Skip to main content
Erschienen in: Abdominal Radiology 2/2019

24.08.2018 | Invited article

Role of dual energy CT to improve diagnosis of non-traumatic abdominal vascular emergencies

verfasst von: Khalid W. Shaqdan, Anushri Parakh, Avinash R. Kambadakone, Dushyant V. Sahani

Erschienen in: Abdominal Radiology | Ausgabe 2/2019

Einloggen, um Zugang zu erhalten

Abstract

Computed tomography angiography (CTA) is the modality of choice to evaluate abdominal vascular emergencies (AVE). CTA protocols are often complex and require acquisition of multiple phases to enable a variety of diagnosis such as acute bleeding, pseudoaneurysms, bowel ischemia, and dissection. With single energy CT (SECT), differentiating between calcium, coagulated blood, and contrast agents can be challenging based on their attenuation, especially when in small quantity or present as a mixture. With dual-energy CT (DECT), virtual monoenergetic (VM) and material decomposition (MD) image reconstructions enable more robust tissue characterization, improve contrast-enhancement, and reduce beam hardening artifacts. This article will demonstrate how radiologists can utilize DECT for various clinical scenarios in assessment of non-traumatic AVE.
Literatur
2.
Zurück zum Zitat Hansen NJ (2016) Computed tomographic angiography of the abdominal aorta. Radiol Clin N Am 54(1):35–54PubMedCrossRef Hansen NJ (2016) Computed tomographic angiography of the abdominal aorta. Radiol Clin N Am 54(1):35–54PubMedCrossRef
3.
Zurück zum Zitat Fuentes-Orrego JM, Pinho D, Kulkarni NM, et al. (2014) New and evolving concepts in CT for abdominal vascular imaging. RadioGraphics 34(5):1363–1384PubMedCrossRef Fuentes-Orrego JM, Pinho D, Kulkarni NM, et al. (2014) New and evolving concepts in CT for abdominal vascular imaging. RadioGraphics 34(5):1363–1384PubMedCrossRef
4.
Zurück zum Zitat Kondo H, Kanematsu M, Goshima S, et al. (2010) Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume. Radiology 254(1):1639CrossRef Kondo H, Kanematsu M, Goshima S, et al. (2010) Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume. Radiology 254(1):1639CrossRef
5.
Zurück zum Zitat Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679–1691PubMedCrossRef Barrett JF, Keat N (2004) Artifacts in CT: recognition and avoidance. Radiographics 24:1679–1691PubMedCrossRef
6.
Zurück zum Zitat Schindera ST, Tock I, Marin D, et al. (2010) Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: an in vitro and in vivo study. Radiology 256:528–535PubMedCrossRef Schindera ST, Tock I, Marin D, et al. (2010) Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: an in vitro and in vivo study. Radiology 256:528–535PubMedCrossRef
7.
Zurück zum Zitat Campbell SG, Croskerry P, Bond WF (2007) Profiles in patient safety: a “perfect storm” in the emergency department. Acad Emerg Med 14:743–749PubMed Campbell SG, Croskerry P, Bond WF (2007) Profiles in patient safety: a “perfect storm” in the emergency department. Acad Emerg Med 14:743–749PubMed
9.
Zurück zum Zitat Marin D, Boll DT, Mileto A, Nelson RC (2014) State of the art: dual-energy CT of the abdomen. Radiology 271(2):327–342PubMedCrossRef Marin D, Boll DT, Mileto A, Nelson RC (2014) State of the art: dual-energy CT of the abdomen. Radiology 271(2):327–342PubMedCrossRef
10.
Zurück zum Zitat Megibow AJ, Sahani D (2012) Best practice: implementation and use of abdominal dual-energy CT in routine patient care. AJR Am J Roentgenol 199(5 Suppl):S71–S77PubMedCrossRef Megibow AJ, Sahani D (2012) Best practice: implementation and use of abdominal dual-energy CT in routine patient care. AJR Am J Roentgenol 199(5 Suppl):S71–S77PubMedCrossRef
11.
