Skip to main content
Erschienen in: Journal of Cardiovascular Translational Research 2/2009

01.06.2009

Physiologic and Pathologic Changes in Patients with Continuous-Flow Ventricular Assist Devices

verfasst von: Ranjit John, Andrew Boyle, Frank Pagani, Leslie Miller

Erschienen in: Journal of Cardiovascular Translational Research | Ausgabe 2/2009

Einloggen, um Zugang zu erhalten

Abstract

The clinical use of the newer continuous-flow pumps for mechanical circulatory support have resulted in superior outcomes including significantly reduced complication rates with improved durability over first generation pulsatile design pumps. However, as with all new technology, the newer LVADs have introduced a different set of management issues, as well as a unique risk profile into the mechanical circulatory support arena that were previously absent or unimportant with pulsatile LVADs. These include the effects of continuous flow on the systemic circulation and end-organ function, risk of thromboembolism, and pump thrombosis related to contact bearings in the blood path, the possible increased incidence of gastrointestinal bleeding, and ventricular arrhythmias, as well as alterations in the unloading characteristics of continuous-flow devices. This manuscript overviews the physiologic and pathologic effects that are associated with continuous-flow pumps and their unique management issues and complications.
Literatur
1.
Zurück zum Zitat Frazier, O. H., Rose, E. A., Oz, M. C., et al. (2001). Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. Journal of thoracic and cardiovascular surgery, 122, 1186–1195.PubMedCrossRef Frazier, O. H., Rose, E. A., Oz, M. C., et al. (2001). Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. Journal of thoracic and cardiovascular surgery, 122, 1186–1195.PubMedCrossRef
2.
Zurück zum Zitat Frazier, O. H., Rose, E. A., McCarthy, P., et al. (1995). Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system. Annals of Surgery, 222, 327–336.PubMedCrossRef Frazier, O. H., Rose, E. A., McCarthy, P., et al. (1995). Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system. Annals of Surgery, 222, 327–336.PubMedCrossRef
3.
Zurück zum Zitat Morgan, J. A., John, R., Rao, V., et al. (2004). Bridging to transplant with the HeartMate left ventricular assist device: The Columbia Presbyterian 12-year experience. Journal of thoracic and cardiovascular surgery, 127, 1309–1316.PubMedCrossRef Morgan, J. A., John, R., Rao, V., et al. (2004). Bridging to transplant with the HeartMate left ventricular assist device: The Columbia Presbyterian 12-year experience. Journal of thoracic and cardiovascular surgery, 127, 1309–1316.PubMedCrossRef
4.
Zurück zum Zitat Rose, E. A., Gelijns, A. C., Moskowitz, A. J., et al. (2001). Long-term mechanical left ventricular assistance for end-stage heart failure. New England Journal of Medicine, 345, 1435–1443.PubMedCrossRef Rose, E. A., Gelijns, A. C., Moskowitz, A. J., et al. (2001). Long-term mechanical left ventricular assistance for end-stage heart failure. New England Journal of Medicine, 345, 1435–1443.PubMedCrossRef
5.
Zurück zum Zitat Pagani, F. D., Long, J. W., Dembitsky, W. P., et al. (2006). Improved mechanical reliability of the HeartMate XVE left ventricular assist system. Annals of Thoracic Surgery, 82, 1413–1419.PubMedCrossRef Pagani, F. D., Long, J. W., Dembitsky, W. P., et al. (2006). Improved mechanical reliability of the HeartMate XVE left ventricular assist system. Annals of Thoracic Surgery, 82, 1413–1419.PubMedCrossRef
6.
Zurück zum Zitat Feller, E. D., Sorensen, E. N., Haddad, M., et al. (2007). Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Annals of Thoracic Surgery, 83, 1082–1088.PubMedCrossRef Feller, E. D., Sorensen, E. N., Haddad, M., et al. (2007). Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Annals of Thoracic Surgery, 83, 1082–1088.PubMedCrossRef
7.
Zurück zum Zitat Frazier, O. H., Gemmato, C., Myers, T. J., et al. (2007). Initial clinical experience with the HeartMate II axial-flow left ventricular assist device. Texas Heart Institute Journal, 34, 275–281.PubMed Frazier, O. H., Gemmato, C., Myers, T. J., et al. (2007). Initial clinical experience with the HeartMate II axial-flow left ventricular assist device. Texas Heart Institute Journal, 34, 275–281.PubMed
8.
Zurück zum Zitat Miller, L. W., Pagani, F. D., Russell, S. D., et al. (2007). Use of a continuous-flow device in patients awaiting heart transplantation. New England Journal of Medicine, 357, 885–896.PubMedCrossRef Miller, L. W., Pagani, F. D., Russell, S. D., et al. (2007). Use of a continuous-flow device in patients awaiting heart transplantation. New England Journal of Medicine, 357, 885–896.PubMedCrossRef
9.
Zurück zum Zitat John, R., Kamdar, F., Liao, K., et al. (2008). Improved survival and decreasing incidence of adverse events using the HeartMate II left ventricular assist device as a bridge-to-transplant. Annals of Thoracic Surgery, 86, 1227–1235.PubMedCrossRef John, R., Kamdar, F., Liao, K., et al. (2008). Improved survival and decreasing incidence of adverse events using the HeartMate II left ventricular assist device as a bridge-to-transplant. Annals of Thoracic Surgery, 86, 1227–1235.PubMedCrossRef
10.
