Reliability of non-contrast magnetic resonance angiography-derived aortic diameters in Marfan patients: comparison of inner vs. outer vessel wall measurements

verfasst von: Julius Matthias Weinrich, Maxim Avanesov, Alexander Lenz, Enver Tahir, Frank-Oliver Henes, Bjoern Philip Schoennagel, Meike Rybczinsky, Gerhard Adam, Yskert von Kodolitsch, Peter Bannas

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 8/2020

Abstract

Aortic diameter measurements play a crucial role for the indication of aortic root surgery in Marfan patients. However, for magnetic resonance angiography (MRA)-derived measurements, there is no consensus on whether the aortic wall should be included or excluded in the aortic diameter. The purpose of this retrospective study was to compare the reliability of non-contrast bright blood MRA aortic inner-to-inner and outer-to-outer edge measurements in patients with Marfan syndrome. Forty Marfan patients underwent ECG-gated balanced steady-state free-precession MRA of the aorta at 1.5 T. Two readers independently performed inner and outer measurements at different aortic levels. They rated the image quality of the delineation of both inner and outer vessel wall edges on a four-point scale. MRA-derived diameters of the sinuses of Valsalva were compared with echocardiography-derived diameters. Aortic vessel wall delineation score was rated higher at all levels for inner than for outer vessel walls (p < 0.001). Inter- and intraobserver variances of aortic measurements were smaller for inner-to-inner measurements at the sinuses of Valsalva, sinotubular junction and ascending aorta (p < 0.03). There was a difference of 1.1 ± 2.3 mm for inner MRA measurements (p = 0.014) and 6.9 ± 3.1 mm for outer MRA measurements (p < 0.001) when compared to echocardiographic leading-edge measurements. Inner-to-inner vessel wall diameter measurements in non-contrast bright blood MRA provide more reliable diameters when compared to outer-to-outer vessel wall measurements of the aortic root. Therefore, we propose to rely on inner rather than outer aortic wall measurements in non-contrast-MRA when monitoring aortic diameters in patients with Marfan syndrome.

Introduction

Marfan syndrome is a hereditary connective tissue disorder caused by mutations in the FBN1 gene encoding the protein fibrilin-1 [1]. The prevalence of this autosomal-dominant inherited disease is one in 500–10,000 individuals [2, 3]. Progressive dilation of the aortic root is the most common cardiovascular complication of Marfan syndrome [1, 4]. The connective tissue disorder affects different parts of the human body, including heart, blood vessels, lungs, skin, bones, joints, and eyes [3, 5]. Aortic root aneurysms may cause aortic dissection and represent the main cause of death in Marfan syndrome [1, 4, 6, 7].
Timely diagnosis of aortic root aneurysms in Marfan patients allows for prophylactic aortic surgery to evade the risk of dissection [8, 9]. Current guidelines recommend prophylactic aortic root replacement at a threshold diameter of 50 mm. In case of high risk for rupture e.g. due to a growing rate of at least 5 mm per year, elective surgery is recommended at an external diameter of 50 mm [10] or even less (45 mm) in patients with risk factors.
Several biomarkers for progression of aortic dilatation, such as transforming growth factor-β and fibrillin-1 fragments, have been investigated, but none are routinely used in clinical practice [11]. Four-dimensional phase contrast magnetic resonance imaging (4D flow MRI) is an advanced imaging technique, which allows for acquisition of morphological images and velocity data. 4D flow MRI thus enables visualization and quantification of complex blood flow patterns in the thoracic aorta [12, 13]. Recent 4D flow MRI studies showed promising results in Marfan patients supporting the notion that pathological blood flow profiles may contribute to aneurysm formation [14, 15]. Further longitudinal studies are needed to assess the potential of 4D flow MRI as a potential imaging biomarker for progression of aortic dilatation.
However, these imaging biomarkers are not yet established in clinical routine or current guidelines. Therefore, absolute aortic diameter and the aortic growth rate remain the most important predictors for aortic dissection in Marfan patients [16].
As a result, annual cross-sectional imaging is mandatory for monitoring aortic root dimensions in Marfan patients to determine if and when aortic root replacement is indicated [17, 18]. Imaging modalities that allow precise, reproducible, operator-independent and standardized assessment of the aorta are crucial in the follow-up of Marfan patients.
Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) are available for non-invasive imaging of the aortic root [10]. However, echocardiography cannot assess the entire aorta and is highly operator-dependent while MDCT uses ionizing radiation and requires application of iodinated contrast [19]. Magnetic resonance angiography (MRA) does not require ionizing radiation or iodinated contrast. Excellent image quality covering the entire aorta can be acquired in an observer-independent fashion [20, 21]. Therefore, MRA is recommended for imaging of the entire thoracic aorta in patients with congenital heart disease.
Unfortunately, there is no consensus, on whether the aortic wall should be included or excluded in the aortic diameter measurements when using MRA for monitoring of aortic root dimensions in patients with genetic aortic disease such as Marfan syndrome. The guidelines for the diagnosis and management of thoracic aortic disease recommend outer-to-outer edge measurements, based on the idea that inner-to-inner edge measurements may not accurately reflect the true diameter in case of mural atherosclerotic plaques, thrombi or aortic wall inflammation [10]. In contrast, the Society for Cardiovascular Magnetic Resonance board of trustee’s task force on standardized image interpretation recommends reporting the inner diameter of the aorta [22]. Consequently, recent studies regarding MRI-derived aortic measurements used different approaches: some authors measured inner-to-inner diameters [20], other authors measured outer-to-outer diameters [21, 23] and some authors failed to detail their measurement approach [24].
Hence, there is a lack of both: consensus among different guidelines as well as systematic studies regarding the issue whether the aortic wall should be included in magnetic resonance angiography (MRA)-derived aortic diameter measurements. Therefore, we aimed to compare the reliability of aortic inner-to-inner and outer-to-outer edge measurements of non-contrast MRA in Marfan patients.