Zurück zum Zitat Grajo JR, Patino M, Prochowski A, Sahani DV (2016) Dual energy CT in practice: basic principles and applications. Appl Radiol 45:6–12 Grajo JR, Patino M, Prochowski A, Sahani DV (2016) Dual energy CT in practice: basic principles and applications. Appl Radiol 45:6–12
12.
Zurück zum Zitat McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multienergy CT: principles, technical approaches, and clinical applications. Radiology 276(3):637–653PubMedPubMedCentralCrossRef McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multienergy CT: principles, technical approaches, and clinical applications. Radiology 276(3):637–653PubMedPubMedCentralCrossRef
13.
Zurück zum Zitat Shuman WP, O’Malley RB, Busey JM, Ramos MM, Koprowicz KM (2017) Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient. Abdom Radiol (NY) 42(3):759–765CrossRef Shuman WP, O’Malley RB, Busey JM, Ramos MM, Koprowicz KM (2017) Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient. Abdom Radiol (NY) 42(3):759–765CrossRef
14.
Zurück zum Zitat Kaza RK, Ananthakrishnan L, Kambadakone A, Platt JF (2017) Update of dual-energy CT applications in the genitourinary tract. AJR Am J Roentgenol 208(6):1185–1192PubMedCrossRef Kaza RK, Ananthakrishnan L, Kambadakone A, Platt JF (2017) Update of dual-energy CT applications in the genitourinary tract. AJR Am J Roentgenol 208(6):1185–1192PubMedCrossRef
16.
Zurück zum Zitat Kalisz K, Halliburton S, Abbara S, et al. (2017) Update on cardiovascular applications of multienergy CT. Radiographics 37(7):1955–1974PubMedCrossRef Kalisz K, Halliburton S, Abbara S, et al. (2017) Update on cardiovascular applications of multienergy CT. Radiographics 37(7):1955–1974PubMedCrossRef
18.
Zurück zum Zitat Almeida IP, Schyns LE, Öllers MC, et al. (2017) Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners. Med Phys 44(1):171–179PubMedCrossRef Almeida IP, Schyns LE, Öllers MC, et al. (2017) Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners. Med Phys 44(1):171–179PubMedCrossRef
19.
Zurück zum Zitat Wang L, Liu B, Wu XW, et al. (2012) Correlation between CT attenuation value and iodine concentration in vitro: discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging. J Med Imaging Radiat Oncol 56:379–383PubMedCrossRef Wang L, Liu B, Wu XW, et al. (2012) Correlation between CT attenuation value and iodine concentration in vitro: discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging. J Med Imaging Radiat Oncol 56:379–383PubMedCrossRef
20.
Zurück zum Zitat Matsuda I, Akahane M, Sato J, et al. (2012) Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms. Jpn J Radiol 30:34–39PubMedCrossRef Matsuda I, Akahane M, Sato J, et al. (2012) Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms. Jpn J Radiol 30:34–39PubMedCrossRef
21.
Zurück zum Zitat Coursey CA, Nelson RC, Boll DT, et al. (2010) Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics 30(4):1037–1055PubMedCrossRef Coursey CA, Nelson RC, Boll DT, et al. (2010) Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics 30(4):1037–1055PubMedCrossRef
22.
Zurück zum Zitat Patino M, Prochowski A, Agrawal MD, et al. (2016) Material separation using dual-energy CT: current and emerging applications. Radiographics 33(4):1087–1105CrossRef Patino M, Prochowski A, Agrawal MD, et al. (2016) Material separation using dual-energy CT: current and emerging applications. Radiographics 33(4):1087–1105CrossRef
23.
Zurück zum Zitat Sellerer T, Noël PB, Patino M, et al. (2018) Dual-energy CT: a phantom comparison of different platforms for abdominal imaging. Eur Radiol 7:2745–2755CrossRef Sellerer T, Noël PB, Patino M, et al. (2018) Dual-energy CT: a phantom comparison of different platforms for abdominal imaging. Eur Radiol 7:2745–2755CrossRef
24.
