Skip to main content
Erschienen in: Obere Extremität 2/2019

Open Access 04.04.2019 | Review Article

Short-stem anatomical shoulder replacement—a systematic review

verfasst von: Marc Schnetzke, MD, Markus Loew, Patric Raiss, Gilles Walch

Erschienen in: Obere Extremität | Ausgabe 2/2019

Abstract

Background

In shoulder arthroplasty, there is a trend for shorter humeral implants to facilitate stem revision and preserve bone stock. This review evaluates the clinical and radiographic outcome of anatomical total shoulder replacement with uncemented humeral short stems.

Methods

A systematic review was performed using PubMed and Cochrane databases. The search terms “short stem” (all) and “shoulder” (title/abstract) were used. The minimum follow-up was 20 months. The demographic data, clinical outcome (pain, range of motion, outcome scores), radiographic outcome (humeral bone adaptations, humeral loosening, glenoid loosening), risk for high radiographic bone adaptations, complications, and revision were determined.

Results

Ten studies comprising 653 shoulder arthroplasties were included in the analysis. At an average follow-up of 20–64 months, the clinical parameters of pain, range of motion, and outcome scores improved significantly in all studies. The most frequent radiographic finding was calcar resorption in 15–71% of patients. High filling ratio, lack of metaphyseal porous coating, and poor bone quality were associated with high bone adaptation. The radiographic changes did not influence the clinical outcome in any study. In 13 of 653 patients (2%), humeral stem loosening was observed leading to stem revision in nine patients, with one study reporting eight of 73 patients with humeral stem loosening. The average weighted complication rate was 6% and the average weighted revision rate was 4%.

Conclusion

The short- to medium-term results of uncemented anatomical short-stem shoulder arthroplasty are encouraging and the clinical results are comparable to other 3rd- and 4th-generation shoulder arthroplasties. Further studies with longer follow-up are needed to evaluate and understand why the radiographic changes occur and to prove the theory of bone-sparing revision surgeries.
Anatomical shoulder replacement has been established as a successful treatment option in shoulder pathologies, such as glenohumeral arthritis, inflammatory arthritis, or avascular necrosis of the humerus [10, 17, 28, 31]. The third generation of shoulder arthroplasty with standard-length humeral stems yields good to excellent long-term results. However, standard-length humeral stems are associated with high rates of stress shielding and a risk of proximal humeral bone loss in the case of revision surgery [1, 3, 6, 27].
Standard-length humeral stems are linked to high rates of stress shielding
In an effort to mimic native bone stress and to preserve bone in the case of revision surgery, design modifications led to the fourth generation of shoulder arthroplasty with stemless or short-stem humeral components aimed at metaphyseal fixation [7, 11, 14]. In 2016, Harmer et al. performed a systematic review of stemless and short-stem shoulder prosthesis and found that only one study reported results of anatomical shoulder replacement with an uncemented short stem [11]. The authors therefore concluded that longer-term and better-designed studies are needed if short stems and stemless components are to become the gold standard for care.
Since then, several studies have reported results of anatomical shoulder replacement with uncemented short stems. In 2016, Casagrande et al. reported their experience with an uncemented short-stem shoulder prosthesis in 73 patients [5]. Six of the 73 patients underwent revision surgery due to loosening of the humeral stem within a mean follow-up period of 28 months. These alarming results necessitate a systematic review of the clinical and radiographic outcome of short-stem anatomical shoulder replacement. This review aimed to evaluate the clinical and radiographic outcome of anatomical total shoulder replacement with uncemented humeral short stems. A secondary aim was to identify and summarize potential risk factors associated with stem loosening in short-stem shoulder arthroplasty.

Methods

A systematic review was performed following the checklist of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). A search using the terms “short stem” (all) and “shoulder” (title/abstract) was undertaken by two reviewers using the PubMed and Cochrane Central Register of Controlled Trials databases. Studies were included in the current review if they met following inclusion criteria: implantation of an uncemented humeral short stem and original studies of human subjects with evidence level I to IV with a minimum follow-up of 20 months.
Short-stem prostheses are designed with a standard shaped stem with a length of <100 mm from head to tip. The implant ends distally in the diaphyseal intramedullary canal without touching the cortex. The stem is fixed and stabilized within the metaphysis. By contrast, standard stem prostheses are longer (>110 mm). They are fixed at the metaphyseal cortex, either “press fit” or with bone cement. In a stemless prosthesis, the implant does not enter the medullary canal of the diaphysis.
Many different indications for anatomical shoulder replacement were included. The titles and abstracts were reviewed for suitability.
Among studies reporting heterogeneous treatments (i. e., standard length and short-stem shoulder arthroplasty), only those that reported outcomes for short-stem shoulder arthroplasty separately were included. Studies reporting on duplicate studies of the same patient cohorts were excluded. Full-text references were reviewed to identify any previously unidentified studies related to the study topic. A flow chart summarizing this selection algorithm is shown in Fig. 1. The demographic data, clinical outcome (pain, range of motion, outcome scores), radiographic outcome (humeral bone adaptations, humeral loosening, glenoid loosening), risk for high radiographic bone adaptations, complications, and revision were determined. Where possible, weighted means were calculated for outcome variables.