Material and methods

Study population

We included forty consecutive adult patients (18 males, 22 females; age range 18–57 years; mean 31.2 ± 12 years; median 27 years) with confirmed Marfan syndrome prior to aortic surgery in this retrospective study. All patients underwent both non-contrast MRA and echocardiography on the same day between January and July 2015. Marfan diagnosis was established according to the latest Ghent nosology as well as genetic analyses with sequencing of the FBN1 gene [3, 25]. We excluded Marfan patients younger than 18 years or with prior aortic root surgery. The local institutional review board approved our retrospective single-centre study and waived the requirement for informed consent.

Non-contrast MRA

Non-contrast balanced steady-state free precession (bSSFP) MRA was performed using a 1.5 T system equipped with a five-channel coil for cardiac imaging (Achieva, Philips Medical Systems). ECG leads were placed in a typical manner for cardiac triggering. Scout images were acquired in axial, coronal and sagittal orientation. ECG-gated non-contrast 2D MRA with sensitivity encoding (SENSE) was acquired in the transversal and coronal plane as well as in para-sagittal orientation aligned with the curvature of the aortic arch [26, 27]. Image acquisition was triggered to the end-diastolic phase of the cardiac cycle to minimize motion artefacts during end-expiratory breath-hold. Image parameters of para-sagittal orientation were as follows: TR/TE, 3.5/1.75 ms; flip angle, 90°; field of view, 450 mm (FH) × 390 mm (AP) × 102 mm (RL); acquired matrix, 268 × 234; acquired voxel size: 1.68 mm × 1.66 mm × 10 mm; reconstructed voxel size 1.4 mm × 1.4 mm × 10 mm; slice thickness, 10 mm with a gap of − 5 mm (i.e. 5 mm overlap of slices for gapless coverage); SENSE factor: 2. Number of slices: 20; acquisition time 18–22 s for each stack, depending on the individual heart rate and breath-holding capability.

MR image evaluation

Anonymized non-contrast MRA images were presented in random order to two radiologists with four and six years of experience in cardiovascular imaging, respectively. All images were interpreted on state-of-the-art RIS/PACS workstations (Centricity™ RIS-i 4.2 Plus, GE General Electric Company).
Image quality assessments and diameter measurements were performed at the sinuses of Valsalva, sinotubular junction, ascending aorta at the level of the pulmonary trunk, aortic arch between the branching of left carotid and left subclavian artery, and descending aorta at level of the pulmonary trunk as illustrated in Fig. 1 [10].
Image quality of para-sagittal non-contrast MRA images was assessed by both readers individually on a four-point scale regarding sharp anatomic delineation of inner and outer edges of the vessel walls at all levels [21]:
  • 1 = excellent definition with sharp delineation and high contrast
  • 2 = well defined with good contrast
  • 3 = poorly defined with low contrast
  • 4 = not visualized
Visibility of a segment was rated to be of diagnostically acceptable image quality if the score was ≤ 2. Thus, readers were confident that diameter measurements could be performed with diagnostic confidence from the visualized segment. Further, both readers analysed the aortic lumen for thrombi to prevent biased image quality evaluation and diameter measurements.
Diameter measurements were performed by both readers individually at all levels on identically orientated para-sagittal non-contrast MRA source images perpendicular to the blood-filled lumen. Readers were free to choose appropriate slices displaying the maximal profile of the aorta from the stacks of para-sagittal images. No secondary multiplanar reformations (MPR) were used for the comparison of the two measurement techniques. Using the identically oriented para-sagittal images avoided user influence introduced by individually performed MPRs and allowed for assessment of only the differences that are attributed to the different measurement techniques [23, 26, 27].
Inner-to-inner and outer-to-outer diameters were measured three times: for assessment of intraobserver agreement, reader 1 performed two measurements, with an interval of four weeks between the first and second measurement. For assessment of interobserver agreement, reader 2 performed a third measurement. Inner-to-inner and outer-to-outer diameter measurements were performed in two different reading sessions with a two-week time lag between assessments of the same case to avoid recall bias.

Echocardiography

All Marfan patients underwent a 2D transthoracic echocardiographic examination (TEE) on the same day of the non-contrast MRA study as part of their routine screening at our University Heart Centre. Two readers with ≥ 10 years of echocardiographic experience evaluated TTE recordings. End-diastolic aortic root diameters were determined using the leading-edge method in the parasternal long axis view at the level of the sinuses of Valsalva [28]. Echocardiography was performed with a commercially available ultrasound system (EPIQ CVx, Philips, Andover, MA, USA). Aortic diameters at the level of sinuses of Valsalva measured by echocardiography were compared to measurements obtained from bSSFP MRA.

