Abstract

Purpose

We aimed to determine the sensitivity and specificity of the normative database of non-myopic and highly myopic eyes of the macular ganglion cell complex (mGCC) thickness embedded in the NIDEK RS-3000 spectral-domain optical coherence tomography (SD-OCT) for detecting early glaucoma in highly myopic eyes.

Methods

Forty-seven highly myopic eyes (axial length ≥26.0 mm) of 47 subjects were studied. The SD-OCT images were used to determine the mGCC thickness within a 9-mm diameter circle centered on the fovea. The sensitivity and specificity of the non-myopic database were compared to that of the highly myopic database for distinguishing the early glaucomatous eyes from the non-glaucomatous eyes. The mGCC scans were classified as abnormal if at least one of the eight sectors of the significance map was < 1 % of the normative thickness.

Results

Twenty-one eyes were diagnosed to be non-glaucomatous and 26 eyes to have early glaucoma. . The average mGCC thickness was significantly thinner (80.9 ± 8.5 μm) in the early glaucoma group than in the non-glaucomatous group (91.2 ± 7.5 μm; p <1 × 10−4). The sensitivity was 96.2 % and specificity was 47.6 % when the non-myopic database was used, and the sensitivity was 92.3 % and the specificity was 90.5 % when the highly myopic database was used. The difference in the specificity was significant (p < 0.01).

