Skip to main content
Erschienen in: Digestive Diseases and Sciences 11/2016

03.08.2016 | Original Article

Safety and Efficacy of a Same-Day Low-Volume 1 L PEG Bowel Preparation in Colonoscopy for the Elderly People and People with Renal Dysfunction

verfasst von: Naohisa Yoshida, Yuji Naito, Takaaki Murakami, Ryohei Hirose, Kiyoshi Ogiso, Yutaka Inada, Osamu Dohi, Tetsuya Okayama, Kazuhiro Kamada, Kazuhiko Uchiyama, Takeshi Ishikawa, Osamu Handa, Hideyuki Konishi, Kewin Tien Ho Siah, Nobuaki Yagi, Yoshito Itoh

Erschienen in: Digestive Diseases and Sciences | Ausgabe 11/2016

Einloggen, um Zugang zu erhalten

Abstract

Introduction

A same-day low-volume 1 L polyethylene glycol (PEG) for bowel preparation before colonoscopy was developed to improve patients’ compliance. We aimed to evaluate the efficacy and safety of this regimen especially for the elderly and patients with renal dysfunction.

Methods

All consecutive patients who underwent colonoscopy in our center from November 2014 to September 2015 were included. Patients undertook a low-residue diet with 10 mL sodium picosulfate 1 day before colonoscopy. Subsequently, they had 1 L low-volume PEG (MoviPrep) and 0.5 L water 4 h before the examination. Clinical outcomes, including cleansing level using the Boston bowel preparation score (BBPS), in the elderly and special-elderly (65–79 and ≥80 years old) were analyzed and compared with the non-elderly (18–64 years old). Additionally, patients with renal dysfunction were analyzed with respect to both complications and changes in blood parameters.

Results

A total of 5427 patients (mean age: 64.5 ± 13.8) were analyzed. The rate of BBPS ≥ 6 in the elderly (2761 patients), special-elderly (565 patients), and non-elderly (2101 patients) was 94.1, 91.8, and 94.6 %, respectively. In the special-elderly, the rate of renal dysfunction was 14.8 %, and no severe complications were detected after colonoscopy. Additionally, there were no severe complications in 86 patients with renal dysfunction, though elevation of hematocrit was shown after intake of 1 L PEG (before, 36.7 ± 6.1 vs. after, 39.0 ± 5.7, P = 0.006).

