01.08.2013 | Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

New Software Solutions for Cardiac SPECT Imaging

verfasst von: E. Gordon DePuey

Erschienen in: Current Cardiovascular Imaging Reports | Ausgabe 4/2013

Einloggen, um Zugang zu erhalten

Abstract

Recent advances in myocardial perfusion single photon emission computed tomography (SPECT) processing software, incorporating iterative reconstruction, resolution recovery, and noise compensation, now provide the ability to acquire high quality scans despite reduced administered activity, shortened acquisition time, or both. These methods have thereby provided imaging protocol flexibility and facilitated patient-centered imaging. Other software methods allow for improved image quality by prescribing an image acquisition time that will yield optimal SPECT image count density. On some new solid state cameras list mode acquisition is now available, whereby suboptimal acquisition stops such as those with patient motion can be eliminated prior to SPECT reconstruction. Still other methods, incorporating phase analysis of gated perfusion SPECT, provide a quantitative analysis of left ventricular dyssynchrony, aiding in the selection of patients for whom cardiac resynchronization therapy is most beneficial.
Literatur
1.
Zurück zum Zitat Patton JA, Slomka PJ, Germano G, Berman DS. Recent technological advances in nuclear cardiology. J Nucl Cardiol. 2007;14:501–13.PubMedCrossRef Patton JA, Slomka PJ, Germano G, Berman DS. Recent technological advances in nuclear cardiology. J Nucl Cardiol. 2007;14:501–13.PubMedCrossRef
2.
Zurück zum Zitat • Garcia EV, Faber TL. New trends in camera and software technology in nuclear cardiology. Cardiol Clin. 2009;27:227–36. This review article explains the theory and implementation of new scintillation cameras for myocardial perfusion SPECT and the introduction of new software methods for SPECT reconstruction.PubMedCrossRef • Garcia EV, Faber TL. New trends in camera and software technology in nuclear cardiology. Cardiol Clin. 2009;27:227–36. This review article explains the theory and implementation of new scintillation cameras for myocardial perfusion SPECT and the introduction of new software methods for SPECT reconstruction.PubMedCrossRef
3.
Zurück zum Zitat DePuey EG. New software methods to cope with reduced counting statistics: shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol. 2009;16:335–8.PubMedCrossRef DePuey EG. New software methods to cope with reduced counting statistics: shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol. 2009;16:335–8.PubMedCrossRef
4.
Zurück zum Zitat •• DePuey EG. Advances in SPECT camera software and hardware: currently available and new on the horizon. J Nucl Cardiol. 2012;19:551–81. This review article provides an in-depth explanation of new myocardial perfusion SPECT hardware and software methods and recent clinical results.PubMedCrossRef •• DePuey EG. Advances in SPECT camera software and hardware: currently available and new on the horizon. J Nucl Cardiol. 2012;19:551–81. This review article provides an in-depth explanation of new myocardial perfusion SPECT hardware and software methods and recent clinical results.PubMedCrossRef
5.
Zurück zum Zitat Metz CE. The geometric transfer function component for scintillation camera collimators with straight parallel holes. Phys Med Biol. 1980;25:1059–70.PubMedCrossRef Metz CE. The geometric transfer function component for scintillation camera collimators with straight parallel holes. Phys Med Biol. 1980;25:1059–70.PubMedCrossRef
6.
Zurück zum Zitat Tsui BMW, Gullberg GT. The geometric transfer-function for cone and fan beam collimators. Phys Med Biol. 1990;35:81–93.PubMedCrossRef Tsui BMW, Gullberg GT. The geometric transfer-function for cone and fan beam collimators. Phys Med Biol. 1990;35:81–93.PubMedCrossRef
7.
Zurück zum Zitat Tsui BMW, Hu HB, Gillard DR, Gullberg GT. Implementation of simultaneous attenuation and detector response correction in SPECT. IEEE Trans Nucl Sci. 1988;35:778–83.CrossRef Tsui BMW, Hu HB, Gillard DR, Gullberg GT. Implementation of simultaneous attenuation and detector response correction in SPECT. IEEE Trans Nucl Sci. 1988;35:778–83.CrossRef
8.
