Skip to main content
Erschienen in: Journal of Medical Systems 5/2011

01.10.2011 | Original Paper

Post-Operative Assessment of an Implant Fixation in Anterior Cruciate Ligament Reconstructive Surgery

verfasst von: Mahmoud Chizari, Martyn Snow, Bin Wang

Erschienen in: Journal of Medical Systems | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

The objective of this paper is to numerically simulate the behaviour of an anterior cruciate ligament (ACL) reconstructed knee using interference screw fixation under a single cycle loading or a cyclic loading test and to compare the numerical results with experimental tests using porcine samples of knee joint. A hyper-elastic material model was used to model the tendon graft and evaluate its elongation during continuous and cyclic tensile loading. The rigidity of the interference screw fixation was also examined using the finite element based numerical model. The finite element model uses the benefit of an anatomical 3D geometry of the tibial bone and tendon graft which was created from a CT scan of a patient.
Literatur
1.
Zurück zum Zitat Uh, B. S., Beynnon, B. D., and Johnson, R. J., The biomechanical background of the reconstruction of the anterior cruciate ligament. Bailliere’s Clin. Orthop. 2:47–62, 1997. Uh, B. S., Beynnon, B. D., and Johnson, R. J., The biomechanical background of the reconstruction of the anterior cruciate ligament. Bailliere’s Clin. Orthop. 2:47–62, 1997.
2.
Zurück zum Zitat Beynnon, B. D., and Amis, A. A., In vitro testing protocols for the cruciate ligaments and ligament reconstructions. Knee Surg. Sports Traumatol. Arthrosc. 6(1):S70–S76, 1998.CrossRef Beynnon, B. D., and Amis, A. A., In vitro testing protocols for the cruciate ligaments and ligament reconstructions. Knee Surg. Sports Traumatol. Arthrosc. 6(1):S70–S76, 1998.CrossRef
3.
Zurück zum Zitat Beynnon, B. D., Johnson, R. J., and Fleming, B. C., The science of anterior cruciate ligament rehabilitation. Clin. Orthop. 402:9–20, 2002.CrossRef Beynnon, B. D., Johnson, R. J., and Fleming, B. C., The science of anterior cruciate ligament rehabilitation. Clin. Orthop. 402:9–20, 2002.CrossRef
4.
Zurück zum Zitat Giurea, M., Zorilla, P., Amis, A. A., et al., Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am. J. Sports Med. 27:621–625, 1999. Giurea, M., Zorilla, P., Amis, A. A., et al., Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am. J. Sports Med. 27:621–625, 1999.
5.
Zurück zum Zitat Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation in cruciate ligament reconstruction. Current concepts. Am. J. Sports Med. 28:761–774, 2000. Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation in cruciate ligament reconstruction. Current concepts. Am. J. Sports Med. 28:761–774, 2000.
6.
Zurück zum Zitat Brand, J., Pienkowski, D., Steenlage, E., et al., Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am. J. Sports Med. 28:705–710, 2000. Brand, J., Pienkowski, D., Steenlage, E., et al., Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am. J. Sports Med. 28:705–710, 2000.
7.
Zurück zum Zitat Kohn, D., and Rose, C., Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am. J. Sports Med. 22:334–338, 1994.CrossRef Kohn, D., and Rose, C., Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am. J. Sports Med. 22:334–338, 1994.CrossRef
8.
Zurück zum Zitat Sievänen, H., Koskue, V., Rauhio, A., et al., Peripheral quantitative computed tomography in human long bones. Evaluation of in vitro and in vivo precision. J. Bone Miner. Res. 13:871–882, 1998.CrossRef Sievänen, H., Koskue, V., Rauhio, A., et al., Peripheral quantitative computed tomography in human long bones. Evaluation of in vitro and in vivo precision. J. Bone Miner. Res. 13:871–882, 1998.CrossRef
9.
Zurück zum Zitat Malek, M. M., DeLuca, J. V., Verch, D. L., et al., Arthroscopically assisted ACL reconstruction using central third patellar tendon autograft with press fit femoral fixation. Instr. Course Lect. 45:287–295, 1996. Malek, M. M., DeLuca, J. V., Verch, D. L., et al., Arthroscopically assisted ACL reconstruction using central third patellar tendon autograft with press fit femoral fixation. Instr. Course Lect. 45:287–295, 1996.
