Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 5/2012

01.07.2012 | Original Article

Pedicle screw diameter selection for safe insertion in the thoracic spine

verfasst von: Toru Fujimoto, Akira Sei, Takuya Taniwaki, Tatsuya Okada, Toshitake Yakushiji, Hiroshi Mizuta

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 5/2012

Einloggen, um Zugang zu erhalten

Abstract

Objective

Many thoracic pedicles are too small for the safe acceptance of a transpedicular screw. However, few studies have so far reported on the methods to select a proper pedicle screw size and to confirm the morphologic changes for such a small thoracic spine pedicle. The objective of this work was to determine the potential limits of a pedicle screw diameter for transpedicular screw placement in the thoracic spine.

Methods

T2–T9 vertebrae from eleven patients that underwent posterior thoracic instrumentation with the use of fluoroscopically assisted insertion method were analyzed. The outcome measures were the pedicle widths, the gap between the outer pedicle width and the selected pedicle screw diameter, and the penetration length of the pedicle screws using computed tomography. The screws were distributed into two groups according to the pedicle width and screw diameter, and the screw perforation rate of the two groups was compared. The relationships of the gap and the distance of the screw penetration were compared and investigated in regard to the pedicle screw diameter selection.

Results

A total of 16 screws demonstrated a smaller diameter than the inner pedicle widths, while 22 screws had a larger diameter than the inner pedicle widths. One screw (6.3%) perforated the pedicle cortex in the smaller screw group, and twelve screws (54.5%) perforated the pedicle cortex in the larger screw group (P = 0.006). A linear regression analysis in the larger screw group revealed that when the gap was less than 0.5 mm, a risk of a pedicle wall violation was observed.