Statistical analysis

Means and standard deviations of subjective image quality scoring were calculated for inner and outer vessel wall edges images for both readers and for the average of both readers. We do report these results as means ± standard deviations because they are more informative than medians and interquartile ranges. Comparison of the subjective image quality of the anatomic delineation of inner and outer vessel wall edges was performed using the Wilcoxon signed-rank test for paired samples. A weighted k statistic was performed to assess interobserver variability. A k value of 0.81–1.00 indicated excellent agreement; a k value of 0.61- 0.80, substantial agreement; a k value of 0.41–0.60, moderate agreement; a k value of 0.21–0.40, fair agreement; and a k value of 0.00–0.20, slight agreement [29].
Intraclass correlation coefficients (ICC) were calculated to assess intraobserver and interobserver correlation of measurements obtained from inner-to-inner and outer-to-outer measurements. Bland–Altman analysis was used to assess intra- and interobserver agreement between measurements obtained from inner-to-inner and outer-to-outer measurements. A two-sided t test was performed for comparison of mean differences (bias) and F-test for comparison of variances.
Inner-to-inner diameter measurements were compared with outer-to-outer diameter measurements using Bland–Altman analysis. Both inner-to-inner and outer-to-outer diameter measurements were compared with echocardiographic measurements using Bland–Altman analysis. A two-sided paired t test was used to determine significant differences between measurements obtained from 2D bSSFP MRA and echocardiography.
P-values < 0.05 were considered as statistically significant. Statistical analysis was performed using MedCalc for Windows, version 12.7.8.0 (MedCalc Software).

Results

All non-contrast MRA studies were performed with sufficient diagnostic image quality and no rating of 4 (= not visualized) was given. Also, for inner-to-inner measurements only scores of 1 and 2 were given. None of the patients had an aortic dissection. None of the patients had mural thrombi and all studies were included in the evaluation.

MRA image quality of vessel wall edges

Non-contrast MRA image quality ratings of the anatomical delineation of the vessel wall edges were significantly higher for inner vessel wall edges compared to outer vessel wall edges at all levels of measurement (all p < 0.001) (Fig. 2 and Table 1).
Table 1
Qualitative image quality scores for delineation of outer vs. inner vessel walls of the thoracic aorta
Aortic level
Average
Reader 1
Reader 2
Weighted κ (95% CI)
Sinuses of Valsalva
 Inner
1.5 ± 0.5
1.5 ± 0.6
1.5 ± 0.6
0.86 (0.70–1.0)
 Outer
2.1 ± 0.7
2.1 ± 0.7
2.1 ± 0.8
0.78 (0.62–0.93)
 P-value (t-test)
 < 0.001
 < 0.001
 < 0.001
NA
Sinotubular junction
 Inner
1.6 ± 0.5
1.6 ± 0.5
1.5 ± 0.5
0.74 (0.53–0.95)
 Outer
2.3 ± 0.6
2.3 ± 0.7
2.3 ± 0.6
0.62 (0.42–0.82)
 P-value (t-test)
 < 0.001
 < 0.001
 < 0.001
NA
Ascending aorta
 Inner
1.3 ± 0.5
1.3 ± 0.6
1.3 ± 0.6
0.82 (0.65–0.99)
 Outer
2.1 ± 0.6
2.1 ± 0.6
2.2 ± 0.6
0.79 (0.57–1.0)
 P-value (t-test)
 < 0.001
 < 0.001
 < 0.001
NA
Mid-aortic arch
 Inner
1.2 ± 0.4
1.3 ± 0.5
1.2 ± 0.4
0.86 (0.69–1.0)
 Outer
2.1 ± 0.6
2.1 ± 0.6
2.1 ± 0.6
0.79 (0.60–0.97)
 P-value (t-test)
 < 0.001
 < 0.001
 < 0.001
NA
Descending aorta
 Inner
1.2 ± 0.4
1.2 ± 0.5
1.1 ± 0.3
0.85 (0.65–1.0)
 Outer
2.4 ± 0.5
2.4 ± 0.5
2.4 ± 0.5
0.84 (0.66–1.0)
 P-value (t-test)
 < 0.001
 < 0.001
 < 0.001
NA
T-test was performed for comparison of mean differences. Significant differences are in bold (significant at p < 0.05)
A four point-scale regarding sharp anatomic delineation of inner and outer edges of the vessel was used: 1 = excellent definition with sharp delineation and high contrast; 2 = well defined with good contrast; 3 = poorly defined with low contrast; 4 = not visualized
NA  not  applicable

Intraobserver agreement of MRA-derived measurements

Intraobserver correlation was good for both methods at all measurement levels (all r > 0.8) (Table 2).
Table 2
Intraobserver variance of inner vs. outer aortic measurements as described by Bland and Altman
 
Sinuses of Valsalva
Sinotubular junction
Ascending aorta
Aortic arch
Descending Aorta
Outer-outer edge
 Mean difference (mm)
0.80
0.40
0.13
0.65
0.40
 Limits of agreement (mm)
− 4.2 to 5.8
− 4.0 to 4.8
− 3.5 to 3.7
− 3.1 to 4.3
− 3.6 to 4.4
 SD (mm)
2.5
2.2
1.9
2
2.1
 Variance (mm2)
6.4
5.0
3.4
3.9
4.2
 ICC (r)
0.91
0.89
0.95
0.83
0.83
Inner-inner edge
 Mean difference (mm)
0.43
0.10
0.52
0.35
− 0.15
 Limits of agreement (mm)
− 3.1 to 3.9
− 3.0 to 3.2
− 2 to 3.1
− 3.1 to 3.8
− 4.4 to 4.2
 SD (mm)
1.8
1.6
1.3
1.7
2.2
 Variance (mm2)
3.1
2.5
1.7
3.1
4.8
 ICC (r)
0.95
0.95
0.97
0.86
0.86
 P value (t test)
 < 0.001
 < 0.001
 < 0.001
 < 0.001
 < 0.001
 P value (F test)
0.03
0.03
0.03
0.46
0.65
Intraclass correlation coefficient (ICC) values are given for outer and inner measurements. T-test was performed for comparison of mean differences and F-test for comparison of variances
Significant differences are in bold (significant at p < 0.05)
Bland–Altman analyses revealed a significantly smaller (p < 0.001) intraobserver bias for inner-to-inner measurements at the sinuses of Valsalva (mean difference: 0.4 mm) compared to outer-to-outer measurements (mean difference: 0.8 mm) (Fig. 3a, b). The intraobserver bias was significantly smaller for inner-to-inner measurements compared to outer-to-outer measurements also at all other measurement levels (all p < 0.001) (Table 2).
Bland–Altman analyses display a significantly smaller (p = 0.03) intraobserver variance for inner-to-inner measurements at the sinuses of Valsalva (95% limits of agreement: − 3.1 to 3.9 mm) compared to outer-to-outer measurements (95% limits of agreement: − 4.2 to 5.8 mm) (Fig. 3a, b, Supplemental Fig. 1). The intraobserver variance was significantly smaller for inner-to-inner measurements compared to outer-to-outer measurements also at the sinotubular junction (p = 0.03) and the ascending aorta (p = 0.03). There was no significant difference in intraobserver variances at the level of the aortic arch (p = 0.46) and the descending aorta (p = 0.65) (Table 2).

