Background

Current guidelines of Food and Drug Administration for the evaluation of SPECT myocardial perfusion imaging (MPI) in clinical trials recommend independent visual interpretation by multiple experts. Few studies have addressed whether quantitative SPECT MPI assessment would be more reproducible for this application.

Methods and Results

We studied 31 patients (age 68 ± 13, 25 male) with abnormal stress MPI who underwent repeat exercise (n = 11) or adenosine (n = 20) MPI within 9-22 months (mean 14.9 ± 3.8 months) and had no interval revascularization or myocardial infarction and no change in symptoms, stress type, rest or stress ECG, or clinical response to stress on the second study. Visual interpretation per FDA Guidance used 17-segment, 5-point scoring by two independent expert readers with overread of discordance by a third expert, and percent myocardium abnormal was derived from normalized summed scores. The quantitative magnitude of perfusion abnormality was assessed by the total perfusion deficit (TPD), expressing stress, rest, and ischemic perfusion abnormality. High linear correlations were observed between visual and quantitative size of stress, rest, and ischemic defects (R = 0.94, 0.92, 0.84). Correlations of two tests were higher by quantitative than by visual methods for stress (R = 0.97 vs R = 0.91, P = 0.03) and rest defects (R = 0.94 vs R = 0.82, P = 0.03), respectively, and statistically similar for ischemic defects (R = 0.84 vs R = 0.70, P = ns).