Conclusions

When the screws with a larger diameter than the inner pedicle width are selected, the screw perforation rate increases. Therefore, the size of the screw diameter must be at least 0.5 mm less than the outer pedicle width to ensure safe transpedicular screw placement.
Literatur
1.
Zurück zum Zitat Liljenqvist U, Hackenberg L, Link T et al (2001) Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg 67:157–163PubMed Liljenqvist U, Hackenberg L, Link T et al (2001) Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg 67:157–163PubMed
2.
Zurück zum Zitat Kostuik JP, Munting E, Valdevit A (1994) Biomechanical analysis of screw load sharing in pedicle fixation of the lumbar spine. J Spinal Disord 7:394–401PubMedCrossRef Kostuik JP, Munting E, Valdevit A (1994) Biomechanical analysis of screw load sharing in pedicle fixation of the lumbar spine. J Spinal Disord 7:394–401PubMedCrossRef
3.
Zurück zum Zitat Belmont PJ, Klemme WR, Dhawan A et al (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346PubMedCrossRef Belmont PJ, Klemme WR, Dhawan A et al (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346PubMedCrossRef
4.
Zurück zum Zitat Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14PubMedCrossRef Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14PubMedCrossRef
5.
Zurück zum Zitat Kothe R, O’Holleran JD, Liu W et al (1996) Internal architecture of the thoracic pedicle. An anatomic study. Spine 21:264–270PubMedCrossRef Kothe R, O’Holleran JD, Liu W et al (1996) Internal architecture of the thoracic pedicle. An anatomic study. Spine 21:264–270PubMedCrossRef
6.
Zurück zum Zitat McLain RF, Ferrara L, Kabins M (2002) Pedicle morphometry in the upper thoracic spine: limits to safe screw placement in older patients. Spine 27:2467–2471PubMedCrossRef McLain RF, Ferrara L, Kabins M (2002) Pedicle morphometry in the upper thoracic spine: limits to safe screw placement in older patients. Spine 27:2467–2471PubMedCrossRef
7.
Zurück zum Zitat Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Jt Surg Am 77:1193–1199 Vaccaro AR, Rizzolo SJ, Allardyce TJ et al (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Jt Surg Am 77:1193–1199
8.
Zurück zum Zitat Bransford R, Bellabarba C, Thompson JH et al (2006) The safety of fluoroscopically-assisted thoracic pedicle screw instrumentation for spine trauma. J Trauma 60:1047–1052PubMedCrossRef Bransford R, Bellabarba C, Thompson JH et al (2006) The safety of fluoroscopically-assisted thoracic pedicle screw instrumentation for spine trauma. J Trauma 60:1047–1052PubMedCrossRef
9.
Zurück zum Zitat Di Silvestre M, Parisini P, Lolli F et al (2007) Complications of thoracic pedicle screws in scoliosis treatment. Spine 32:1655–1661PubMedCrossRef Di Silvestre M, Parisini P, Lolli F et al (2007) Complications of thoracic pedicle screws in scoliosis treatment. Spine 32:1655–1661PubMedCrossRef
10.
Zurück zum Zitat Lonstein JE, Denis F, Perra JH et al (1999) Complications associated with pedicle screws. J Bone Jt Surg Am 81:1519–1528 Lonstein JE, Denis F, Perra JH et al (1999) Complications associated with pedicle screws. J Bone Jt Surg Am 81:1519–1528
11.
Zurück zum Zitat Vaccaro AR, Rizzolo SJ, Balderston RA et al (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed Vaccaro AR, Rizzolo SJ, Balderston RA et al (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed
12.
Zurück zum Zitat Misenhimer GR, Peek RD, Wiltse LL et al (1989) Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine 14:367–372PubMedCrossRef Misenhimer GR, Peek RD, Wiltse LL et al (1989) Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine 14:367–372PubMedCrossRef
13.
Zurück zum Zitat Kothe R, Panjabi MM, Liu W et al (1997) Multidirectional instability of the thoracic spine due to iatrogenic pedicle injuries during transpedicular fixation. A biomechanical investigation. Spine 22:1836–1842PubMedCrossRef Kothe R, Panjabi MM, Liu W et al (1997) Multidirectional instability of the thoracic spine due to iatrogenic pedicle injuries during transpedicular fixation. A biomechanical investigation. Spine 22:1836–1842PubMedCrossRef
14.
Zurück zum Zitat Carbone JJ, Tortolani PJ, Quartararo LG (2003) Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications. Spine 28:91–97PubMedCrossRef Carbone JJ, Tortolani PJ, Quartararo LG (2003) Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications. Spine 28:91–97PubMedCrossRef
15.
Zurück zum Zitat Fu TS, Wong CB, Tsai TT et al (2008) Pedicle screw insertion: computed tomography versus fluoroscopic image guidance. Int Orthop 32:517–521PubMedCrossRef Fu TS, Wong CB, Tsai TT et al (2008) Pedicle screw insertion: computed tomography versus fluoroscopic image guidance. Int Orthop 32:517–521PubMedCrossRef
16.
Zurück zum Zitat Kim YJ, Lenke LG, Bridwell KH et al (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342PubMedCrossRef Kim YJ, Lenke LG, Bridwell KH et al (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29:333–342PubMedCrossRef
17.
Zurück zum Zitat Kuntz C 4th, Maher PC, Levine NB et al (2004) Prospective evaluation of thoracic pedicle screw placement using fluoroscopic imaging. J Spinal Disord Tech 17:206–214PubMedCrossRef Kuntz C 4th, Maher PC, Levine NB et al (2004) Prospective evaluation of thoracic pedicle screw placement using fluoroscopic imaging. J Spinal Disord Tech 17:206–214PubMedCrossRef
18.
Zurück zum Zitat Castro WH, Halm H, Jerosch J et al (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324PubMedCrossRef Castro WH, Halm H, Jerosch J et al (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324PubMedCrossRef
19.
Zurück zum Zitat Farber GI, Place HM, Mazur RA et al (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 13:1494–1499CrossRef Farber GI, Place HM, Mazur RA et al (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 13:1494–1499CrossRef
20.
Zurück zum Zitat Yazici M, Pekmezci M, Cil A et al (2006) The effect of pedicle expansion on pedicle morphology and biomechanical stability in the immature porcine spine. Spine 31:E826–E829PubMedCrossRef Yazici M, Pekmezci M, Cil A et al (2006) The effect of pedicle expansion on pedicle morphology and biomechanical stability in the immature porcine spine. Spine 31:E826–E829PubMedCrossRef
21.
Zurück zum Zitat Soshi S, Shiba R, Kondo H et al (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335–1341PubMedCrossRef Soshi S, Shiba R, Kondo H et al (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335–1341PubMedCrossRef
22.
Zurück zum Zitat White KK, Oka R, Mahar AT et al (2006) Pullout strength of thoracic pedicle screw instrumentation: comparison of the transpedicular and extrapedicular techniques. Spine 31:E355–E358PubMedCrossRef White KK, Oka R, Mahar AT et al (2006) Pullout strength of thoracic pedicle screw instrumentation: comparison of the transpedicular and extrapedicular techniques. Spine 31:E355–E358PubMedCrossRef
Metadaten
Titel
Pedicle screw diameter selection for safe insertion in the thoracic spine
verfasst von
Toru Fujimoto
Akira Sei
Takuya Taniwaki
Tatsuya Okada
Toshitake Yakushiji
Hiroshi Mizuta
Publikationsdatum
01.07.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 5/2012
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-011-0846-2

Weitere Artikel der Ausgabe 5/2012

European Journal of Orthopaedic Surgery & Traumatology 5/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.