Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 1/2023

01.08.2022 | Original Article

Risk factors for hardware-related complications after extra-articular distal humerus fracture fixation using an anatomical locking plate

verfasst von: Hyoung-Seok Jung, Yoo-Sun Won, Yang-Seon Choi, Jae-Sung Lee

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 1/2023

Einloggen, um Zugang zu erhalten

Abstract

Purpose

We aimed to identify the incidence and risk factors of hardware-related complications in patients treated with anatomical locking plate fixation for extra-articular distal humerus fractures.

Methods

From 2013 to 2020, patients with extra-articular distal humerus fractures who underwent open reduction and internal fixation with an extra-articular distal humerus locking plate (EADHP) were retrospectively reviewed and categorized according to the presence/absence of hardware-related complications. Hardware-related complications were defined as the occurrence of skin prominence on the plate and discomfort in activities of daily living. Patient demographics, the lateral condylar angle, lateral body length, shaft-condylar angle of the humerus, and plate length were analyzed.

Results

Of the 29 patients, 10 (34%) did not develop hardware-related complications (group A), whereas 19 (66%) did (group B). Patient demographics did not differ between the groups. However, the number of patients who underwent hardware removal was significantly greater in group B (16/19) than in group A (4/10; p = 0.032). Radiologic assessment revealed no significant difference in the lateral condylar or shaft-condylar angle. However, the lateral body length was greater in group A than in group B (44.5 ± 4.8 vs. 39.5 ± 3.7, p = 0.007). The plate length significantly differed between the groups. Twelve of 19 (63%) patients in group B received short-hole plates (six holes), while nine of ten (90%) patients in group A received long-hole plates (eight holes). In the multivariable analysis, the lateral body length of the distal humerus (p = 0.047, odds ratio = 0.734, 95% confidence interval: 0.542–0.996) and plate length (p = 0.036, odds ratio = 0.076, 95% confidence interval: 0.542–0.996) were associated with hardware-related complications.

Conclusions

Most patients developed hardware-related complications, particularly with short plates, mainly because of the narrow lateral body length of the distal humerus. Surgeons should be careful to secure EADHP in the appropriate position, especially when short plates are used in patients with narrow lateral body length.
Literatur
1.
Zurück zum Zitat Ekholm R, Adami J, Tidermark J, Hansson K, Törnkvist H, Ponzer S. Fractures of the shaft of the humerus an epidemiological study of 401 fractures. J Bone Joint Surg Br. 2006;88(11):1469–73.CrossRefPubMed Ekholm R, Adami J, Tidermark J, Hansson K, Törnkvist H, Ponzer S. Fractures of the shaft of the humerus an epidemiological study of 401 fractures. J Bone Joint Surg Br. 2006;88(11):1469–73.CrossRefPubMed
23.
Zurück zum Zitat Ali N, Ahmad Mir N, Ahmad Dar T, Nawaz Rather M, Ahmad Mir W, S S, et al. Outcome of extra-articular distal humerus fractures fixed by single column extra-articular distal humerus locking compression plate using triceps sparing postero-lateral approach. Bull Emerg Trauma. 2018;6(4):306–12.CrossRefPubMedPubMedCentral Ali N, Ahmad Mir N, Ahmad Dar T, Nawaz Rather M, Ahmad Mir W, S S, et al. Outcome of extra-articular distal humerus fractures fixed by single column extra-articular distal humerus locking compression plate using triceps sparing postero-lateral approach. Bull Emerg Trauma. 2018;6(4):306–12.CrossRefPubMedPubMedCentral
Metadaten
Titel
Risk factors for hardware-related complications after extra-articular distal humerus fracture fixation using an anatomical locking plate
verfasst von
Hyoung-Seok Jung
Yoo-Sun Won
Yang-Seon Choi
Jae-Sung Lee
Publikationsdatum
01.08.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 1/2023
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-022-02064-0

Weitere Artikel der Ausgabe 1/2023

European Journal of Trauma and Emergency Surgery 1/2023 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.