Skip to main content
Erschienen in: Advances in Therapy 6/2014

Open Access 01.06.2014 | Original Research

The Clinical Impact of Different Coagulometers on Patient Outcomes

verfasst von: Jan Leendert Pouwel Brouwer, Hugo Stoevelaar, Christoph Sucker

Erschienen in: Advances in Therapy | Ausgabe 6/2014

Abstract

Introduction

Long-term anticoagulation therapy using vitamin K antagonists (VKA) is used in millions of patients worldwide to reduce the risk of thrombotic or thromboembolic events. Control and monitoring of VKA therapy is improved by the regular self-measurement of international normalized ratio (INR) using a home monitoring device. This retrospective analysis of a large cohort of patients in the Netherlands seeks to determine whether the choice of INR monitor could have a clinical impact on patient outcomes.

Methods

The National Thrombosis Service provides medical supervision, training and support to anticoagulant patients eligible for home-monitoring of INR in the Netherlands. Two INR monitors (CoaguChek XS and INRatio2) have been distributed at random to patients since June 2011, and patient self-testing data (INR measurements and other clinical parameters) have been recorded to measure and improve treatment outcomes. The data have been retrospectively analyzed to determine any effect of the choice of monitor. Univariate and multivariate statistical tests are used to assess any differences between groups in terms of efficacy and safety parameters.

Results

Data from 4,326 patients were collated, and 156,507 INR values were included in the analysis. Over half the patients (54.3%) were being treated for atrial fibrillation, and 77.6% were prescribed acenocoumarol. There were few differences between the patient populations using the two different monitors. Anticoagulant control overall was good, with high percentage of time (87.9%) in the appropriate INR range and low incidence of excessively high or low INR values (0.085/month). Minor clinical events related to safety were low (0.78 per patient-year) and showed few differences between monitors. Mortality rates were similar [hazard ratio (HR) 1.05, 95% confidence interval (CI) 0.65–1.70].

Conclusion

Self-testing data from a large cohort of patients in the Netherlands suggest that there is no clinically relevant effect of the choice of coagulation monitor (CoaguChek XS or INRatio2) on the time in therapeutic range (TTR), minor or fatal outcomes of long-term anticoagulation management.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1007/​s12325-014-0124-x) contains supplementary material, which is available to authorized users.

Introduction

Anticoagulation is a widespread therapeutic intervention as secondary prevention after various venous or arterial thrombotic or thromboembolic events, or as primary prophylaxis, especially of stroke or systemic embolism in patients with atrial fibrillation. More than 6 million people in Europe have atrial fibrillation [1], with prevalence estimated from 1–2% [1] to 2.9% or more in adults [2], and increasing with age. Long-term risk reduction of thrombotic or thromboembolic events can be achieved using vitamin K antagonists (VKA) and in Europe the most commonly used are acenocoumarol, phenprocoumon and warfarin. Treatment with these types of anticoagulants is very effective in reducing the risk of an ischemic stroke while maintaining a low risk of bleeding [3].
The effectiveness of anticoagulant therapy with VKA is however crucially dependent on maintenance of the coagulation status within a specific range. The international normalized ratio (INR) is the established and generally accepted method to guide treatment of patients on long-term anticoagulation treatment with VKA [1]. Time within INR therapeutic range >70% is associated with significantly improved outcomes [4]. Patients whose INR strays too far from the optimal level of anticoagulation are at increased risk of experiencing a hemorrhagic or thromboembolic event [5], with significantly higher incidence of thromboembolism [relative risk 4.5 for INR <2.0, 95% confidence interval (CI) 3.1–6.6, P < 0.001] or major bleeding (relative risk 6.4 for INR >5.0, 2.5–16.1, P < 0.001) compared with INR 2.0–3.0 [6].
Maintenance of INR within the therapeutic range with VKA is challenging for many patients. More frequent measurement of INR, which improves control of anticoagulant therapy, can be better achieved by the patient using a home-based INR monitoring device compared to outpatient visits to a laboratory or clinic [7, 8]. Two options of self-care are available to the patient: patient self-testing (PST), where the INR test is executed by the patient and the INR value is communicated with the patient’s clinic, which responds with a new dosage schedule; and patient self-management (PSM), where the patients are trained to monitor and interpret the INR themselves, and adjust the anticoagulant dose accordingly. Systematic reviews have shown PST and PSM to be superior to standard monitoring, with fewer thromboembolic events, decreased overall mortality and reduced bleeding events [7, 912]. PST/PSM is therefore recommended in anticoagulant guidelines for suitable patients [13, 14].
Effective PST or PSM requires not only able and motivated patients, a user-friendly, intelligent Electronic Patient Record and a suitable algorithm for management of dose adjustment, but also depends on reliable and accurate point of care testing devices. While the benefits of PST/PSM have been established, there has been no large scale comparison of the effect of different INR monitors on clinical outcomes. The current analysis seeks to address this question by retrospectively examining the large database of the National Thrombosis Service (NTS), TK Ede, the Netherlands, which records relevant parameters for patients’ measurements and clinical outcomes, allowing for identification of trends and correlations.
Time in therapeutic range (TTR) is widely accepted as a valid surrogate parameter for the clinical effectiveness and safety of VKA anticoagulant treatment [4, 1518]. The level of INR variation and the number of critical INR values (INR <1.5 or >5.0) have also been discussed as surrogate parameters specifically addressing the risk of adverse events [8, 19, 20]. The current analysis aims to observe the clinical impact of the different INR measurement devices on the coagulation control parameters as well as on the overall clinical outcomes.

