Abstract

Background

There are many factors involved in a difficult colonoscopy. Our hypothesis is that colonic intubation is more difficult in thin patients. We consider it beneficial to know a priori who would be in need of specialized equipment or maneuvers for a successful colonoscopy.

Methods

Over two years, 435 consecutive patients who underwent elective colonoscopy by one surgeon were included in this prospective study. Patients who underwent prior colectomy, who had cancer other than that of the cecum, or who had had an emergent endoscopy were excluded from the study. The time it took to insert the colonoscope from the anus to the cecum was recorded and rounded to the nearest minute. For statistical analysis, we considered gender, age, body mass index (BMI), abdominal girth, diagnosis, presence or absence of prior pelvic surgery, need for external compression, and quality of the bowel preparation. The Mann-Whitney test was used to compare the median time of intubation between males and females.

Results

There was no statistically significant correlation between the BMI, abdominal girth, presence or absence of prior abdominal or pelvic surgery, and the length of insertion of the endoscope. Statistical significance was reached between the male and female. The median time to insert the colonoscope in the males was 7 min (mean = 8.14 min), while in females it was 10 min (mean = 10.6 min).

Conclusions

Females had a significantly longer time of insertion of the colonoscope compared to males. Neither abdominal girth nor body mass seems to reflect the volume of the peritoneal cavity. It seems possible that there is a content-container mismatch in thin female patients. We suggest repeating the study using other anthropometric measurements to calculate the intraperitoneal volume. This may help select the patients who would benefit from a deeper sedation or more specialized equipment.
Literatur
1.
Zurück zum Zitat Anderson JC, Gonzalez JD, Messina CR, Pollack BJ (2000) Factors that predict incomplete colonoscopy: thinner is not always better. Am J Gastroenterol 95: 2784–2787PubMedCrossRef Anderson JC, Gonzalez JD, Messina CR, Pollack BJ (2000) Factors that predict incomplete colonoscopy: thinner is not always better. Am J Gastroenterol 95: 2784–2787PubMedCrossRef
2.
Zurück zum Zitat Chak A, Cooper GS, Blades EW, Canto M, Sivak MV (1996) Prospective assessment of colonoscopic intubation skills in trainees. Gastrointest Endosc 44: 54–57PubMedCrossRef Chak A, Cooper GS, Blades EW, Canto M, Sivak MV (1996) Prospective assessment of colonoscopic intubation skills in trainees. Gastrointest Endosc 44: 54–57PubMedCrossRef
3.
Zurück zum Zitat Church JM (1994) Complete colonoscopy: How often? And if not? Why not? Am J Gastroenterol 89: 556–556PubMed Church JM (1994) Complete colonoscopy: How often? And if not? Why not? Am J Gastroenterol 89: 556–556PubMed
4.
Zurück zum Zitat Cirocco WC, Rusin LC (1995) Factors that predict incomplete colonoscopy. Dis Colon Rectum 38: 964–968PubMedCrossRef Cirocco WC, Rusin LC (1995) Factors that predict incomplete colonoscopy. Dis Colon Rectum 38: 964–968PubMedCrossRef
5.
Zurück zum Zitat Horiuchi A, Nakayama Y, Kajiyama M, Fujii H, Tanaka N (2004) Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy. Am J Gastroenterol 99: 1936–1940PubMedCrossRef Horiuchi A, Nakayama Y, Kajiyama M, Fujii H, Tanaka N (2004) Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy. Am J Gastroenterol 99: 1936–1940PubMedCrossRef
6.
Zurück zum Zitat Ness RM, Gottlieb K, Rex DK, Lehman GA (1996) Difficult sigmoid colon intubation: guide wire exchange technique. Gastrointest Endosc 44: 99–101PubMedCrossRef Ness RM, Gottlieb K, Rex DK, Lehman GA (1996) Difficult sigmoid colon intubation: guide wire exchange technique. Gastrointest Endosc 44: 99–101PubMedCrossRef
7.
Zurück zum Zitat Rex DK (2002) Speeding up cecal intubation: Its role in the efficiency of colonoscopy delivery. Am J Gastroenterol 97: 6–8PubMedCrossRef Rex DK (2002) Speeding up cecal intubation: Its role in the efficiency of colonoscopy delivery. Am J Gastroenterol 97: 6–8PubMedCrossRef
8.
Zurück zum Zitat Rex DK, Goodwine BW (2002) Method of colonoscopy in 42 consecutive patients presenting after prior incomplete colonoscopy. Am J Gastroenterol 97: 1148–1151PubMedCrossRef Rex DK, Goodwine BW (2002) Method of colonoscopy in 42 consecutive patients presenting after prior incomplete colonoscopy. Am J Gastroenterol 97: 1148–1151PubMedCrossRef
9.
Zurück zum Zitat Saifuddin T, Trivedi M, King PD, Madsen R, Marshall JB (2000) Usefulness of a pediatric colonoscope for colonoscopy in adults. Gastrointest Endosc 51: 314–317PubMedCrossRef Saifuddin T, Trivedi M, King PD, Madsen R, Marshall JB (2000) Usefulness of a pediatric colonoscope for colonoscopy in adults. Gastrointest Endosc 51: 314–317PubMedCrossRef
10.
Zurück zum Zitat Saunders BP, Fukumoto M, Halligan S, Jobling C, Moussa ME, Bartram CI, Williams CB (1996) Why is colonoscopy more difficult in women? Gastrointest Endosc 43: 124–126PubMedCrossRef Saunders BP, Fukumoto M, Halligan S, Jobling C, Moussa ME, Bartram CI, Williams CB (1996) Why is colonoscopy more difficult in women? Gastrointest Endosc 43: 124–126PubMedCrossRef
11.
Zurück zum Zitat Waye JD, Bashkoff E (1991) Total colonoscopy: Is it always possible? Gastrointest Endosc 37: 152–154PubMedCrossRef Waye JD, Bashkoff E (1991) Total colonoscopy: Is it always possible? Gastrointest Endosc 37: 152–154PubMedCrossRef
Metadaten
Titel
Patient factors associated with a faster insertion of the colonoscope
verfasst von
Rodolfo Arcovedo
Charles Larsen
Hector Salazar Reyes
Publikationsdatum
01.06.2007
Verlag
Springer-Verlag
Erschienen in
Surgical Endoscopy / Ausgabe 6/2007
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-006-9116-5

Weitere Artikel der Ausgabe 6/2007

Surgical Endoscopy 6/2007 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.