Results

Ten studies met the inclusion criteria and were analyzed in the current review. Eight of the ten studies were case series (level IV therapeutic studies), one study was a retrospective comparative study (level III), and one was a prospective case series (level II). Four different kinds of short-stem prostheses were implanted in the studies: Apex (Apex; Arthrex, Inc., Naples, FL, USA), Ascend Monolithic (Ascend Monolithic, Wright Medical, Memphis, TN, USA), Ascend Flex (Ascend Flex, Wright Medical, Memphis, TN, USA), and Biomet Comprehensive Mini/Micro stem (Bio-Modular Shoulder Mini Stem; Biomet Inc., Warsaw, IN, USA). The characteristics of these short-stem prostheses are listed in Table 1.
Table 1
Overview of short-stem shoulder prostheses
Prosthesis
Stem length
Proximal porous coating
Convertibility
Inclination
Offset
Apex
60–65 mm
Yes
No
125–140°
0–3.5 mm
Ascend Monolithic
66–98 mm
No
No
125–140°
1.5 mm, 3.5 mm, 4 mm
Ascend Flex
66–98 mm
Yes
Yes
125–140°
1.5 mm, 3.5 mm, 4 mm
Biomet Comprehensive Micro/Mini Stem
55 mm and 83 mm
Yes
Yes
135°
0.5–4.5 mm
A series of publications conducted at the ATOS Clinic Heidelberg (Germany) and the Orthopédique Santy in Lyon (France) were identified [2224], and the most recent of these three studies is included in this review. Three multicenter studies [8, 9, 21] performed in the United States and reporting the outcome of patients treated with two kinds of short-stem shoulder arthroplasties are included. The studies by Romeo et al. [21] and by Denard et al. [9] are included in the analysis. One longitudinal study by Schnetzke et al. [25] that reported on the outcome at two different time points (2.6 and 5.3 years) was included. The other studies included one final follow-up without a direct longitudinal comparison with the same cohorts at previous time points.

Demographics

In 2011, Jost et al. reported the results of 49 anatomical short-stem shoulder replacements using the Biomet Comprehensive™ (BC) with mini and micro stems (Table 2; [13]). In 2010, Wright/Tornier launched their first type of short-stem prosthesis, the Ascend Monolithic™ (AM), which did not include the option for convertibility or proximal porous coating. There are four studies available reporting on the outcome of 255 patients treated with the AM for different indications. Subsequently, design modifications led to the second generation of short-stem prostheses, the Ascend Flex™ (AF), with a more voluminous and rough titanium porous-coated metaphyseal part and with convertibility from anatomic to reversed design. Six different studies reported the outcome of 288 patients treated with the AF prosthesis for different indications.
The study by Raiss et al. reports only the radiographic results of 150 patients treated with the AF prosthesis [18]. The clinical results of a part of this patient cohort (n = 65) were published by Schnetzke et al. in a separate study [26]. In the studies by Morwood et al. [15] and Szerlip et al. [29] the outcome of the AM and the AF was compared. Denard and coworkers [9] did not differentiate between shoulders treated with AM or AF. Finally, Arthrex has developed a short-stem shoulder prosthesis called Apex™ (AP) and Romeo et al. [21] reported on the outcome of 64 patients treated with this kind of prosthesis for primary or secondary osteoarthritis.
Table 2
Demographics from studies of anatomical shoulder replacement
Study
Prosthesis type
No. of shoulders
Age
Male sex
Dominant side
Indication for TSA
(range)
(%)
(%)
(n)
Jost (2011) [13]
Biomet Comp
49
67 (46–83)
23 (47)
NR
Primary OA (49)
Casagrande (2016) [5]
Ascend Mono
69
64 (39–86)
38 (55)
15 (52)
Primary OA (62), posttraumatic OA (2), RA (2), AVN (3)
Schnetzke (2017) [24]
Ascend Flex
29
63 (38–79)
12 (41)
15 (52)
Primary OA (18), posttraumatic OA (8), RA (1), AVN (2)
Morwood (2017) [15]
Ascend Mono
34
69
NR
NR
Primary OA (57), posttraumatic OA (5), instability OA (2), AVN (4)
Ascend Flex
34
70
Szerlip (2018) [29]
Ascend Mono
85
67 (25–93)
74 (63)
53 (45)
Primary OA (100), posttraumatic OA (4), instability OA (10), revision (3), RA (1)
Ascend Flex
33
Romeo (2018) [21]
Apex
64
64
NR
NR
Primary or posttraumatic OA (NR)
Denard (2018) [8]
Ascend Mono
42
68 (36–84)
28 (67)
22 (55)
NR
Ascend Flex
Schnetzke (2018) [25]
Ascend Mono
67
76 (63–92)
24 (36)
34 (51)
Primary OA (67)
Schnetzke (2018) [26]
Ascend Flex
65
70 (47–85)
27 (42)
35 (53)
Primary OA (65)
Raiss (2018) [18]
Ascend Flex
150a
68 (30–85)
NR
81 (54)
Primary OA (150)
AVN avascular necrosis, NR not reported, OA osteoarthritis, RA rheumatoid arthritis, TSA total shoulder arthroplasty
aOnly radiographic results

