnostic limit to 80 mmol/L, the rate fell to 0.3% (3/900). CF patients had a median conductivity of 115 mmol/L; the non-CF a median of 37 mmol/L. In conclusion, the Nanoduct® test is a reliable diagnostic tool for CF diagnosis: It has a failure rate comparable to other sweat tests and can be used as a simple bedside test for fast and reliable exclusion, diagnosis or suspicion of CF. In cases with borderline conductivity (60–80 mmol/L) other additional methods (determination of chloride and genotyping) are indicated.
Literatur
1.
Zurück zum Zitat Barben J, Ammann RA, Metlagel A, Schöni MH (2005) Conductivity determined by a new sweat analyzer compared with chloride concentrations for the diagnosis of cystic fibrosis. J Pediatr 146:183–188PubMedCrossRef Barben J, Ammann RA, Metlagel A, Schöni MH (2005) Conductivity determined by a new sweat analyzer compared with chloride concentrations for the diagnosis of cystic fibrosis. J Pediatr 146:183–188PubMedCrossRef
2.
Zurück zum Zitat Barben J, Desax MC, Ammann RA, Schöni MH (2005) Limitations of sweat conductivity determinations with Nanoduct analyzing system for rapid sweat testing in patients with cystic fibrosis. Eur Respir J 26:403s, (abstract) Barben J, Desax MC, Ammann RA, Schöni MH (2005) Limitations of sweat conductivity determinations with Nanoduct analyzing system for rapid sweat testing in patients with cystic fibrosis. Eur Respir J 26:403s, (abstract)
3.
Zurück zum Zitat Beauchamp M, Lands LC (2005) Sweat-testing: a review of current technical requirements. Pediatr Pulmonol 39:507–511PubMedCrossRef Beauchamp M, Lands LC (2005) Sweat-testing: a review of current technical requirements. Pediatr Pulmonol 39:507–511PubMedCrossRef
4.
Zurück zum Zitat Carter EP, Barrett AD, Heeley AF, Kuzemko JA (1984) Improved sweat test method for the diagnosis of cystic fibrosis. Arch Dis Child 59:919–922PubMedCrossRef Carter EP, Barrett AD, Heeley AF, Kuzemko JA (1984) Improved sweat test method for the diagnosis of cystic fibrosis. Arch Dis Child 59:919–922PubMedCrossRef
5.
Zurück zum Zitat Cystic Fibrosis Foundation CDC (1993) Update 1. In. Bethesda: Cystic Fibrosis Foundation Cystic Fibrosis Foundation CDC (1993) Update 1. In. Bethesda: Cystic Fibrosis Foundation
6.
Zurück zum Zitat Desax MC, Barben J, Hammer J, Ammann RA, Schöni MH (2006) Nanoduct sweat conductivity measurements in 1000 subjects. J Cystic Fibrosis 5:S105, (abstract)CrossRef Desax MC, Barben J, Hammer J, Ammann RA, Schöni MH (2006) Nanoduct sweat conductivity measurements in 1000 subjects. J Cystic Fibrosis 5:S105, (abstract)CrossRef
7.
Zurück zum Zitat Desax MC, Barben J, Hammer J, Ammann RA, Schöni MH (2006) Nanoduct sweat conductivity measurements: a good method for sweat testing in patients with cystic fibrosis. Swiss Med Wkly 136(Suppl 151):38S, (abstract) Desax MC, Barben J, Hammer J, Ammann RA, Schöni MH (2006) Nanoduct sweat conductivity measurements: a good method for sweat testing in patients with cystic fibrosis. Swiss Med Wkly 136(Suppl 151):38S, (abstract)
8.
Zurück zum Zitat di Sant’Agnese PA, Darling RC, Perera GA, Shea E (1953) Abnormal electrolyte composition of sweat in cystic fibrosis of the pancreas: clinical significance and relationship to the disease. Pediatrics 12:549–563 di Sant’Agnese PA, Darling RC, Perera GA, Shea E (1953) Abnormal electrolyte composition of sweat in cystic fibrosis of the pancreas: clinical significance and relationship to the disease. Pediatrics 12:549–563
9.
Zurück zum Zitat Eng W, LeGrys VA, Schechter MS, Laughon MM, Barker PM (2005) Sweat-testing in preterm and full-term infants less than 6 weeks of age. Pediatr Pulmonol 40:64–67PubMedCrossRef Eng W, LeGrys VA, Schechter MS, Laughon MM, Barker PM (2005) Sweat-testing in preterm and full-term infants less than 6 weeks of age. Pediatr Pulmonol 40:64–67PubMedCrossRef
10.
Zurück zum Zitat Funk MJ, LeGrys VA (2005) Testing diagnostic tests: why size matters. J Pediatr 146:159–162PubMedCrossRef Funk MJ, LeGrys VA (2005) Testing diagnostic tests: why size matters. J Pediatr 146:159–162PubMedCrossRef
11.
Zurück zum Zitat Gibson LE, Cooke RE (1959) A test for concentration of electrolytes in sweat in cystic fibrosis of the pancreas utilizing pilocarpine by iontophoresis. Pediatrics 23:545–549PubMed Gibson LE, Cooke RE (1959) A test for concentration of electrolytes in sweat in cystic fibrosis of the pancreas utilizing pilocarpine by iontophoresis. Pediatrics 23:545–549PubMed
12.
Zurück zum Zitat Green A, Elborn S, Fahie-Wilson MN, Kirk JM, Wallis CE, Weller P (2003) Guidelines for the performance of the sweat test for the investigation of cystic fibrosis in the UK. In. http://www.acb.org.uk Green A, Elborn S, Fahie-Wilson MN, Kirk JM, Wallis CE, Weller P (2003) Guidelines for the performance of the sweat test for the investigation of cystic fibrosis in the UK. In. http://​www.​acb.​org.​uk
