Skip to main content
Erschienen in: International Ophthalmology 1/2019

11.12.2017 | Original Paper

Retrospective review on the outcome and safety of transscleral diode laser cyclophotocoagulation in refractory glaucoma in Chinese patients

verfasst von: Janice J. C. Cheung, Kenneth K. W. Li, Samuela W. K. Tang

Erschienen in: International Ophthalmology | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Transscleral cyclodiode laser cyclophotocoagulation (TSCP) is often reserved for treatment of refractory glaucoma. This retrospective study investigates the safety and efficacy of TSCP among the Chinese population.

Methods

A retrospective review was performed on electronic patient records of all patients receiving TSCP between years 2009 to year 2016. Patient demographics, indication for laser, success and response rate, change in intraocular pressure (IOP), number of treatment sessions, laser energy, glaucoma medication, visual acuity, pain symptoms and complication rate were documented.

Results

The study included 126 patients: 81 patients were male and 45 were female, and the mean age was 66.6 ± 14.3 years old and the mean follow-up was 22.7 ± 14.1 months. The mean number of treatment sessions was 1.5 ± 0.8. The success rate was 67.3%. The mean IOP before TSCP was 67 ± 38.6 mmHg and 22.8 ± 14.2 mmHg after TSCP, the mean IOP reduction was 38.4%, which was statistically significant (P value < 0.001, Wilcoxon signed rank test). The mean laser energy used per eye was 72.7 ± 56.6 and 49.2 ± 22.9 J per individual treatment session. The mean number of laser shots was 15.0 ± 6.1. 71% of patients were able to reduce their glaucoma medication after TSCP, (P value < 0.01, Wilcoxon signed rank test). 86.1% of patients had improvement in pain symptoms after TSCP. The overall complication rate was 7.1%.