Zurück zum Zitat Im AL, Lee YH, Bang DH, Yoon KH, Park SH (2013) Dual energy CT in patients with acute abdomen; is it possible for virtual non-enhanced images to replace true non-enhanced images? Emerg Radiol 20:475–483PubMedCrossRef Im AL, Lee YH, Bang DH, Yoon KH, Park SH (2013) Dual energy CT in patients with acute abdomen; is it possible for virtual non-enhanced images to replace true non-enhanced images? Emerg Radiol 20:475–483PubMedCrossRef
25.
Zurück zum Zitat Borhani AA, Kulzer M, Iranpour N, et al. (2017) Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT. Abdom Radiol 42:710–717CrossRef Borhani AA, Kulzer M, Iranpour N, et al. (2017) Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT. Abdom Radiol 42:710–717CrossRef
26.
Zurück zum Zitat Zhao YE, Wang ZJ, Zhou CS (2014) Multidetector computed tomography of superior mesenteric artery: anatomy and pathologies. Can Assoc Radiol J. 65:267–274PubMedCrossRef Zhao YE, Wang ZJ, Zhou CS (2014) Multidetector computed tomography of superior mesenteric artery: anatomy and pathologies. Can Assoc Radiol J. 65:267–274PubMedCrossRef
27.
Zurück zum Zitat Cordeiro MA, Lima JA (2006) Atherosclerotic plaque characterization by multidetector row computed tomography angiography. J Am Coll Cardiol 47(8 Suppl):C40–C47PubMedCrossRef Cordeiro MA, Lima JA (2006) Atherosclerotic plaque characterization by multidetector row computed tomography angiography. J Am Coll Cardiol 47(8 Suppl):C40–C47PubMedCrossRef
29.
Zurück zum Zitat Ascenti G, Sofia C, Mazziotti S, et al. (2016) Dual-energy CT with iodine quantification in distinguishing between bland and neoplastic portal vein thrombosis in patients with hepatocellular carcinoma. Clin Radiol. 71(9):938.e1–938.e9CrossRef Ascenti G, Sofia C, Mazziotti S, et al. (2016) Dual-energy CT with iodine quantification in distinguishing between bland and neoplastic portal vein thrombosis in patients with hepatocellular carcinoma. Clin Radiol. 71(9):938.e1–938.e9CrossRef
30.
Zurück zum Zitat Howard DP, Sideso E, Handa A, et al. (2014) Incidence, risk factors, outcome and projected future burden of acute aortic dissection. Ann Cardiothorac Sur. 3:278–284 Howard DP, Sideso E, Handa A, et al. (2014) Incidence, risk factors, outcome and projected future burden of acute aortic dissection. Ann Cardiothorac Sur. 3:278–284
31.
Zurück zum Zitat Pinho DF, Kulkarni NM, Krishnaraj A, Kalva SP, Sahani DV (2013) Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose. Eur Radiol 23(2):351–359PubMedCrossRef Pinho DF, Kulkarni NM, Krishnaraj A, Kalva SP, Sahani DV (2013) Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose. Eur Radiol 23(2):351–359PubMedCrossRef
32.
33.
Zurück zum Zitat Jesinger RA, Thoreson AA, Lamba R (2013) Abdominal and pelvic aneurysms and pseudoaneurysms: imaging review with clinical, radiologic, and treatment correlation. Radiographics 33:E71–E96PubMedCrossRef Jesinger RA, Thoreson AA, Lamba R (2013) Abdominal and pelvic aneurysms and pseudoaneurysms: imaging review with clinical, radiologic, and treatment correlation. Radiographics 33:E71–E96PubMedCrossRef
34.