Interobserver agreement of MRA-derived measurements

Interobserver correlation was higher for inner-to-inner measurements (all r > 0.8) than for outer-to-outer measurements, except for the aortic arch and descending aorta where interobserver correlation was comparable to outer-to-outer measurements (Table 3).
Table 3
Interobserver variance of inner vs. outer aortic measurements as described by Bland and Altman
 
Sinuses of Valsalva
Sinotubular junction
Ascending aorta
Aortic arch
Descending aorta
Outer-outer edge
 Mean difference (mm)
− 0.93
0.50
− 0.60
0.40
0.30
 Limits of agreement (mm)
− 8.9 to 7.1
− 7.5 to 8.5
− 11.4 to 10.2
− 3.0 to 3.8
− 3.7 to 3.3
 SD (mm)
4.1
4.1
5.5
1.8
1.8
 Variance (mm2)
16.9
16.8
30.1
3.1
3.1
 ICC (r)
0.75
0.67
0.48
0.83
0.88
Inner-inner edge
 Mean difference (mm)
− 0.43
0.18
0.15
− 0.05
0.20
 Limits of agreement (mm)
− 4.2 to 3.3
− 5.6 to 5.9
− 4.7 to 4.4
− 2.7 to 2.8
− 2.7 to 2.5
 SD (mm)
1.9
2.9
2.3
1.4
1.3
 Variance (mm2)
3.7
8.8
5.4
2.0
1.7
 ICC (r)
0.94
0.82
0.89
0.89
0.92
 P value (t test)
 < 0.001
 < 0.001
 < 0.001
 < 0.001
 < 0.001
 P value (F test)
 < 0.001
 < 0.05
 < 0.001
0.16
0.07
Intraclass correlation coefficient (ICC) values are given for outer and inner measurements. T-test was performed for comparison of mean differences and F-test for comparison of variances
Significant differences are in bold (significant at p < 0.05)
Bland–Altman analyses revealed a significantly smaller (p < 0.001) interobserver bias for inner-to-inner measurements at the sinuses of Valsalva (mean difference: − 0.4 mm) compared to outer-to-outer measurements (mean difference: − 0.9 mm) (Fig. 3c, d). The interobserver bias was significantly smaller for inner-to-inner measurements compared to outer-to-outer measurements also at all other measurement levels (all p < 0.001) (Table 3).
Bland–Altman analyses further revealed a significantly smaller (p = 0.001) interobserver variance for inner-to-inner measurements at the sinuses of Valsalva (95% limits of agreement: − 4.2 to 3.3 mm) compared to outer-to-outer measurements (95% limits of agreement: − 9 to 7.1 mm) (Fig. 3c, d). The interobserver variance was significantly smaller for inner-to-inner measurements compared to outer-to-outer measurements also at the sinotubular junction (p < 0.05) and the ascending aorta (p < 0.001). There was no significant difference in interobserver variances at the level of the aortic arch (p = 0.16) and the descending aorta (p = 0.07) (Table 3).

Comparison of MRA-derived inner vs. outer aortic measurements

Bland–Altman analyses of the measured diameters at the sinuses of Valsalva revealed a significantly higher diameter of outer measurements compared to inner diameter measurements with a mean of − 5.8 ± 2.6 mm (p < 0.001) Fig. 4). The measured aortic diameter was significantly higher for outer measurements compared to inner measurements also at all other measurement levels (all p < 0.001) (Table 4).
Table 4
Comparison of aortic diameters as determined by inner and outer measurements
 
Sinuses of Valsalva
Sinotubular junction
Ascending aorta
Aortic arch
Descending aorta
Inner-inner (mm)
36.1 ± 5.4
27.4 ± 4.7
25.8 ± 4.7
20.7 ± 2.9
20.5 ± 3.1
Outer-outer (mm)
42.3 ± 5.5
32.2 ± 4.6
30.6 ± 4.6
25.1 ± 3.0
25.3 ± 3.4
Mean difference (mm)
− 6.2 ± 2.4
− 4.8 ± 1.6
− 4.9 ± 2.6
− 4.4 ± 1.9
− 4.8 ± 1.5
P-value (t-test)
 < 0.001
 < 0.001
 < 0.001
 < 0.001
 < 0.001
T-test was performed for comparison of mean differences
Significant differences are in bold (significant at p < 0.05)
The mean difference between both methods ranged from − 4.4 ± 1.9 mm in the aortic arch to − 6.2 ± 2.4 mm at the sinuses of Valsalva (Table 4).