Conclusions

The significantly higher specificity of the myopic normative database for detecting early glaucoma in highly myopic eyes will lead to fewer false positive diagnoses. The database obtained from highly myopic eyes should be used when evaluating the mGCC thickness of highly myopic eyes.
Literatur
1.
Zurück zum Zitat Bourne RRA, Stevens GA, White RA et al (2013) Causes of vision loss worldwide, 1990–2010: a systematic analysis. Lancet Glob Health 1:e339–e349PubMedCrossRef Bourne RRA, Stevens GA, White RA et al (2013) Causes of vision loss worldwide, 1990–2010: a systematic analysis. Lancet Glob Health 1:e339–e349PubMedCrossRef
2.
Zurück zum Zitat Klein R, Klein BEK (2013) The prevalence of age-related eye diseases and visual impairment in aging: current estimates. Invest Ophthalmol Vis Sci 54:ORSF5–ORSF13PubMedCentralPubMedCrossRef Klein R, Klein BEK (2013) The prevalence of age-related eye diseases and visual impairment in aging: current estimates. Invest Ophthalmol Vis Sci 54:ORSF5–ORSF13PubMedCentralPubMedCrossRef
3.
Zurück zum Zitat Tham Y-C, Li X, Wong TY et al (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology 121:2081–2090PubMedCrossRef Tham Y-C, Li X, Wong TY et al (2014) Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology 121:2081–2090PubMedCrossRef
4.
Zurück zum Zitat Iester M, Zingirian M (2002) Quality of life in patients with early, moderate and advanced glaucoma. Eye 16:44–49PubMedCrossRef Iester M, Zingirian M (2002) Quality of life in patients with early, moderate and advanced glaucoma. Eye 16:44–49PubMedCrossRef
5.
Zurück zum Zitat Goldberg I, Clement CI, Chiang TH et al (2009) Assessing quality of life in patients with glaucoma using the glaucoma quality of life-15 (GQL-15) questionnaire. J Glaucoma 18:6–12PubMedCrossRef Goldberg I, Clement CI, Chiang TH et al (2009) Assessing quality of life in patients with glaucoma using the glaucoma quality of life-15 (GQL-15) questionnaire. J Glaucoma 18:6–12PubMedCrossRef
6.
Zurück zum Zitat Shaikh Y, Yu F, Coleman AL (2014) Burden of undetected and untreated glaucoma in the United States. Am J Ophthalmol 158:1121.e1–1129.e1CrossRef Shaikh Y, Yu F, Coleman AL (2014) Burden of undetected and untreated glaucoma in the United States. Am J Ophthalmol 158:1121.e1–1129.e1CrossRef
7.
Zurück zum Zitat Quigley HA, Dunkelberger GR, Green WR (1989) Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol 107:453–464PubMedCrossRef Quigley HA, Dunkelberger GR, Green WR (1989) Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol 107:453–464PubMedCrossRef
8.
Zurück zum Zitat Weinreb RN, Friedman DS, Fechtner RD et al (2004) Risk assessment in the management of patients with ocular hypertension. Am J Ophthalmol 138:458–467PubMedCrossRef Weinreb RN, Friedman DS, Fechtner RD et al (2004) Risk assessment in the management of patients with ocular hypertension. Am J Ophthalmol 138:458–467PubMedCrossRef
9.
Zurück zum Zitat Grossniklaus HE, Green WR (1992) Pathologic findings in pathologic myopia. Retina 12:127–133PubMedCrossRef Grossniklaus HE, Green WR (1992) Pathologic findings in pathologic myopia. Retina 12:127–133PubMedCrossRef
10.
Zurück zum Zitat Chihara E, Chihara K (1994) Covariation of optic disc measurements and ocular parameters in the healthy eye. Graefes Arch Clin Exp Ophthalmol 232:265–271PubMedCrossRef Chihara E, Chihara K (1994) Covariation of optic disc measurements and ocular parameters in the healthy eye. Graefes Arch Clin Exp Ophthalmol 232:265–271PubMedCrossRef
11.
Zurück zum Zitat Jonas JB, Dichtl A (1997) Optic disc morphology in myopic primary open-angle glaucoma. Graefes Arch Clin Exp Ophthalmol 235:627–633PubMedCrossRef Jonas JB, Dichtl A (1997) Optic disc morphology in myopic primary open-angle glaucoma. Graefes Arch Clin Exp Ophthalmol 235:627–633PubMedCrossRef
12.
Zurück zum Zitat Tay E, Seah SK, Chan SP et al (2005) Optic disk ovality as an index of tilt and its relationship to myopia and perimetry. Am J Ophthalmol 139:247–252PubMedCrossRef Tay E, Seah SK, Chan SP et al (2005) Optic disk ovality as an index of tilt and its relationship to myopia and perimetry. Am J Ophthalmol 139:247–252PubMedCrossRef
13.
Zurück zum Zitat Tan O, Chopra V, Lu AT-H et al (2009) Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography. Ophthalmology 116:2305.e1–2–2314.e1–2CrossRef Tan O, Chopra V, Lu AT-H et al (2009) Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography. Ophthalmology 116:2305.e1–2–2314.e1–2CrossRef
14.
Zurück zum Zitat Mori S, Hangai M, Sakamoto A, Yoshimura N (2010) Spectral-domain optical coherence tomography measurement of macular volume for diagnosing glaucoma. J Glaucoma 19:528–534PubMedCrossRef Mori S, Hangai M, Sakamoto A, Yoshimura N (2010) Spectral-domain optical coherence tomography measurement of macular volume for diagnosing glaucoma. J Glaucoma 19:528–534PubMedCrossRef
15.
