Skip to main content
Erschienen in: Surgical Endoscopy 12/2010

01.12.2010

Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair

verfasst von: Eric D. Jenkins, Victoria Yom, Lora Melman, L. Michael Brunt, J. Christopher Eagon, Margaret M. Frisella, Brent D. Matthews

Erschienen in: Surgical Endoscopy | Ausgabe 12/2010

Einloggen, um Zugang zu erhalten

Abstract

Background

The purpose of this study was to characterize the adhesion characteristics of absorbable- and nonabsorbable-barrier-coated meshes and to report adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair.

Methods

Under an IRB-approved protocol, patients undergoing laparoscopic re-exploration after prior intraperitoneal mesh placement were prospectively graded intraoperatively for adhesion tenacity (0-4), adhesion surface area (0 = 0%, 10 = 100%), and ratio of adhesiolysis time to mesh surface area (min/cm2). Adhesiolysis-related complications were also recorded. Data are given as mean ± SD. Statistical significance (P < 0.05) was determined using the t test and Fisher’s exact test.

Results

From March 2006 to March 2009, 69 patients underwent laparoscopic surgery after prior intraperitoneal mesh placement for ventral hernia repair. Previous meshes were absorbable-barrier-coated mesh (n = 18), permanent-barrier composite mesh [Composix® (n = 17)], permanent-barrier noncomposite mesh [DualMesh® (n = 14)], uncoated polypropylene mesh (n = 12), and biologic mesh (n = 8). Indications for laparoscopic re-exploration were recurrent ventral hernia (n = 58), chronic pain (n = 3), cholecystectomy (n = 3), parastomal hernia (n = 2), small bowel obstruction (n = 1), nephrectomy (n = 1), and Nissen fundoplication (n = 1). Adhesions to DualMesh were less tenacious (P < 0.05) compared to all other meshes. Surface area of adhesions to DualMesh were less (P < 0.05) than to Composix and to uncoated polypropylene mesh, but not to absorbable-barrier-coated and biologic meshes. Adhesiolysis time:mesh surface area was less (P < 0.05) for DualMesh compared to Composix, uncoated polypropylene, and biologic mesh, but not to absorbable-barrier-coated mesh. Adhesiolysis-related complications occurred in two (16.7%) (P = ns) patients with uncoated polypropylene mesh, one cystotomy and one enterotomy; both were repaired laparoscopically. There were two (16.7%) (P = ns) conversions to an open procedure: one converted patient had Composix (6.7%) and one had absorbable-barrier-coated mesh (5.9%). There were no adhesiolysis-related complications with these meshes. There were no adhesiolysis-related complications or conversions to open in the DualMesh or biologic mesh groups.