Comparison of MRA-derived inner and outer measurements vs. echocardiography

Bland–Altman analyses of the measured diameters at the sinuses of Valsalva revealed a significantly higher diameter of MRA-derived outer-to-outer measurements (35 ± 5 mm) when compared to echocardiographic measurements (42 ± 6 mm), resulting in a mean difference of 6.9 ± 3.1 mm (p < 0.001). MRA-derived inner-to-inner measurements at the sinuses of Valsalva (36 ± 5 mm) were also significantly higher (p = 0.014) when compared to echocardiographic measurements (35 ± 5 mm), but with a smaller mean difference of 1.1 ± 2.3 mm (Fig. 5).

Impact on clinical decision-making

Both readers correctly identified aortic root aneurysms ≥ 45 mm in three of the 40 included patients (8%) with additional risk factors using MRA-derived inner-to-inner measurements (Fig. 6). These findings were correlated with echocardiography and all three patients underwent prophylactic aortic root replacement to evade the risk of dissection. Using MRA, both readers measured comparable inner diameters in all three patients for the sinuses of Valsalva (differences: 0, 0, and 1 mm, respectively) and deviating outer diameters (differences: 2, 4, and 4 mm, respectively). Compared with diameters obtained by echocardiography there was a bigger difference for outer diameters than inner diameters (4 and 6 vs. 1 and 2 mm; 6 and 10 vs. 2 and 2 mm; 2 and 6 vs. 1 and 1 mm).

Discussion

We successfully demonstrated that inner-to-inner measurements are more reliable than outer-to-outer edge measurements when using ECG-gated non-contrast MRA for monitoring of aortic diameters in Marfan patients.
Our results revealed that inner aortic vessel wall edges show a clear demarcation due to the high contrast between the hypointense vessel wall and the hyperintense vessel lumen. In contrast, outer vessel wall edges show a significantly worse demarcation, which is explained by the hypointense vessel wall that is surrounded by also hypointense perivascular tissue, resulting in a more difficult discrimination. The better delineation of the inner vessel wall edges translated in significantly smaller intra- and interobserver biases of the entire thoracic aorta and significantly smaller variances of measurements for the aortic root.
There were no significant differences of variances between inner and outer measurements at the level of the aortic arch and the descending aorta, which might be explained by a clear demarcation of the aortic arch and the straight course of the descending aorta. This observation is in accordance with a recent study demonstrating higher correlation of measurements at the level of the aortic arch and descending aorta compared to other aortic levels [30].
As expected, inner-to-inner diameter measurements resulted in significantly smaller diameters when compared to outer-to-outer measurements. At the sinuses of Valsalva this diameter difference amounted to a statistically significant difference of ~ 6 mm. A diameter difference of 6 mm is clinically relevant, particularly in Marfan patients approaching the threshold diameter for aortic root surgery, thereby impacting on indication of elective aortic root surgery.
Both inner and outer para-sagittal MRA-derived measurements of the sinuses of Valsalva were significantly higher when compared to parasternal long axis echocardiographic leading-edge measurements. Expectedly, the difference between echocardiographic leading-edge diameter and MRA-derived outer diameters (~ 7 mm) was higher and clinically more relevant than the difference from MRA-derived inner diameters (~ 1 mm). The remaining small difference between MRA-derived inner-to-inner diameters and echocardiographic leading-edge diameters is explained by the different angle of incidence and imaging modalities [31]. Taken together, MRA-derived inner-to-inner measurements show a smaller variance and higher agreement with echocardiographic measurements than outer-to-outer measurements. These results regarding aortic diameter assessment are clinically relevant as they are critical for surgical decisions in Marfan patients.
Our study emphasizes the importance of unified standardization regarding the inclusion of the aortic wall in aortic diameter measurements for non-contrast MRA in Marfan patients. According to our results, we propose a standardized report of the internal aortic diameter for non-contrast MRA in Marfan patients. Our findings support the recommendation of the Society for Cardiovascular Magnetic Resonance board of trustee’s task force on standardized image interpretation in cardiovascular magnetic resonance. Of note, the guidelines for the diagnosis and management of thoracic aortic disease recommend the opposite approach. However, both guidelines state that the external diameter is useful to avoid confounding by mural thrombi [10, 22], as it is commonly found in the abdominal but not in the ascending aorta [10, 28]. This is in accordance with our study: none of the included patients had mural thrombi. Therefore, we do advocate internal measurements of the thoracic aorta in Marfan patients when using MRA.

Study limitations

There are certain limitations to this study. First, measurements were only performed in para-sagittal planes of source images (aligned with the curvature of the aortic arch along the flow axis of the aorta) without using secondary multiplanar reformations. However, using identically orientated source images for both inner-to-inner and outer-to-outer measurements minimizes possible bias introduced by suboptimal secondary reformations and subsequent measurement errors. Assessment of identical source images allows for true assessment of the influence of inner edge vs. outer edge measurement technique on measurement agreement. We acknowledge that secondary reformations such as double oblique techniques may result in different absolute diameters [32]. However, such secondary reformations also introduce operator-dependent biases. Using the identically oriented para-sagittal images avoided user influence introduced by individually performed MPRs and allowed for assessment of only the differences that are attributed to the different imaging and triggering techniques [23, 26, 27]. In every day clinical practice, we use and recommend secondary reformations and/or dedicated cardiac cine MRI in Marfan patients reaching critical aortic root diameters. Secondly, we did not assess other MRA techniques such as other non-contrast 3D-MRA sequences or contrast-enhanced MRA. Another limitation is that we only used bright-blood MR sequences. Dark-blood MR sequences allow for better delineation of the aortic wall and may be better suited for measurements of outer aortic diameter measurements [33, 34]. Future studies addressing the comparison of these MR sequences are warranted.