Clinical results

Clinical outcome was reported for 571 shoulders with a mean follow-up of 28 months (range: 20–84). Significant reduction of pain and improvement in range of motion as well as improvement of the outcome scores from preoperative status to final follow-up were reported in all studies (Table 3). Three studies used the standard visual analog scale for (VAS; 0 = best, 10 = worst) for reporting pain improvement. In these studies, the VAS significantly decreased from 6.0 to 1.3 at the final follow-up. Five studies used the pain component of the Constant–Murley scoring system (0 = worst, 15 = best) and one study used the pain component of the American Shoulder and Elbow Surgeons shoulder score (ASES; 0 = best, 10 = worst). The Constant–Murley score (CMS) showed a statistically significant improvement in pain in the studies included, with an average change from 4.4 to 13.2 at 8.8 years. One study that used the ASES pain score also reported a significant decrease in pain (5.2 to 0.9).
Table 3
Clinical outcome after anatomical shoulder replacement
Study/implant
No. of shoulders
Follow-up, months
ROM pre
ROM post
Pain pre
Pain post
Outcome score pre
Outcome score post
(range)
(SD)
(SD)
(SD)
(SD)
(SD)
(SD)
Jost (2011) [13]
49
29 (24–43)
Abd: 69
Abd: 136
NR
VASm: 4.5
NR
CS: 91
Biomet Comprehensive
Flex: 88
Flex: 142
UCLA: 27.5
ER: 23
ER: 63
Casagrande (2016) [5]
69
28 (24–48)
Abd: 90
Abd: 129
ASES: 5.2
ASES: 0.9
CS: 39
CS: 68
Ascend Monolithic
Flex: 102
Flex: 131
ASES: 41
ASES: 84
ER: 26
ER: 39
Schnetzke (2017) [24]
29
25 (20–35)
Abd: 80 ± 43
Abd: 141 ± 34
CS: 4.5 ± 3.1
CS: 13.3 ± 2.2
CS: 25 ± 12
CS: 70 ± 14
Ascend Flex
Flex: 90 ± 39
Flex: 139 ± 37
CS%: 34 ± 16
CS%: 94 ± 18
ER: 9 ± 20
ER: 46 ± 20
SSV: 39 ± 18
SSV: 84 ± 16
Morwood (2017) [15]
34
30 (24–50)
Flex: 113
Flex: 149
VAS: 5.4
VAS: 1.1
ASES: 39
ASES: 83
Ascend Monolithic
ER: 30
ER: 57
Morwood (2017) [15]
34
24 (24–48)
Flex: 113
Flex: 155
VAS: 5.4
VAS: 0.4
ASES: 39
ASES: 94
Ascend Flex
ER: 30
ER: 55
Szerlip (2018) [29]
118
36 (24–60)
Abd: 75 ± 37
Abd: 160 ± 20
CS: 4 ± 3
CS: 13 ± 3
CS: 25 ± 15
CS: 80 ± 15
Ascend Monolithic/Ascend Flex
Flex: 79 ± 37
Flex: 160 ± 19
CS%: 32 ± 19
CS%: 106 ± 20
ER: 7 ± 14
ER: 45 ± 14
ASES: 42 ± 18
ASES: 88 ± 16
Romeo (2018) [21]
Apex
64
25
Flex: 116
Flex: 148
VAS: 6
VAS: 2
ASES: 37
ASES: 80
ER: 30
ER: 57
SST: 4
SST: 10
Denard (2018) [8]
42
35 (24–46)
Flex: 103 ± 28
Flex: 148
VAS: 6.9 ± 1.8
VAS: 1.2 ± 2.2
ASES: 35 ± 15
ASES: 83 ± 20
Ascend Monolithic/Ascend Flex
ER: 21 ± 15
ER: 49 ± 22
SST: 4 ± 3
SST: 10 ± 3
Schnetzke (2018) [25]
67
64 (49–84)
Abd: 97 ± 33
Abd: 155 ± 19
CS: 4.5 ± 1.9
CS: 13.5 ± 2.1
CS: 29 ± 12
CS: 77 ± 10
Ascend Monolithic
Flex: 108 ± 32
Flex: 161 ± 12
CS%: 38 ± 15
CS%: 111 ± 15
ER: 15 ± 21
ER: 42 ± 17
SSV: 45 ± 14
SSV: 88 ± 13
Schnetzke (2018) [26]
65
37 (24–58)
Flex: 100 ± 21
Flex: 159 ± 19
CS: 5 ± 1
CS: 13 ± 2
CS: 36 ± 8
CS: 75 ± 12
Ascend Flex
ER: 3 ± 11
ER: 43 ± 18
CS%: 50 ± 11
CS%: 102 ± 16
SSV: 85 ± 15
Weighted means
28
Abd: 82
Abd: 147
VAS: 6.0
VAS: 1.3
CS: 31
CS: 77
Flex: 99
Flex: 151
CS: 4.4
CS: 13.2
CS%: 38
CS%: 105
ER: 18
ER: 49
ASES: 40
ASES: 82
Abd abduction, ASES American Shoulder and Elbow Surgeons shoulder score, CS Constant score, ER external rotation, Flex flexion, NR not reported, SD standard deviation, SST simple shoulder test, SSV subjective shoulder value, VAS visual analog scale
The range of motion was reported in all studies included; flexion improved significantly from 99 to 151° and external rotation from 18 to 49°. Abduction was measured in five studies and the average improvement was +65° (82°–147°).
Different outcome scores were used to assess global shoulder function: the CMS (five studies), age- and gender-adjusted CMS (CMS%; four studies), and the ASES (five studies) were used most often. The average CMS significantly improved from 31 to 77, the CMS% from 38 to 105%, and the ASES from 40 to 82. In the longitudinal study by Schnetzke et al., the CMS improved significantly to a mean of 76 points at the first follow-up after 2.6 years and remained stable, at a mean of 77 points, at the final follow-up after 5.3 years.