Zurück zum Zitat Wortman JR, Uyeda JW, Fulwadhva UP, Sodickson AD (2018) Dual-energy CT for abdominal and pelvic trauma. Radiographic 38(2):586–602CrossRef Wortman JR, Uyeda JW, Fulwadhva UP, Sodickson AD (2018) Dual-energy CT for abdominal and pelvic trauma. Radiographic 38(2):586–602CrossRef
35.
Zurück zum Zitat Machida H, Tanaka I, Fukui R, et al. (2016) Dual-energy spectral CT: various clinical vascular applications. Radiographics 36(4):1215–1232PubMedCrossRef Machida H, Tanaka I, Fukui R, et al. (2016) Dual-energy spectral CT: various clinical vascular applications. Radiographics 36(4):1215–1232PubMedCrossRef
36.
Zurück zum Zitat Maturen KE, Kaza RK, Liu PS, et al. (2012) “Sweet spot” for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT. J Comput Assist Tomogr 36:83–87PubMedPubMedCentralCrossRef Maturen KE, Kaza RK, Liu PS, et al. (2012) “Sweet spot” for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT. J Comput Assist Tomogr 36:83–87PubMedPubMedCentralCrossRef
37.
Zurück zum Zitat Martin SS, Wichmann JL, Scholtz JE, et al. (2017) Noise-optimized virtual monoenergetic dual-energy CT improves diagnostic accuracy for the detection of active arterial bleeding of the abdomen. J Vasc Interv Radiol 28(9):1257–1266PubMedCrossRef Martin SS, Wichmann JL, Scholtz JE, et al. (2017) Noise-optimized virtual monoenergetic dual-energy CT improves diagnostic accuracy for the detection of active arterial bleeding of the abdomen. J Vasc Interv Radiol 28(9):1257–1266PubMedCrossRef
38.
Zurück zum Zitat Chandarana H, Godoy MC, Vlahos I, et al. (2008) Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms—initial observations. Radiology 249:692–700PubMedCrossRef Chandarana H, Godoy MC, Vlahos I, et al. (2008) Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms—initial observations. Radiology 249:692–700PubMedCrossRef
39.
Zurück zum Zitat Buffa V, Solazzo A, D’Auria V, et al. (2014) Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair. Radiol Med 119(12):934–941PubMedCrossRef Buffa V, Solazzo A, D’Auria V, et al. (2014) Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair. Radiol Med 119(12):934–941PubMedCrossRef
40.
Zurück zum Zitat Flors L, Leiva-Salinas C, Norton PT, Patrie JT, Hagspiel KD (2013) Endoleak detection after endovascular repair of thoracic aortic aneurysm using dual-source dual-energy CT: suitable scanning protocols and potential radiation dose reduction. AJR Am J Roentgenol 200(2):451–460PubMedCrossRef Flors L, Leiva-Salinas C, Norton PT, Patrie JT, Hagspiel KD (2013) Endoleak detection after endovascular repair of thoracic aortic aneurysm using dual-source dual-energy CT: suitable scanning protocols and potential radiation dose reduction. AJR Am J Roentgenol 200(2):451–460PubMedCrossRef
41.
Zurück zum Zitat Stolzmann P, Frauenfelder T, Pfammatter T, et al. (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691PubMedCrossRef Stolzmann P, Frauenfelder T, Pfammatter T, et al. (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691PubMedCrossRef
42.
43.
Zurück zum Zitat Dalle I, Geboes K (2002) Vascular lesions of the gastrointestinal tract. Acta Gastroenterol Belg 65(4):213–219PubMed Dalle I, Geboes K (2002) Vascular lesions of the gastrointestinal tract. Acta Gastroenterol Belg 65(4):213–219PubMed
44.
Zurück zum Zitat Makhoul F, Kaur P, Johnston TD, et al. (2008) Arteriovenous malformation of the pancreas: a case report and review of literature. Int J Angiol 17(4):211–213PubMedPubMedCentralCrossRef Makhoul F, Kaur P, Johnston TD, et al. (2008) Arteriovenous malformation of the pancreas: a case report and review of literature. Int J Angiol 17(4):211–213PubMedPubMedCentralCrossRef
45.