13.
Zurück zum Zitat Hammond KB, Nelson L, Gibson LE (1994) Clinical evaluation of the macroduct sweat collection system and conductivity analyzer in the diagnosis of cystic fibrosis. J Pediatr 124:255–260PubMedCrossRef Hammond KB, Nelson L, Gibson LE (1994) Clinical evaluation of the macroduct sweat collection system and conductivity analyzer in the diagnosis of cystic fibrosis. J Pediatr 124:255–260PubMedCrossRef
14.
Zurück zum Zitat Heeley ME, Woolf DA, Heeley AF (2000) Indirect measurements of sweat electrolyte concentration in the laboratory diagnosis of cystic fibrosis. Arch Dis Child 82:420–424PubMedCrossRef Heeley ME, Woolf DA, Heeley AF (2000) Indirect measurements of sweat electrolyte concentration in the laboratory diagnosis of cystic fibrosis. Arch Dis Child 82:420–424PubMedCrossRef
16.
Zurück zum Zitat LeGrys VA (1992) Assessing quality assurance for sweat chloride testing. Clin Lab Sci 5:354–357PubMed LeGrys VA (1992) Assessing quality assurance for sweat chloride testing. Clin Lab Sci 5:354–357PubMed
17.
Zurück zum Zitat LeGrys VA, Rosenstein BJ, Doumas BT et al (2000) Sweat testing: sample collection and quantitative analysis; approved Guideline, 2nd edn. C34-A2. National Committee for Clinical Laboratory Standards LeGrys VA, Rosenstein BJ, Doumas BT et al (2000) Sweat testing: sample collection and quantitative analysis; approved Guideline, 2nd edn. C34-A2. National Committee for Clinical Laboratory Standards
18.
Zurück zum Zitat Losty HC, Wheatley H, Doull I (2006) The evaluation of a novel conductmetric device for the diagnosis of cystic fibrosis. Ann Clin Biochem 43:375–381PubMedCrossRef Losty HC, Wheatley H, Doull I (2006) The evaluation of a novel conductmetric device for the diagnosis of cystic fibrosis. Ann Clin Biochem 43:375–381PubMedCrossRef
19.
Zurück zum Zitat Mastella G, Di Cesare G, Borruso A, Menin L, Zanolla L (2000) Reliability of sweat-testing by the Macroduct collection method combined with conductivity analysis in comparison with the classic Gibson and Cooke technique. Acta Paediatr 89:933–937PubMedCrossRef Mastella G, Di Cesare G, Borruso A, Menin L, Zanolla L (2000) Reliability of sweat-testing by the Macroduct collection method combined with conductivity analysis in comparison with the classic Gibson and Cooke technique. Acta Paediatr 89:933–937PubMedCrossRef
20.
Zurück zum Zitat Rosenstein BJ, Cutting GR, for the Cystic Fibrosis Foundation Consensus Panel (1998) The diagnosis of cystic fibrosis: a consensus statement. J Pediatrics 132:589–595CrossRef Rosenstein BJ, Cutting GR, for the Cystic Fibrosis Foundation Consensus Panel (1998) The diagnosis of cystic fibrosis: a consensus statement. J Pediatrics 132:589–595CrossRef
21.
Zurück zum Zitat Webster HL, Quirante CG (2000) Micro-flowcell conductometric sweat analysis for cystic fibrosis diagnosis. Ann Clin Biochem 37:399–407PubMedCrossRef Webster HL, Quirante CG (2000) Micro-flowcell conductometric sweat analysis for cystic fibrosis diagnosis. Ann Clin Biochem 37:399–407PubMedCrossRef
Metadaten
Titel
Nanoduct® sweat testing for rapid diagnosis in newborns, infants and children with cystic fibrosis
verfasst von
Marie-Claire Desax
Roland A. Ammann
Jürg Hammer
Martin H. Schoeni
Jürg Barben
On behalf of the Swiss Paediatric Respiratory Research Group
Publikationsdatum
01.03.2008
Verlag
Springer-Verlag
Erschienen in
European Journal of Pediatrics / Ausgabe 3/2008
Print ISSN: 0340-6199
Elektronische ISSN: 1432-1076
DOI
https://doi.org/10.1007/s00431-007-0485-0

Weitere Artikel der Ausgabe 3/2008

European Journal of Pediatrics 3/2008 Zur Ausgabe

Neuer Typ-1-Diabetes bei Kindern am Wochenende eher übersehen

23.04.2024 Typ-1-Diabetes Nachrichten

Wenn Kinder an Werktagen zum Arzt gehen, werden neu auftretender Typ-1-Diabetes und diabetische Ketoazidosen häufiger erkannt als bei Arztbesuchen an Wochenenden oder Feiertagen.

Neue Studienergebnisse zur Myopiekontrolle mit Atropin

22.04.2024 Fehlsichtigkeit Nachrichten

Augentropfen mit niedrig dosiertem Atropin können helfen, das Fortschreiten einer Kurzsichtigkeit bei Kindern zumindest zu verlangsamen, wie die Ergebnisse einer aktuellen Studie mit verschiedenen Dosierungen zeigen.

Spinale Muskelatrophie: Neugeborenen-Screening lohnt sich

18.04.2024 Spinale Muskelatrophien Nachrichten

Seit 2021 ist die Untersuchung auf spinale Muskelatrophie Teil des Neugeborenen-Screenings in Deutschland. Eine Studie liefert weitere Evidenz für den Nutzen der Maßnahme.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Pädiatrie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.