Methods

Description of the NTS

The NTS was established in 2006 and has developed an extensive patient support service, comprised of e-learning, user-friendly, intelligent software, one-on-one instruction and education, 24/7 medical service desk, 6-weekly newsletters and various reminder services to optimally motivate, support and develop ‘good patientship’.
Potential users of NTS self-care establish contact with the NTS through the internet, and NTS staff follow up within 24 h through telephone contact. The goal is to make sure that the patients have purposefully made contact with the NTS and then to establish their eligibility for INR self-testing at home. Patient eligibility is based on the patient’s level of understanding, motivation to self-care, ability and willingness to perform the blood test itself and available technology (computer/mobile device with internet access), with no influence of age or disease severity. Eligible patients are then provided with access to and support for a number of e-learning modules about thrombosis, anticoagulation, INR measurement, the advantages and the responsibilities of self-care, the practical and technical implications of self-care and (voluntary) self-dosing. Those who pass a mandatory certification go on to execute a practice test, at home or at work, in the presence of a qualified NTS nurse, using the monitor to measure their INR and practising the use of the Electronic Patient Record. Patients who pass the practice test are accepted for self-testing by the NTS. Patients who express the interest to become fully self-managing will first gather 3 months of experience in the PST model before entering into the advanced program for PSM. Patients who do not meet the requirements will not be accepted; approximately 53% of all patients who make contact via the NTS website go on to home-monitor (33% drop out during first telephone contact, 10% are unwilling or unable to complete e-learning, 4% drop out during the intake process or the first 4 weeks). Of the patients on home-monitoring in this analysis, 80% were on PST and 20% were willing and able to perform PSM.
Patients then start to measure their INR and record the measurement result on the system, and answer questions regarding their clinical status. NTS staff access this information to check and (if relevant) respond to any mention of thrombotic or bleeding events, adverse effects, changes in concomitant medication and other events. Dose adjustments are provided or, in self-dosing patients, checked and approved or adapted as required. Frequency of testing depends on the level of INR stability, with the appropriate dosing schedule provided by NTS medical staff for PST patients, and determined by PSM patients themselves, supervised by medical staff. Further education, motivational support and––if necessary––reminders are provided on a regular basis. Round-the-clock medical support is also offered to NTS patients.
Minor clinical events are regularly self-reported by all patients at the time of the INR measurements. Deaths are required to be pro-actively reported to the Dutch healthcare authorities, and details of serious but non-fatal events may also be requested retrospectively by the authorities. Therefore the NTS captures and retains records of death and serious events that could potentially lead to death which could be related to the therapy, such as hemorrhages or strokes. This has been done in a structured, uniform way since February 2012. While the number of deaths can be reliably captured by the NTS, the actual event or reason for death cannot always be audited reliably. Similarly, serious non-fatal events are not independently audited. Only the verified data regarding number of deaths have therefore been included in this analysis.
The therapeutic ranges for INR in anticoagulation therapy with VKAs are individually set by the admitting physician, and follow the Federation of Dutch Thrombosis Services guidelines for INR ranges for different indications [21]. The guidelines specify a low (2.0–3.0) and high (2.5–3.5) intensity anticoagulant range, and recommend an additional 0.5 INR units be considered acceptable in order to avoid low INR values, leading to therapeutic ranges of 2.0–3.5 and 2.5–4.0. In comparison to ‘target range’ used as a standard term internationally, these correspond to INR ranges of 2.0–3.0 and 2.5–3.5. As the TTR is typically used in the Netherlands and the processes of the NTS are laid out accordingly, the TTR was primarily used in the subsequent analysis in this paper. The wider ranges mean that values reported here for TTR and number/proportion of values in therapeutic range are higher than those in many studies in the literature using target ranges 1 INR unit wide [22].
The use of two different point of care coagulometers (CoaguChek® XS, Roche Diagnostics, Basel, Switzerland; INRatio®2, Alere Inc., San Diego, USA) with identical protocols within the NTS system allows direct comparison of their impact on patient outcomes.