Conclusions

Our study shows the safety and efficacy of same-day low-volume 1 L PEG bowel preparation in colonoscopy for the elderly and patients with renal dysfunction.
Literatur
1.
Zurück zum Zitat Zauber AG, Winawer SJ, O’Brien MJ, et al. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med. 2012;366:687–696.CrossRefPubMedPubMedCentral Zauber AG, Winawer SJ, O’Brien MJ, et al. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med. 2012;366:687–696.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Yoshida N, Wakabayashi N, Kanemasa K, et al. Endoscopic submucosal dissection for colorectal tumors: technical difficulties and rate of perforation. Endoscopy. 2009;41:758–761.CrossRefPubMed Yoshida N, Wakabayashi N, Kanemasa K, et al. Endoscopic submucosal dissection for colorectal tumors: technical difficulties and rate of perforation. Endoscopy. 2009;41:758–761.CrossRefPubMed
3.
Zurück zum Zitat Tanaka S, Oka S, Kaneko I, et al. Endoscopic submucosal dissection for colorectal neoplasia: possibility of standardization. Gastrointest Endosc. 2007;66:100–107.CrossRefPubMed Tanaka S, Oka S, Kaneko I, et al. Endoscopic submucosal dissection for colorectal neoplasia: possibility of standardization. Gastrointest Endosc. 2007;66:100–107.CrossRefPubMed
4.
Zurück zum Zitat Saito Y, Uraoka T, Yamaguchi Y, et al. A prospective, multicenter study of 1111 colorectal endoscopic submucosal dissections (with video). Gastrointest Endosc. 2010;72:1217–1225.CrossRefPubMed Saito Y, Uraoka T, Yamaguchi Y, et al. A prospective, multicenter study of 1111 colorectal endoscopic submucosal dissections (with video). Gastrointest Endosc. 2010;72:1217–1225.CrossRefPubMed
5.
Zurück zum Zitat Horiuchi A, Nakayama Y, Kajiyama M, et al. Removal of small colorectal polyps in anticoagulated patients: a prospective randomized comparison of cold snare and conventional polypectomy. Gastrointest Endosc. 2014;79:417–423.CrossRefPubMed Horiuchi A, Nakayama Y, Kajiyama M, et al. Removal of small colorectal polyps in anticoagulated patients: a prospective randomized comparison of cold snare and conventional polypectomy. Gastrointest Endosc. 2014;79:417–423.CrossRefPubMed
6.
Zurück zum Zitat Yoshida N, Naito Y, Kugai M, et al. Efficacy of hyaluronic acid in endoscopic mucosal resection for colorectal tumors. J Gastroenterol Hepatol. 2011;26:286–291.CrossRefPubMed Yoshida N, Naito Y, Kugai M, et al. Efficacy of hyaluronic acid in endoscopic mucosal resection for colorectal tumors. J Gastroenterol Hepatol. 2011;26:286–291.CrossRefPubMed
7.
Zurück zum Zitat Yoshida N, Yagi N, Naito Y, Yoshikawa T. Safe procedure in endoscopic submucosal dissection for colorectal tumors focused on preventing complications. World J Gastroenterol. 2010;16:1688–1695.CrossRefPubMedPubMedCentral Yoshida N, Yagi N, Naito Y, Yoshikawa T. Safe procedure in endoscopic submucosal dissection for colorectal tumors focused on preventing complications. World J Gastroenterol. 2010;16:1688–1695.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Froehlich F, Wietlisbach V, Gonvers JJ, et al. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European Multicenter Study. Gastrointest Endosc. 2005;6:378–384.CrossRef Froehlich F, Wietlisbach V, Gonvers JJ, et al. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European Multicenter Study. Gastrointest Endosc. 2005;6:378–384.CrossRef
9.
Zurück zum Zitat Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc. 2003;58:76–79.CrossRefPubMed Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc. 2003;58:76–79.CrossRefPubMed
10.
Zurück zum Zitat Johnson DA, Barkun AN, Cohen LB, et al. Optimizing adequacy of bowel cleansing for colonoscopy: recommendations from the US multi-society task force on colorectal cancer. Gastroenterology. 2014;147:903–924.CrossRefPubMed Johnson DA, Barkun AN, Cohen LB, et al. Optimizing adequacy of bowel cleansing for colonoscopy: recommendations from the US multi-society task force on colorectal cancer. Gastroenterology. 2014;147:903–924.CrossRefPubMed
11.
