Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 8/2022

17.08.2021 | Knee Arthroplasty

Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty

verfasst von: Jaehyun Kim, Seongyun Park, Ji Hyun Ahn

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 8/2022

Einloggen, um Zugang zu erhalten

Abstract

Background

Recently, total knee arthroplasty (TKA) designs that allow the use of narrow-version femoral implants have been introduced to avoid femoral overhang. The purpose of this study was to investigate the frequency of the use of narrow-version femoral implants and identify the difference in radiographic parameters between using a narrow-version femoral implant and a standard-version femoral implant in TKA.

Methods

A retrospective study was conducted on 504 primary TKAs using a TKA system (Anthem or Persona) that allowed narrow-version femoral implants. Anteroposterior (AP) dimension, mediolateral (ML) dimension, and modified aspect percentage ratio (ML/AP dimension) of the distal femur in preoperative radiographs were compared between a standard-version group (n = 275) and a narrow-version group (n = 229). A cut-off value of a modified aspect percentage ratio indicating the need for a narrow-version femoral implant was determined using the receiver operating characteristic (ROC) curve.

Results

Mean ML dimension was 80.9 ± 6.1 mm in the standard-version group and 77.3 ± 4.4 mm in the narrow-version group (p < 0.001). Mean modified aspect percentage ratio was 138.8 ± 8.1% in the standard-version group and 131.7 ± 6.3% in the narrow-version group (p < 0.001). The optimum cut-off point of the modified aspect percentage ratio for narrow-version femoral implants was 135.4% (sensitivity: 72.0%; specificity: 66.7%) for Anthem and 133.3% (sensitivity: 75.9%, specificity: 76.4%) for Persona.

Conclusion

In the narrow-version femoral implant group, the ML dimension and the mean modified aspect percentage ratio were smaller than in the standard-version femoral implant group. A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. It was suggested that the cut-off point could be suggested as 135.4% for Anthem TKA design and 133.3% for Persona TKA design. These radiographic parameters are cost-effective and easily applicable for planning a TKA.A smaller modified aspect percentage ratio of the distal femur in preoperative radiographs could predict the need for narrow-version femoral implants in TKA. The cut-off point was 135.4% for Anthem TKA design and 133.3% for Persona TKA design.
Literatur
4.
Zurück zum Zitat Hitt K, Shurman JR 2nd, Greene K, McCarthy J, Moskal J, Hoeman T, Mont MA (2003) Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Joint Surg Am 85:115–122CrossRef Hitt K, Shurman JR 2nd, Greene K, McCarthy J, Moskal J, Hoeman T, Mont MA (2003) Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Joint Surg Am 85:115–122CrossRef
17.
Zurück zum Zitat Gao F, Guo W, Sun W, Li Z, Wang W, Wang B, Cheng L, Kush N (2014) Correlation between the coverage percentage of prosthesis and postoperative hidden blood loss in primary total knee arthroplasty. Chin Med J (Engl) 127:2265–2269 Gao F, Guo W, Sun W, Li Z, Wang W, Wang B, Cheng L, Kush N (2014) Correlation between the coverage percentage of prosthesis and postoperative hidden blood loss in primary total knee arthroplasty. Chin Med J (Engl) 127:2265–2269
25.
Zurück zum Zitat Bhowmik-Stoker M, Scholl L, Khlopas A, Sultan AA, Sodhi N, Moskal JT, Mont MA, Teeny SM (2018) Accurately predicting total knee component size without preoperative radiographs. Surg Technol Int 33:337–342PubMed Bhowmik-Stoker M, Scholl L, Khlopas A, Sultan AA, Sodhi N, Moskal JT, Mont MA, Teeny SM (2018) Accurately predicting total knee component size without preoperative radiographs. Surg Technol Int 33:337–342PubMed
Metadaten
Titel
Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty
verfasst von
Jaehyun Kim
Seongyun Park
Ji Hyun Ahn
Publikationsdatum
17.08.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 8/2022
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-021-04111-8

Weitere Artikel der Ausgabe 8/2022

Archives of Orthopaedic and Trauma Surgery 8/2022 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.