Statistical Analysis

All patients entering the NTS from June 2011 and fatal events starting 2012 onwards were included in the analysis. The reason for this start date was that from then onwards the NTS worked with both devices, CoaguChek XS and INRatio2. Monitors were distributed to patients based on device availability within the NTS purchasing system at the time, and with no consideration of patient characteristics except for those in residential care settings (~5%), where the choice was determined by the existing point of care monitors used by the care home.
The first 90 days after treatment start were excluded from the observation period to allow for familiarization with the system (consistent with the analytical approach used elsewhere [8, 23]), and to be able to assess any differences between devices during the more stable phase associated with better INR control after the first 3 months [23].
Main endpoints in the statistical analysis are TTR values. TTR values were computed by the Rosendaal method [24], using the predefined therapeutic range of INR values. In addition, the percentage of values inside the therapeutic range, and the frequency of critical values (INR <1.5 or INR >5.0) were included as endpoints. Further, critical values were analyzed as number of events observed per month. The occurrence of minor clinical events was self-reported by patients. Serious clinical events and deaths were captured and kept on record by the NTS, and mortality data are included in the analysis.
TTR values and the number of critical values per month were treated as interval scaled variables in subsequent analyses. Location differences between subgroups were tested using Wilcoxon’s ranksum test with adjustment for tied values. In case of more than two subgroups, this test was replaced by the Kruskal–Wallis ranksum test, also adjusted for ties.
Least squares multiple regression was used to explain the influence of the treatment (i.e. the device in use), demographic data and additional medical variables (indication, therapeutic range, medication) on TTR, with dichotomous and polytomous variables being transformed into groups of dummy indicator variables. For each group of indicator variables, the largest subgroup was used as reference group. Cox proportional hazard regression was used to assess the multivariate influence on the time to fatal events. The regression took account of repeated events per patient applying the Conditional Risk Set modelling technique proposed by Prentice et al. [25]. As standard, the computation of standard errors used the robust clustering technique proposed by Lin and Wei [26]. The simple effect of the device on the time between fatal events was determined graphically using the Kaplan–Meier curve and an associated logrank test.
Statistical analysis as conducted in STATA/SE v13.0 by StataCorp LP, College Station, USA (2013).
This article does not contain any new studies with human or animal subjects performed by any of the authors.

Results

Of the 5,108 patients enrolled in the NTS program from June 2011–February 2014, 2,210 used CoaguChek XS and 2,898 used INRatio2 as an INR home monitoring device. Out of these, 4,326 patients (85%) had INR measurements recorded in the database after the 90-day familiarization period and were included in the further analysis (1,961 CoaguChek XS and 2,365 INRatio2). For these patients a total of 217,369 valid INR measurements were available for analysis (104,295 CoaguChek XS and 113,074 INRatio2), of which 156,507 INR values (72%) were obtained after the 90-day familiarization period (79,418 CoaguChek XS and 77,089 INRatio2, reflecting the longer average observation period for patients using CoaguChek) and these were included in the further analysis.