10.
Zurück zum Zitat Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation issues in knee ligament surgery. Oper. Tech. Orthop. 9:256–263, 1999.CrossRef Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation issues in knee ligament surgery. Oper. Tech. Orthop. 9:256–263, 1999.CrossRef
11.
Zurück zum Zitat Pena, F., Grontvedt, T., Brown, G. A., Aune, A. K., and Engebretsen, L., Comparisonof failure strength between metallic and absorbable interferencescrews. Influence of insertion torque, tunnel-bone block gap, bone mineraldensity, and interference. Am. J. Sports Med. 24:329–334, 1996.CrossRef Pena, F., Grontvedt, T., Brown, G. A., Aune, A. K., and Engebretsen, L., Comparisonof failure strength between metallic and absorbable interferencescrews. Influence of insertion torque, tunnel-bone block gap, bone mineraldensity, and interference. Am. J. Sports Med. 24:329–334, 1996.CrossRef
12.
Zurück zum Zitat Clark, R., Olsen, R. E., Larson, B. J., et al., Cross pin femoral fixation: a new technique for hamstring anterior cruciate ligament reconstruction of the knee. Arthroscopy 14:258–267, 1998.CrossRef Clark, R., Olsen, R. E., Larson, B. J., et al., Cross pin femoral fixation: a new technique for hamstring anterior cruciate ligament reconstruction of the knee. Arthroscopy 14:258–267, 1998.CrossRef
13.
Zurück zum Zitat Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part I, Femoral site. Am. J. Sports Med. 31:174–181, 2003. Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part I, Femoral site. Am. J. Sports Med. 31:174–181, 2003.
14.
Zurück zum Zitat Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part II, Tibial site. Am. J. Sports Med. 31:182–188, 2003. Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part II, Tibial site. Am. J. Sports Med. 31:182–188, 2003.
15.
Zurück zum Zitat Magen, H. E., Howell, S. M., and Hull, M. L., Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am. J. Sports Med. 27:35–43, 1999. Magen, H. E., Howell, S. M., and Hull, M. L., Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am. J. Sports Med. 27:35–43, 1999.
16.
Zurück zum Zitat Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., et al., Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14:29–37, 1998.CrossRef Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., et al., Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14:29–37, 1998.CrossRef
17.
Zurück zum Zitat DeLay, B. S., Smolinski, R. J., Wind, W. M., et al., Current practices and opinions in ACL reconstruction and rehabilitation. Results of a survey of the American Orthopaedic Society for Sports Medicine. Am. J. Knee Surg. 14:85–91, 2001. DeLay, B. S., Smolinski, R. J., Wind, W. M., et al., Current practices and opinions in ACL reconstruction and rehabilitation. Results of a survey of the American Orthopaedic Society for Sports Medicine. Am. J. Knee Surg. 14:85–91, 2001.
18.
Zurück zum Zitat Harner, C. D., Fu, F. H., Irrgang, J. J., et al., Anterior and posterior cruciate ligament reconstruction in the new millennium. A global perspective. Knee Surg. Sports Traumatol. Arthrosc. 9:330–336, 2001.CrossRef Harner, C. D., Fu, F. H., Irrgang, J. J., et al., Anterior and posterior cruciate ligament reconstruction in the new millennium. A global perspective. Knee Surg. Sports Traumatol. Arthrosc. 9:330–336, 2001.CrossRef
20.
Zurück zum Zitat Chizari, M., Wang, B., Snow, M., and Barrett, M., Experimental and numerical analysis of screw fixation in anterior cruciate ligament reconstruction. AIP Conf. Proc. 1045:61, 2008b, doi:10.1063/1.2991351. Chizari, M., Wang, B., Snow, M., and Barrett, M., Experimental and numerical analysis of screw fixation in anterior cruciate ligament reconstruction. AIP Conf. Proc. 1045:61, 2008b, doi:10.​1063/​1.​2991351.
21.
Zurück zum Zitat Gérard, J. M., Ohayon, J., Luboz, V., Perrier, P., and Payan, Y., Indentation for estimating the human tongue soft tissues constitutive law: application to a 3D biomechanical model, Lecture Notes in Computer Science, vol. 3078. Springer, Berlin / Heidelberg, pp. 77–83, 2004. Gérard, J. M., Ohayon, J., Luboz, V., Perrier, P., and Payan, Y., Indentation for estimating the human tongue soft tissues constitutive law: application to a 3D biomechanical model, Lecture Notes in Computer Science, vol. 3078. Springer, Berlin / Heidelberg, pp. 77–83, 2004.
