Introduction
From hematoxylin and eosin (H&E) stains, it can be difficult to distinguish between pre-operative or curetting specimens of endocervical adenocarcinomas (ECA) and endometrial adenocarcinomas (EMA). Staging is surgical for EMA; however, for primary ECA, staging is clinical. Treatment protocols may differ substantially between them [
1,
2].
We have already learned that certain immunohistochemical markers may be helpful in distinguishing between ECA and EMA. McCluggage, et al. (2002) proposed that a panel of immunohistochemical stains, comprised of a 3-marker (ER, CEA and Vim) panel, generally results in a confident preoperative distinction between ECA and EMA[
3]. Several other studies have reported that a PR- and p16
INK4a-marker revealed a significant frequency difference (p < 0.05) between ECA and EMA. However, we were interested to discover whether ancillary PR- or p16
INK4a-marker testing could produce any supplementary benefit to the traditional 3-marker panel.
Our previous studies have already shown that ancillary p16
INK4a-marker testing does not add value to the traditional 3-marker (ER, CEA and Vim) or 4-marker (PR, ER, CEA and Vim) panel in distinguishing between these 2 gynecologic malignancies (ECA
vs. EMA)[
4,
5]. On the other hand, it is uncertain whether the performance and test effectiveness of the 4-marker (PR, ER, CEA and Vim) panel is superior to the conventional 3-marker (ER, CEA and Vim) panel in distinguishing between ECA and EMA. In order to save on the cost and economize laboratory resources, the purpose of this extension study was to examine whether the additional PR-marker can provide supplemental meaningful value to the conventional 3-marker (ER, CEA and Vim) panel, using IHC on a TMA in tissues from Taiwanese women [
6‐
12].
Discussion
Distinguishing between primary ECA and EMA before deciding the patient treatment plan is clinically important. Diagnostic difficulties may occur with some hysterectomy specimens when the tumor involves both the uterine endometrium and the endocervix. During preoperative assessment, there have been difficulties determining the primary tumor site using H&E alone. This study not only investigated the expression of 4 individual markers (PR, ER, Vim and CEA), but also evaluated whether panel performance and test effectiveness benefit from adding the PR-marker to the conventional 3-marker (ER/Vim/CEA) panel using IHC on a TMA techniques. This data will help in the referral and management of ECA and EMA cases worldwide.
There were some times when we inspected the surgical specimens during (or after) the staging procedure and found that the tumors involved both the endometrium and the endocervix. On other occasions, we obtained specimens from the biopsy of both sites of the lesions preoperatively or by fractional dilation and curettage (D&C), consisting of endocervical and endometrial curettage, which is already used as a classic standard procedure to diagnostically distinguish between EMA with (or without) cervical involvement and ECA with (or without) endometrial involvement. If the gross examination of hysterectomy specimens reveals indistinguishable primaries or the H&E histomorphology at these two adjacent lesions is similar, IHC with the traditional 3-marker (ER/Vim/CEA) or 4-marker (PR/ER/Vim/CEA) panel can be of great assistance in making the diagnostic distinction between ECA and EMA. In the 3-marker panel (ER/Vim/CEA), ECA tend to be ER-/Vim-/CEA+ and EMA tend to be ER+/Vim+/CEA-. Moreover, in the 4-marker panel (PR/ER/Vim/CEA), ECA tend to be PR-/ER-/Vim-/CEA+ and EMA tend to be PR+/ER+/Vim+/CEA-[
4,
5,
7‐
12]. Within a tumor immunoprofile of either ECA or EMA, unexpected "aberrant" expressions may occur with any one or more of the 3- or 4-marker panels discussed. In this study, the IHC results of all the 4 individual markers (PR, ER, Vim and CEA), as well as their respective 3-marker (ER/Vim/CEA) or 4-marker (PR/ER/Vim/CEA) panels, showed significant differences in expression frequencies between the two types of adenocarcinomas (ECA
vs. EMA).
We used the immunohistochemistry (IHC) on a tissue microarray (TMA) technique to investigate multiple specimens simultaneously in this extension study. This approach results in a dramatic reduction of time and cost compared with conventional histopathologic research techniques. TMA has become a popular tool for tissue-based research because it allows for the massive acceleration of studies correlating molecular in situ findings with clinico-pathological information. TMA has become specifically useful in surveys of tumor populations where it can be utilized to analyze the functions of specific markers or panels in neoplastic human tissues in both a comprehensive and efficient manner. On the other hand, the limitation of TMAs seems to be the insufficiency to demonstrate heterogeneity of the tumor because of the small size of tissue used; however, sampling with optimal cores in TMA was enough to show accuracies compared with whole mount sections. Studies have shown that increasing the number of cores results in only a slightly higher rate of validity and the noteworthy shortcomings of extra labor for constructing arrays, sample interpretation and data processing[
22,
23]. All 38 specimens were validated in this study.