Zurück zum Zitat John, R. (2008). Current axial flow pumps—HeartMate II and Jarvik LVADs. Seminars in Thoracic and Cardiovascular Surgery, 20, 264–272.PubMedCrossRef John, R. (2008). Current axial flow pumps—HeartMate II and Jarvik LVADs. Seminars in Thoracic and Cardiovascular Surgery, 20, 264–272.PubMedCrossRef
11.
Zurück zum Zitat Rose, E. A., Levin, H. R., Oz, M. C., et al. (1994). Artificial circulatory support with textured interior surfaces: a counterintuitive approach to minimize thromboembolism. Circulation, 90(5 pt 2), II87–91.PubMed Rose, E. A., Levin, H. R., Oz, M. C., et al. (1994). Artificial circulatory support with textured interior surfaces: a counterintuitive approach to minimize thromboembolism. Circulation, 90(5 pt 2), II87–91.PubMed
12.
Zurück zum Zitat John, R., Kamdar, F., Liao, K., et al. (2008). Low thromboembolic risk with the HeartMate II left ventricular assist device. Journal of thoracic and cardiovascular surgery, 136, 1318–1323.PubMedCrossRef John, R., Kamdar, F., Liao, K., et al. (2008). Low thromboembolic risk with the HeartMate II left ventricular assist device. Journal of thoracic and cardiovascular surgery, 136, 1318–1323.PubMedCrossRef
13.
Zurück zum Zitat Letsou, G. V., Shah, N., Gregoric, I. D., et al. (2005). Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device. Journal of Heart and Lung Transplantation, 24, 105–109.PubMedCrossRef Letsou, G. V., Shah, N., Gregoric, I. D., et al. (2005). Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device. Journal of Heart and Lung Transplantation, 24, 105–109.PubMedCrossRef
14.
Zurück zum Zitat Crow, S., John, R., Boyle, A., et al. (2009). Gastrointestinal bleeding rates in recipients of non-pulsatile and pulsatile left ventricular assist devices. Journal of Thoracic and Cardiovascular Surgery, 137, 208–215.PubMedCrossRef Crow, S., John, R., Boyle, A., et al. (2009). Gastrointestinal bleeding rates in recipients of non-pulsatile and pulsatile left ventricular assist devices. Journal of Thoracic and Cardiovascular Surgery, 137, 208–215.PubMedCrossRef
15.
Zurück zum Zitat Heyde, E. C. (1958). Gastrointestinal bleeding in aortic stenosis (letter). New England Journal of Medicine, 259, 196. Heyde, E. C. (1958). Gastrointestinal bleeding in aortic stenosis (letter). New England Journal of Medicine, 259, 196.
16.
Zurück zum Zitat Boley, S. J., Sammarteno, R., Adams A., et al. (1977). Vascular ectasias of the colon. On the nature and etiology of vascular ectasias of the colon. Gastroenterolgy, 72, 650–660. Boley, S. J., Sammarteno, R., Adams A., et al. (1977). Vascular ectasias of the colon. On the nature and etiology of vascular ectasias of the colon. Gastroenterolgy, 72, 650–660.
17.
Zurück zum Zitat Warkentin, T. E., Moore, J. C., & Morgan, D. G. (1992). Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand’s disease the link? Lancet, 340, 35–37.PubMedCrossRef Warkentin, T. E., Moore, J. C., & Morgan, D. G. (1992). Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand’s disease the link? Lancet, 340, 35–37.PubMedCrossRef
18.
Zurück zum Zitat Furlan, M. (1996). von Willebrand factor: molecular size and functional activity. Annals of Hematology, 72, 341–348.PubMedCrossRef Furlan, M. (1996). von Willebrand factor: molecular size and functional activity. Annals of Hematology, 72, 341–348.PubMedCrossRef
19.
20.
Zurück zum Zitat Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., et al. (2003). Acquired von Willebrand syndrome in aortic stenosis. New England Journal of Medicine, 349, 343–349.PubMedCrossRef Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., et al. (2003). Acquired von Willebrand syndrome in aortic stenosis. New England Journal of Medicine, 349, 343–349.PubMedCrossRef
21.
Zurück zum Zitat Geisen, U., Heilmann, C., Beyersdorf, F., et al. (2008). Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. European Journal of Cardiothoracic Surgery, 22, 679–684.CrossRef Geisen, U., Heilmann, C., Beyersdorf, F., et al. (2008). Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. European Journal of Cardiothoracic Surgery, 22, 679–684.CrossRef
22.
Zurück zum Zitat Weslowski, S., Fisher, J., & Welch, C. (1953). Perfusion of the pulmonary circulation by non-pulsatile flow. Surgery, 33, 370. Weslowski, S., Fisher, J., & Welch, C. (1953). Perfusion of the pulmonary circulation by non-pulsatile flow. Surgery, 33, 370.
23.
Zurück zum Zitat Johnston, G. G., Hammill, F., Marzec, U., et al. (1976). Prolonged pulseless perfusion in unanesthetized calves. Archives of Surgery, 111, 1125–1130. Johnston, G. G., Hammill, F., Marzec, U., et al. (1976). Prolonged pulseless perfusion in unanesthetized calves. Archives of Surgery, 111, 1125–1130.
24.
Zurück zum Zitat Saito, S., Westaby, S., Piggot, D., et al. (2002). End-organ function during chronic nonpulsatile circulation. Annals of Thoracic Surgery, 74, 1080–1085.PubMedCrossRef Saito, S., Westaby, S., Piggot, D., et al. (2002). End-organ function during chronic nonpulsatile circulation. Annals of Thoracic Surgery, 74, 1080–1085.PubMedCrossRef
25.
Zurück zum Zitat Nakata, K., Shiono, M., Orime, Y., et al. (1996). Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock. Artificial Organs, 20, 681–684.PubMedCrossRef Nakata, K., Shiono, M., Orime, Y., et al. (1996). Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock. Artificial Organs, 20, 681–684.PubMedCrossRef
26.