Zurück zum Zitat Guo Y, Ou SX, Qian M, Zeng X, Li B (2015) Dual-energy CT angiography for the diagnosis of intracranial dural arteriovenous fistula. Int J Clin Exp Med 8(5):7802–7808PubMedPubMedCentral Guo Y, Ou SX, Qian M, Zeng X, Li B (2015) Dual-energy CT angiography for the diagnosis of intracranial dural arteriovenous fistula. Int J Clin Exp Med 8(5):7802–7808PubMedPubMedCentral
46.
Zurück zum Zitat Postma AA, Hofman PA, Stadler AA, et al. (2012) Dual-energy CT of the brain and intracranial vessels. AJR Am J Roentgenol 199:S26–S33PubMedCrossRef Postma AA, Hofman PA, Stadler AA, et al. (2012) Dual-energy CT of the brain and intracranial vessels. AJR Am J Roentgenol 199:S26–S33PubMedCrossRef
47.
Zurück zum Zitat Otrakji A, Digumarthy SR, Gullo RL, et al. (2016) Dual-energy CT: spectrum of thoracic abnormalities. Radiographics 36(1):38–52PubMedCrossRef Otrakji A, Digumarthy SR, Gullo RL, et al. (2016) Dual-energy CT: spectrum of thoracic abnormalities. Radiographics 36(1):38–52PubMedCrossRef
48.
Zurück zum Zitat Geffroy Y, Rodallec MH, Boulay-Coletta I, et al. (2011) Multidetector CT angiography in acute gastrointestinal bleeding: why, when, and how. Radiographics 31(3):E35–E46PubMedCrossRef Geffroy Y, Rodallec MH, Boulay-Coletta I, et al. (2011) Multidetector CT angiography in acute gastrointestinal bleeding: why, when, and how. Radiographics 31(3):E35–E46PubMedCrossRef
49.
Zurück zum Zitat Furlan A, Fakhran S, Federle MP (2009) Spontaneous abdominal hemorrhage: causes, CT findings, and clinical implications. AJR Am J Roentgenol 193(4):1077–1087PubMedCrossRef Furlan A, Fakhran S, Federle MP (2009) Spontaneous abdominal hemorrhage: causes, CT findings, and clinical implications. AJR Am J Roentgenol 193(4):1077–1087PubMedCrossRef
50.
51.
Zurück zum Zitat Artigas JM, Martí M, Soto JA, et al. (2013) Multidetector CT angiography for acute gastrointestinal bleeding: technique and findings. Radiographics 33(5):1453–1470PubMedCrossRef Artigas JM, Martí M, Soto JA, et al. (2013) Multidetector CT angiography for acute gastrointestinal bleeding: technique and findings. Radiographics 33(5):1453–1470PubMedCrossRef
52.
Zurück zum Zitat Sin FN, Tsang JP, Siu KL, Ma JK, Yung AW (2012) Medications as causes of intraluminal hyperdensities: what radiologists need to know. Eur J Radiol 81(7):1652–1656PubMedCrossRef Sin FN, Tsang JP, Siu KL, Ma JK, Yung AW (2012) Medications as causes of intraluminal hyperdensities: what radiologists need to know. Eur J Radiol 81(7):1652–1656PubMedCrossRef
53.
Zurück zum Zitat Sun H, Hou XY, Xue HD, et al. (2015) Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: image quality, radiation dose and diagnostic performance. Eur J Radiol 84(5):884–891PubMedCrossRef Sun H, Hou XY, Xue HD, et al. (2015) Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: image quality, radiation dose and diagnostic performance. Eur J Radiol 84(5):884–891PubMedCrossRef
54.