Conclusions

Adhesion characteristics of mesh placed intraperitoneally and adhesiolysis-related complications during laparoscopic re-exploration after ventral hernia repair are associated with unique properties of the mesh and/or barrier.
Literatur
1.
Zurück zum Zitat Rives J, Pire JC, Flament JB, Palot JP, Body C (1985) Treatment of large eventrations. New therapeutic indications apropos of 322 cases. Chirurgie 111:215–225PubMed Rives J, Pire JC, Flament JB, Palot JP, Body C (1985) Treatment of large eventrations. New therapeutic indications apropos of 322 cases. Chirurgie 111:215–225PubMed
2.
Zurück zum Zitat Stoppa RE (1989) The treatment of complicated groin and incisional hernias. World J Surg 13:545–554CrossRefPubMed Stoppa RE (1989) The treatment of complicated groin and incisional hernias. World J Surg 13:545–554CrossRefPubMed
3.
Zurück zum Zitat Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578–583PubMed Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578–583PubMed
4.
Zurück zum Zitat LeBlanc KA, Booth WV (1993) Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 3:39–41PubMed LeBlanc KA, Booth WV (1993) Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 3:39–41PubMed
5.
Zurück zum Zitat Pierce RA, Spitler JA, Frisella MA, Matthews BD, Brunt LM (2006) Pooled data analysis of laparoscopic vs. open ventral hernia repair: 14 years of patient data accrual. Surg Endosc 21:378–386CrossRefPubMed Pierce RA, Spitler JA, Frisella MA, Matthews BD, Brunt LM (2006) Pooled data analysis of laparoscopic vs. open ventral hernia repair: 14 years of patient data accrual. Surg Endosc 21:378–386CrossRefPubMed
6.
Zurück zum Zitat Heniford BT, Park A, Ramshaw BJ, Voeller G (2003) Laparoscopic repair of ventral hernias: nine year experience with 850 consecutive hernias. Ann Surg 238:391–400PubMed Heniford BT, Park A, Ramshaw BJ, Voeller G (2003) Laparoscopic repair of ventral hernias: nine year experience with 850 consecutive hernias. Ann Surg 238:391–400PubMed
7.
Zurück zum Zitat Halm JA, de Wall LL, Steyerberg EW, Jeekel J, Lange JF (2007) Intraperitoneal polypropylene mesh hernia repair complicates subsequent abdominal surgery. World J Surg 31:423–429CrossRefPubMed Halm JA, de Wall LL, Steyerberg EW, Jeekel J, Lange JF (2007) Intraperitoneal polypropylene mesh hernia repair complicates subsequent abdominal surgery. World J Surg 31:423–429CrossRefPubMed
8.
Zurück zum Zitat Garrard CL, Clements RH, Nanney L, Davidson JM, Richards WO (1999) Adhesion formation is reduced after laparoscopic surgery. Surg Endosc 13(1):10–13CrossRefPubMed Garrard CL, Clements RH, Nanney L, Davidson JM, Richards WO (1999) Adhesion formation is reduced after laparoscopic surgery. Surg Endosc 13(1):10–13CrossRefPubMed
9.
Zurück zum Zitat Van Der Krabben AA, Dijkstra FR, Niewenhuijzen M, Reijnen MM, Schaapveld M, Van Goor H (2000) Morbidity and mortality of inadvertent enterotomy during adhesiotomy. Br J Surg 87(4):467–471CrossRef Van Der Krabben AA, Dijkstra FR, Niewenhuijzen M, Reijnen MM, Schaapveld M, Van Goor H (2000) Morbidity and mortality of inadvertent enterotomy during adhesiotomy. Br J Surg 87(4):467–471CrossRef
10.
Zurück zum Zitat Luijendijk RW, de Lange DC, Wauters CC, Hop WC, Duron JJ, Pailler JL, Camprodon BR, Holmdahl L, van Geldorp HJ, Jeekel J (1996) Foreign material in postoperative adhesions. Ann Surg 223:242–248CrossRefPubMed Luijendijk RW, de Lange DC, Wauters CC, Hop WC, Duron JJ, Pailler JL, Camprodon BR, Holmdahl L, van Geldorp HJ, Jeekel J (1996) Foreign material in postoperative adhesions. Ann Surg 223:242–248CrossRefPubMed
11.
Zurück zum Zitat Gray SH, Vick CC, Graham LA, Finan KR, Neumayer LA, Hawn MT (2008) Risk of complications from enterotomy or unplanned bowel resection during elective hernia repair. Arch Surg 143(6):582–586CrossRefPubMed Gray SH, Vick CC, Graham LA, Finan KR, Neumayer LA, Hawn MT (2008) Risk of complications from enterotomy or unplanned bowel resection during elective hernia repair. Arch Surg 143(6):582–586CrossRefPubMed
