Skip to main content
Erschienen in: Acta Neurochirurgica 10/2017

04.05.2017 | Original Article - Neurosurgical Techniques

Target location after deep cerebral biopsies using low-volume air injection in 75 patients. Results and technical note

verfasst von: Maria A. Poca, Francisco-Ramon Martínez-Ricarte, Dario F. Gándara, Pilar Coscojuela, Elena Martínez-Sáez, Juan Sahuquillo

Erschienen in: Acta Neurochirurgica | Ausgabe 10/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

Stereotactic biopsy is a minimally invasive technique that allows brain tissue samples to be obtained with low risk. Classically, different techniques have been used to identify the biopsy site after surgery.

Objective

To describe a technique to identify the precise location of the target in the postoperative CT scan using the injection of a low volume of air into the biopsy cannula.

Methods

Seventy-five biopsies were performed in 65 adults and 10 children (40 males and 35 females, median age 51 years). Frame-based biopsy was performed in 46 patients, while frameless biopsy was performed in the remaining 29 patients. In both systems, after brain specimens had been collected and with the biopsy needle tip in the center of the target, a small volume of air (median 0.7 cm3) was injected into the site.

Results

A follow-up CT scan was performed in all patients. Intracranial air in the selected target was present in 69 patients (92%). No air was observed in two patients (air volume administered in these 2 cases was below 0.7 cm3), while in the remaining four patients blood content was observed in the target. The diagnostic yield in this series was 97.3%. No complications were found to be associated with intracranial air injection in any of the 75 patients who underwent this procedure.