Zurück zum Zitat Lambert JW, FitzGerald PF, Edic PM, et al. (2017) The effect of patient diameter on the dual-energy ratio of selected contrast-producing elements. J Comput Assist Tomogr 41(3):505–510PubMedPubMedCentralCrossRef Lambert JW, FitzGerald PF, Edic PM, et al. (2017) The effect of patient diameter on the dual-energy ratio of selected contrast-producing elements. J Comput Assist Tomogr 41(3):505–510PubMedPubMedCentralCrossRef
55.
Zurück zum Zitat Mongan J, Rathnayake S, Fu Y, et al. (2012) In vivo differentiation of complementary contrast media at dual-energy CT. Radiology 265(1):267–272PubMedPubMedCentralCrossRef Mongan J, Rathnayake S, Fu Y, et al. (2012) In vivo differentiation of complementary contrast media at dual-energy CT. Radiology 265(1):267–272PubMedPubMedCentralCrossRef
56.
Zurück zum Zitat Wiesner W, Khurana B, Ji H, Ros PR (2003) CT of acute bowel ischemia. Radiology 226(3):635–650PubMedCrossRef Wiesner W, Khurana B, Ji H, Ros PR (2003) CT of acute bowel ischemia. Radiology 226(3):635–650PubMedCrossRef
57.
Zurück zum Zitat Potretzke TA, Brace CL, Lubner MG, et al. (2015) Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model. Radiology 275(1):119–126PubMedCrossRef Potretzke TA, Brace CL, Lubner MG, et al. (2015) Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model. Radiology 275(1):119–126PubMedCrossRef
58.
Zurück zum Zitat Fulwadhva UP, Wortman JR, Sodickson AD (2016) Use of dual-energy CT and iodine maps in evaluation of bowel disease. Radiographics. 36(2):393–406PubMedCrossRef Fulwadhva UP, Wortman JR, Sodickson AD (2016) Use of dual-energy CT and iodine maps in evaluation of bowel disease. Radiographics. 36(2):393–406PubMedCrossRef
59.
Zurück zum Zitat Qiu D, Seeram E (2016) Does iterative reconstruction improve image quality and reduce dose in computed tomography? Radiol Open J 1(2):42–54CrossRef Qiu D, Seeram E (2016) Does iterative reconstruction improve image quality and reduce dose in computed tomography? Radiol Open J 1(2):42–54CrossRef
60.
Zurück zum Zitat Willemink MJ, Schilham AM, Leiner T, et al. (2013) Iterative reconstruction does not substantially delay CT imaging in an emergency setting. Insights Imaging 4(3):391–397PubMedPubMedCentralCrossRef Willemink MJ, Schilham AM, Leiner T, et al. (2013) Iterative reconstruction does not substantially delay CT imaging in an emergency setting. Insights Imaging 4(3):391–397PubMedPubMedCentralCrossRef
61.
Zurück zum Zitat Rassouli N, Etesami M, Azz Dhanantwari, et al. (2017) Detector-based spectral CT with a novel dual-layer technology: principles and applications. Insights Imaging 8(6):589–598PubMedPubMedCentralCrossRef Rassouli N, Etesami M, Azz Dhanantwari, et al. (2017) Detector-based spectral CT with a novel dual-layer technology: principles and applications. Insights Imaging 8(6):589–598PubMedPubMedCentralCrossRef
62.
Zurück zum Zitat Aran S, Shaqdan KW, Abujudeh HH (2014) Dual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitations. Emerg Radiol 21(4):391–405PubMedCrossRef Aran S, Shaqdan KW, Abujudeh HH (2014) Dual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitations. Emerg Radiol 21(4):391–405PubMedCrossRef
63.
Zurück zum Zitat Neogi T, Jansen TL, Dalbeth N (2015) 2015 gout classification criteria: an American College of Rheumatology/European League Against Rheumatism collaborative initiative. Arthritis Rheumatol 67(10):2557–2568PubMedPubMedCentralCrossRef Neogi T, Jansen TL, Dalbeth N (2015) 2015 gout classification criteria: an American College of Rheumatology/European League Against Rheumatism collaborative initiative. Arthritis Rheumatol 67(10):2557–2568PubMedPubMedCentralCrossRef
65.