22.
Zurück zum Zitat Treloar, L. R. G., The physics of rubber elasticity. Oxford University Press, London, 1958. Treloar, L. R. G., The physics of rubber elasticity. Oxford University Press, London, 1958.
23.
Zurück zum Zitat Klute, G. K., and Hannaford, B., Fatigue characteristics of McKibben artificial muscle actuators. Proceedings, IEEE/RSJ 1998 International Conference on Intelligent Robotic Systems (IROS ’98), Victoria BC, Canada, Vol. 3, pp. 1776–1781, 1998. Klute, G. K., and Hannaford, B., Fatigue characteristics of McKibben artificial muscle actuators. Proceedings, IEEE/RSJ 1998 International Conference on Intelligent Robotic Systems (IROS ’98), Victoria BC, Canada, Vol. 3, pp. 1776–1781, 1998.
24.
Zurück zum Zitat Gerard, J., Wilhelms-Tricarico, R., Perrier, P., and Payan, Y., A 3D dynamical biomechanical tongue model to study speech motor control. Recent Res. Dev. Biomech. 1:49–64, 2003. Gerard, J., Wilhelms-Tricarico, R., Perrier, P., and Payan, Y., A 3D dynamical biomechanical tongue model to study speech motor control. Recent Res. Dev. Biomech. 1:49–64, 2003.
25.
Zurück zum Zitat Chabanas, M., Payan, Y., Marecaux, C., Swider, P., Boutault, F., Comparison of linear and non-linear soft tissue models with post-operative CT scan in maxillofacial surgery. International Symposium on Medical Simulation, Cambridge, Massachusetts, Vol. 3078, 19–27, 2004. Chabanas, M., Payan, Y., Marecaux, C., Swider, P., Boutault, F., Comparison of linear and non-linear soft tissue models with post-operative CT scan in maxillofacial surgery. International Symposium on Medical Simulation, Cambridge, Massachusetts, Vol. 3078, 19–27, 2004.
26.
Zurück zum Zitat Black, K. P., Saunders, M. M., Stube, K. C., et al., Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction. Am. J. Sports Med. 28:846–849, 2000. Black, K. P., Saunders, M. M., Stube, K. C., et al., Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction. Am. J. Sports Med. 28:846–849, 2000.
27.
Zurück zum Zitat Ishibashi, Y., Rudy, T. W., Livesay, G. A., et al., The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability, evaluation using a robotic testing system. Arthroscopy 13:177–182, 1997.CrossRef Ishibashi, Y., Rudy, T. W., Livesay, G. A., et al., The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability, evaluation using a robotic testing system. Arthroscopy 13:177–182, 1997.CrossRef
28.
Zurück zum Zitat Miyata, K., Yasuda, K., Kondo, E., et al., Biomechanical comparisons of anterior cruciate ligament, reconstruction procedures with flexor tendon graft. J. Orthop. Sci. 5:585–592, 2000.CrossRef Miyata, K., Yasuda, K., Kondo, E., et al., Biomechanical comparisons of anterior cruciate ligament, reconstruction procedures with flexor tendon graft. J. Orthop. Sci. 5:585–592, 2000.CrossRef
29.
Zurück zum Zitat Nagarkatti, D. G., McKeon, B. P., Donahue, B. S., et al., Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am. J. Sports Med. 29:67–71, 2001. Nagarkatti, D. G., McKeon, B. P., Donahue, B. S., et al., Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am. J. Sports Med. 29:67–71, 2001.
30.
Zurück zum Zitat Rupp, S., Seil, R., Schneider, A., et al., Ligament graft initial fixation strength using biodegradable interference screws. J. Biomed. Mater. Res. 48:70–74, 1999.CrossRef Rupp, S., Seil, R., Schneider, A., et al., Ligament graft initial fixation strength using biodegradable interference screws. J. Biomed. Mater. Res. 48:70–74, 1999.CrossRef
Metadaten
Titel
Post-Operative Assessment of an Implant Fixation in Anterior Cruciate Ligament Reconstructive Surgery
verfasst von
Mahmoud Chizari
Martyn Snow
Bin Wang
Publikationsdatum
01.10.2011
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 5/2011
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9514-z

Weitere Artikel der Ausgabe 5/2011

Journal of Medical Systems 5/2011 Zur Ausgabe