Radiographic results

Radiographic changes were reported in 646 shoulders (Table 4). All studies reported radiographic changes with a particular focus on humeral bone adaptations and the rate of humeral loosening. The description of the radiographic changes is inconsistent throughout the studies included. In 13 of 653 patients (2%), humeral stem loosening was observed leading to stem revision in nine patients, with one study reporting eight out of 73 patients with humeral stem loosening. Eight studies reported on the frequency of calcar resorption ranging from 3 to 71%. One study by Schnetzke et al. reported the radiographic results at two different time points, after 2.6 years and 5.3 years, and found that the overall rating of the shoulders considered to have high bone adaptation decreased from 42 to 37% at the final follow-up. Cortical bone narrowing and osteopenia in the region of the calcar decreased from 76 to 66% between the first and the second time point.
Table 4
Radiographic findings after anatomical total shoulder replacement with short humeral stems
Study/implant
No. of shoulders
Follow-up, months (range)
Humeral bone adaptations
Humeral loosening
Glenoid loosening
Jost (2011) [13]
49
29 (24–43)
Radiolucent lines: 11/49 (22%)
0/49
NR
Biomet Comprehensive
Casagrande (2016) [5]
69
28 (24–48)
Partial calcar osteolysis: 10/69 (14%)
7/69 (10%)
0/69 (1%)
Ascend Monolithic
Complete calcar osteolysis: 2/69 (2%)
1 stem loosening <24 monthsa
1 glenoid loosening <24 months
Radiolucency: 49/69 (71%)
Schnetzke (2017) [24]
19
25 (20–35)
Calcar resorption: 7/19 (37%)
0/19
0/19
Ascend Flex
High bone adaptations: 5/19 (26%)
Morwood (2017) [15]
34
30 (24–50)
Calcar lucency: 14/34 (41%)
1/34 (3%)
0/34
Ascend Monolithic
Morwood (2017) [15]
34
24 (24–48)
Calcar lucency: 5/34 (15%)
0/34
0/34
Ascend Flex
Szerlip (2018) [29]
85
42
Calcar resorption: 10/85 (12%)
0/85
NR
Ascend Monolithic
Radiolucent line: 7/85 (8%)
3 stem loosening <24 monthsa
Szerlip (2018) [29]
33
24
Calcar resorption: 1/33 (3%)
0/33
NR
Ascend Flex
Radiolucent line: 0/33
Romeo (2018) [21]
64
25
Partial calcar osteolysis: 16/64 (25%)
0/64
NR
Radiolucent lines: 25/64 (39%)
Apex
Condensation lines: 48/64 (73%)
Denard (2018) [8]
42
35 (24–46)
High bone adaptations: 26/42 (62%)
1/42 (2%)
1/42
Ascend Monolithic/Ascend Flex
Medial calcar osteolysis: 30/42 (71%)
Schnetzke (2018) [25, 26]
67
64 (49–84)
Calcar resorption: 44/67 (66%)
0/67
1/67
Ascend Monolithic
High bone adaptations: 25/67 (37%)
Raiss (2018) [18]
Ascend Flex
150
32 (24–48)
Calcar resorption: 58/150 (39%)
0/150
NR
High bone adaptations: 26/150 (17%)
NR not reported
aPatients with stem loosening in <24 months were excluded from the study

Risk factors for radiographic changes/humeral loosening

In three studies, risk factors for the development of radiographic changes were carefully analyzed. A high metaphyseal filling ratio (defined as quotient of the diameter of the prosthesis and the humerus at the level of the distal border of the humeral head) and a high diaphyseal filling ratio (defined as quotient of the diameter of the prosthesis and the humerus at the distal third of the stem) of the humeral short stem led to significantly higher rates of bone adaptions in the studies of Schnetzke et al. (p ≤ 0.007) and Raiss et al. (p ≤ 0.003). Lack of proximal porous coating was also identified as a risk factor for higher rates of calcar resorption. Having a short-stem prosthesis without proximal porous coating was associated with calcar resorption in 12–71% of cases. In short-stem prostheses with added porous coating, calcar resorption was noted in 3–39% of cases. Humeral loosening was observed in 13 shoulders, and all patients received a shoulder replacement with the AM prosthesis. Casagrande et al. reported high rates of humeral loosening in their study (8/73 patients with humeral loosening). A detailed analysis of this study revealed that the humeral loosening was related to an infection in five patients. Szerlip et al. reported three patients with aseptic humeral loosening occurring before the 24-month follow-up. All of these patients were female with osteoporotic bone. This finding was confirmed by Raiss et al., who observed that a cortical contact of the humeral stem, female gender, as well as patient age > 65 years and a cortical thickness of <6 mm were also associated with high bone adaptions (p < 0.024).

