Skip to main content
Erschienen in: European Radiology 9/2012

01.09.2012 | Cardiac

Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study

verfasst von: Xinghua Zhang, Li Yang, Haiyue Ju, Fan Zhang, Jian Wu, Bin He, Yundai Chen

Erschienen in: European Radiology | Ausgabe 9/2012

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To evaluate the features of stent gap (SG) and the long-term impact of SG on in-stent restenosis (ISR) in patent stents.

Methods

A total of 347 consecutive patients with 781 stents who underwent MDCT were assessed for SG and ISR. Clinical and stent features were compared between the SG and non-SG groups. In the follow-up study, among 82 patients with 175 patent stents [26 assessed by conventional coronary angiography (CCA) including 6 contacted in a telephone survey, 46 assessed by computed tomography angiography (CTA) and 10 by both], the incidence of ISR was compared between stents with and without SG.

Results

Three patients and 13 stents were excluded. SG was observed in 12.5% of patients and 8.6% of stents. ISR detected by CTA was noted in 21.2% of SG, and SG accounted for 23.7% of ISR. Stent number, length, location, overlapping pattern, tortuosity and in-out angle were predisposing factors for SG. During a mean follow-up period of 15 months after detection of SG, the incidence of ISR was significantly higher in the SG group than in the non-SG group (43.8/14.9% by CCA, 33.3/10.1% by CTA and CCA).

Conclusion

Patent stents with SG detected by CTA had a higher incidence of late restenosis, indicating that long-term follow-up or further intervention is necessary.