Conclusions

In conclusion, inner-to-inner vessel wall measurements in non-contrast MRA provide more reliable diameters when compared to outer-to-outer vessel wall measurements of the aortic root. Therefore, we propose to rely on inner rather than outer aortic wall measurements in non-contrast MRA when monitoring aortic diameters in patients with Marfan syndrome or other thoracic aortic disease.

Acknowledgements

Open Access funding provided by Projekt DEAL.

Compliance with ethical standards

Conflict of interest

The authors report no relationships that could be construed as a conflict of interest.

Ethical approval

The local institutional review board approved our retrospective single-centre study and waived the requirement for informed consent. The study protocol complied with the Declaration of Helsinki and was part of routinely performed non-invasive imaging methods.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Judge DP, Dietz HC (2005) Marfan’s syndrome. Lancet 366:1965–1976CrossRef Judge DP, Dietz HC (2005) Marfan’s syndrome. Lancet 366:1965–1976CrossRef
2.
Zurück zum Zitat Groth KA, Hove H, Kyhl K et al (2015) Prevalence, incidence, and age at diagnosis in Marfan Syndrome. Orphanet J Rare Dis 10:153CrossRef Groth KA, Hove H, Kyhl K et al (2015) Prevalence, incidence, and age at diagnosis in Marfan Syndrome. Orphanet J Rare Dis 10:153CrossRef
3.
Zurück zum Zitat von Kodolitsch Y, De Backer J, Schüler H, Bannas P, Behzadi C, Bernhardt AM et al (2014) Perspectives on the revised Ghent criteria for the diagnosis of Marfan syndrome. Appl Clin Genet 8:137–155 von Kodolitsch Y, De Backer J, Schüler H, Bannas P, Behzadi C, Bernhardt AM et al (2014) Perspectives on the revised Ghent criteria for the diagnosis of Marfan syndrome. Appl Clin Genet 8:137–155
4.
Zurück zum Zitat Murdoch JL, Walker BA, Halpern BL, Kuzma JW, McKusick VA (1972) Life expectancy and causes of death in the Marfan syndrome. N Engl J Med 286:804–808CrossRef Murdoch JL, Walker BA, Halpern BL, Kuzma JW, McKusick VA (1972) Life expectancy and causes of death in the Marfan syndrome. N Engl J Med 286:804–808CrossRef
5.
Zurück zum Zitat Sheikhzadeh S, De Backer J, Gorgan NR, Rybczynski M, Hillebrand M, Schüler H et al (2014) The main pulmonary artery in adults: a controlled multicenter study with assessment of echocardiographic reference values, and the frequency of dilatation and aneurysm in Marfan syndrome. Orphanet J Rare Dis 9:203CrossRef Sheikhzadeh S, De Backer J, Gorgan NR, Rybczynski M, Hillebrand M, Schüler H et al (2014) The main pulmonary artery in adults: a controlled multicenter study with assessment of echocardiographic reference values, and the frequency of dilatation and aneurysm in Marfan syndrome. Orphanet J Rare Dis 9:203CrossRef
6.
Zurück zum Zitat Holloway BJ, Rosewarne D, Jones RG (2014) Imaging of thoracic aortic disease. Br J Radiol 84:S338–S354CrossRef Holloway BJ, Rosewarne D, Jones RG (2014) Imaging of thoracic aortic disease. Br J Radiol 84:S338–S354CrossRef
7.
Zurück zum Zitat den Hartog AW, Franken R, de Witte P et al (2013) Aortic disease in patients with Marfan syndrome: aortic volume assessment for surveillance. Radiology 269:370–377CrossRef den Hartog AW, Franken R, de Witte P et al (2013) Aortic disease in patients with Marfan syndrome: aortic volume assessment for surveillance. Radiology 269:370–377CrossRef
8.
Zurück zum Zitat von Kodolitsch Y, Rybczynski M, Vogler M, Mir T, Schüler H, Kutsche K et al (2016) The role of the multidisciplinary health care team in the management of patients with Marfan syndrome. J Multidiscip Healthc 9:587–614CrossRef von Kodolitsch Y, Rybczynski M, Vogler M, Mir T, Schüler H, Kutsche K et al (2016) The role of the multidisciplinary health care team in the management of patients with Marfan syndrome. J Multidiscip Healthc 9:587–614CrossRef
9.
Zurück zum Zitat Jondeau G, Detaint D, Tubach F et al (2012) Aortic event rate in the Marfan population: a cohort study. Circulation 125:226–232CrossRef Jondeau G, Detaint D, Tubach F et al (2012) Aortic event rate in the Marfan population: a cohort study. Circulation 125:226–232CrossRef
10.
Zurück zum Zitat Hiratzka LF, Bakris GL, Beckman JA et al (2010) 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the diagnosis and management of patients with thoracic aortic disease. A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. J Am Coll Cardiol 55:e27–e129CrossRef Hiratzka LF, Bakris GL, Beckman JA et al (2010) 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the diagnosis and management of patients with thoracic aortic disease. A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine. J Am Coll Cardiol 55:e27–e129CrossRef
11.
Zurück zum Zitat Hofmann Bowman MA, Eagle KA, Milewicz DM (2019) Update on clinical trials of Losartan with and without β-blockers to block aneurysm growth in patients with Marfan syndrome. JAMA Cardiol 4:702–706CrossRef Hofmann Bowman MA, Eagle KA, Milewicz DM (2019) Update on clinical trials of Losartan with and without β-blockers to block aneurysm growth in patients with Marfan syndrome. JAMA Cardiol 4:702–706CrossRef