Complications and revisions

Complications and revision are reported for 578 patients in nine studies (Table 5). The weighted average complication rate was 6% (0–15%) and the weighted average revision rate was 4% (0–12%). The most frequent complications were aseptic humeral loosening (n = 9) and septic humeral loosening (n = 4) leading to nine humeral stem revisions. Humeral stem loosening was only observed in patients treated with the AM stem without proximal porous coating. Casagrande et al. reported the most frequent complication (15%) and revision rates (12%), and a high rate of infection was also reported (four stems with septic loosening). Excluding this study, the weighted average complication rate was 4% and the weighted average revision rate was 2%.
Table 5
Complications and revisions
Study/implant
Complications
Details of complications
Revisions
Details of revisions
Jost (2011) [13]
2/49 (4%)
SSC rupture (1)
1/49 (2%)
SSC repair (1)
Biomet Comprehensive
Pulmonary embolism (1)
Casagrande (2016) [5]
11/73 (15%)
Humeral loosening due to infection (4)
9/73 (12%)
Humeral stem revision (6)
Ascend Monolithic
Aseptic humeral loosening (4)
Glenoid revision (1)
Instability (1)
Instability (1)
Periprosthetic fracture (1)
Periprosthetic fracture (1)
Glenoid loosening
Schnetzke (2017) [24]
1/29 (3%)
Periprosthetic fracture (1)
1/29 (3%)
Plate osteosynthesis (1)
Ascend Flex
Morwood (2017) [15]
1/34 (3%)
Aseptic humeral loosening (1)
1/34 (3%)
Humeral stem revision (1)
Ascend Monolithic
Morwood (2017) [15]
0/34
0/34
Ascend Flex
Szerlip (2018) [29]
9/121 (7%)
Aseptic humeral loosening (3)
4/121 (2%)
Revision to long humeral stem (2)
Intraoperative fracture of the anterior cortex (2)
Ascend Monolithic/Ascend Flex
Intraoperative fracture of the lesser tuberosity (2)
Debridement (1)
Deep infection (1)
Revision to reverse TSA (1)
Traumatic posterior dislocation (1)
Romeo (2018) [21]
0/64
0/64
Apex
Denard (2018) [8]
3/42 (7%)
SSC insufficiency (1)
2/42 (5%)
SSC repair (1)
Ascend Monolithic/Ascend Flex
Secondary rotator cuff insufficiency (1)
Revision to reverse TSA (1)
Aseptic humeral loosening (1)
Schnetzke (2018) [25]
3/67 (4%)
Secondary rotator cuff insufficiency (2)
2/67 (3%)
Revision to reverse TSA (2)
Ascend Monolithic
Glenoid loosening (1)
Schnetzke (2018) [26]
3/65 (5%)
Transient neuropraxia of the radial nerve (1)
1/65 (2%)
Wound debridement (1)
Ascend Flex
Subjective instability (1)
Postoperative hematoma (1)
Weighted means
33/578 (6%)
21/578 (4%)
SSC subscapularis tendon, TSA total shoulder arthroplasty

Discussion

Standard long-stem humeral components are associated with complications, such as intraoperative fracture of the humerus, stress shielding, aseptic loosening, and periprosthetic fracture [1, 3]. This may result in massive bone loss, which requires complex revision surgery. The rationale of implants with metaphyseal fixation that are either stemless or have a short humeral stem is the facilitation of stem removal and preservation of bone in the event of revision surgery [11]. One other important aspect is the occurrence of stress shielding in long-stem humeral components, which is associated with aseptic loosening and bone loss in the longer term [16]. Metaphyseal fixed implants should minimize this phenomenon.
The effect of reducing stem length has been investigated for implants at other joints, including the distal ulna and hip [2, 20, 30]. Reduced stem lengths have been shown to closely mimic the intact state. In 2016, Razfar et al. performed a finite element analysis for shoulder arthroplasty with intact shoulders and three reconstructed (standard length, short, and stemless implants) finite element models and found that reducing stem length produced humeral stresses that more closely matched the intact stress distribution in proximal cortical bone [19].
Reduced stem lengths closely mimic the intact shoulder state
In 2016, Harmer et al. wrote a review of new humeral components in shoulder arthroplasty and considered whether “humeral components are getting shorter?” [11]. At that time, only one study by Jost et al. about the results of anatomic short-stem prostheses had been published [13]. Harmer et al. therefore concluded that there was a lack of knowledge in the literature regarding short-stem and stemless humeral components and, more importantly, that we do not know how or when these implants may fail. Since then, metaphyseal fixed implants have gained high acceptance by shoulder surgeons.
Clinical results of short-stem prostheses are encouraging and are comparable to the results with other third- and fourth-generation shoulder prostheses. However, the high rate of stem loosening (8/73 shoulders) in the study by Casagrande et al. has led to some uncertainty regarding the use of short-stem prostheses [5]. Szerlip et al. also reported on aseptic stem loosening in three patients within 1 year of surgery [29]. In both studies, the first generation of the Ascend prosthesis without proximal porous coating was used. Szerlip et al. mentioned that all three cases of aseptic stem loosening were elderly women with osteoporotic bone. In their study, Raiss et al. reported that female gender as well as patient age > 65 years and a cortical thickness of <6 mm were associated with high bone adaptions (p < 0.024). A detailed analysis of the eight cases of stem loosening in the study of Casagrande revealed that five patients had stem loosening due to infection. Moreover, the stems in both studies were implanted using the “press fit” technique, and so there was diaphyseal cortical contact of the stem. According to the analyses of Raiss et al. and Schnetzke et al., a high metaphyseal filling ratio and a high diaphyseal filling ratio of the humeral short stem lead to significantly higher rates of bone adaptions. Therefore, it can be concluded that: the smaller the stem, the lower the risk of high bone adaptations. In this context, it should be mentioned that radiographic changes around humeral components are to be interpreted with caution. Hudek et al. showed that, depending on the radiation scatter, radiolucency in stemless shoulder arthroplasty is associated with an imaging phenomenon with a high rate of misinterpretation [12].
Interventions on stem design have led to the second generation of short-stem prostheses with porous coating added at the proximal part of the stem. Our study includes 288 shoulders treated with the second generation of the Ascend prosthesis, and no humeral loosening was observed in the short-term follow-up.
The findings from both the current study and the literature can be summarized as five potential risk factors for humeral stem loosening: (unrecognized) chronic infection; press-fit implantation (high filling ratio); cortical contact of the stem; lack of ingrowth surface treatment in the metaphyseal part of the stem; and indications other than primary osteoarthritis (e. g., secondary osteoarthritis).
None of the studies reported on the feasibility of uncemented short stems. This might be because cemented stems were excluded from the analysis. According to the personal experiences of the senior authors (GW and ML) in performing shoulder arthroplasty with short stems over the past 8 years, the percentage of stems that had to be cemented for better primary stability in primary osteoarthritis is low (<1%). Cementing of the stem is more likely (about 10%) for posttraumatic cases or for osteopenic metaphysis in cuff tear arthropathy, where primary stability cannot necessarily be assumed owing to the poor quality of bone.