Patient Characteristics

Table 1 shows a summary of patient characteristics. Males made up 67.6% of the patients, the majority of the patients were between 45 and 74 years of age, and the leading indication for anticoagulation was atrial fibrillation (54.3%) (Table 1). The predominant target range for the INR was 2.5–3.5 (77.9%), corresponding to a therapeutic range of 2.0–3.5, and most patients were managed using acenocoumarol (77.6%). Some patients were managed with phenprocoumon (22.2%) and only seven patients (0.2%) received warfarin. Due to the low number of patients on warfarin, subgroup analysis was not performed for this medication. The patients were observed for a median of 1.44 years, or 1.20 years after the 90-day familiarization period [interquartile range (IQR) 0.49–1.76]. Data were observed from patients using CoaguChek XS for slightly longer (median of 1.37 years with an IQR of 0.95–1.83) versus INRatio2 (median of 1.06 years, IQR 0.33–1.72). The difference in observation time has been corrected for in the subsequent analyses.
Table 1
Demographics and univariate analyses
Group
Number of patients
Patient distribution (%)
INR measurements per month
% values in therapeutic range
TTR
Critical values per month
All
4,326
100.0
2.809
83.9%
87.9%
0.085
Device used
P=
 
<0.0001
0.0113
0.0788
0.9746
 CoaguChek XS
1,961
45.3
2.698
84.6%
88.5%
0.084
 INRatio2
2,365
54.7
2.902
83.3%
87.4%
0.086
Gender
P=
 
<0.0001
<0.0001
<0.0001
0.0002
 Male
2,925
67.6
2.707
84.5%
88.4%
0.070
 Female
1,401
32.4
3.022
82.6%
86.7%
0.117
Age (years)
P=
 
0.0001
0.1613
0.2454
0.0188
 <45
363
8.4
2.849
82.9%
86.8%
0.096
 45–64
2,000
46.2
2.759
84.1%
87.9%
0.088
 65–74
1,363
31.5
2.773
84.4%
88.3%
0.071
 75–79
311
7.2
2.805
84.2%
87.9%
0.087
 80–84
182
4.2
3.217
82.2%
87.2%
0.123
 ≥85
107
2.5
3.394
79.9%
85.0%
0.104
Indication
P=
 
0.0564
0.0005
0.0139
0.0007
 AF, no MHV
2,303
53.2
2.777
84.5%
88.3%
0.076
 AF and MHV
47
1.1
2.878
78.8%
85.3%
0.136
 MHV, no AF
297
6.9
2.857
84.1%
88.3%
0.088
 DVT
728
16.8
2.750
84.4%
88.2%
0.084
 Other
951
22.0
2.915
82.2%
86.6%
0.104
Therapeutic range
P=
 
0.0001
0.0001
0.0001
0.0001
 2.0–3.5
3,368
77.9
2.766
84.7%
88.6%
0.073
 2.5–4.0
729
16.9
3.001
79.1%
84.4%
0.140
 Others
229
5.3
2.842
87.4%
88.3%
0.092
Medication
P=
 
<0.0001
<0.0001
<0.0001
<0.0001
 Acenocoumarol
3,359
77.6
2.831
82.9%
87.2%
0.087
 Phenprocoumon
960
22.2
2.739
87.4%
90.0%
0.078
 Others (warfarin)
7
0.2
    
Distribution of patients numbers, average INR measurements per month, share of measurements within therapeutic range, and TTR across devices used, gender, age, indication for anticoagulation, target therapeutic range, and medication used. Statistical significance of ANOVA for each group
AF atrial fibrillation, DVT deep vein thrombosis, INR international normalized ratio, MHV mechanical heart valves, TTR time in therapeutic range, defined in this setting to include an additional 0.5 INR units (e.g. therapeutic range 2.0–3.5 for an international target range of 2.0–3.0)

Overall Quality of INR Management

Overall, 83.9% of measured INR values were within therapeutic range, resulting in a time in therapeutic range of 87.9% (Table 1). For international reference, these values correspond to a time in target range of 68.9%, although therapy was not aimed at maintenance in this narrower range. Independent of the definition of the range, only 0.085 INR measurements per month (2.4% per patient) were classified as critical values (INR <1.5 or >5.0), from an overall average of 2.8 INR measurements per month, with no statistically significant difference between critical values per month for the two INR monitors (P = 0.97).