Conclusions

In stable patients having serial SPECT MPI, quantification is more reproducible than visual for magnitude of perfusion abnormality, suggesting its superiority for use in randomized clinical trials and monitoring the effects of therapy in an individual patient.
Literatur
1.
Zurück zum Zitat Mahmarian JJ, Shaw LJ, Filipchuk NG, et al. A multinational study to establish the value of early adenosine technetium-99m sestamibi myocardial perfusion imaging in identifying a low-risk group for early hospital discharge after acute myocardial infarction. J Am Coll Cardiol 2006;48:2448-57.PubMedCrossRef Mahmarian JJ, Shaw LJ, Filipchuk NG, et al. A multinational study to establish the value of early adenosine technetium-99m sestamibi myocardial perfusion imaging in identifying a low-risk group for early hospital discharge after acute myocardial infarction. J Am Coll Cardiol 2006;48:2448-57.PubMedCrossRef
2.
Zurück zum Zitat Shaw LJ, Berman DS, Maron DJ, et al. Optimal medical therapy with or without percutaneous coronary intervention to reduce ischemic burden: Results from the Clinical Outcomes Utilizing Revascularization and Aggressive Drug Evaluation (COURAGE) trial nuclear substudy. Circulation 2008;117:1283-91.PubMedCrossRef Shaw LJ, Berman DS, Maron DJ, et al. Optimal medical therapy with or without percutaneous coronary intervention to reduce ischemic burden: Results from the Clinical Outcomes Utilizing Revascularization and Aggressive Drug Evaluation (COURAGE) trial nuclear substudy. Circulation 2008;117:1283-91.PubMedCrossRef
3.
Zurück zum Zitat Dangas G, Stone GW, Weinberg MD, et al. Contemporary outcomes of rescue percutaneous coronary intervention for acute myocardial infarction: Comparison with primary angioplasty and the role of distal protection devices (EMERALD trial). Am Heart J 2008;155:1090-6.PubMedCrossRef Dangas G, Stone GW, Weinberg MD, et al. Contemporary outcomes of rescue percutaneous coronary intervention for acute myocardial infarction: Comparison with primary angioplasty and the role of distal protection devices (EMERALD trial). Am Heart J 2008;155:1090-6.PubMedCrossRef
4.
Zurück zum Zitat Schwartz RG, Pearson TA, Kalaria VG, et al. Prospective serial evaluation of myocardial perfusion and lipids during the first six months of pravastatin therapy: Coronary artery disease regression single photon emission computed tomography monitoring trial. J Am Coll Cardiol 2003;42:600-10.PubMedCrossRef Schwartz RG, Pearson TA, Kalaria VG, et al. Prospective serial evaluation of myocardial perfusion and lipids during the first six months of pravastatin therapy: Coronary artery disease regression single photon emission computed tomography monitoring trial. J Am Coll Cardiol 2003;42:600-10.PubMedCrossRef
6.
Zurück zum Zitat Mahmarian JJ, Moye LA, Verani MS, Bloom MF, Pratt CM. High reproducibility of myocardial perfusion defects in patients undergoing serial exercise thallium-201 tomography. Am J Cardiol 1995;75:1116-9.PubMedCrossRef Mahmarian JJ, Moye LA, Verani MS, Bloom MF, Pratt CM. High reproducibility of myocardial perfusion defects in patients undergoing serial exercise thallium-201 tomography. Am J Cardiol 1995;75:1116-9.PubMedCrossRef
7.
Zurück zum Zitat Wackers FJ. Science, art, and artifacts: How important is quantification for the practicing physician interpreting myocardial perfusion studies? J Nucl Cardiol 1994;1:S109-17.PubMedCrossRef Wackers FJ. Science, art, and artifacts: How important is quantification for the practicing physician interpreting myocardial perfusion studies? J Nucl Cardiol 1994;1:S109-17.PubMedCrossRef
8.
Zurück zum Zitat Berman DS, Germano G. Interpretation and reporting of gated myocardial perfusion SPECT. In: Germano G, Berman DS, editors. Clinical gated cardiac SPECT. 2nd ed. Oxford, UK: Blackwell Publishing; 2006. p. 139-71. Berman DS, Germano G. Interpretation and reporting of gated myocardial perfusion SPECT. In: Germano G, Berman DS, editors. Clinical gated cardiac SPECT. 2nd ed. Oxford, UK: Blackwell Publishing; 2006. p. 139-71.
9.
Zurück zum Zitat Abidov A, Bax JJ, Hayes SW, et al. Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD. J Nuc Med 2004;45:1999-2007. Abidov A, Bax JJ, Hayes SW, et al. Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD. J Nuc Med 2004;45:1999-2007.
10.
Zurück zum Zitat Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation 2003;107:2900-7.PubMedCrossRef Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation 2003;107:2900-7.PubMedCrossRef
11.
Zurück zum Zitat Germano G, Kavanagh PB, Su HT, et al. Automatic reorientation of three-dimensional, transaxial myocardial perfusion SPECT images [see comments]. J Nucl Med 1995;36:1107-14.PubMed Germano G, Kavanagh PB, Su HT, et al. Automatic reorientation of three-dimensional, transaxial myocardial perfusion SPECT images [see comments]. J Nucl Med 1995;36:1107-14.PubMed
12.
Zurück zum Zitat Mazzanti M, Germano G, Kiat H, et al. Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT. J Am Coll Cardiol 1996;27:1612-20.PubMedCrossRef Mazzanti M, Germano G, Kiat H, et al. Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT. J Am Coll Cardiol 1996;27:1612-20.PubMedCrossRef
13.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.PubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.PubMed
14.
Zurück zum Zitat Slomka PJ, Nishina H, Berman DS, et al. Automated quantification of myocardial perfusion SPECT using simplified normal limits. J Nucl Cardiol 2005;12:66-77.PubMedCrossRef Slomka PJ, Nishina H, Berman DS, et al. Automated quantification of myocardial perfusion SPECT using simplified normal limits. J Nucl Cardiol 2005;12:66-77.PubMedCrossRef
15.
Zurück zum Zitat Prigent FM, Berman DS, Elashoff J, et al. Reproducibility of stress redistribution thallium-201 SPECT quantitative indexes of hypoperfused myocardium secondary to coronary artery disease. Am J Cardiol 1992;70:1255-63.PubMedCrossRef Prigent FM, Berman DS, Elashoff J, et al. Reproducibility of stress redistribution thallium-201 SPECT quantitative indexes of hypoperfused myocardium secondary to coronary artery disease. Am J Cardiol 1992;70:1255-63.PubMedCrossRef
16.
Zurück zum Zitat Bland JM, Altman DG. Applying the right statistics: Analyses of measurement studies. Ultrasound Obstet Gynecol 2003;22:85-93.PubMedCrossRef Bland JM, Altman DG. Applying the right statistics: Analyses of measurement studies. Ultrasound Obstet Gynecol 2003;22:85-93.PubMedCrossRef
17.
Zurück zum Zitat Danias PG, Ahlberg AW, Travin MI, et al. Visual assessment of left ventricular perfusion and function with electrocardiography-gated SPECT has high intraobserver and interobserver reproducibility among experienced nuclear cardiologists and cardiology trainees. J Nucl Cardiol 2002;9:263-70.PubMedCrossRef Danias PG, Ahlberg AW, Travin MI, et al. Visual assessment of left ventricular perfusion and function with electrocardiography-gated SPECT has high intraobserver and interobserver reproducibility among experienced nuclear cardiologists and cardiology trainees. J Nucl Cardiol 2002;9:263-70.PubMedCrossRef
18.
Zurück zum Zitat Cerqueira MD, Nguyen P, Staehr P, Underwood R, Iskandrian AE. Effects of age, gender, obesity, and diabetes on the efficacy and safety of the selective A2A agonist regadenoson versus adenosine in myocardial perfusion imaging. J Am Coll Cardiol Img 2008;1:307-16. Cerqueira MD, Nguyen P, Staehr P, Underwood R, Iskandrian AE. Effects of age, gender, obesity, and diabetes on the efficacy and safety of the selective A2A agonist regadenoson versus adenosine in myocardial perfusion imaging. J Am Coll Cardiol Img 2008;1:307-16.
19.
Zurück zum Zitat Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2000;2:271-8.PubMedCrossRef Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2000;2:271-8.PubMedCrossRef
20.
Zurück zum Zitat Slomka PJ, Nishina H, Berman DS, et al. Automatic quantification of myocardial perfusion stress-rest change: A new measure of ischemia. J Nucl Med 2004;45:183–91.PubMed Slomka PJ, Nishina H, Berman DS, et al. Automatic quantification of myocardial perfusion stress-rest change: A new measure of ischemia. J Nucl Med 2004;45:183–91.PubMed
Metadaten
Titel
Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis
verfasst von
Daniel S. Berman, MD
Xingping Kang, MD
Heidi Gransar, MS
James Gerlach, CNMT
John D. Friedman, MD
Sean W. Hayes, MD
Louise E. J. Thomson, MBChB
Rory Hachamovitch, MD, MSc
Leslee J. Shaw, PhD
Piotr J. Slomka, PhD
Ling De Yang, MD
Guido Germano, PhD
Publikationsdatum
01.02.2009
Verlag
Springer-Verlag
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 1/2009
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-008-9018-0

Weitere Artikel der Ausgabe 1/2009

Journal of Nuclear Cardiology 1/2009 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.