12.
Zurück zum Zitat Pierce RA, Perrone JM, Nimeri A, Sexton JA, Walcutt J, Frisella MM, Matthews BD (2009) 120-day comparative analysis of adhesion grade and quantity, mesh contraction, and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Innov 16:46–54CrossRefPubMed Pierce RA, Perrone JM, Nimeri A, Sexton JA, Walcutt J, Frisella MM, Matthews BD (2009) 120-day comparative analysis of adhesion grade and quantity, mesh contraction, and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Innov 16:46–54CrossRefPubMed
13.
Zurück zum Zitat van’t Riet M, van Steenwijk PJ, Bonthuis F, Marquet RL, Steyerberg EW, Jeekel J, Bonjer HJ (2003) Prevention of adhesion to prosthetic mesh: comparison of different barriers using an incisional hernia model. Ann Surg 237:123–128CrossRef van’t Riet M, van Steenwijk PJ, Bonthuis F, Marquet RL, Steyerberg EW, Jeekel J, Bonjer HJ (2003) Prevention of adhesion to prosthetic mesh: comparison of different barriers using an incisional hernia model. Ann Surg 237:123–128CrossRef
14.
Zurück zum Zitat Matthews BD, Mostafa G, Carbonell AM, Joels CS, Kercher KW, Austin C, Norton HJ, Heniford BT (2005) Evaluation of adhesion formation and host tissue response to intra-abdominal polytetrafluoroethylene mesh and composite prosthetic mesh. J Surg Res 123(2):227–234CrossRefPubMed Matthews BD, Mostafa G, Carbonell AM, Joels CS, Kercher KW, Austin C, Norton HJ, Heniford BT (2005) Evaluation of adhesion formation and host tissue response to intra-abdominal polytetrafluoroethylene mesh and composite prosthetic mesh. J Surg Res 123(2):227–234CrossRefPubMed
15.
Zurück zum Zitat Koehler RH, Begos D, Berger D, Carey S, LeBlanc K, Park A, Ramshaw B, Smoot R, Voeller G (2003) Minimal adhesions to ePTFE mesh after laparoscopic ventral hernia incisional hernia repair: re-operative findings in 65 cases. JSLS 7:335–340PubMed Koehler RH, Begos D, Berger D, Carey S, LeBlanc K, Park A, Ramshaw B, Smoot R, Voeller G (2003) Minimal adhesions to ePTFE mesh after laparoscopic ventral hernia incisional hernia repair: re-operative findings in 65 cases. JSLS 7:335–340PubMed
16.
Zurück zum Zitat Arnaud JP, Hennekinne-Mucci S, Pessaux P, Tuech JJ, Aube C (2003) Ultrasound detection of visceral adhesion after intraperitoneal ventral hernia treatment: a comparative study of protected versus unprotected meshes. Hernia 7:85–88CrossRefPubMed Arnaud JP, Hennekinne-Mucci S, Pessaux P, Tuech JJ, Aube C (2003) Ultrasound detection of visceral adhesion after intraperitoneal ventral hernia treatment: a comparative study of protected versus unprotected meshes. Hernia 7:85–88CrossRefPubMed
17.
Zurück zum Zitat Balique JG, Benchetrit S, Bouillot JL, Flament JB, Gouillat C, Jarsaillon P, Lepère M, Mantion G, Arnaud JP, Magne E, Brunetti F (2005) Intraperitoneal treatment of incisional and umbilical hernias using an innovative composite mesh: four-year results of a prospective multicenter clinical trial. Hernia 9:68–74CrossRefPubMed Balique JG, Benchetrit S, Bouillot JL, Flament JB, Gouillat C, Jarsaillon P, Lepère M, Mantion G, Arnaud JP, Magne E, Brunetti F (2005) Intraperitoneal treatment of incisional and umbilical hernias using an innovative composite mesh: four-year results of a prospective multicenter clinical trial. Hernia 9:68–74CrossRefPubMed
Metadaten
Titel
Prospective evaluation of adhesion characteristics to intraperitoneal mesh and adhesiolysis-related complications during laparoscopic re-exploration after prior ventral hernia repair
verfasst von
Eric D. Jenkins
Victoria Yom
Lora Melman
L. Michael Brunt
J. Christopher Eagon
Margaret M. Frisella
Brent D. Matthews
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
Surgical Endoscopy / Ausgabe 12/2010
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-010-1076-0

Weitere Artikel der Ausgabe 12/2010

Surgical Endoscopy 12/2010 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.