Key Points

Coronary artery computed tomographic angiography (CTA) is increasingly used following coronary intervention.
Gaps within coronary stents detected by CTA correlate with in-stent restenosis.
Patients with stent gaps have more late restenosis at follow-up.
More attention should be given to patients with stent gaps.
Literatur
1.
Zurück zum Zitat Lee SH, Park JS, Shin DG et al (2007) Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 100:627–630PubMedCrossRef Lee SH, Park JS, Shin DG et al (2007) Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 100:627–630PubMedCrossRef
2.
Zurück zum Zitat Lee MS, Jurewitz D, Aragon J, Forrester J, Makkar RR, Kar S (2007) Stent fracture associated with drug-eluting stents: clinical characteristics and implications. Catheter Cardiovasc Interv 69:387–394PubMedCrossRef Lee MS, Jurewitz D, Aragon J, Forrester J, Makkar RR, Kar S (2007) Stent fracture associated with drug-eluting stents: clinical characteristics and implications. Catheter Cardiovasc Interv 69:387–394PubMedCrossRef
3.
Zurück zum Zitat Shaikh F, Maddikunta R, Djelmami-Hani M, Solis J, Allaqaband S, Bajwa T (2008) Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis? Catheter Cardiovasc Interv 71:614–618PubMedCrossRef Shaikh F, Maddikunta R, Djelmami-Hani M, Solis J, Allaqaband S, Bajwa T (2008) Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis? Catheter Cardiovasc Interv 71:614–618PubMedCrossRef
4.
Zurück zum Zitat Kim JS, Lee SY, Lee JM et al (2009) Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents. Coron Artery Dis 20:59–63PubMedCrossRef Kim JS, Lee SY, Lee JM et al (2009) Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents. Coron Artery Dis 20:59–63PubMedCrossRef
5.
Zurück zum Zitat Kim HS, Kim YH, Lee SW et al (2009) Incidence and predictors of drug-eluting stent fractures in long coronary disease. Int J Cardiol 133:354–358PubMedCrossRef Kim HS, Kim YH, Lee SW et al (2009) Incidence and predictors of drug-eluting stent fractures in long coronary disease. Int J Cardiol 133:354–358PubMedCrossRef
6.
Zurück zum Zitat Nakazawa G, Finn AV, Vorpahl M et al (2009) Incidence and predictors of drug-eluting stent fracture in human coronary artery—a pathologic analysis. J Am Coll Cardiol 54:1924–1931PubMedCrossRef Nakazawa G, Finn AV, Vorpahl M et al (2009) Incidence and predictors of drug-eluting stent fracture in human coronary artery—a pathologic analysis. J Am Coll Cardiol 54:1924–1931PubMedCrossRef
7.
Zurück zum Zitat Lim HB, Hur G, Kim SY et al (2008) Coronary stent fracture: detection with 64-section multidetector CT angiography in patients and in vitro. Radiology 249:810–819PubMedCrossRef Lim HB, Hur G, Kim SY et al (2008) Coronary stent fracture: detection with 64-section multidetector CT angiography in patients and in vitro. Radiology 249:810–819PubMedCrossRef
8.
Zurück zum Zitat Park KW, Park JJ, Chae IH et al (2011) Clinical characteristics of coronary drug-eluting stent fracture: insights from a two-center des registry. J Korean Med Sci 26:53–58PubMedCrossRef Park KW, Park JJ, Chae IH et al (2011) Clinical characteristics of coronary drug-eluting stent fracture: insights from a two-center des registry. J Korean Med Sci 26:53–58PubMedCrossRef
9.
Zurück zum Zitat Park SM, Kim JY, Hong BK et al (2011) Predictors of stent fracture in patients treated with closed-cell design stents: sirolimus-eluting stent and its bare-metal counterpart, the BX velocity stent. Coron Artery Dis 22:40–44PubMedCrossRef Park SM, Kim JY, Hong BK et al (2011) Predictors of stent fracture in patients treated with closed-cell design stents: sirolimus-eluting stent and its bare-metal counterpart, the BX velocity stent. Coron Artery Dis 22:40–44PubMedCrossRef
10.
Zurück zum Zitat Aoki J, Nakazawa G, Tanabe K et al (2007) Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 69:380–386. doi:10.1002/ccd.20950 PubMedCrossRef Aoki J, Nakazawa G, Tanabe K et al (2007) Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 69:380–386. doi:10.​1002/​ccd.​20950 PubMedCrossRef
11.
Zurück zum Zitat Ino Y, Toyoda Y, Tanaka A et al (2010) Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation. Am Heart J 160:e771–e779CrossRef Ino Y, Toyoda Y, Tanaka A et al (2010) Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation. Am Heart J 160:e771–e779CrossRef
13.
Zurück zum Zitat Serikawa T, Kawasaki T, Koga H et al (2011) Late catch-up phenomenon associated with stent fracture after sirolimus-eluting stent implantation: incidence and outcome. J Interv Cardiol 24:165–171PubMedCrossRef Serikawa T, Kawasaki T, Koga H et al (2011) Late catch-up phenomenon associated with stent fracture after sirolimus-eluting stent implantation: incidence and outcome. J Interv Cardiol 24:165–171PubMedCrossRef
14.
Zurück zum Zitat Hecht HS, Polena S, Jelnin V et al (2009) Stent gap by 64-detector computed tomographic angiography relationship to in-stent restenosis, fracture, and overlap failure. J Am Coll Cardiol 54:1949–1959PubMedCrossRef Hecht HS, Polena S, Jelnin V et al (2009) Stent gap by 64-detector computed tomographic angiography relationship to in-stent restenosis, fracture, and overlap failure. J Am Coll Cardiol 54:1949–1959PubMedCrossRef
15.
Zurück zum Zitat Pang JH, Kim D, Beohar N, Meyers SN, Lloyd-Jones D, Yaghmai V (2009) Detection of stent fractures: a comparison of 64-slice CT, conventional cine-angiography, and intravascular ultrasonography. Acad Radiol 16:412–417PubMedCrossRef Pang JH, Kim D, Beohar N, Meyers SN, Lloyd-Jones D, Yaghmai V (2009) Detection of stent fractures: a comparison of 64-slice CT, conventional cine-angiography, and intravascular ultrasonography. Acad Radiol 16:412–417PubMedCrossRef
16.
Zurück zum Zitat Freed MS, Safian RD (2001) Proximal vessel tortuosity and angulated lesions. In: Safian RD, Freed MS (eds) Manual of interventional cardiology, 3rd edn. Physicians's Press, Royal Oak, MI, pp 237–243 Freed MS, Safian RD (2001) Proximal vessel tortuosity and angulated lesions. In: Safian RD, Freed MS (eds) Manual of interventional cardiology, 3rd edn. Physicians's Press, Royal Oak, MI, pp 237–243
17.
Zurück zum Zitat McCollough C, Cody D, Edyvean S, Geise R (2008) The measurement, reporting, and management of radiation dose in CT. Report of AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. American Association of Physicists in Medicine, College Park, MD McCollough C, Cody D, Edyvean S, Geise R (2008) The measurement, reporting, and management of radiation dose in CT. Report of AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. American Association of Physicists in Medicine, College Park, MD
18.
Zurück zum Zitat Ino Y, Toyoda Y, Tanaka A et al (2009) Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation. Circ J 73:2036–2041PubMedCrossRef Ino Y, Toyoda Y, Tanaka A et al (2009) Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation. Circ J 73:2036–2041PubMedCrossRef
19.
Zurück zum Zitat Oncel D, Oncel G, Tastan A, Tamci B (2008) Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control. AJR Am J Roentgenol 191:56–63PubMedCrossRef Oncel D, Oncel G, Tastan A, Tamci B (2008) Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control. AJR Am J Roentgenol 191:56–63PubMedCrossRef
20.
Zurück zum Zitat Pugliese F, Weustink AC, Van Mieghem C et al (2008) Dual source coronary computed tomography angiography for detecting in-stent restenosis. Heart 94:848–854PubMedCrossRef Pugliese F, Weustink AC, Van Mieghem C et al (2008) Dual source coronary computed tomography angiography for detecting in-stent restenosis. Heart 94:848–854PubMedCrossRef
21.
Zurück zum Zitat Pflederer T, Marwan M, Renz A et al (2009) Noninvasive assessment of coronary in-stent restenosis by dual-source computed tomography. Am J Cardiol 103:812–817PubMedCrossRef Pflederer T, Marwan M, Renz A et al (2009) Noninvasive assessment of coronary in-stent restenosis by dual-source computed tomography. Am J Cardiol 103:812–817PubMedCrossRef
22.
Zurück zum Zitat Okumura M, Ozaki Y, Ishii J et al (2007) Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation. Circ J 71:1669–1677PubMedCrossRef Okumura M, Ozaki Y, Ishii J et al (2007) Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation. Circ J 71:1669–1677PubMedCrossRef
23.
Zurück zum Zitat Lee SE, Jeong MH, Kim IS et al (2009) Clinical outcomes and optimal treatment for stent fracture after drug-eluting stent implantation. J Cardiol 53:422–428PubMedCrossRef Lee SE, Jeong MH, Kim IS et al (2009) Clinical outcomes and optimal treatment for stent fracture after drug-eluting stent implantation. J Cardiol 53:422–428PubMedCrossRef
Metadaten
Titel
Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study
verfasst von
Xinghua Zhang
Li Yang
Haiyue Ju
Fan Zhang
Jian Wu
Bin He
Yundai Chen
Publikationsdatum
01.09.2012
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 9/2012
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2458-6

Weitere Artikel der Ausgabe 9/2012

European Radiology 9/2012 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.