Limitations

As with any systematic review and meta-analysis, the overall analysis is no better than the methodology and biases of the included studies. Owing to the low levels of evidence of the included studies, the small number of patients, and only short- to mid-term follow-up periods, the theoretically superior results of the shorterstem design have not been shown, yet. The current literature is subject to potential biases, including different follow-up lengths, different numbers and types of patients, and selective reporting [4]. With smaller case series, there is also the potential for bias based on single surgeon performance. Moreover, in eight out of the ten included studies, the results of the Ascend Monolithic/Ascend Flex prosthesis were reported, whereas only one study reported on the results of the Biomet Comprehensive Mini/Micro stem and the Apex™ shoulder prosthesis. Further studies including a higher number of patients with different types of short-stem prostheses and with longer follow-up are needed to show the superiority of shorter stems over standard-stem implants and to prove the theory of bone-sparing revision surgeries.

Practical conclusion

  • Anatomical total shoulder arthroplasty using a short-stem humeral component results in good clinical outcomes comparable to third- and fourth-generation shoulder arthroplasty.
  • In patients with poor bone quality, there might be some limitations in using a short-stem shoulder prosthesis.
  • If diaphyseal press-fit fixation of the humeral short stem is necessary to achieve stability, a longer stem or a cemented short stem may be favorable to avoid loosening of the humeral stem in the longer term.

Compliance with ethical guidelines

Conflict of interest

M. Loew, P. Raiss, and G. Walch received royalties from Wright/Tornier Inc., which is related to the subject of this work. No company had any input into the review, data analysis, or manuscript preparation. M. Schnetzke, his immediate family, and any research foundations with which he is affiliated have not received any financial payments or other benefits from any commercial entity related to the subject of this article.
This article does not contain any studies on human or animal subjects.
Open Access. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

