Skip to main content
Erschienen in: European Orthopaedics and Traumatology 4/2015

01.12.2015 | Original Article

Simple articular extension did not affect the excellent results of MIPO in treating distal tibia fractures after 5 years

verfasst von: Mohamed Ali, Ahmed Saleh, Ahmed Omar, Hesham Ali, Ezzat Fouly, Aasem Mohamed, Khaled Omran, Ahmed Mohamed Ahmed

Erschienen in: European Orthopaedics and Traumatology | Ausgabe 4/2015

Einloggen, um Zugang zu erhalten

Abstract

Background

Minimally invasive plate osteosynthesis (MIPO) becomes popular for treating distal tibia fractures. Intra-articular extension was accused for result deterioration and was considered as an indication for open reduction and internal fixation (ORIF). Our hypothesis was that the simple intra-articular extension can be successfully treated percutaneously, MIPO can be successfully applied, and ORIF is not mandatory. We wanted to determine whether the presence of simple articular extension would change the reported excellent results of MIPO after 5 years follow-up.

Patients and methods

As extensive articular affection has different treatment strategies, the inclusion criteria for this prospective clinical series included distal tibia fractures with only simple intra-articular extension (AO/OTA 43-B1, B2, C1, and C2). From 43 patients we treated with MIPO using the AO medial distal tibia anatomical locked plate, 13 patients were excluded as they did not complete the follow-up, and only 30 patients were reported. Only seven fractures were open. The minimum follow-up period was 5 years. The outcome measurements included fracture healing, alignment, nonunion, infection, ankle range of motion (ROM), implant removal, ankle osteoarthritis (OA), unemployment, failure to return to daily activities or sports, and functional assessment as per the American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale.

Results

All the fractures united, but with delay in two patients. No articular step-off more than 2 mm could be detected in any patient. At the metaphysis, three patients (10 %) had angular deformities less than 5°, uni-planar in two patients and bi-planar in one patient. Three patients (10 %) developed a superficial infection. These three patients had their implants removed and had reduced ankle ROM. Twenty-eight patients (93.33) returned to their original job. Twenty-four patients (80 %) had returned to their pre-injury daily activity and sports. At the end of follow-up, no patient developed ankle osteoarthritis or had deterioration of his earlier satisfactory clinical and functional results. The mean AOFAS score was 90.8 ± 6 at the end of follow-up.