Univariate Analysis of Surrogate Markers

Taken together, gender, indication, the target range, and the choice of medication consistently impacted the different surrogate metrics, although the amount of the impact was small. In contrast, patient age and choice of INR monitor only showed a small and not statistically significant effect on the most important surrogate parameters of good INR control (TTR and critical values).
Comparing the effect on the TTR of the same set of patient characteristics across the two monitors using a univariate analysis, the overall difference in the effect of the two monitors was not statistically significant (P = 0.079) and only became statistically significant in defined subgroups (without a correction for multiple testing) (Table 2). However, some differences were observed in the patient distribution among the two monitors, with INRatio2 being used disproportionally more often in males, patients with an age of 45–74 years, patients with atrial fibrillation as a primary indication, patients with a target INR range of 2.5–3.5, and patients receiving phenprocoumon. To take these differences in distribution into account, a multivariate analysis was subsequently performed.
Table 2
Univariate comparison of the monitor used
Group
Difference: CoaguChek vs. INRatio2
Patient distribution (%)
TTR (%)
P
All
0.0
1.1
0.079
Gender
 Male
0.8
1.1
0.199
 Female
−0.8
1.2
0.199
Age (years)
 <45
−0.4
0.7
0.969
 45–64
5.2
1.5
0.157
 65–74
2.9
2.0
0.033
 75–79
−1.1
0.2
0.724
 80–84
−3.0
−2.0
0.451
 ≥85
−3.5
−3.1
0.714
Indication
 AF, no MHV
3.6
1.2
0.404
 AF and MHV
0.0
4.6
0.046
 MHV, no AF
−1.8
3.7
0.540
 DVT
−3.1
1.3
0.040
 Other
1.2
−0.3
0.252
Therapeutic range
 2.0–3.5
2.8
1.4
0.037
 2.5–4.0
−2.6
2.3
0.049
 Others
−0.2
−4.7
0.027
Medication
 Acenocoumarol
−3.5
1.4
0.005
 Phenprocoumon
3.6
0.8
0.514
 Others (warfarin)
−0.1
0.0
 
Univariate comparison of the effect of the coagulometer (P for TTR comparison using a ranksum test, without Bonferroni adjustment)
P values in bold are below the threshold for significance (0.05)
AF atrial fibrillation, DVT deep vein thrombosis, INR international normalized ratio, MHV mechanical heart valves, TTR time in therapeutic range, defined in this setting to include an additional 0.5 INR units (e.g. therapeutic range 2.0–3.5 for an international target range of 2.0–3.0)

Clinical Events

Self-reported minor clinical events (Table 3) were infrequently recorded by patients, with a total of 4,043 minor events being reported in the 5,185 patient-years observed. For CoaguChek XS 2,117 events were reported in 2,682 patient-years observed (average of 0.790 events per patient-year); for INRatio2 these figures were 1,926 events in 2,503 patient-years (average of 0.769 events per patient-year). The leading minor events were bruises (45%; 1,804 events) and nose bleeds (19%; 774 events), together accounting for more than half of the minor events, followed by conjunctival bleeds (11%) resulting in a reported impairment of vision (7%), blood in urine (6%), blood in stool (5%), black stool (3%), muscle bleeds and thromboembolism (2% each), and joint bleeds (1%; 39 events). The differences in frequencies of minor clinical events between the two monitors was not statistically significant for most minor clinical events in the univariate comparison. For hematuria and conjunctival bleeds, patients on CoaguChek XS experienced a statistically significant higher frequency of events than patients on INRatio2 (without correcting for multiple testing, Table 3), although the number of events was low for both groups.
Table 3
Clinical events
 
Total
CoaguChek XS
INRatio2
P
# events
% of total (%)
# events
% of total (%)
# events
% of total (%)
Bruises
1,804
45
951
45
853
44
0.211
Nose bleeds
774
19
387
18
387
20
0.239
Blood in urine
233
6
150
7
83
4
0.012
Blood in stool
215
5
101
5
114
6
0.783
Black stool
111
3
43
2
68
4
0.207
Muscle bleeds
96
2
46
2
50
3
0.607
Joint bleeds
39
1
12
1
27
1
0.130
Conjunctival bleeds
433
11
235
11
198
10
0.044
Impaired vision
266
7
161
8
105
5
0.149
Thromboembolism
72
2
31
1
41
2
0.169
All minor events
4,043
 