Zurück zum Zitat Corporaal S, Kleibeuker JH, Koornstra JJ. Low-volume PEG plus ascorbic acid versus high-volume PEG as bowel preparation for colonoscopy. Scand J Gastroenterol. 2010;45:1380–1386.CrossRefPubMed Corporaal S, Kleibeuker JH, Koornstra JJ. Low-volume PEG plus ascorbic acid versus high-volume PEG as bowel preparation for colonoscopy. Scand J Gastroenterol. 2010;45:1380–1386.CrossRefPubMed
12.
Zurück zum Zitat Gentile M, De Rosa M, Cestaro G, Forestieri P. 2 L PEG plus ascorbic acid versus 4 L PEG plus simethicone for colonoscopy preparation: a randomized single-blind clinical trial. Surg Laparosc Endosc Percutan Tech. 2013;23:276–280.CrossRefPubMed Gentile M, De Rosa M, Cestaro G, Forestieri P. 2 L PEG plus ascorbic acid versus 4 L PEG plus simethicone for colonoscopy preparation: a randomized single-blind clinical trial. Surg Laparosc Endosc Percutan Tech. 2013;23:276–280.CrossRefPubMed
13.
Zurück zum Zitat Mathus-Vliegen EM, van der Vliet K. Safety, patient’s tolerance, and efficacy of a 2-liter vitamin C-enriched macrogol bowel preparation: a randomized, endoscopist-blinded prospective comparison with a 4-liter macrogol solution. Dis Colon Rectum. 2013;56:1002–1012.CrossRefPubMed Mathus-Vliegen EM, van der Vliet K. Safety, patient’s tolerance, and efficacy of a 2-liter vitamin C-enriched macrogol bowel preparation: a randomized, endoscopist-blinded prospective comparison with a 4-liter macrogol solution. Dis Colon Rectum. 2013;56:1002–1012.CrossRefPubMed
14.
Zurück zum Zitat Ponchon T, Boustière C, Heresbach D, et al. A low-volume polyethylene glycol plus ascorbate solution for bowel cleansing prior to colonoscopy: the NORMO randomised clinical trial. Dig Liver Dis. 2013;45:820–826.CrossRefPubMed Ponchon T, Boustière C, Heresbach D, et al. A low-volume polyethylene glycol plus ascorbate solution for bowel cleansing prior to colonoscopy: the NORMO randomised clinical trial. Dig Liver Dis. 2013;45:820–826.CrossRefPubMed
15.
Zurück zum Zitat Pontone S, Angelini R, Standoli M, et al. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol. 2011;17:4689–4695.CrossRefPubMedPubMedCentral Pontone S, Angelini R, Standoli M, et al. Low-volume plus ascorbic acid vs high-volume plus simethicone bowel preparation before colonoscopy. World J Gastroenterol. 2011;17:4689–4695.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Tajika M, Tanaka T, Ishihara M, et al. A randomized controlled trial evaluating a low-volume PEG solution plus ascorbic acid versus standard PEG solution in bowel preparation for colonoscopy. Gastroenterol Res Pract. 2015;2015:326581.CrossRefPubMedPubMedCentral Tajika M, Tanaka T, Ishihara M, et al. A randomized controlled trial evaluating a low-volume PEG solution plus ascorbic acid versus standard PEG solution in bowel preparation for colonoscopy. Gastroenterol Res Pract. 2015;2015:326581.CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Lai EJ, Calderwood AH, Doros G, et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009;69:620–625.CrossRefPubMedPubMedCentral Lai EJ, Calderwood AH, Doros G, et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009;69:620–625.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Valiante F, Pontone S, Hassan C, et al. A randomized controlled trial evaluating a new 2-L PEG solution plus ascorbic acid vs 4-L PEG for bowel cleansing prior to colonoscopy. Dig Liver Dis. 2012;44:224–227.CrossRefPubMed Valiante F, Pontone S, Hassan C, et al. A randomized controlled trial evaluating a new 2-L PEG solution plus ascorbic acid vs 4-L PEG for bowel cleansing prior to colonoscopy. Dig Liver Dis. 2012;44:224–227.CrossRefPubMed
19.
Zurück zum Zitat Seo EH, Kim TO, Park MJ, et al. Low-volume morning-only polyethylene glycol with specially designed test meals versus standard-volume split-dose polyethylene glycol with standard diet for colonoscopy: a prospective, randomized trial. Digestion. 2013;88:110–118.CrossRefPubMed Seo EH, Kim TO, Park MJ, et al. Low-volume morning-only polyethylene glycol with specially designed test meals versus standard-volume split-dose polyethylene glycol with standard diet for colonoscopy: a prospective, randomized trial. Digestion. 2013;88:110–118.CrossRefPubMed
20.