Obere Extremität

Print-Titel

Spezialisierung auf die obere Extremität im orthopädisch-traumatologischen Bereich und Themenschwerpunkte mit klaren Handlungsempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Weitere Produktempfehlungen anzeigen
Literatur
1.
Zurück zum Zitat Aldinger PR, Raiss P, Rickert M et al (2010) Complications in shoulder arthroplasty: an analysis of 485 cases. Int Orthop 34:517–524CrossRef Aldinger PR, Raiss P, Rickert M et al (2010) Complications in shoulder arthroplasty: an analysis of 485 cases. Int Orthop 34:517–524CrossRef
2.
Zurück zum Zitat Austman RL, King GJ, Dunning CE (2011) Bone stresses before and after insertion of two commercially available distal ulnar implants using finite element analysis. J Orthop Res 29:1418–1423CrossRef Austman RL, King GJ, Dunning CE (2011) Bone stresses before and after insertion of two commercially available distal ulnar implants using finite element analysis. J Orthop Res 29:1418–1423CrossRef
3.
Zurück zum Zitat Bohsali KI, Wirth MA, Rockwood CA Jr. (2006) Complications of total shoulder arthroplasty. J Bone Joint Surg Am 88:2279–2292PubMed Bohsali KI, Wirth MA, Rockwood CA Jr. (2006) Complications of total shoulder arthroplasty. J Bone Joint Surg Am 88:2279–2292PubMed
4.
Zurück zum Zitat Borgerson K (2009) Valuing evidence: bias and the evidence hierarchy of evidence-based medicine. Perspect Biol Med 52:218–233CrossRef Borgerson K (2009) Valuing evidence: bias and the evidence hierarchy of evidence-based medicine. Perspect Biol Med 52:218–233CrossRef
6.
Zurück zum Zitat Casier S, Middernacht B, Van Tongel A et al (2017) Revision of reversed shoulder arthroplasty. Obere Extremität 12:16–24CrossRef Casier S, Middernacht B, Van Tongel A et al (2017) Revision of reversed shoulder arthroplasty. Obere Extremität 12:16–24CrossRef
7.
Zurück zum Zitat Churchill RS, Athwal GS (2016) Stemless shoulder arthroplasty-current results and designs. Curr Rev Musculoskelet Med 9:10–16CrossRef Churchill RS, Athwal GS (2016) Stemless shoulder arthroplasty-current results and designs. Curr Rev Musculoskelet Med 9:10–16CrossRef
9.
Zurück zum Zitat Denard PJ, Noyes MP, Walker JB et al (2018) Radiographic changes differ between two different short press-fit humeral stem designs in total shoulder arthroplasty. J Shoulder Elb Surg 27:217–223CrossRef Denard PJ, Noyes MP, Walker JB et al (2018) Radiographic changes differ between two different short press-fit humeral stem designs in total shoulder arthroplasty. J Shoulder Elb Surg 27:217–223CrossRef
10.
Zurück zum Zitat Deshmukh AV, Koris M, Zurakowski D et al (2005) Total shoulder arthroplasty: long-term survivorship, functional outcome, and quality of life. J Shoulder Elb Surg 14:471–479CrossRef Deshmukh AV, Koris M, Zurakowski D et al (2005) Total shoulder arthroplasty: long-term survivorship, functional outcome, and quality of life. J Shoulder Elb Surg 14:471–479CrossRef
11.
Zurück zum Zitat Harmer L, Throckmorton T, Sperling JW (2016) Total shoulder arthroplasty: are the humeral components getting shorter? Curr Rev Musculoskelet Med 9:17–22CrossRef Harmer L, Throckmorton T, Sperling JW (2016) Total shoulder arthroplasty: are the humeral components getting shorter? Curr Rev Musculoskelet Med 9:17–22CrossRef
12.
Zurück zum Zitat Hudek R, Werner B, Abdelkawi AF et al (2017) Radiolucency in stemless shoulder arthroplasty is associated with an imaging phenomenon. J Orthop Res 35:2040–2050CrossRef Hudek R, Werner B, Abdelkawi AF et al (2017) Radiolucency in stemless shoulder arthroplasty is associated with an imaging phenomenon. J Orthop Res 35:2040–2050CrossRef
13.
Zurück zum Zitat Jost PW, Dines JS, Griffith MH et al (2011) Total shoulder arthroplasty utilizing mini-stem humeral components: technique and short-term results. HSS J 7:213–217CrossRef Jost PW, Dines JS, Griffith MH et al (2011) Total shoulder arthroplasty utilizing mini-stem humeral components: technique and short-term results. HSS J 7:213–217CrossRef
14.
Zurück zum Zitat Loew M (2013) Short stem shoulder prosthesis : concept and first results. Orthopäde 42:501–506CrossRef Loew M (2013) Short stem shoulder prosthesis : concept and first results. Orthopäde 42:501–506CrossRef
15.
Zurück zum Zitat Morwood MP, Johnston PS, Garrigues GE (2017) Proximal ingrowth coating decreases risk of loosening following uncemented shoulder arthroplasty using mini-stem humeral components and lesser tuberosity osteotomy. J Shoulder Elbow Surg 26:1246–1252CrossRef Morwood MP, Johnston PS, Garrigues GE (2017) Proximal ingrowth coating decreases risk of loosening following uncemented shoulder arthroplasty using mini-stem humeral components and lesser tuberosity osteotomy. J Shoulder Elbow Surg 26:1246–1252CrossRef
16.
Zurück zum Zitat Raiss P, Edwards TB, Deutsch A et al (2014) Radiographic changes around humeral components in shoulder arthroplasty. J Bone Joint Surg Am 96:e54CrossRef Raiss P, Edwards TB, Deutsch A et al (2014) Radiographic changes around humeral components in shoulder arthroplasty. J Bone Joint Surg Am 96:e54CrossRef
17.
