T1 mapping for myocardial extracellular volume measurement by cardiovascular magnetic resonance: bolus only vs primed infusion technique
verfasst von:
Steven K White, Daniel Sado, Marianna Fontana, Sanjay M Banypersad, Viviana Maestrini, Stefan K Piechnik, Matthew D Robson, Derek J Hausenloy, Amir M Sheikh, Philip N Hawkins, James Moon
Myocardial ECV can be measured using T1 mapping before and after contrast if the contrast agent distribution between blood:myocardial is at equilibrium. Equilibrium distribution can be achieved with a primed contrast infusion (EQ-CMR), or may be approximated by the dynamic equilibration achieved by delayed post bolus measurement. This bolus only approach is highly attractive but currently limited data support its use. We compared the bolus only technique with two gold standards: collagen volume fraction (CVF) from myocardial biopsy in aortic stenosis (AS), and the infusion technique in five representative conditions.
Methods
147 subjects were studied: healthy volunteers (n=50); hypertrophic cardiomyopathy (HCM, n=25); severe AS (n=22); amyloid (n=20); and chronic myocardial infarction (n=30). Bolus only (at 15 minutes) and infusion ECV measurements were performed and compared. In 18 subjects with severe AS the results were compared to histological CVF.
Anzeige
Results
ECV by bolus only technique correlated well with CVF (n=18, r2=0.56, p=<0.01) but the r2 was higher with the infusion technique (r2=0.71, p=<0.01). Across health and disease, there was high correlation between the techniques (r2=0.97). However, in diseases of high ECV (amyloid, HCM LGE, and infarction), Bland-Altman analysis indicates the bolus only technique consistently and increasingly overestimates ECV.
Conclusions
Bolus only, T1 mapping derived ECV measurement is sufficient for ECV measurement across a range of cardiac diseases and this approach is histologically validated in AS. However, when ECV is above 0.4, there is overestimation compared to the infusion approach.
Funding
British Heart Foundation.
×
×
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
T1 mapping for myocardial extracellular volume measurement by cardiovascular magnetic resonance: bolus only vs primed infusion technique
verfasst von
Steven K White Daniel Sado Marianna Fontana Sanjay M Banypersad Viviana Maestrini Stefan K Piechnik Matthew D Robson Derek J Hausenloy Amir M Sheikh Philip N Hawkins James Moon
Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.
Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.
Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.
In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.
Update Radiologie
Bestellen Sie unseren Fach-Newsletterund bleiben Sie gut informiert.