Zurück zum Zitat Hookey LC, Depew WT, Vanner SJ. Combined low volume polyethylene glycol solution plus stimulant laxatives versus standard volume polyethylene glycol solution: a prospective, randomized study of colon cleansing before colonoscopy. Can J Gastroenterol. 2006;20:101–105.CrossRefPubMedPubMedCentral Hookey LC, Depew WT, Vanner SJ. Combined low volume polyethylene glycol solution plus stimulant laxatives versus standard volume polyethylene glycol solution: a prospective, randomized study of colon cleansing before colonoscopy. Can J Gastroenterol. 2006;20:101–105.CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Hassan C, Fuccio L, Bruno M, et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol. 2012;10:501–506.CrossRefPubMed Hassan C, Fuccio L, Bruno M, et al. A predictive model identifies patients most likely to have inadequate bowel preparation for colonoscopy. Clin Gastroenterol Hepatol. 2012;10:501–506.CrossRefPubMed
22.
Zurück zum Zitat Lebwohl B, Wang TC, Neugut AI. Socioeconomic and other predictors of colonoscopy preparation quality. Dig Dis Sci. 2010;55:2014–2020.CrossRefPubMed Lebwohl B, Wang TC, Neugut AI. Socioeconomic and other predictors of colonoscopy preparation quality. Dig Dis Sci. 2010;55:2014–2020.CrossRefPubMed
23.
Zurück zum Zitat Ness RM, Manam R, Hoen H, Chalasani N. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol. 2001;96:1797–1802.CrossRefPubMed Ness RM, Manam R, Hoen H, Chalasani N. Predictors of inadequate bowel preparation for colonoscopy. Am J Gastroenterol. 2001;96:1797–1802.CrossRefPubMed
24.
25.
Zurück zum Zitat Taylor C, Schubert ML. Decreased efficacy of polyethylene glycol lavage solution (golytely) in the preparation of diabetic patients for outpatient colonoscopy: a prospective and blinded study. Am J Gastroenterol. 2001;96:710–714.CrossRefPubMed Taylor C, Schubert ML. Decreased efficacy of polyethylene glycol lavage solution (golytely) in the preparation of diabetic patients for outpatient colonoscopy: a prospective and blinded study. Am J Gastroenterol. 2001;96:710–714.CrossRefPubMed
26.
Zurück zum Zitat Lim SW, Seo YW, Sinn DH, et al. Impact of previous gastric or colonic resection on polyethylene glycol bowel preparation for colonoscopy. Surg Endosc. 2012;26:1554–1559.CrossRefPubMed Lim SW, Seo YW, Sinn DH, et al. Impact of previous gastric or colonic resection on polyethylene glycol bowel preparation for colonoscopy. Surg Endosc. 2012;26:1554–1559.CrossRefPubMed
27.
Zurück zum Zitat Chokshi RV, Hovis CE, Hollander T, et al. Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy. Gastrointest Endosc. 2012;75:1197–1203.CrossRefPubMed Chokshi RV, Hovis CE, Hollander T, et al. Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy. Gastrointest Endosc. 2012;75:1197–1203.CrossRefPubMed
28.
Zurück zum Zitat Horimatsu T, Sano Y, Tanaka S, et al. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial. Int J Colorectal Dis. 2015;30:947–954.CrossRefPubMed Horimatsu T, Sano Y, Tanaka S, et al. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial. Int J Colorectal Dis. 2015;30:947–954.CrossRefPubMed
29.
Zurück zum Zitat Yoshida N, Hisabe T, Hirose R, et al. 2015) Improvement in the visibility of colorectal polyps by using blue laser imaging (with video. Gastrointest Endosc. 2015;82:542–549.CrossRefPubMed Yoshida N, Hisabe T, Hirose R, et al. 2015) Improvement in the visibility of colorectal polyps by using blue laser imaging (with video. Gastrointest Endosc. 2015;82:542–549.CrossRefPubMed
Metadaten
Titel
Safety and Efficacy of a Same-Day Low-Volume 1 L PEG Bowel Preparation in Colonoscopy for the Elderly People and People with Renal Dysfunction
verfasst von
Naohisa Yoshida
Yuji Naito
Takaaki Murakami
Ryohei Hirose
Kiyoshi Ogiso
Yutaka Inada
Osamu Dohi
Tetsuya Okayama
Kazuhiro Kamada
Kazuhiko Uchiyama
Takeshi Ishikawa
Osamu Handa
Hideyuki Konishi
Kewin Tien Ho Siah
Nobuaki Yagi
Yoshito Itoh
Publikationsdatum
03.08.2016
Verlag
Springer US
Erschienen in
Digestive Diseases and Sciences / Ausgabe 11/2016
Print ISSN: 0163-2116
Elektronische ISSN: 1573-2568
DOI
https://doi.org/10.1007/s10620-016-4262-7

Weitere Artikel der Ausgabe 11/2016

Digestive Diseases and Sciences 11/2016 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.