Conclusions

After 5 years follow-up, MIPO was an excellent option for the challenging distal tibia fractures even with simple articular extension. With absence of OA, high percentage of the patients could keep excellent functional results, job, and activity.
Literatur
1.
Zurück zum Zitat Ronga M, Longo UG, Maffulli N (2010) Minimally invasive locked plating of distal tibia fractures is safe and effective. Clin Orthop Relat Res 468(4):975–982PubMedCentralCrossRefPubMed Ronga M, Longo UG, Maffulli N (2010) Minimally invasive locked plating of distal tibia fractures is safe and effective. Clin Orthop Relat Res 468(4):975–982PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Nork SE, Schwartz AK, Agel J, Holt SK, Schrick JL, Winquist RA (2005) Intramedullary nailing of distal metaphyseal tibial fractures. J Bone Joint Surg Am 87:1213–1221CrossRefPubMed Nork SE, Schwartz AK, Agel J, Holt SK, Schrick JL, Winquist RA (2005) Intramedullary nailing of distal metaphyseal tibial fractures. J Bone Joint Surg Am 87:1213–1221CrossRefPubMed
3.
Zurück zum Zitat Janssen KW, Biert J, Kampen A (2007) Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 31:709–714PubMedCentralCrossRefPubMed Janssen KW, Biert J, Kampen A (2007) Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 31:709–714PubMedCentralCrossRefPubMed
4.
Zurück zum Zitat Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg (Br) 84:1093–1110CrossRef Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg (Br) 84:1093–1110CrossRef
5.
Zurück zum Zitat Anglen JO (1999) Early outcome of hybrid external fixation for fracture of the distal tibia. J Orthop Trauma 13:92–97CrossRefPubMed Anglen JO (1999) Early outcome of hybrid external fixation for fracture of the distal tibia. J Orthop Trauma 13:92–97CrossRefPubMed
7.
Zurück zum Zitat Krackhardt T, Dilger J, Flesch I, Höntzsch D, Eingartner C, Weise K (2005) Fractures of the distal tibia treated with closed reduction and minimally invasive plating. Arch Orthop Trauma Surg 125:87–94CrossRefPubMed Krackhardt T, Dilger J, Flesch I, Höntzsch D, Eingartner C, Weise K (2005) Fractures of the distal tibia treated with closed reduction and minimally invasive plating. Arch Orthop Trauma Surg 125:87–94CrossRefPubMed
8.
Zurück zum Zitat Gupta RK, Rohilla RK, Sangwan K et al (2010) Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients. Int Orthop 34(8):1285–1290PubMedCentralCrossRefPubMed Gupta RK, Rohilla RK, Sangwan K et al (2010) Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients. Int Orthop 34(8):1285–1290PubMedCentralCrossRefPubMed
9.
Zurück zum Zitat Im GI, Tae SK (2005) Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation. J Trauma 59:1219–1223CrossRefPubMed Im GI, Tae SK (2005) Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation. J Trauma 59:1219–1223CrossRefPubMed
10.
Zurück zum Zitat Milner SA (1997) A more accurate method of measurement of angulation after fractures of the tibia. J Bone Joint Surg (Br) 79:972–974CrossRef Milner SA (1997) A more accurate method of measurement of angulation after fractures of the tibia. J Bone Joint Surg (Br) 79:972–974CrossRef
11.
Zurück zum Zitat Kitaoka HB, Alexander IJ, Adelaar RS, Nunley JA, Myerson MS, Sanders M (1994) Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot Ankle Int 15:349–353CrossRefPubMed Kitaoka HB, Alexander IJ, Adelaar RS, Nunley JA, Myerson MS, Sanders M (1994) Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot Ankle Int 15:349–353CrossRefPubMed
12.
Zurück zum Zitat Zelle BA, Bhandari M, Espiritu M, Koval KJ, Zlowodzki M (2006) Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 20:76–79CrossRefPubMed Zelle BA, Bhandari M, Espiritu M, Koval KJ, Zlowodzki M (2006) Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 20:76–79CrossRefPubMed
13.
Zurück zum Zitat Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H (1999) Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaveric injection study. Injury 28:A7–A12CrossRef Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H (1999) Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaveric injection study. Injury 28:A7–A12CrossRef
14.
Zurück zum Zitat Ghera S, Santori FS, Calderaro M, Giorgini TL (2004) Minimally invasive plate osteosynthesis in distal tibial fractures: pitfalls and surgical guidelines. Orthopedics 27(9):903–906PubMed Ghera S, Santori FS, Calderaro M, Giorgini TL (2004) Minimally invasive plate osteosynthesis in distal tibial fractures: pitfalls and surgical guidelines. Orthopedics 27(9):903–906PubMed
15.
Zurück zum Zitat Collinge C, Kuper M, Larson K, Protzman R (2007) Minimally invasive plating of high-energy metaphyseal distal tibia fractures. J Orthop Trauma 21:355–361CrossRefPubMed Collinge C, Kuper M, Larson K, Protzman R (2007) Minimally invasive plating of high-energy metaphyseal distal tibia fractures. J Orthop Trauma 21:355–361CrossRefPubMed
16.
Zurück zum Zitat Bahari S, Lenehan B, Khan H, McElwain JP (2007) Minimally invasive percutaneous plate fixation of distal tibia fractures. Acta Orthop Belg 73:635–640PubMed Bahari S, Lenehan B, Khan H, McElwain JP (2007) Minimally invasive percutaneous plate fixation of distal tibia fractures. Acta Orthop Belg 73:635–640PubMed
17.
Zurück zum Zitat Hazarika S, Chakravarthy J, Cooper J (2006) Minimally invasive locking plate osteo-synthesis for fractures of the distal tibia: results in 20 patients. Injury 37:877–887CrossRefPubMed Hazarika S, Chakravarthy J, Cooper J (2006) Minimally invasive locking plate osteo-synthesis for fractures of the distal tibia: results in 20 patients. Injury 37:877–887CrossRefPubMed
18.
Zurück zum Zitat Leonard M, Magill P, Khayyat G (2009) Minimally-invasive treatment of high velocity intraarticular fractures of the distal tibia. Int Orthop 33(4):1149–1153PubMedCentralCrossRefPubMed Leonard M, Magill P, Khayyat G (2009) Minimally-invasive treatment of high velocity intraarticular fractures of the distal tibia. Int Orthop 33(4):1149–1153PubMedCentralCrossRefPubMed
19.
Zurück zum Zitat Collinge C, Sanders R, DiPasquale T (2000) Treatment of complex tibial periarticular fractures using percutaneous techniques. Clin Orthop Relat Res 375:69–77CrossRefPubMed Collinge C, Sanders R, DiPasquale T (2000) Treatment of complex tibial periarticular fractures using percutaneous techniques. Clin Orthop Relat Res 375:69–77CrossRefPubMed
20.
Zurück zum Zitat Redfern DJ, Syed SU, Davies SJ (2004) Fractures of the distal tibia: minimally invasive plate osteosynthesis. Injury 35(6):615–620CrossRefPubMed Redfern DJ, Syed SU, Davies SJ (2004) Fractures of the distal tibia: minimally invasive plate osteosynthesis. Injury 35(6):615–620CrossRefPubMed
Metadaten
Titel
Simple articular extension did not affect the excellent results of MIPO in treating distal tibia fractures after 5 years
verfasst von
Mohamed Ali
Ahmed Saleh
Ahmed Omar
Hesham Ali
Ezzat Fouly
Aasem Mohamed
Khaled Omran
Ahmed Mohamed Ahmed
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Orthopaedics and Traumatology / Ausgabe 4/2015
Print ISSN: 1867-4569
Elektronische ISSN: 1867-4577
DOI
https://doi.org/10.1007/s12570-015-0320-4

Weitere Artikel der Ausgabe 4/2015

European Orthopaedics and Traumatology 4/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.