Conclusions

The air-injection maneuver proposed for use in stereotactic biopsies of intracranial mass lesions is a safe and reliable technique that allows the exact biopsy site to be located without any related complications.
Literatur
1.
Zurück zum Zitat Balasubrammaniam V, Kanaka TS, Ramanujam PB (1974) Stereotaxic surgery for cerebral palsy. J Neurosurg 40:577–582CrossRefPubMed Balasubrammaniam V, Kanaka TS, Ramanujam PB (1974) Stereotaxic surgery for cerebral palsy. J Neurosurg 40:577–582CrossRefPubMed
2.
Zurück zum Zitat Dammers R, Haitsma IK, Schouten JW, Kros JM, Avezaat CJ, Vincent AJ (2008) Safety and efficacy of frameless and frame-based intracranial biopsy techniques. Acta Neurochir 150:23–29CrossRefPubMed Dammers R, Haitsma IK, Schouten JW, Kros JM, Avezaat CJ, Vincent AJ (2008) Safety and efficacy of frameless and frame-based intracranial biopsy techniques. Acta Neurochir 150:23–29CrossRefPubMed
3.
Zurück zum Zitat Dammers R, Schouten JW, Haitsma IK, Vincent AJ, Kros JM, Dirven CM (2010) Towards improving the safety and diagnostic yield of stereotactic biopsy in a single centre. Acta Neurochir 152:1915–1921CrossRefPubMedPubMedCentral Dammers R, Schouten JW, Haitsma IK, Vincent AJ, Kros JM, Dirven CM (2010) Towards improving the safety and diagnostic yield of stereotactic biopsy in a single centre. Acta Neurochir 152:1915–1921CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Field M, Witham TF, Flickinger JC, Kondziolka D, Lunsford LD (2001) Comprehensive assessment of hemorrhage risks and outcomes after stereotactic brain biopsy. J Neurosurg 94:545–551CrossRefPubMed Field M, Witham TF, Flickinger JC, Kondziolka D, Lunsford LD (2001) Comprehensive assessment of hemorrhage risks and outcomes after stereotactic brain biopsy. J Neurosurg 94:545–551CrossRefPubMed
5.
Zurück zum Zitat Furlanetti LL, Monaco BA, Cordeiro JG, Lopez WO, Trippel M (2015) Frame-based stereotactic neurosurgery in children under the age of seven: Freiburg University’s experience from 99 consecutive cases. Clin Neurol Neurosurg 130:42–47CrossRefPubMed Furlanetti LL, Monaco BA, Cordeiro JG, Lopez WO, Trippel M (2015) Frame-based stereotactic neurosurgery in children under the age of seven: Freiburg University’s experience from 99 consecutive cases. Clin Neurol Neurosurg 130:42–47CrossRefPubMed
6.
Zurück zum Zitat Hlastala MP, Van Liew HD (1975) Absorption of in vivo inert gas bubbles. Respir Physiol 24:147–158CrossRefPubMed Hlastala MP, Van Liew HD (1975) Absorption of in vivo inert gas bubbles. Respir Physiol 24:147–158CrossRefPubMed
7.
Zurück zum Zitat Kulkarni AV, Guha A, Lozano A, Bernstein M (1998) Incidence of silent hemorrhage and delayed deterioration after stereotactic brain biopsy. J Neurosurg 89:31–35CrossRefPubMed Kulkarni AV, Guha A, Lozano A, Bernstein M (1998) Incidence of silent hemorrhage and delayed deterioration after stereotactic brain biopsy. J Neurosurg 89:31–35CrossRefPubMed
8.
Zurück zum Zitat Livermore LJ, Ma R, Bojanic S, Pereira EA (2014) Yield and complications of frame-based and frameless stereotactic brain biopsy—the value of intra-operative histological analysis. Br J Neurosurg 28:637–644CrossRefPubMed Livermore LJ, Ma R, Bojanic S, Pereira EA (2014) Yield and complications of frame-based and frameless stereotactic brain biopsy—the value of intra-operative histological analysis. Br J Neurosurg 28:637–644CrossRefPubMed
9.
Zurück zum Zitat Lobao CA, Nogueira J, Souto AA, Oliveira JA (2009) Cerebral biopsy: comparison between frame-based stereotaxy and neuronavigation in an oncology center. Arq Neuropsiquiatr 67:876–881CrossRefPubMed Lobao CA, Nogueira J, Souto AA, Oliveira JA (2009) Cerebral biopsy: comparison between frame-based stereotaxy and neuronavigation in an oncology center. Arq Neuropsiquiatr 67:876–881CrossRefPubMed
10.
Zurück zum Zitat Mohyeldin A, Lonser RR, Elder JB (2016) Real-time magnetic resonance imaging-guided frameless stereotactic brain biopsy: technical note. J Neurosurg 124:1039–1046CrossRefPubMed Mohyeldin A, Lonser RR, Elder JB (2016) Real-time magnetic resonance imaging-guided frameless stereotactic brain biopsy: technical note. J Neurosurg 124:1039–1046CrossRefPubMed
11.
Zurück zum Zitat Skjoth-Rasmussen J, Jespersen B, Brennum J (2015) The use of Brainsuite iCT for frame-based stereotactic procedures. Acta Neurochir 157:1437–1440CrossRefPubMed Skjoth-Rasmussen J, Jespersen B, Brennum J (2015) The use of Brainsuite iCT for frame-based stereotactic procedures. Acta Neurochir 157:1437–1440CrossRefPubMed
12.
Zurück zum Zitat Soukup J, Zauner A, Doppenberg EM, Menzel M, Gilman C, Young HF, Bullock R (2002) The importance of brain temperature in patients after severe head injury: relationship to intracranial pressure, cerebral perfusion pressure, cerebral blood flow, and outcome. J Neurotrauma 19:559–571CrossRefPubMed Soukup J, Zauner A, Doppenberg EM, Menzel M, Gilman C, Young HF, Bullock R (2002) The importance of brain temperature in patients after severe head injury: relationship to intracranial pressure, cerebral perfusion pressure, cerebral blood flow, and outcome. J Neurotrauma 19:559–571CrossRefPubMed
13.
Zurück zum Zitat Woodworth GF, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD (2006) Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique. J Neurosurg 104:233–237CrossRefPubMed Woodworth GF, McGirt MJ, Samdani A, Garonzik I, Olivi A, Weingart JD (2006) Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique. J Neurosurg 104:233–237CrossRefPubMed
14.
Zurück zum Zitat Yuen J, Zhu CX, Chan DT, Ng RY, Nia W, Poon WS, Ng HK, Mok VC, Wong LK, Cheung TC, Siu DY (2014) A sequential comparison on the risk of haemorrhage with different sizes of biopsy needles for stereotactic brain biopsy. Stereotact Funct Neurosurg 92:160–169CrossRefPubMed Yuen J, Zhu CX, Chan DT, Ng RY, Nia W, Poon WS, Ng HK, Mok VC, Wong LK, Cheung TC, Siu DY (2014) A sequential comparison on the risk of haemorrhage with different sizes of biopsy needles for stereotactic brain biopsy. Stereotact Funct Neurosurg 92:160–169CrossRefPubMed
Metadaten
Titel
Target location after deep cerebral biopsies using low-volume air injection in 75 patients. Results and technical note
verfasst von
Maria A. Poca
Francisco-Ramon Martínez-Ricarte
Dario F. Gándara
Pilar Coscojuela
Elena Martínez-Sáez
Juan Sahuquillo
Publikationsdatum
04.05.2017
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 10/2017
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-017-3191-3

Weitere Artikel der Ausgabe 10/2017

Acta Neurochirurgica 10/2017 Zur Ausgabe

How I Do it - Neurosurgical Techniques

How I do it? Cranial setup for cranial settling

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.