Zurück zum Zitat Raiss P, Schmitt M, Bruckner T et al (2012) Results of cemented total shoulder replacement with a minimum follow-up of ten years. J Bone Joint Surg Am 94:e1711–e1710CrossRef Raiss P, Schmitt M, Bruckner T et al (2012) Results of cemented total shoulder replacement with a minimum follow-up of ten years. J Bone Joint Surg Am 94:e1711–e1710CrossRef
19.
Zurück zum Zitat Razfar N, Reeves JM, Langohr DG et al (2016) Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis. J Shoulder Elbow Surg 25:1076–1083CrossRef Razfar N, Reeves JM, Langohr DG et al (2016) Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis. J Shoulder Elbow Surg 25:1076–1083CrossRef
20.
Zurück zum Zitat Reimeringer M, Nuno N, Desmarais-Trepanier C et al (2013) The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis. Comput Methods Biomech Biomed Engin 16:1221–1231CrossRef Reimeringer M, Nuno N, Desmarais-Trepanier C et al (2013) The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis. Comput Methods Biomech Biomed Engin 16:1221–1231CrossRef
21.
Zurück zum Zitat Romeo AA, Thorsness RJ, Sumner SA et al (2018) Short-term clinical outcome of an anatomic short-stem humeral component in total shoulder arthroplasty. J Shoulder Elbow Surg 27:70–74CrossRef Romeo AA, Thorsness RJ, Sumner SA et al (2018) Short-term clinical outcome of an anatomic short-stem humeral component in total shoulder arthroplasty. J Shoulder Elbow Surg 27:70–74CrossRef
22.
Zurück zum Zitat Schnetzke M, Coda S, Raiss P et al (2016) Radiologic bone adaptations on a cementless short-stem shoulder prosthesis. J Shoulder Elbow Surg 25:650–657CrossRef Schnetzke M, Coda S, Raiss P et al (2016) Radiologic bone adaptations on a cementless short-stem shoulder prosthesis. J Shoulder Elbow Surg 25:650–657CrossRef
23.
Zurück zum Zitat Schnetzke M, Coda S, Walch G et al (2015) Clinical and radiological results of a cementless short stem shoulder prosthesis at minimum follow-up of two years. Int Orthop 39:1351–1357CrossRef Schnetzke M, Coda S, Walch G et al (2015) Clinical and radiological results of a cementless short stem shoulder prosthesis at minimum follow-up of two years. Int Orthop 39:1351–1357CrossRef
24.
Zurück zum Zitat Schnetzke M, Preis A, Coda S et al (2017) Anatomical and reverse shoulder replacement with a convertible, uncemented short-stem shoulder prosthesis: first clinical and radiological results. Arch Orthop Trauma Surg 137:679–684CrossRef Schnetzke M, Preis A, Coda S et al (2017) Anatomical and reverse shoulder replacement with a convertible, uncemented short-stem shoulder prosthesis: first clinical and radiological results. Arch Orthop Trauma Surg 137:679–684CrossRef
25.
Zurück zum Zitat Schnetzke M, Rick S, Raiss P et al (2018) Mid-term results of anatomical total shoulder arthroplasty for primary osteoarthritis using a short-stemmed cementless humeral component. Bone Joint J 100-b:603–609CrossRef Schnetzke M, Rick S, Raiss P et al (2018) Mid-term results of anatomical total shoulder arthroplasty for primary osteoarthritis using a short-stemmed cementless humeral component. Bone Joint J 100-b:603–609CrossRef
27.
Zurück zum Zitat Seybold D, Geßmann J, Königshausen M et al (2016) Glenoidale und humerale Revision nach Schulterendoprothese. Obere Extremität 11:210–217CrossRef Seybold D, Geßmann J, Königshausen M et al (2016) Glenoidale und humerale Revision nach Schulterendoprothese. Obere Extremität 11:210–217CrossRef
28.
Zurück zum Zitat Stewart MP, Kelly IG (1997) Total shoulder replacement in rheumatoid disease: 7‑ to 13-year follow-up of 37 joints. J Bone Joint Surg Br 79:68–72CrossRef Stewart MP, Kelly IG (1997) Total shoulder replacement in rheumatoid disease: 7‑ to 13-year follow-up of 37 joints. J Bone Joint Surg Br 79:68–72CrossRef
29.
Zurück zum Zitat Szerlip BW, Morris BJ, Laughlin MS et al (2018) Clinical and radiographic outcomes after total shoulder arthroplasty with an anatomic press-fit short stem. J Shoulder Elb Surg 27:10–16CrossRef Szerlip BW, Morris BJ, Laughlin MS et al (2018) Clinical and radiographic outcomes after total shoulder arthroplasty with an anatomic press-fit short stem. J Shoulder Elb Surg 27:10–16CrossRef
30.
Zurück zum Zitat Van Rietbergen B, Huiskes R (2001) Load transfer and stress shielding of the hydroxyapatite-ABG hip: a study of stem length and proximal fixation. J Arthroplasty 16:55–63CrossRef Van Rietbergen B, Huiskes R (2001) Load transfer and stress shielding of the hydroxyapatite-ABG hip: a study of stem length and proximal fixation. J Arthroplasty 16:55–63CrossRef
31.
Zurück zum Zitat Verborgt O, El-Abiad R, Gazielly DF (2007) Long-term results of uncemented humeral components in shoulder arthroplasty. J Shoulder Elbow Surg 16:13–18CrossRef Verborgt O, El-Abiad R, Gazielly DF (2007) Long-term results of uncemented humeral components in shoulder arthroplasty. J Shoulder Elbow Surg 16:13–18CrossRef
Metadaten
Titel
Short-stem anatomical shoulder replacement—a systematic review
verfasst von
Marc Schnetzke, MD
Markus Loew
Patric Raiss
Gilles Walch
Publikationsdatum
04.04.2019
Verlag
Springer Medizin
Erschienen in
Obere Extremität / Ausgabe 2/2019
Print ISSN: 1862-6599
Elektronische ISSN: 1862-6602
DOI
https://doi.org/10.1007/s11678-019-0514-4

Weitere Artikel der Ausgabe 2/2019

Obere Extremität 2/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.