IHC is no longer a qualitative immunoassay used only in research, but it is being increasingly employed as a semiquantitative or quantitative mode for the assessment of the presence of some therapeutic and prognostic biomarkers. Despite lacking a clear definition, many published papers have referred to the German Immunohistochemical Scoring System, as well as the term "semiquantative" to depict the scoring system for IHC interpretation. In fact, the "semiquantitative" scoring mechanism has generally been defined as the final immunoreactive score (IRS) is equal to the percentage of the extent of "quantitative" positive areas multiplied by the "qualitative" average of staining intensity. This "semiquantitative" scoring method has been reproduced and widely used in many laboratories[
13,
16,
24‐
28].
There are a variety of IHC scoring methods including computer-based plans presented in literature, and there still seems to be no generally accepted protocol in research laboratories and clinical practices for rating and scoring immunostaining results. Comparing commercially derived computer-based programs with the conventional analyses by pathologists, there is still a lack of optimized and standardized IHC scoring algorithms. As a result, the objective accuracy did not significantly improve the clinical outcome measures. This study uses a widely accepted semi-quantitative scoring system for interpretation[
13,
16‐
20,
24‐
28].
In other studies, it has been reported that IHC stained positive for the PR-marker in 89–96% of EMA, in contrast to 4–21% of ECA. IHC stained positive for the ER-marker in 67–97% of EMA, in contrast to 4–20% of ECA. IHC stained positive for the Vim-marker in 62–93% of EMA, in contrast to 7–14% of ECA; and IHC stained positive for the CEA-marker in 14–27% of EMA, in contrast to 62–93% of ECA.[
4,
5,
7‐
12] In addition, we have already reported that when using the 3-marker (ER/Vim/CEA) panel, IHC stained positive for the ER-marker in 75.0% of EMA, in contrast to 14.3% of ECA. IHC stained positive for the Vim-marker in 66.7% of EMA, in contrast to 7.1% of ECA; and IHC stained positive for the CEA-marker in 16.7% of EMA, in contrast to 71.4% of ECA in our previous study[
4,
5]. In this study, we also found that IHC stained positive for the PR-marker in 58.3% of EMA, in contrast to 21.4% of ECA. The IHC results of these 4 individual markers and their respective 4-marker panel (PR/ER/Vim/CEA) revealed a significant diagnostic distinction between these 2 gynecologic malignancies (ECA
vs. EMA) in this series of 14 cases of ECA and 24 cases of EMA.
McCluggage, et al. (2002) has already proposed that the conventional IHC 3-marker panel (ER, Vim and CEA) generally allows for a confident preoperative distinction between a primary endometrial and endocervical adenocarcinoma[
3]. In this study, our purpose was to assess whether the 4-marker (PR/ER/Vim/CEA) panel containing PR could provide a more favorable performance than the conventional 3-marker (ER/Vim/CEA) panel in distinguishing between primary ECA and EMA.
In accordance with previous reports, we defined the typical EC-type immunoprofile as ER-/Vim-/CEA+, and the typical EM-type immunoprofile as ER+/Vim+/CEA-, using the conventional 3-marker (ER/Vim/CEA) panel. We also defined the typical EC-type immunoprofile as PR-/ER-/Vim-/CEA+, and the typical EM-type immunoprofile as PR+/ER+/Vim+/CEA-, using the 4-marker (PR/ER/Vim/CEA) panel[
4,
5,
7‐
12].
In this study, with regard to the typical immunoprofiles in the conventional 3-marker (ER/Vim/CEA) panel, the sensitivity and negative predictive value (NPV) were 57.1% and 79.3% in ECA and 45.8% and 51.9% in EMA. However, considering the 4-marker (PR/ER/Vim/CEA) panel, the sensitivity and the negative predictive value (NPV) remained at 57.1% and 79.3% in ECA, but decreased to 37.5% and 48.3% in EMA with the typical EM-type immunoprofile. All these results indicated a high false-negative rate. If the staining results do not match up with the typical EC-type or EM-type immunoprofile, despite the PR-staining result, there is a high probability that the corresponding ECA or EMA tumor diagnosis will be doubtful and inconclusive. The low sensitivity and NPV of both panels are the limiting factors for the application of either the 3 or 4-marker immunoprofiles as a screening tool for ECA and EMA.