2,117
 
1,926
  
All fatal events
71
 
40
 
31
 
0.844
Observed minor and major clinical events, all observations. Statistical significance for the univariate differences of the mean events per time observed between the two monitors
P values in bold are below the threshold for significance (0.05)
Serious clinical events were even less frequent. In total, 71 fatal events were observed, of which 31 patients used INRatio2 and 40 used CoaguChek XS. The Kaplan–Meier survival estimate curves are shown in Fig. 1 demonstrating no difference between the groups using different monitors. The 1-year death rate was 1.9% for patients using INRatio2 and 2.1% for CoaguChek XS. The hazard ratio (HR) of 0.95 was not statistically significant in the univariate analysis, i.e., without correction for other influencing factors (P = 0.844, Table 3). Consequently, the Kaplan–Meier estimation showed mostly identical curves (Fig. 1). However, as the risk profile was different between these two populations, a multivariate analysis was subsequently performed for verification.

Multivariate Analysis for Surrogate Parameters

The multivariate analysis (Table 4), considering all patient characteristics, only had a small explanatory power of r 2 = 0.0419 for TTR and r 2 = 0.0258 for the critical value rate, although it was statistically significant (P < 0.0001 for both models).
Table 4
Multivariate analysis for TTR and critical values
Influencer
TTR
Critical INR values per month
Coefficient (%)
Std. error (%)
P
95% CI (%)
Coefficient
Std. error
P
95% CI
Device: INRatio2 vs. CoaguChek
−1.0
0.4
0.008
−1.7
−0.3
−0.002
0.007
0.826
−0.016
0.013
Gender: female vs. male
−1.9
0.4
<0.001
−2.6
−1.1
0.048
0.008
<0.001
0.033
0.063
Age at program start (years)
0.0
0.0
0.454
0.0
0.0
0.000
0.000
0.894
−0.001
0.001
Length of monitoring (log days)
0.6
0.2
0.001
0.2
0.9
−0.011
0.003
0.001
−0.018
−0.004
INR therapeutic range (vs. 2.0–3.5)
 2.5–4.0
−5.3
0.6
<0.001
−6.4
−4.1
0.082
0.011
<0.001
0.060
0.104
 Others
−0.8
0.8
0.312
−2.4
0.8
0.023
0.016
0.143
−0.008
0.055
Primary indication (vs. AF, no MHV)
 AF and MHV
−0.2
1.8
0.920
−3.7
3.3
0.015
0.035
0.661
−0.053
0.083
 MHV, no AF
3.0
0.8
<0.001
1.4
4.6
−0.037
0.016
0.022
−0.069
−0.005
 DVT
0.0
0.5
0.967
−1.1
1.0
−0.001
0.011
0.956
−0.021
0.020
 Others
0.1
0.5
0.820
−0.9
1.1
−0.005
0.010
0.593
−0.025
0.014
Phenprocoumon vs. acenocoumarol
3.1
0.4
<0.001
2.2
4.0
−0.015
0.009
0.092
−0.031
0.002
Constant
84.9
1.6
<0.001
81.7
88.2
0.127
<0.001
0.000
0.064
0.190
Multiple regression of patient characteristics on TTR (overall ANOVA P < 0.0001; r 2 = 0.0419) and critical values (overall ANOVA P < 0.0001; r 2 = 0.028)
P values in bold are below the threshold for significance (0.05)
AF atrial fibrillation, CI confidence interval, DVT deep vein thrombosis, INR international normalized ratio, MHV mechanical heart valves, TTR time in therapeutic range, defined in this setting to include an additional 0.5 INR units (e.g. therapeutic range 2.0–3.5 for an international target range of 2.0–3.0)
Correcting for all other patient characteristics, the use of CoaguChek XS had a positive effect of +1.0% on the TTR and 0.002 fewer critical values per month compared with the use of INRatio2. While the effect on TTR was smaller in magnitude than in the univariate analysis (Table 1), in the multivariate analysis it was statistically significant (P = 0.008). The effect of the coagulometer on the rate of critical values remained not statistically significant.
The effect of the choice of coagulometer on the TTR and critical value rate was smaller than the effect of female gender (−1.9% on TTR and +0.048 on critical values per month, both P < 0.001), and the choice of medication (phenprocoumon +3.1% on TTR and −0.015 critical values per month, both P < 0.001). A high target range (3.0–4.0) decreased the TTR significantly (−5.3%) and increased the critical events per month (+0.082, both P < 0.001). A primary indication for mechanical heart valves increased the TTR by 3.0% (P < 0.001) without a statistically significant effect on the frequency of critical values.