Zurück zum Zitat Rolle T, Briamonte C, Curto D, Grignolo FM (2011) Ganglion cell complex and retinal nerve fiber layer measured by fourier-domain optical coherence tomography for early detection of structural damage in patients with preperimetric glaucoma. Clin Ophthalmol 5:961–969PubMedCentralPubMedCrossRef Rolle T, Briamonte C, Curto D, Grignolo FM (2011) Ganglion cell complex and retinal nerve fiber layer measured by fourier-domain optical coherence tomography for early detection of structural damage in patients with preperimetric glaucoma. Clin Ophthalmol 5:961–969PubMedCentralPubMedCrossRef
16.
Zurück zum Zitat Morooka S, Hangai M, Nukada M et al (2012) Wide 3-dimensional macular ganglion cell complex imaging with spectral-domain optical coherence tomography in glaucoma. Invest Ophthalmol Vis Sci 53:4805–4812PubMedCrossRef Morooka S, Hangai M, Nukada M et al (2012) Wide 3-dimensional macular ganglion cell complex imaging with spectral-domain optical coherence tomography in glaucoma. Invest Ophthalmol Vis Sci 53:4805–4812PubMedCrossRef
17.
Zurück zum Zitat Kim NR, Lee ES, Seong GJ et al (2011) Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br J Ophthalmol 95:1115–1121PubMedCrossRef Kim NR, Lee ES, Seong GJ et al (2011) Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br J Ophthalmol 95:1115–1121PubMedCrossRef
18.
Zurück zum Zitat Kim YJ, Kang MH, Cho HY, et al. (2014) Comparative study of macular ganglion cell complex thickness measured by spectral-domain optical coherence tomography in healthy eyes, eyes with preperimetric glaucoma, and eyes with early glaucoma. Jpn J Ophthalmol 58:244–251 Kim YJ, Kang MH, Cho HY, et al. (2014) Comparative study of macular ganglion cell complex thickness measured by spectral-domain optical coherence tomography in healthy eyes, eyes with preperimetric glaucoma, and eyes with early glaucoma. Jpn J Ophthalmol 58:244–251
19.
Zurück zum Zitat Wakitani Y, Sasoh M, Sugimoto M et al (2003) Macular thickness measurements in healthy subjects with different axial lengths using optical coherence tomography. Retina 23:177–182PubMedCrossRef Wakitani Y, Sasoh M, Sugimoto M et al (2003) Macular thickness measurements in healthy subjects with different axial lengths using optical coherence tomography. Retina 23:177–182PubMedCrossRef
20.
Zurück zum Zitat Realini T, Zangwill LM, Flanagan JG et al (2014) Normative databases for imaging instrumentation. J Glaucoma Realini T, Zangwill LM, Flanagan JG et al (2014) Normative databases for imaging instrumentation. J Glaucoma
21.
Zurück zum Zitat Knight OJ, Girkin CA, Budenz DL et al (2012) Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT. Arch Ophthalmol 130:312–318PubMedCrossRef Knight OJ, Girkin CA, Budenz DL et al (2012) Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT. Arch Ophthalmol 130:312–318PubMedCrossRef
24.
Zurück zum Zitat Nidek Reference material for the RS-3000 Normative database. NDB Clinical Report1-071210. Available by contact to Nidek. Co., Ltd. Obtained 22 December 2014 Nidek Reference material for the RS-3000 Normative database. NDB Clinical Report1-071210. Available by contact to Nidek. Co., Ltd. Obtained 22 December 2014
25.
Zurück zum Zitat Nidek Reference material for the RS-3000 Long Axial Length Normative Database. Long Axial Length NDB Clinical Report-060914. Available by contact to Nidek. Co., Ltd. Obtained 22 December 2014 Nidek Reference material for the RS-3000 Long Axial Length Normative Database. Long Axial Length NDB Clinical Report-060914. Available by contact to Nidek. Co., Ltd. Obtained 22 December 2014
26.
Zurück zum Zitat Anderson DR, Patella VM (1999) Automated static perimetry, 2nd edn. Mosby, StLouis, pp 121–190 Anderson DR, Patella VM (1999) Automated static perimetry, 2nd edn. Mosby, StLouis, pp 121–190
27.
Zurück zum Zitat Bennett AG, Rudnicka AR, Edgar DF (1994) Improvements on Littmann’s method of determining the size of retinal features by fundus photography. Graefes Arch Clin Exp Ophthalmol 232:361–367PubMedCrossRef Bennett AG, Rudnicka AR, Edgar DF (1994) Improvements on Littmann’s method of determining the size of retinal features by fundus photography. Graefes Arch Clin Exp Ophthalmol 232:361–367PubMedCrossRef
28.
29.
30.
Zurück zum Zitat Araie M, Arai M, Koseki N, Suzuki Y (1995) Influence of myopic refraction on visual field defects in normal tension and primary open angle glaucoma. Jpn J Ophthalmol 39:60–64PubMed Araie M, Arai M, Koseki N, Suzuki Y (1995) Influence of myopic refraction on visual field defects in normal tension and primary open angle glaucoma. Jpn J Ophthalmol 39:60–64PubMed
31.
Zurück zum Zitat Mayama C, Suzuki Y, Araie M et al (2002) Myopia and advanced-stage open-angle glaucoma. Ophthalmology 109:2072–2077PubMedCrossRef Mayama C, Suzuki Y, Araie M et al (2002) Myopia and advanced-stage open-angle glaucoma. Ophthalmology 109:2072–2077PubMedCrossRef
32.
Zurück zum Zitat Kimura Y, Hangai M, Morooka S et al (2012) Retinal nerve fiber layer defects in highly myopic eyes with early glaucoma. Invest Ophthalmol Vis Sci 53:6472–6478PubMedCrossRef Kimura Y, Hangai M, Morooka S et al (2012) Retinal nerve fiber layer defects in highly myopic eyes with early glaucoma. Invest Ophthalmol Vis Sci 53:6472–6478PubMedCrossRef
33.