Conclusion

TSCP was found to be safe and effective among the Chinese population, with comparably low laser energy setting and complication rate. It was found to be most effective in treatment of glaucoma due to trauma, acute angle closure, uveitis and chronic angle closure.
Literatur
1.
Zurück zum Zitat Kaushik S, Pandav SS, Jain R, Bansal S, Gupta A (2008) Lower energy levels adequate for effective transscleral diode laser cyclophotocoagulation in Asian eyes with refractory glaucoma. Eye (Lond) 22(3):398–405CrossRef Kaushik S, Pandav SS, Jain R, Bansal S, Gupta A (2008) Lower energy levels adequate for effective transscleral diode laser cyclophotocoagulation in Asian eyes with refractory glaucoma. Eye (Lond) 22(3):398–405CrossRef
2.
Zurück zum Zitat Frezzotti P, Mittica V, Martone G, Motolese I, Lomurno L, Peruzzi S, Motolese E (2010) Longterm follow-up of diode laser transscleral cyclophotocoagulation in the treatment of refractory glaucoma. Acta Ophthalmol 88(1):150–155CrossRefPubMed Frezzotti P, Mittica V, Martone G, Motolese I, Lomurno L, Peruzzi S, Motolese E (2010) Longterm follow-up of diode laser transscleral cyclophotocoagulation in the treatment of refractory glaucoma. Acta Ophthalmol 88(1):150–155CrossRefPubMed
3.
Zurück zum Zitat Ansari E, Gandhewar J (2006) Long-term efficacy and visual acuity following transscleral diode laser photocoagulation in cases of refractory and non-refractory glaucoma. Eye 21(7):936–940CrossRefPubMed Ansari E, Gandhewar J (2006) Long-term efficacy and visual acuity following transscleral diode laser photocoagulation in cases of refractory and non-refractory glaucoma. Eye 21(7):936–940CrossRefPubMed
4.
Zurück zum Zitat Murphy CC, Burnett CA, Spry PG, Broadway DC, Diamond JP (2003) A two centre study of the dose-response relation for transscleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 87(10):1252–1257CrossRefPubMedPubMedCentral Murphy CC, Burnett CA, Spry PG, Broadway DC, Diamond JP (2003) A two centre study of the dose-response relation for transscleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 87(10):1252–1257CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Pucci V, Tappainer F, Borin S, Bellucci R (2003) Long-term follow-up after transscleral diode laser photocoagulation in refractory glaucoma. Ophthalmologica 217(4):279–283CrossRefPubMed Pucci V, Tappainer F, Borin S, Bellucci R (2003) Long-term follow-up after transscleral diode laser photocoagulation in refractory glaucoma. Ophthalmologica 217(4):279–283CrossRefPubMed
6.
Zurück zum Zitat Iliev ME, Gerber S (2007) Long-term outcome of trans-scleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 91(12):1631–1635CrossRefPubMedPubMedCentral Iliev ME, Gerber S (2007) Long-term outcome of trans-scleral diode laser cyclophotocoagulation in refractory glaucoma. Br J Ophthalmol 91(12):1631–1635CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Kirwan JF, Shah P, Khaw PT (2002) Diode laser cyclophotocoagulation: role in the management of refractory pediatric glaucomas. Ophthalmology 109(2):316–323CrossRefPubMed Kirwan JF, Shah P, Khaw PT (2002) Diode laser cyclophotocoagulation: role in the management of refractory pediatric glaucomas. Ophthalmology 109(2):316–323CrossRefPubMed
8.
Zurück zum Zitat Rotchford AP, Jayasawal R, Madhusudhan S, Ho S, King AJ, Vernon SA (2010) Transscleral diode laser cycloablation in patients with good vision. Br J Ophthalmol 94(9):1180–1183CrossRefPubMed Rotchford AP, Jayasawal R, Madhusudhan S, Ho S, King AJ, Vernon SA (2010) Transscleral diode laser cycloablation in patients with good vision. Br J Ophthalmol 94(9):1180–1183CrossRefPubMed
9.
Zurück zum Zitat Cantor LB, Nichols DA, Katz LJ, Moster MR, Poryzees E, Shields JA, Spaeth GL (1989) Neodymium-YAG transscleral cyclophotocoagulation. The role of pigmentation. Invest Ophthalmol Vis Sci 30(8):1834–1837PubMed Cantor LB, Nichols DA, Katz LJ, Moster MR, Poryzees E, Shields JA, Spaeth GL (1989) Neodymium-YAG transscleral cyclophotocoagulation. The role of pigmentation. Invest Ophthalmol Vis Sci 30(8):1834–1837PubMed
10.
Zurück zum Zitat Fankhauser F, van der Zypen E, Kwasniewska S, Rol P, England C (1986) Transscleral cyclophotocoagulation using a neodymium YAG laser. Ophthalmic Surg 17(2):94–100PubMed Fankhauser F, van der Zypen E, Kwasniewska S, Rol P, England C (1986) Transscleral cyclophotocoagulation using a neodymium YAG laser. Ophthalmic Surg 17(2):94–100PubMed
11.
Zurück zum Zitat Hawkins TA, Stewart WC (1993) One-year results of semiconductor transscleral cyclophotocoagulation in patients with glaucoma. Arch Ophthalmol 111(4):488–491CrossRefPubMed Hawkins TA, Stewart WC (1993) One-year results of semiconductor transscleral cyclophotocoagulation in patients with glaucoma. Arch Ophthalmol 111(4):488–491CrossRefPubMed
12.
Zurück zum Zitat Wong EY, Chew PT, Chee CK, Wong JS (1997) Diode laser contact transscleral cyclophotocoagulation for refractory glaucoma in Asian patients. Am J Ophthalmol 124(6):797–804CrossRefPubMed Wong EY, Chew PT, Chee CK, Wong JS (1997) Diode laser contact transscleral cyclophotocoagulation for refractory glaucoma in Asian patients. Am J Ophthalmol 124(6):797–804CrossRefPubMed
13.
Zurück zum Zitat Schlote T, Derse M, Rassmann K, Nicaeus T, Dietz K, Thiel HJ (2001) Efficacy and safety of contact transscleral diode laser cyclophotocoagulation for advanced glaucoma. J Glaucoma 10(4):294–301CrossRefPubMed Schlote T, Derse M, Rassmann K, Nicaeus T, Dietz K, Thiel HJ (2001) Efficacy and safety of contact transscleral diode laser cyclophotocoagulation for advanced glaucoma. J Glaucoma 10(4):294–301CrossRefPubMed
14.
Zurück zum Zitat Sivagnanavel V, Ortiz-Hurtado A, Williamson TH (2004) Diode laser trans-scleral cyclophotocoagulation in the management of glaucoma in patients with long-term intravitreal silicone oil. Eye 19(3):253–257CrossRef Sivagnanavel V, Ortiz-Hurtado A, Williamson TH (2004) Diode laser trans-scleral cyclophotocoagulation in the management of glaucoma in patients with long-term intravitreal silicone oil. Eye 19(3):253–257CrossRef
15.
Zurück zum Zitat Kumar A, Dada T, Singh RP, Kedar S (2001) Diode laser trans-scleral cyclophotocoagulation for glaucoma following silicone oil removal. Clin Exp Ophthalmol 29(4):220–224CrossRefPubMed Kumar A, Dada T, Singh RP, Kedar S (2001) Diode laser trans-scleral cyclophotocoagulation for glaucoma following silicone oil removal. Clin Exp Ophthalmol 29(4):220–224CrossRefPubMed
16.
Zurück zum Zitat Riedel KG, Gabel V-P, Neubauer L, Kampik A, Lund O-E (1990) Intravitreal silicone oil injection: complications and treatment of 415 consecutive patients. Graefes Arch Clin Exp Ophthalmol 228(1):19–23CrossRefPubMed Riedel KG, Gabel V-P, Neubauer L, Kampik A, Lund O-E (1990) Intravitreal silicone oil injection: complications and treatment of 415 consecutive patients. Graefes Arch Clin Exp Ophthalmol 228(1):19–23CrossRefPubMed
Metadaten
Titel
Retrospective review on the outcome and safety of transscleral diode laser cyclophotocoagulation in refractory glaucoma in Chinese patients
verfasst von
Janice J. C. Cheung
Kenneth K. W. Li
Samuela W. K. Tang
Publikationsdatum
11.12.2017
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 1/2019
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0782-1

Weitere Artikel der Ausgabe 1/2019

International Ophthalmology 1/2019 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.