Skip to main content
Erschienen in: Archives of Gynecology and Obstetrics 6/2019

29.03.2019 | Gynecologic Oncology

Risk factors for failure of sentinel lymph node mapping using indocyanine green/near-infrared fluorescent imaging in endometrial cancer

verfasst von: Salih Taşkın, Mustafa Erkan Sarı, Duygu Altın, Cevriye Cansız Ersöz, Ali Gökçe, Seher Yüksel, Duygu Kankaya, Fırat Ortaç

Erschienen in: Archives of Gynecology and Obstetrics | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Side-specific systematic lymphadenectomy is suggested if sentinel lymph node (SLN) mapping failed in early stages endometrial cancer. This study aimed to evaluate the risk factors associated with failed mapping which may lead to modify SLN mapping technique, increase the success of SLN mapping and reduce the necessity of systematic lymphadenectomy.

Methods

Patients with early stage endometrial cancer were included in this study. All patients underwent SLN mapping with indocyanine green/near-infrared compatible surgical platforms. Indocyanine green was injected intracervical. “Bilateral mapping” and “failed bilateral SLN mapping (unilateral or bilateral failed mapping)” groups were compared for demographic, clinical, surgical, and pathological features.

Results

101 cases were analyzed. The overall, unilateral, and bilateral SLN detection rates were 94.1%, 19.8%, and 74.3%, respectively. The failed (unilateral or no mapping) bilateral detection rate was 25.7%. Failed bilateral mapping rates were higher in patients with longer cervical and uterine longitudinal lengths, deep myometrial invasion and larger tumor size without statistical significance. Body mass index and operation type were not related with failed mapping. Increasing number of operations or injection of larger volume of indocyanine green (4 mL vs. 2 mL) did not improve mapping rate significantly.