Moreover, regarding the 3-marker (ER/Vim/CEA) panel, the specificity and positive predictive value (PPV) were 95.8% and 88.9% in ECA and 100% and 100% in EMA. However, considering the 4-marker panel (PR/ER/Vim/CEA), the specificity and positive predictive value (PPV) remained the same at 95.8% and 88.9% in ECA and 100% and 100% in EMA. All these results indicated a low false-positive rate. If the staining result matches up with the typical EC-type or EM-type immunoprofile, despite the PR staining result, there is a high probability that the corresponding ECA or EMA tumor diagnosis will be accurate and conclusive. The high specificity and PPV of both panels are the promising factors for the application of either the 3 or 4-marker immunoprofiles as a confirmatory tool for the diagnosis of ECA and EMA.
Above all, accuracy means the degree of veracity. When using both 3-marker and 4-marker panels with typical EC-type (ER-/Vim-/CEA+ or PR-/ER-/Vim-/CEA+) immunoprofiles in definitively diagnosing primary ECA, both panels had the same accuracy rate (80.0% vs. 80.0%). On the other hand, when using both 3-marker and 4-marker panels with typical EM-type (ER+/Vim+/CEA- or PR+/ER+/Vim+/CEA-) immunoprofiles in definitively diagnosing primary EMA, the 3-marker panel had only a slightly higher accuracy rate compared with the 4-marker panel (68.6% vs. 65.7%).
It has been reported that most endocervical adenocarcinomas (ECAs) contain high-risk human papillomavirus (HPV) DNA, whereas endometrial adenocarcinomas (EMAs) rarely do. However, HPV data was not included in this report because we have already shown that the expression of p16
INK4a protein is significantly higher in endocervical adenocarcinomas than in endometrial adenocarcinomas, and the p16
INK4a marker seems to be a sensitive surrogate for the presence of HPV infection[
29]. In this study, we did not include the p16
INK4a-marker as an essential constituent in the panel along with ER/PR/Vim/CEA because our previous report demonstrated that adding the p16
INK4a to the conventional 3-marker (ER/Vim/CEA) or 4-marker (PR/ER/Vim/CEA) panel did not improve the panel performances in the diagnostic discrimination between ECA and EMA using the same IHC on a TMA techniques[
4,
5]. In addition, the interpretation of IHC data with p16
INK4a staining results is complicated because of the unclear biological significance of cytoplasmic staining and the lack of a universally accepted algorithm in the scoring methodology[
30,
31]. Some researchers regard cytoplasmic reactivity as an unexpected, unspecific event and consider nucleic p16
INK4a labeling in tumor cells to be only positive[
16,
32‐
35]. Others have stated, on the contrary, that both nucleic and cytoplasmic immunoreactivities in tumor cells are characteristic and are indeed due to p16
INK4a expression [
36‐
40]. The knowledge about the functional meaning of cytoplasmic p16
INK4a expression is still limited and further large-scale studies are needed on various human tissues and tumors.
In summary, it is known that each of the four monoclonal antibodies directed against PR, ER, Vim, and CEA as well as a pre-existing panel, comprised of either 3 members (ER, Vim, CEA) or 4 members (PR, ER, Vim, CEA), could help in distinguishing between adenocarcinomas of endocervical origin and adenocarcinomas of endometrial origin. This study has demonstrated similar results to other studies in that a typical EC-type immunoprofile tends to be ER-/Vim-/CEA+ in ECA, whereas a typical EM-type immunoprofile tends to be ER+/Vim+/CEA- in EMA. The PR-marker tends to show negative expression in ECA, but positive expression in EMA. After assessing the panel performance and test effectiveness for sensitivity, specificity, NPV, PPV and accuracy of both 3- and 4-marker panels, we found that there was no supplemental benefit of adding the PR-marker to the conventional 3-marker (ER/Vim/CEA) panel in distinguishing between ECA and EMA. Despite the limited number of cases, the data provides significant and valuable references for further investigation to determine other useful immunoprofiles or panels that will definitively distinguish between ECA and EMA.
Competing interests
The authors declare that they have no competing interests.
Authors' contributions
CPH, LFK performed experiments and wrote the manuscript. MYL performed the statistical analysis. KCC, CLL, PHW, YST, CLK participated in its design and coordination. TSW edited the draft manuscript. All authors read and approved the final manuscript.