13.
Zurück zum Zitat Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlhäll C-J, Ebbers T et al (2015) 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson 17:72CrossRef Dyverfeldt P, Bissell M, Barker AJ, Bolger AF, Carlhäll C-J, Ebbers T et al (2015) 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson 17:72CrossRef
14.
Zurück zum Zitat Geiger J, Hirtler D, Gottfried K, Rahman O, Bollache E, Barker AJ et al (2017) Longitudinal evaluation of aortic hemodynamics in marfan syndrome: new insights from a 4D flow cardiovascular magnetic resonance multi-year follow-up study. J Cardiovasc Magn Reson 19:1–11CrossRef Geiger J, Hirtler D, Gottfried K, Rahman O, Bollache E, Barker AJ et al (2017) Longitudinal evaluation of aortic hemodynamics in marfan syndrome: new insights from a 4D flow cardiovascular magnetic resonance multi-year follow-up study. J Cardiovasc Magn Reson 19:1–11CrossRef
15.
Zurück zum Zitat Wang H-H, Chiu H-H, Tseng W-YI, Peng H-H (2016) Does altered aortic flow in marfan syndrome relate to aortic root dilatation? J Magn Reson Imaging 44:500–508CrossRef Wang H-H, Chiu H-H, Tseng W-YI, Peng H-H (2016) Does altered aortic flow in marfan syndrome relate to aortic root dilatation? J Magn Reson Imaging 44:500–508CrossRef
16.
Zurück zum Zitat Weinrich JM, Lenz A, Girdauskas E, Adam G, von Kodolitsch Y, Bannas P (2019) Current and emerging imaging techniques in patients with genetic aortic syndromes. Rofo 192:50–58PubMed Weinrich JM, Lenz A, Girdauskas E, Adam G, von Kodolitsch Y, Bannas P (2019) Current and emerging imaging techniques in patients with genetic aortic syndromes. Rofo 192:50–58PubMed
17.
Zurück zum Zitat von Kodolitsch Y, Robinson PN, Berger J (2014) When should surgery be performed in Marfan syndrome and other connective tissue disorders to protect against type A dissection? In: Bonsen R, et al. (eds) Controversies in aortic dissection and aneurysmal disease. Springer, London, pp 17–47 von Kodolitsch Y, Robinson PN, Berger J (2014) When should surgery be performed in Marfan syndrome and other connective tissue disorders to protect against type A dissection? In: Bonsen R, et al. (eds) Controversies in aortic dissection and aneurysmal disease. Springer, London, pp 17–47
18.
Zurück zum Zitat von Kodolitsch Y, Rybczynski M, Detter C, Robinson PN (2008) Diagnosis and management of Marfan syndrome. Future Cardiol 4:85–96CrossRef von Kodolitsch Y, Rybczynski M, Detter C, Robinson PN (2008) Diagnosis and management of Marfan syndrome. Future Cardiol 4:85–96CrossRef
19.
Zurück zum Zitat Hanneman K, Chan FP, Mitchell RS, Miller DC, Fleischmann D (2016) Pre- and postoperative imaging of the aortic root. Radiographics 36:19–37CrossRef Hanneman K, Chan FP, Mitchell RS, Miller DC, Fleischmann D (2016) Pre- and postoperative imaging of the aortic root. Radiographics 36:19–37CrossRef
20.
Zurück zum Zitat von Knobelsdorff-Brenkenhoff F, Gruettner H, Trauzeddel RF, Greiser A, Schulz-Menger J (2014) Comparison of native high-resolution 3D and contrast-enhanced MR angiography for assessing the thoracic aorta. Eur Heart J Cardiovasc Imaging 15:651–658CrossRef von Knobelsdorff-Brenkenhoff F, Gruettner H, Trauzeddel RF, Greiser A, Schulz-Menger J (2014) Comparison of native high-resolution 3D and contrast-enhanced MR angiography for assessing the thoracic aorta. Eur Heart J Cardiovasc Imaging 15:651–658CrossRef
21.
Zurück zum Zitat Krishnam MS, Tomasian A, Malik S, Desphande V, Laub G, Ruehm SG (2009) Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases. Eur Radiol 20:1311–1320CrossRef Krishnam MS, Tomasian A, Malik S, Desphande V, Laub G, Ruehm SG (2009) Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases. Eur Radiol 20:1311–1320CrossRef
22.
Zurück zum Zitat Schulz-Menger J, Bluemke DA, Bremerich J et al (2013) Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post Processing. J Cardiovasc Magn Reson 15:35CrossRef Schulz-Menger J, Bluemke DA, Bremerich J et al (2013) Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post Processing. J Cardiovasc Magn Reson 15:35CrossRef
23.
Zurück zum Zitat Bannas P, Groth M, Rybczynski M, Sheikhzadeh S, von Kodolitsch Y, Graessner J et al (2013) Assessment of aortic root dimensions in patients with suspected Marfan syndrome: intraindividual comparison of contrast-enhanced and non-contrast magnetic resonance angiography with echocardiography. Int J Cardiol 167:190–196CrossRef Bannas P, Groth M, Rybczynski M, Sheikhzadeh S, von Kodolitsch Y, Graessner J et al (2013) Assessment of aortic root dimensions in patients with suspected Marfan syndrome: intraindividual comparison of contrast-enhanced and non-contrast magnetic resonance angiography with echocardiography. Int J Cardiol 167:190–196CrossRef
24.