Zurück zum Zitat Xin L, Yang X, Huang N, et al. (2015) The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT. Abdom Imaging 40:2894–2899PubMedCrossRef Xin L, Yang X, Huang N, et al. (2015) The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT. Abdom Imaging 40:2894–2899PubMedCrossRef
66.
Zurück zum Zitat Agrawal MD, Oliveira GR, Kalva SP, et al. (2016) Prospective comparison of reduced-iodine-dose virtual monochromatic imaging dataset from dual-energy CT angiography with standard-iodine-dose single-energy CT angiography for abdominal aortic aneurysm. AJR Am J Roentgenol 207(6):W125–W132PubMedCrossRef Agrawal MD, Oliveira GR, Kalva SP, et al. (2016) Prospective comparison of reduced-iodine-dose virtual monochromatic imaging dataset from dual-energy CT angiography with standard-iodine-dose single-energy CT angiography for abdominal aortic aneurysm. AJR Am J Roentgenol 207(6):W125–W132PubMedCrossRef
67.
Zurück zum Zitat Uhrig M, Simons D, Kachelrieß M, et al. (2016) Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose. Cancer Imaging 16(1):15PubMedPubMedCentralCrossRef Uhrig M, Simons D, Kachelrieß M, et al. (2016) Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose. Cancer Imaging 16(1):15PubMedPubMedCentralCrossRef
68.
Zurück zum Zitat Schick D, Pratap J (2016) Radiation dose efficiency of dual-energy CT benchmarked against single-source, kilovoltage-optimized scans. Br J Radiol 89(1058):20150486PubMedCrossRef Schick D, Pratap J (2016) Radiation dose efficiency of dual-energy CT benchmarked against single-source, kilovoltage-optimized scans. Br J Radiol 89(1058):20150486PubMedCrossRef
69.
Zurück zum Zitat Ho LM, Yoshizumi TT, Hurwitz LM, et al. (2009) Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols. Acad Radiol 16:1400–1407PubMedCrossRef Ho LM, Yoshizumi TT, Hurwitz LM, et al. (2009) Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols. Acad Radiol 16:1400–1407PubMedCrossRef
70.
Zurück zum Zitat De Cecco CN, Darnell A, Macias N, et al. (2013) Second-generation dual-energy computed tomography of the abdomen: radiation dose comparison with 64- and 128-row single-energy acquisition. J Comput Assist Tomogr 37:543–546PubMedCrossRef De Cecco CN, Darnell A, Macias N, et al. (2013) Second-generation dual-energy computed tomography of the abdomen: radiation dose comparison with 64- and 128-row single-energy acquisition. J Comput Assist Tomogr 37:543–546PubMedCrossRef
71.
Zurück zum Zitat Parakh A, Macri F, Sahani D (2018) Dual-energy computed tomography: dose reduction, series reduction, and contrast load reduction in dual-energy computed tomography. Radiol Clin N Am 56(4):601–624PubMedCrossRef Parakh A, Macri F, Sahani D (2018) Dual-energy computed tomography: dose reduction, series reduction, and contrast load reduction in dual-energy computed tomography. Radiol Clin N Am 56(4):601–624PubMedCrossRef
72.
Zurück zum Zitat Ascenti G, Mazziotti S, Mileto A, et al. (2012) Dual-source dual-energy CT evaluation of complex cystic renal masses. AJR Am J Roentgenol 199(5):1026–1034PubMedCrossRef Ascenti G, Mazziotti S, Mileto A, et al. (2012) Dual-source dual-energy CT evaluation of complex cystic renal masses. AJR Am J Roentgenol 199(5):1026–1034PubMedCrossRef
73.
