Skip to main content
Erschienen in: Critical Care 1/2016

Open Access 01.12.2016 | Letter

Preload dependence and hypotension: One of the causes and one of the consequences of poor tolerance of intermittent hemodialysis in the ICU?

verfasst von: Jérôme Allyn, Laure Corradi, Nicolas Allou, Bernard Alex Gaüzère

Erschienen in: Critical Care | Ausgabe 1/2016

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
Hinweise
This comment refers to the article available at: http://​dx.​doi.​org/​10.​1186/​s13054-016-1227-3.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

All authors read and approved the final manuscript.
Abkürzungen
E/Ea
mitral inflow E wave to early diastolic mitral annulus velocities ratio
ICU
intensive care unit
IHD
intermittent hemodialysis
In the context of a better management of a negative fluid balance in critically ill patients, Bitker et al. recently published a prospective, observational study in Critical Care [1]. The occurrence of hypotension in 47 patients during 107 sessions of intermittent hemodialysis (IHD) was analyzed. The authors demonstrated that hypotension occurs frequently (57 %) but is seldom linked with a preload dependence defined by a passive leg raising test (cardiac index monitoring by a PiCCO® device; Pulsion Medical Systems, Feldkirchen, Germany). Although this study clarifies part of the genesis of hypotension during IHD, some comments can be made.
First, the authors focused on the occurrence of hypotensive episodes (an episode of systolic arterial pressure below 65 mm Hg, without duration criterion, and only the first episode of hypotension) during the IHD session. It is indeed a frequent complication that compromises the IHD session and the volume of fluid removal [2]. We question the clinical relevance of this criterion; it would have been useful to record other complications of IHD in hypovolemic patients, like supraventricular arrhythmias, elevation of the lactate level, or increase of vasopressor doses.
Second, the authors focused on preload dependence as the cause of hypotension during the IHD session, whereas many other factors such as vasoplegia or induced cardiac depression may be involved [2]. Therefore, an echocardiographic assessment before and during the episode of hypotension could have been very helpful to explore the different causes of hypotension. The value of the mitral inflow E wave to early diastolic mitral annulus velocities ratio (E/Ea ratio) is a marker of the left ventricular filling pressure which was well validated by Vignon et al. in a study of hemodialysis-induced preload reduction [3] and which has already been linked to poor tolerance of fluid removal led by furosemide or hemofiltration (area under receiver operating characteristic curves of 0.74) [4]. One study failed to identify echocardiographic parameters linked with a poor tolerance of an IHD session, but its statistical power was quite low [5].
Last, the authors propose PiCCO® parameters as predictors for hypotension associated with preload dependence during IHD in critically ill patients. Maybe a strictly non-invasive monitoring, like echocardiography, should be preferred to the PiCCO® system at this late stage of treatment (median of 18 days). Nevertheless, Bitker et al. demonstrated that the first hypotensive episode during IHD sessions is rarely associated with a preload dependence.

Authors’ response

Laurent Bitker and Jean-Christophe Richard
In their letter, Allyn et al. raised interesting issues regarding our study assessing the prevalence of preload-dependent hypotension during IHD in the intensive care unit (ICU) [1]. We acknowledged the absence of a universally accepted definition of hemodynamic tolerance and the variability of criteria found in the literature. However, we decided to identify hemodynamic intolerance by a mean arterial pressure lower than 65 mm Hg, as it is a widespread criterion used in everyday practice to adjust catecholamine dose. Nevertheless, our risk factors for hemodynamic tolerance during IHD were similar to those reported in a recent study [6], suggesting that slight differences in definition of IHD hemodynamic intolerance have little impact on study results.
Allyn et al. state their preference for echocardiography over PiCCO® to assess hemodynamic tolerance during IHD. Although we acknowledge that the two techniques may be interchangeable or complementary or both, the PiCCO® device allows continuous hemodynamic monitoring during IHD and may be used more easily.
Vignon et al. showed that the mitral inflow wave to early diastolic septal mitral annulus velocities ratio (E/E′) was related to fluid removal and cardiac preload during IHD [3]. In a selected population of 40 hemodynamically stable, ventilated acute respiratory distress syndrome patients in whom a negative fluid balance strategy could be applied, E/E′ was indeed a satisfactory predictor of poor hemodynamic tolerance to fluid depletion [4], although its relatively low specificity (0.46) suggests that factors unrelated to cardiac preload were involved. Still, another study of 54 unselected ICU patients failed to identify any echocardiographic parameter related to cardiac preload as predictors of hemodynamic tolerance of IHD [5]. In our study [1], preload dependence at IHD onset was not predictive of hypotension during IHD, and poor hemodynamic tolerance of IHD was rarely related to preload dependence, essentially in mechanically ventilated patients.
Altogether, these findings might suggest that assessment of cardiac preload before IHD (assessed by any monitoring device) predicts hemodynamic intolerance of IHD in specific ICU populations (mechanically ventilated and hemodynamically stable patients), although the specific mechanism of hypotension should prompt an evaluation of hemodynamic status (by echocardiography, PiCCO®) to re-evaluate fluid removal rate by IHD.