Conclusion

Cervical indocyanine green injection may overcome the negative effect of obesity on bilateral mapping. Although there was a negative correlation trend between the longitudinal cervical and uterine lengths and bilateral mapping, this possible relation needs to be confirmed in further studies.
Literatur
1.
Zurück zum Zitat Barlin JN, Khoury-Collado F, Kim CH et al (2012) The importance of applying a sentinel lymph node mapping algorithm in endometrial cancer staging: beyond removal of blue nodes. Gynecol Oncol 125:531–535CrossRefPubMed Barlin JN, Khoury-Collado F, Kim CH et al (2012) The importance of applying a sentinel lymph node mapping algorithm in endometrial cancer staging: beyond removal of blue nodes. Gynecol Oncol 125:531–535CrossRefPubMed
2.
Zurück zum Zitat Kuru O, Topuz S, Sen S et al (2011) Sentinel lymph node biopsy in endometrial cancer: description of the technique and preliminary results. J Turk Ger Gynecol Assoc 12:204–208CrossRefPubMedPubMedCentral Kuru O, Topuz S, Sen S et al (2011) Sentinel lymph node biopsy in endometrial cancer: description of the technique and preliminary results. J Turk Ger Gynecol Assoc 12:204–208CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Papadia A, Imboden S, Siegenthaler F et al (2016) Laparoscopic indocyanine green sentinel lymph node mapping in endometrial cancer. Ann Surg Oncol 23:2206–2211CrossRefPubMedPubMedCentral Papadia A, Imboden S, Siegenthaler F et al (2016) Laparoscopic indocyanine green sentinel lymph node mapping in endometrial cancer. Ann Surg Oncol 23:2206–2211CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Buda A, Bussi B, Di Martino G et al (2016) Sentinel lymph node mapping with near-infrared fluorescent imaging using indocyanine green: a new tool for laparoscopic platform in patients with endometrial and cervical cancer. J Minim Invasive Gynecol 23:265–269CrossRefPubMed Buda A, Bussi B, Di Martino G et al (2016) Sentinel lymph node mapping with near-infrared fluorescent imaging using indocyanine green: a new tool for laparoscopic platform in patients with endometrial and cervical cancer. J Minim Invasive Gynecol 23:265–269CrossRefPubMed
5.
Zurück zum Zitat Plante M, Touhami O, Trinh XB et al (2015) Sentinel node mapping with indocyanine green and endoscopic near-infrared fluorescence imaging in endometrial cancer. a pilot study and review of the literature. Gynecol Oncol 137:443–447CrossRefPubMed Plante M, Touhami O, Trinh XB et al (2015) Sentinel node mapping with indocyanine green and endoscopic near-infrared fluorescence imaging in endometrial cancer. a pilot study and review of the literature. Gynecol Oncol 137:443–447CrossRefPubMed
6.
Zurück zum Zitat Bodurtha Smith AJ, Fader AN, Tanner EJ (2017) Sentinel lymph node assessment in endometrial cancer: a systematic review and meta-analysis. Am J Obstet Gynecol 216:459.e10–476.e10CrossRef Bodurtha Smith AJ, Fader AN, Tanner EJ (2017) Sentinel lymph node assessment in endometrial cancer: a systematic review and meta-analysis. Am J Obstet Gynecol 216:459.e10–476.e10CrossRef
7.
Zurück zum Zitat Darin MC, Gómez-Hidalgo NR, Westin SN et al (2016) Role of indocyanine green in sentinel node mapping in gynecologic cancer: is fluorescence imaging the new standard? J Min Invasive Gynecol 23:186–193CrossRef Darin MC, Gómez-Hidalgo NR, Westin SN et al (2016) Role of indocyanine green in sentinel node mapping in gynecologic cancer: is fluorescence imaging the new standard? J Min Invasive Gynecol 23:186–193CrossRef
8.
Zurück zum Zitat Tanner EJ, Sinno AK, Stone RL et al (2015) Factors associated with successful bilateral sentinel lymph node mapping in endometrial cancer. Gynecol Oncol 138:542–547CrossRefPubMed Tanner EJ, Sinno AK, Stone RL et al (2015) Factors associated with successful bilateral sentinel lymph node mapping in endometrial cancer. Gynecol Oncol 138:542–547CrossRefPubMed
9.
Zurück zum Zitat How JA, O’Farrell P, Amajoud Z et al (2018) Sentinel lymph node mapping in endometrial cancer: a systematic review and meta-analysis. Miner Ginecol 70:194–214 How JA, O’Farrell P, Amajoud Z et al (2018) Sentinel lymph node mapping in endometrial cancer: a systematic review and meta-analysis. Miner Ginecol 70:194–214
10.
Zurück zum Zitat Taskin S, Sukur YE, Altin D et al (2017) Laparoscopic near-infrared fluorescent imaging as an alternative option for sentinel lymph node mapping in endometrial cancer: a prospective study. Int J Surg 47:13–17CrossRefPubMed Taskin S, Sukur YE, Altin D et al (2017) Laparoscopic near-infrared fluorescent imaging as an alternative option for sentinel lymph node mapping in endometrial cancer: a prospective study. Int J Surg 47:13–17CrossRefPubMed
11.