Zurück zum Zitat Dubourg B, Caudron J, Lestrat JP, et al. (2014) Single-source dual-energy CT angiography with reduced iodine load in patients referred for aortoiliofemoral evaluation before transcatheter aortic valve implantation: impact on image quality and radiation dose. Eur Radiol 24(11):2659–2668PubMedCrossRef Dubourg B, Caudron J, Lestrat JP, et al. (2014) Single-source dual-energy CT angiography with reduced iodine load in patients referred for aortoiliofemoral evaluation before transcatheter aortic valve implantation: impact on image quality and radiation dose. Eur Radiol 24(11):2659–2668PubMedCrossRef
74.
Zurück zum Zitat Jepperson MA, Cernigliaro JG, el Ibrahim SH, et al. (2015) In vivo comparison of radiation exposure of dual-energy CT versus low-dose CT versus standard CT for imaging urinary calculi. J Endourol 29(2):141–146PubMedPubMedCentralCrossRef Jepperson MA, Cernigliaro JG, el Ibrahim SH, et al. (2015) In vivo comparison of radiation exposure of dual-energy CT versus low-dose CT versus standard CT for imaging urinary calculi. J Endourol 29(2):141–146PubMedPubMedCentralCrossRef
75.
Zurück zum Zitat Lin XZ, Wu ZY, Tao R, et al. (2012) Dual energy spectral CT imaging of insulinoma-value in preoperative diagnosis compared with conventional multi-detector CT. Eur J Radiol 81(10):2487–2494PubMedCrossRef Lin XZ, Wu ZY, Tao R, et al. (2012) Dual energy spectral CT imaging of insulinoma-value in preoperative diagnosis compared with conventional multi-detector CT. Eur J Radiol 81(10):2487–2494PubMedCrossRef
76.
Zurück zum Zitat Shuman WP, Green DE, Busey JM, et al. (2014) Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase. AJR Am J Roentgenol 203(3):601–606PubMedCrossRef Shuman WP, Green DE, Busey JM, et al. (2014) Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase. AJR Am J Roentgenol 203(3):601–606PubMedCrossRef
77.
Zurück zum Zitat Takeuchi M, Kawai T, Ito M, et al. (2012) Split-bolus CT-urography using dual-energy CT: feasibility, image quality and dose reduction. Eur J Radiol 81(11):3160–3165PubMedCrossRef Takeuchi M, Kawai T, Ito M, et al. (2012) Split-bolus CT-urography using dual-energy CT: feasibility, image quality and dose reduction. Eur J Radiol 81(11):3160–3165PubMedCrossRef
79.
Zurück zum Zitat Wortman JR, Bunch PM, Fulwadhva UP, Bonci GA, Sodickson AD (2016) Dual-energy CT of incidental findings in the abdomen: can we reduce the need for follow-up imaging? AJR Am J Roentgenol 6:W1–W11 Wortman JR, Bunch PM, Fulwadhva UP, Bonci GA, Sodickson AD (2016) Dual-energy CT of incidental findings in the abdomen: can we reduce the need for follow-up imaging? AJR Am J Roentgenol 6:W1–W11
80.
Zurück zum Zitat Deinzer CK, Danova D, Kleb B, et al. (2014) Influence of different iodinated contrast media on the induction of DNA double-strand breaks after in vitro X-ray irradiation. Contrast Media Mol Imaging 9(4):259–267PubMedCrossRef Deinzer CK, Danova D, Kleb B, et al. (2014) Influence of different iodinated contrast media on the induction of DNA double-strand breaks after in vitro X-ray irradiation. Contrast Media Mol Imaging 9(4):259–267PubMedCrossRef
Metadaten
Titel
Role of dual energy CT to improve diagnosis of non-traumatic abdominal vascular emergencies
verfasst von
Khalid W. Shaqdan
Anushri Parakh
Avinash R. Kambadakone
Dushyant V. Sahani
Publikationsdatum
24.08.2018
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 2/2019
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-018-1741-7

Weitere Artikel der Ausgabe 2/2019

Abdominal Radiology 2/2019 Zur Ausgabe

Classics in Abdominal Radiology

The “teardrop sign”

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.