Acknowledgements

None.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Bitker L, Bayle F, Yonis H, Gobert F, Leray V, Taponnier R, et al. Prevalence and risk factors of hypotension associated with preload-dependence during intermittent hemodialysis in critically ill patients. Crit Care Lond Engl. 2016;20:44.CrossRef Bitker L, Bayle F, Yonis H, Gobert F, Leray V, Taponnier R, et al. Prevalence and risk factors of hypotension associated with preload-dependence during intermittent hemodialysis in critically ill patients. Crit Care Lond Engl. 2016;20:44.CrossRef
2.
Zurück zum Zitat Schortgen F. Hypotension during intermittent hemodialysis: new insights into an old problem. Intensive Care Med. 2003;29:1645–9.CrossRefPubMed Schortgen F. Hypotension during intermittent hemodialysis: new insights into an old problem. Intensive Care Med. 2003;29:1645–9.CrossRefPubMed
3.
Zurück zum Zitat Vignon P, Allot V, Lesage J, Martaillé J-F, Aldigier J-C, François B, et al. Diagnosis of left ventricular diastolic dysfunction in the setting of acute changes in loading conditions. Crit Care Lond Engl. 2007;11:R43.CrossRef Vignon P, Allot V, Lesage J, Martaillé J-F, Aldigier J-C, François B, et al. Diagnosis of left ventricular diastolic dysfunction in the setting of acute changes in loading conditions. Crit Care Lond Engl. 2007;11:R43.CrossRef
4.
Zurück zum Zitat Allyn J, Allou N, Dib M, Tashk P, Desmard M, Dufour G, et al. Echocardiography to predict tolerance to negative fluid balance in acute respiratory distress syndrome/acute lung injury. J Crit Care. 2013;28:1006–10.CrossRefPubMed Allyn J, Allou N, Dib M, Tashk P, Desmard M, Dufour G, et al. Echocardiography to predict tolerance to negative fluid balance in acute respiratory distress syndrome/acute lung injury. J Crit Care. 2013;28:1006–10.CrossRefPubMed
5.
Zurück zum Zitat Chimot L, Gacouin A, Nardi N, Gros A, Mascle S, Marqué S, et al. Can we predict poor hemodynamic tolerance of intermittent hemodialysis with echocardiography in intensive care patients? J Ultrasound Med. 2014;33:2145–50.CrossRefPubMed Chimot L, Gacouin A, Nardi N, Gros A, Mascle S, Marqué S, et al. Can we predict poor hemodynamic tolerance of intermittent hemodialysis with echocardiography in intensive care patients? J Ultrasound Med. 2014;33:2145–50.CrossRefPubMed
6.
Zurück zum Zitat du Cheyron D, Terzi N, Seguin A, Valette X, Prevost F, Ramakers M, et al. Use of online blood volume and blood temperature monitoring during haemodialysis in critically ill patients with acute kidney injury: a single-centre randomized controlled trial. Nephrol Dial Transplant. 2013;28:430–7.CrossRefPubMed du Cheyron D, Terzi N, Seguin A, Valette X, Prevost F, Ramakers M, et al. Use of online blood volume and blood temperature monitoring during haemodialysis in critically ill patients with acute kidney injury: a single-centre randomized controlled trial. Nephrol Dial Transplant. 2013;28:430–7.CrossRefPubMed
Metadaten
Titel
Preload dependence and hypotension: One of the causes and one of the consequences of poor tolerance of intermittent hemodialysis in the ICU?
verfasst von
Jérôme Allyn
Laure Corradi
Nicolas Allou
Bernard Alex Gaüzère
Publikationsdatum
01.12.2016
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2016
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-016-1331-4

Weitere Artikel der Ausgabe 1/2016

Critical Care 1/2016 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.