Zurück zum Zitat Chong GT, Lee RK (2012) Glaucoma versus red disease: imaging and glaucoma diagnosis. Curr Opin Ophthalmol 23:79–88PubMedCrossRef Chong GT, Lee RK (2012) Glaucoma versus red disease: imaging and glaucoma diagnosis. Curr Opin Ophthalmol 23:79–88PubMedCrossRef
34.
Zurück zum Zitat Nakano N, Hangai M, Noma H et al (2013) Macular imaging in highly myopic eyes with and without glaucoma. Am J Ophthalmol 156:511.e6–523.e6CrossRef Nakano N, Hangai M, Noma H et al (2013) Macular imaging in highly myopic eyes with and without glaucoma. Am J Ophthalmol 156:511.e6–523.e6CrossRef
35.
Zurück zum Zitat Hirasawa K, Shoji N (2013) Association between ganglion cell complex and axial length. Jpn J Ophthalmol 57:429–434PubMedCrossRef Hirasawa K, Shoji N (2013) Association between ganglion cell complex and axial length. Jpn J Ophthalmol 57:429–434PubMedCrossRef
36.
Zurück zum Zitat Takeyama A, Kita Y, Kita R, Tomita G (2014) Influence of axial length on ganglion cell complex (GCC) thickness and on GCC thickness to retinal thickness ratios in young adults. Jpn J Ophthalmol 58:86–93PubMedCrossRef Takeyama A, Kita Y, Kita R, Tomita G (2014) Influence of axial length on ganglion cell complex (GCC) thickness and on GCC thickness to retinal thickness ratios in young adults. Jpn J Ophthalmol 58:86–93PubMedCrossRef
37.
Zurück zum Zitat Bagga H, Greenfield DS, Knighton RW (2005) Macular symmetry testing for glaucoma detection. J Glaucoma 14:358–363PubMedCrossRef Bagga H, Greenfield DS, Knighton RW (2005) Macular symmetry testing for glaucoma detection. J Glaucoma 14:358–363PubMedCrossRef
38.
Zurück zum Zitat Yamada H, Hangai M, Nakano N et al (2014) Asymmetry analysis of macular inner retinal layers for glaucoma diagnosis. Am J Ophthalmol 158:1318–1329.e3PubMedCrossRef Yamada H, Hangai M, Nakano N et al (2014) Asymmetry analysis of macular inner retinal layers for glaucoma diagnosis. Am J Ophthalmol 158:1318–1329.e3PubMedCrossRef
39.
Zurück zum Zitat Asrani S, Rosdahl JA, Allingham RR (2011) Novel software strategy for glaucoma diagnosis: asymmetry analysis of retinal thickness. Arch Ophthalmol 129:1205–1211PubMedCrossRef Asrani S, Rosdahl JA, Allingham RR (2011) Novel software strategy for glaucoma diagnosis: asymmetry analysis of retinal thickness. Arch Ophthalmol 129:1205–1211PubMedCrossRef
40.
Zurück zum Zitat Shoji T, Nagaoka Y, Sato H, Chihara E (2012) Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma. Graefes Arch Clin Exp Ophthalmol 250:1843–1849PubMedCrossRef Shoji T, Nagaoka Y, Sato H, Chihara E (2012) Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma. Graefes Arch Clin Exp Ophthalmol 250:1843–1849PubMedCrossRef
41.
Zurück zum Zitat Kanamori A, Naka M, Akashi A et al (2013) Cluster analyses of grid-pattern display in macular parameters using optical coherence tomography for glaucoma diagnosis. Investig Ophthalmol Vis Sci 54:6401–6408CrossRef Kanamori A, Naka M, Akashi A et al (2013) Cluster analyses of grid-pattern display in macular parameters using optical coherence tomography for glaucoma diagnosis. Investig Ophthalmol Vis Sci 54:6401–6408CrossRef
42.
Zurück zum Zitat Kimura Y, Hangai M, Matsumoto A et al (2013) Macular structure parameters as an automated indicator of paracentral scotoma in early glaucoma. Am J Ophthalmol 156:907–917 e1PubMedCrossRef Kimura Y, Hangai M, Matsumoto A et al (2013) Macular structure parameters as an automated indicator of paracentral scotoma in early glaucoma. Am J Ophthalmol 156:907–917 e1PubMedCrossRef
43.
Zurück zum Zitat Kim MJ, Jeoung JW, Park KH et al (2014) Topographic profiles of retinal nerve fiber layer defects affect the diagnostic performance of macular scans in preperimetric glaucoma. Investig Ophthalmol Vis Sci 55:2079–2087CrossRef Kim MJ, Jeoung JW, Park KH et al (2014) Topographic profiles of retinal nerve fiber layer defects affect the diagnostic performance of macular scans in preperimetric glaucoma. Investig Ophthalmol Vis Sci 55:2079–2087CrossRef
44.
Zurück zum Zitat Mwanza JC, Budenz DL, Godfrey DG et al (2014) Diagnostic performance of optical coherence tomography ganglion cell-inner plexiform layer thickness measurements in early glaucoma. Ophthalmology 121:849–854PubMedCrossRef Mwanza JC, Budenz DL, Godfrey DG et al (2014) Diagnostic performance of optical coherence tomography ganglion cell-inner plexiform layer thickness measurements in early glaucoma. Ophthalmology 121:849–854PubMedCrossRef
Metadaten
Titel
Sensitivity and specificity for detecting early glaucoma in eyes with high myopia from normative database of macular ganglion cell complex thickness obtained from normal non-myopic or highly myopic Asian eyes
verfasst von
Hideo Nakanishi
Tadamichi Akagi
Masanori Hangai
Yugo Kimura
Kenji Suda
Kyoko Kawashima Kumagai
Satoshi Morooka
Hanako Ohashi Ikeda
Nagahisa Yoshimura
Publikationsdatum
01.07.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 7/2015
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-015-3026-y

Weitere Artikel der Ausgabe 7/2015

Graefe's Archive for Clinical and Experimental Ophthalmology 7/2015 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.