Zurück zum Zitat Groth M, Henes FO, Müllerleile K, Bannas P, Adam G, Regier M (2012) Accuracy of thoracic aortic measurements assessed by contrast enhanced and unenhanced magnetic resonance imaging. Eur J Radiol 81:762–766CrossRef Groth M, Henes FO, Müllerleile K, Bannas P, Adam G, Regier M (2012) Accuracy of thoracic aortic measurements assessed by contrast enhanced and unenhanced magnetic resonance imaging. Eur J Radiol 81:762–766CrossRef
25.
Zurück zum Zitat Loeys BL, Dietz HC, Braverman AC et al (2010) The revised Ghent nosology for the Marfan syndrome. J Med Genet 47:476–485CrossRef Loeys BL, Dietz HC, Braverman AC et al (2010) The revised Ghent nosology for the Marfan syndrome. J Med Genet 47:476–485CrossRef
27.
Zurück zum Zitat Veldhoen S, Behzadi C, Derlin T, Rybczinsky M, von Kodolitsch Y, Sheikhzadeh S et al (2014) Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography. Eur Radiol 25:872–882CrossRef Veldhoen S, Behzadi C, Derlin T, Rybczinsky M, von Kodolitsch Y, Sheikhzadeh S et al (2014) Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography. Eur Radiol 25:872–882CrossRef
28.
Zurück zum Zitat Goldstein SA, Evangelista A, Abbara S, Arai A, Asch FM, Badano LP et al (2015) Multimodality imaging of diseases of the thoracic aorta in adults: from the American Society of Echocardiography and the European Association of Cardiovascular Imaging: endorsed by the Society of Cardiovascular Computed Tomography and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr 28:119–182CrossRef Goldstein SA, Evangelista A, Abbara S, Arai A, Asch FM, Badano LP et al (2015) Multimodality imaging of diseases of the thoracic aorta in adults: from the American Society of Echocardiography and the European Association of Cardiovascular Imaging: endorsed by the Society of Cardiovascular Computed Tomography and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr 28:119–182CrossRef
29.
Zurück zum Zitat Kundel HL, Polansky M (2003) Measurement of observer agreement. Radiology 228:303–308CrossRef Kundel HL, Polansky M (2003) Measurement of observer agreement. Radiology 228:303–308CrossRef
30.
Zurück zum Zitat Asch FM, Yuriditsky E, Prakash SK, Roman MJ, Weinsaft JW, Weissman G et al (2016) The need for standardized methods for measuring the aorta: multimodality core lab experience from the GenTAC registry. JACC Cardiovasc Imaging 9:219–226CrossRef Asch FM, Yuriditsky E, Prakash SK, Roman MJ, Weinsaft JW, Weissman G et al (2016) The need for standardized methods for measuring the aorta: multimodality core lab experience from the GenTAC registry. JACC Cardiovasc Imaging 9:219–226CrossRef
31.
Zurück zum Zitat Amsallem M, Ou P, Milleron O, Henry-Feugeas M-C, Detaint D, Arnoult F et al (2015) Comparative assessment of ascending aortic aneurysms in Marfan patients using ECG-gated computerized tomographic angiography versus trans-thoracic echocardiography. Int J Cardiol 184:22–27CrossRef Amsallem M, Ou P, Milleron O, Henry-Feugeas M-C, Detaint D, Arnoult F et al (2015) Comparative assessment of ascending aortic aneurysms in Marfan patients using ECG-gated computerized tomographic angiography versus trans-thoracic echocardiography. Int J Cardiol 184:22–27CrossRef
32.
Zurück zum Zitat Mendoza DD, Kochar M, Devereux RB, Basson CT, Min JK, Holmes K et al (2011) Impact of image analysis methodology on diagnostic and surgical classification of patients with thoracic aortic aneurysms. Ann Thorac Surg 92:904–912CrossRef Mendoza DD, Kochar M, Devereux RB, Basson CT, Min JK, Holmes K et al (2011) Impact of image analysis methodology on diagnostic and surgical classification of patients with thoracic aortic aneurysms. Ann Thorac Surg 92:904–912CrossRef
33.
Zurück zum Zitat Eikendal ALM, Blomberg BA, Haaring C, Saam T, van der Geest RJ, Visser F et al (2016) 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study. J Cardiovasc Magn Reson 18(1):20CrossRef Eikendal ALM, Blomberg BA, Haaring C, Saam T, van der Geest RJ, Visser F et al (2016) 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study. J Cardiovasc Magn Reson 18(1):20CrossRef
34.
Zurück zum Zitat Liu C-Y, Chen D, Bluemke DA, Wu CO, Teixidó-Tura G, Chugh A et al (2015) Evolution of aortic wall thickness and stiffness with atherosclerosis. Hypertension 65:1015–1019CrossRef Liu C-Y, Chen D, Bluemke DA, Wu CO, Teixidó-Tura G, Chugh A et al (2015) Evolution of aortic wall thickness and stiffness with atherosclerosis. Hypertension 65:1015–1019CrossRef
Metadaten
Titel
Reliability of non-contrast magnetic resonance angiography-derived aortic diameters in Marfan patients: comparison of inner vs. outer vessel wall measurements
verfasst von
Julius Matthias Weinrich
Maxim Avanesov
Alexander Lenz
Enver Tahir
Frank-Oliver Henes
Bjoern Philip Schoennagel
Meike Rybczinsky
Gerhard Adam
Yskert von Kodolitsch
Peter Bannas
Publikationsdatum
20.04.2020
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 8/2020
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-020-01850-4

Weitere Artikel der Ausgabe 8/2020

The International Journal of Cardiovascular Imaging 8/2020 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.