Zurück zum Zitat Letsou, G. V., Myers, T. J., Gregoric, I. D., et al. (2003). Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months. Annals of Thoracic Surgery, 76, 1167–1170.PubMedCrossRef Letsou, G. V., Myers, T. J., Gregoric, I. D., et al. (2003). Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months. Annals of Thoracic Surgery, 76, 1167–1170.PubMedCrossRef
27.
Zurück zum Zitat Radovancevic, B., Vrtovec, B., de Kort, E., Radovancevic, R., Gregoric, I. D., & Frazier, O. H. (2007). End-organ function in patients on long-term circulatory support with continuous or pulsatile-flow assist devices. Journal of Heart Transplantation, 26(8), 815–818.CrossRef Radovancevic, B., Vrtovec, B., de Kort, E., Radovancevic, R., Gregoric, I. D., & Frazier, O. H. (2007). End-organ function in patients on long-term circulatory support with continuous or pulsatile-flow assist devices. Journal of Heart Transplantation, 26(8), 815–818.CrossRef
28.
Zurück zum Zitat Kamdar, F., Boyle, A., Liao, K., Colvin-Adams, M., Joyce, L., John, R. (2009). Effects of centrifugal, axial and pulsatile left ventricular assist device (LVAD) support on end-organ function in heart failure patients. Journal of Heart and Lung Transplantation (in press). Kamdar, F., Boyle, A., Liao, K., Colvin-Adams, M., Joyce, L., John, R. (2009). Effects of centrifugal, axial and pulsatile left ventricular assist device (LVAD) support on end-organ function in heart failure patients. Journal of Heart and Lung Transplantation (in press).
29.
Zurück zum Zitat Klotz, S., Deng, M. C., Stymann, J., et al. (2004). Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Annals of Thoracic Surgery, 77, 143–150.PubMedCrossRef Klotz, S., Deng, M. C., Stymann, J., et al. (2004). Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Annals of Thoracic Surgery, 77, 143–150.PubMedCrossRef
30.
Zurück zum Zitat Haft, J., Armstrong, W., Dyke, D. B., et al. (2007). Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation, 116, I–8–15.CrossRef Haft, J., Armstrong, W., Dyke, D. B., et al. (2007). Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation, 116, I–8–15.CrossRef
31.
Zurück zum Zitat Thohan, V., Stetson, S. J., Nagueh, S. F., et al. (2005). Cellular and hemodynamic responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. Journal of Heart Transplantation, 24, 566–575.CrossRef Thohan, V., Stetson, S. J., Nagueh, S. F., et al. (2005). Cellular and hemodynamic responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. Journal of Heart Transplantation, 24, 566–575.CrossRef
32.
Zurück zum Zitat Garcia, S., Kamdar, F., Boyle, A., et al. (2008). Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading. Journal of Heart Transplantation, 27, 261–267.CrossRef Garcia, S., Kamdar, F., Boyle, A., et al. (2008). Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading. Journal of Heart Transplantation, 27, 261–267.CrossRef
33.
Zurück zum Zitat Etz, C. D., Welp, H. A., Tjan, T. D., et al. (2007). Medically refractory pulmonary hypertension: treatment with nonpulsatile left ventricular assist devices. Annals of Thoracic Surgery, 83, 1697–1706.PubMedCrossRef Etz, C. D., Welp, H. A., Tjan, T. D., et al. (2007). Medically refractory pulmonary hypertension: treatment with nonpulsatile left ventricular assist devices. Annals of Thoracic Surgery, 83, 1697–1706.PubMedCrossRef
34.
Zurück zum Zitat Cao, X., Haft, J., Dyke, D. B., et al. Increased incidence of ventricular tachycardia following left ventricular assist device implantation with continuous flow rotary pumps. Presented at 10th Annual Scientific Meeting of the Heart Failure Society of America, Sep 2006, Seattle, WA. Cao, X., Haft, J., Dyke, D. B., et al. Increased incidence of ventricular tachycardia following left ventricular assist device implantation with continuous flow rotary pumps. Presented at 10th Annual Scientific Meeting of the Heart Failure Society of America, Sep 2006, Seattle, WA.
35.
Zurück zum Zitat Vollkron, M., Voitl, P., Ta, J., et al. (2007). Suction events during left ventricular and ventricular arrhythmias. Journal of Heart Transplantation, 26, 819–825.CrossRef Vollkron, M., Voitl, P., Ta, J., et al. (2007). Suction events during left ventricular and ventricular arrhythmias. Journal of Heart Transplantation, 26, 819–825.CrossRef
36.
Zurück zum Zitat Wu, Yi., Allaire, P., Tao, G., et al. (2003). An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse. Artificial Organs, 10, 926–930.CrossRef Wu, Yi., Allaire, P., Tao, G., et al. (2003). An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse. Artificial Organs, 10, 926–930.CrossRef
37.
Zurück zum Zitat Vollkron, M., Schima, H., Huber, L., et al. (2006). Advanced suction detection for an axial flow pump. Artificial Organs, 9, 665–670.CrossRef Vollkron, M., Schima, H., Huber, L., et al. (2006). Advanced suction detection for an axial flow pump. Artificial Organs, 9, 665–670.CrossRef
Metadaten
Titel
Physiologic and Pathologic Changes in Patients with Continuous-Flow Ventricular Assist Devices
verfasst von
Ranjit John
Andrew Boyle
Frank Pagani
Leslie Miller
Publikationsdatum
01.06.2009
Verlag
Springer US
Erschienen in
Journal of Cardiovascular Translational Research / Ausgabe 2/2009
Print ISSN: 1937-5387
Elektronische ISSN: 1937-5395
DOI
https://doi.org/10.1007/s12265-009-9092-y