Zurück zum Zitat Tsui BMW, Frey EC, Zhao X, Lalush DS, Johnston RE, McCartney WH. The importance and implementation of accurate 3-dimensional compensation methods for quantitative SPECT. Phys Med Biol. 1994;39:509–30.PubMedCrossRef Tsui BMW, Frey EC, Zhao X, Lalush DS, Johnston RE, McCartney WH. The importance and implementation of accurate 3-dimensional compensation methods for quantitative SPECT. Phys Med Biol. 1994;39:509–30.PubMedCrossRef
9.
Zurück zum Zitat Tsui BMW, Zhao XD, Frey EC, Gullberg GT. Characteristics of reconstructed point response in 3-dimensional spatially variant detector response compensation in SPECT. In: Grangeat P, Amans J-L, editors. Three-dimensional image reconstruction in radiology and nuclear medicine. Kluwer. Dordrecht: Academic Publishers; 1996. p. 509–30. Tsui BMW, Zhao XD, Frey EC, Gullberg GT. Characteristics of reconstructed point response in 3-dimensional spatially variant detector response compensation in SPECT. In: Grangeat P, Amans J-L, editors. Three-dimensional image reconstruction in radiology and nuclear medicine. Kluwer. Dordrecht: Academic Publishers; 1996. p. 509–30.
10.
Zurück zum Zitat Borges-Neto S, Pagnanelli RA, Shaw LK, Honeycutt E, Shwartz SC, Adams GL, et al. Clinical results of a novel wide beam reconstruction method for shortenings can time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol. 2007;14:555–65.PubMedCrossRef Borges-Neto S, Pagnanelli RA, Shaw LK, Honeycutt E, Shwartz SC, Adams GL, et al. Clinical results of a novel wide beam reconstruction method for shortenings can time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol. 2007;14:555–65.PubMedCrossRef
11.
Zurück zum Zitat Venero CV, Heller GV, Bateman TM, McGhie AI, Ahlberg AW, Katten D, et al. A multicenter evaluation of a new postprocessing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction. J Nucl Cardiol. 2009;16:714–25.PubMedCrossRef Venero CV, Heller GV, Bateman TM, McGhie AI, Ahlberg AW, Katten D, et al. A multicenter evaluation of a new postprocessing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction. J Nucl Cardiol. 2009;16:714–25.PubMedCrossRef
12.
Zurück zum Zitat DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz SC. Ordered subset expectation that maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison with "full-time" filtered backprojection. J Nucl Cardiol. 2008;15:547–63.PubMedCrossRef DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz SC. Ordered subset expectation that maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison with "full-time" filtered backprojection. J Nucl Cardiol. 2008;15:547–63.PubMedCrossRef
13.
Zurück zum Zitat DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y. Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison with “full-time” ordered subset expectation maximum. J Nucl Cardiol. 2009;16:736–52.PubMedCrossRef DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y. Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison with “full-time” ordered subset expectation maximum. J Nucl Cardiol. 2009;16:736–52.PubMedCrossRef
14.
Zurück zum Zitat DePuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M. A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT. J Nucl Cardiol. 2011;18:273–80.PubMedCrossRef DePuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M. A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT. J Nucl Cardiol. 2011;18:273–80.PubMedCrossRef
15.
Zurück zum Zitat Chen J, Garcia EV, Folks RD, Cooke CD, Faber TL, Tauxe L, et al. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12:687–95.PubMedCrossRef Chen J, Garcia EV, Folks RD, Cooke CD, Faber TL, Tauxe L, et al. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12:687–95.PubMedCrossRef
16.
Zurück zum Zitat Henneman MM, Chen J, Dibbets-Schneider P, Stokkel MP, Bleeker GB, Ypenburg C, et al. Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT? J Nucl Med. 2007;48:1104–11.PubMedCrossRef Henneman MM, Chen J, Dibbets-Schneider P, Stokkel MP, Bleeker GB, Ypenburg C, et al. Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT? J Nucl Med. 2007;48:1104–11.PubMedCrossRef
17.
Zurück zum Zitat Esteves FP, Raggi P, Folks RD, Keidar Z, Askew W, Rispler S, et al. Novel solid- state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927–34.PubMedCrossRef Esteves FP, Raggi P, Folks RD, Keidar Z, Askew W, Rispler S, et al. Novel solid- state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927–34.PubMedCrossRef
18.