Zurück zum Zitat Rossi EC, Kowalski LD, Scalici J et al (2017) Comparison of sentinel lymph node biopsy to lymphadenectomy for endometrial cancer staging (FIRES trial): a multicentre, prospective, cohort study. Lancet Oncol 18:384–392CrossRefPubMed Rossi EC, Kowalski LD, Scalici J et al (2017) Comparison of sentinel lymph node biopsy to lymphadenectomy for endometrial cancer staging (FIRES trial): a multicentre, prospective, cohort study. Lancet Oncol 18:384–392CrossRefPubMed
12.
Zurück zum Zitat Hagen B, Valla M, Aune G et al (2016) Indocyanine green fluorescence imaging of lymph nodes during robotic-assisted laparoscopic operation for endometrial cancer. a prospective validation study using a sentinel lymph node surgical algorithm. Gynecol Oncol 143:479–483CrossRefPubMed Hagen B, Valla M, Aune G et al (2016) Indocyanine green fluorescence imaging of lymph nodes during robotic-assisted laparoscopic operation for endometrial cancer. a prospective validation study using a sentinel lymph node surgical algorithm. Gynecol Oncol 143:479–483CrossRefPubMed
13.
Zurück zum Zitat Papadia A, Zapardiel I, Bussi B et al (2017) Sentinel lymph node mapping in patients with stage I endometrial carcinoma: a focus on bilateral mapping identification by comparing radiotracer Tc99m with blue dye versus indocyanin green fluorescent dye. J Cancer Res Clin Oncol 143:475–480CrossRefPubMed Papadia A, Zapardiel I, Bussi B et al (2017) Sentinel lymph node mapping in patients with stage I endometrial carcinoma: a focus on bilateral mapping identification by comparing radiotracer Tc99m with blue dye versus indocyanin green fluorescent dye. J Cancer Res Clin Oncol 143:475–480CrossRefPubMed
14.
Zurück zum Zitat Xiong L, Gazyakan E, Yang W et al (2014) Indocyanine green fluorescence-guided sentinel node biopsy: a meta-analysis on detection rate and diagnostic performance. Eur J Surg Oncol 40:843–849CrossRefPubMed Xiong L, Gazyakan E, Yang W et al (2014) Indocyanine green fluorescence-guided sentinel node biopsy: a meta-analysis on detection rate and diagnostic performance. Eur J Surg Oncol 40:843–849CrossRefPubMed
15.
Zurück zum Zitat Papadia A, Buda A, Gasparri ML et al (2018) The impact of different doses of indocyanine green on the sentinel lymph-node mapping in early stage endometrial cancer. J Cancer Res Clin Oncol 144:2187–2191CrossRefPubMed Papadia A, Buda A, Gasparri ML et al (2018) The impact of different doses of indocyanine green on the sentinel lymph-node mapping in early stage endometrial cancer. J Cancer Res Clin Oncol 144:2187–2191CrossRefPubMed
16.
Zurück zum Zitat Salvo G, Ramirez PT, Levenback CF et al (2017) Sensitivity and negative predictive value for sentinel lymph node biopsy in women with early-stage cervical cancer. Gynecol Oncol 145:96–101CrossRefPubMedPubMedCentral Salvo G, Ramirez PT, Levenback CF et al (2017) Sensitivity and negative predictive value for sentinel lymph node biopsy in women with early-stage cervical cancer. Gynecol Oncol 145:96–101CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Body N, Grégoire J, Renaud MC et al (2018) Tips and tricks to improve sentinel lymph node mapping with Indocyanin green in endometrial cancer. Gynecol Oncol 150:267–273CrossRefPubMed Body N, Grégoire J, Renaud MC et al (2018) Tips and tricks to improve sentinel lymph node mapping with Indocyanin green in endometrial cancer. Gynecol Oncol 150:267–273CrossRefPubMed
18.
Zurück zum Zitat Casarin J, Multinu F, Pasupathy K et al (2018) Frozen section for detection of lymph nodes after cervical injection with indocyanine green (ICG) for sentinel lymph node technique in endometrial cancer staging. Ann Surg Oncol 25:3692–3698CrossRefPubMed Casarin J, Multinu F, Pasupathy K et al (2018) Frozen section for detection of lymph nodes after cervical injection with indocyanine green (ICG) for sentinel lymph node technique in endometrial cancer staging. Ann Surg Oncol 25:3692–3698CrossRefPubMed
19.
Zurück zum Zitat Persson J, Geppert B, Lönnerfors C et al (2017) Description of reproducible anatomically based surgical algorithm for detection of pelvic sentinel lymph nodes in endometrial cancer. Gynecol Oncol 147:120–125CrossRefPubMed Persson J, Geppert B, Lönnerfors C et al (2017) Description of reproducible anatomically based surgical algorithm for detection of pelvic sentinel lymph nodes in endometrial cancer. Gynecol Oncol 147:120–125CrossRefPubMed
Metadaten
Titel
Risk factors for failure of sentinel lymph node mapping using indocyanine green/near-infrared fluorescent imaging in endometrial cancer
verfasst von
Salih Taşkın
Mustafa Erkan Sarı
Duygu Altın
Cevriye Cansız Ersöz
Ali Gökçe
Seher Yüksel
Duygu Kankaya
Fırat Ortaç
Publikationsdatum
29.03.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Gynecology and Obstetrics / Ausgabe 6/2019
Print ISSN: 0932-0067
Elektronische ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-019-05137-5

Weitere Artikel der Ausgabe 6/2019

Archives of Gynecology and Obstetrics 6/2019 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.