Weitere Artikel der Ausgabe 2/2009

Journal of Cardiovascular Translational Research 2/2009 Zur Ausgabe

Die „Zehn Gebote“ des Endokarditis-Managements

30.04.2024 Endokarditis Leitlinie kompakt

Worauf kommt es beim Management von Personen mit infektiöser Endokarditis an? Eine Kardiologin und ein Kardiologe fassen die zehn wichtigsten Punkte der neuen ESC-Leitlinie zusammen.

Strenge Blutdruckeinstellung lohnt auch im Alter noch

30.04.2024 Arterielle Hypertonie Nachrichten

Ältere Frauen, die von chronischen Erkrankungen weitgehend verschont sind, haben offenbar die besten Chancen, ihren 90. Geburtstag zu erleben, wenn ihr systolischer Blutdruck < 130 mmHg liegt. Das scheint selbst für 80-Jährige noch zu gelten.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Dihydropyridin-Kalziumantagonisten können auf die Nieren gehen

30.04.2024 Hypertonie Nachrichten

Im Vergleich zu anderen Blutdrucksenkern sind Kalziumantagonisten vom Diyhdropyridin-Typ mit einem erhöhten Risiko für eine Mikroalbuminurie und in Abwesenheit eines RAS-Blockers auch für ein terminales Nierenversagen verbunden.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.