Zurück zum Zitat Erlandsson K, Kacperski K, Van Gramberg D, Hutton B. Performance evaluation of D-SPECT: a novel dedicated cardiac SPECT scanner. Phys Med Biol. 2009;54:2635–2649.PubMedCrossRef Erlandsson K, Kacperski K, Van Gramberg D, Hutton B. Performance evaluation of D-SPECT: a novel dedicated cardiac SPECT scanner. Phys Med Biol. 2009;54:2635–2649.PubMedCrossRef
19.
Zurück zum Zitat Hutton B, Erlandsson K, Kacperski K, Van Gramberg D, Roth N. Performance evaluation of D-SPCT: a novel dedicated cardiac SPECT scanner. J Nucl Med. 2008;49 Suppl 1:124P. Hutton B, Erlandsson K, Kacperski K, Van Gramberg D, Roth N. Performance evaluation of D-SPCT: a novel dedicated cardiac SPECT scanner. J Nucl Med. 2008;49 Suppl 1:124P.
20.
Zurück zum Zitat Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, et al. High-speed myocardial perfusion imaging: initial clinical comparison with conventional dual detector anger camera imaging. J Am Coll Cardiol Imaging. 2008;1:156–63.CrossRef Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, et al. High-speed myocardial perfusion imaging: initial clinical comparison with conventional dual detector anger camera imaging. J Am Coll Cardiol Imaging. 2008;1:156–63.CrossRef
21.
Zurück zum Zitat Sharir T, Slomka PJ, Hayes SW, DiCarli MF, Ziffer JA, Martin WH, et al. Multicenter trial of high-speed vs conventional single-photon emission computed tomography imaging: quantitative of myocardial perfusion and left ventricular function. J Am Coll Cardiol. 2010;55:1965–74.PubMedCrossRef Sharir T, Slomka PJ, Hayes SW, DiCarli MF, Ziffer JA, Martin WH, et al. Multicenter trial of high-speed vs conventional single-photon emission computed tomography imaging: quantitative of myocardial perfusion and left ventricular function. J Am Coll Cardiol. 2010;55:1965–74.PubMedCrossRef
22.
Zurück zum Zitat Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT/CT [abstract]. J Nucl Med. 2010;4(Suppl):733. Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT/CT [abstract]. J Nucl Med. 2010;4(Suppl):733.
23.
Zurück zum Zitat Maddahi J, Mendez R, Mahmarian J, Thomas G, Bai C, Babla H, et al. Prospective multicenter evaluation of rapid gated SPECT myocardial perfusion and upright imaging. J Nucl Cardiol. 2009;16:351–7.PubMedCrossRef Maddahi J, Mendez R, Mahmarian J, Thomas G, Bai C, Babla H, et al. Prospective multicenter evaluation of rapid gated SPECT myocardial perfusion and upright imaging. J Nucl Cardiol. 2009;16:351–7.PubMedCrossRef
24.
Zurück zum Zitat Duvall WL, Croft LB, Godiwala T, Ginsberg E, George T, Henzlova MJ. Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera. J Nucl Cardiol. 2010;17:1009–14.PubMedCrossRef Duvall WL, Croft LB, Godiwala T, Ginsberg E, George T, Henzlova MJ. Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera. J Nucl Cardiol. 2010;17:1009–14.PubMedCrossRef
Metadaten
Titel
New Software Solutions for Cardiac SPECT Imaging
verfasst von
E. Gordon DePuey
Publikationsdatum
01.08.2013
Verlag
Springer US
Erschienen in
Current Cardiovascular Imaging Reports / Ausgabe 4/2013
Print ISSN: 1941-9066
Elektronische ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-013-9204-6

Weitere Artikel der Ausgabe 4/2013

Current Cardiovascular Imaging Reports 4/2013 Zur Ausgabe

Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

Pharmacologic Stress Agents for Cardiac Imaging

Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

State of the Art in Cardiac Hybrid Technology: PET/MR

Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

State of the Art Hybrid Technology: SPECT/CT

Cardiac Nuclear Imaging (A Cuocolo, Section Editor)

New Hardware Solutions for Cardiac SPECT Imaging

Triglyzeridsenker schützt nicht nur Hochrisikopatienten

10.05.2024 Hypercholesterinämie Nachrichten

Patienten mit Arteriosklerose-bedingten kardiovaskulären Erkrankungen, die trotz Statineinnahme zu hohe Triglyzeridspiegel haben, profitieren von einer Behandlung mit Icosapent-Ethyl, und zwar unabhängig vom individuellen Risikoprofil.

Gibt es eine Wende bei den bioresorbierbaren Gefäßstützen?

In den USA ist erstmals eine bioresorbierbare Gefäßstütze – auch Scaffold genannt – zur Rekanalisation infrapoplitealer Arterien bei schwerer PAVK zugelassen worden. Das markiert einen Wendepunkt in der Geschichte dieser speziellen Gefäßstützen.

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.