Multivariate Analysis for Fatal Events

The multivariate Cox regression analysis for the different parameters on patient survival showed that the choice of the device had no statistically significant influence (HR 1.05, 95% CI 0.65–1.70, P = 0.838) (Fig. 1). Similarly, most indications did not significantly influence the risk, while the target range and, most prominently, patient age at start, had statistically significant effects (a year higher age increased the HR by 8%, 95% CI 5–11%, P < 0.001) (Fig. 2).

Discussion

This retrospective analysis shows that the choice of coagulation monitor had no effect on clinical outcome of 4,326 Dutch patients treated with VKAs using self-monitoring. The results of the analysis provide a good insight to the quality of INR control in patients performing self-monitoring of INR values and, consequently, the clinical efficacy and safety of VKA treatment. In addition, the analysis provides unique data allowing us to compare the quality of INR control with two different INR monitors, INRatio2 and CoaguChek XS.
Since major clinical events and deaths could not be verifiably attributed to a particular cause in the NTS data, no analysis of the rate of individual major thrombotic or hemorrhagic events could be completed. Therefore, it is not possible to compare the overall rate in the NTS data with rates reported in studies of new oral anticoagulant agents (NOACs), nor is it an objective of this analysis. In addition, this analysis is based on data collected in clinical practice, and not in the pre-specified and more tightly defined setting of randomized controlled trials. The major NOAC studies in atrial fibrillation suggest a general non-inferiority of NOACs versus warfarin with a reduction of hemorrhagic events (most notably of cerebral bleeding [2730]). Interestingly some meta-analyses found in subgroup analyses a dependency of this effect on the quality of TTR control in the VKA group. Gómez-Outes et al. [28] found that the positive effects of NOACs versus warfarin on non-hemorrhagic strokes and systemic embolic events and on mortality were present in centers that only achieved a TTR below 65% in the warfarin arm. Similarly Ruff et al. [31] showed in a recent meta-analysis that there was a trend for a lower risk reduction of NOACs on stroke and systemic embolism as well as on major bleeding in centers that achieved a TTR of 66% or better (P of interaction 0.60 and 0.022, respectively).
As with any antithrombotic treatment, anticoagulation with VKA bears the risk of bleeding complications which are regarded as the main adverse event of anticoagulant treatment. In our analysis, minor bleeding complications were infrequently recorded with <1 event per patient-year. More than half of these events were bruises, which are generally without any clinical relevance, and nosebleeds. Other bleeding manifestations such as conjunctival bleeds, hematuria, gastrointestinal bleeding indicated by black or bloody stool, and muscle bleeds were rarely observed. This indicates that VKA accompanied by self-testing not only improves the control of INR values but also leads to acceptable bleeding rates, indicating a high level of treatment safety. It should be mentioned that the distribution and prevalence of bleeding manifestations observed for patients performing self-testing with INRatio2 or CoaguChek XS were not significantly different for most bleeding manifestations, and only for hematuria and conjunctival bleeds, patients using CoaguChek XS experienced a statistically higher frequency than patients using INRatio2. The rate of patient-reported minor thrombotic events in the NTS data was low at 2% per patient year.
Compared to the mentioned minor events, fatal events were even less frequent. In total, 71 events were reported, yielding a death rate of 1.9–2.1 per 100 patient-years. This is well below the rate of fatality observed in patients with clinic-based INR measurements, and compares favorably with the death rates for the warfarin groups reported in recent clinical trials in atrial fibrillation, 4.13%/year [32], 4.9%/year [33] and 3.94%/year [34]. The meta-analysis of Rose and colleagues [35] reported death rates of 2.3–8.1 per 100 patient-years based on 15 randomized controlled trials. Similarly, Heneghan et al. [12] found an average death rate of 3.9% while in self-monitoring this rate was reduced to 2.4%.
It should be mentioned that the frequency in use of the CoaguChek XS and the INRatio2 did not differ significantly among patients experiencing fatal events, in either univariate or multivariate analysis. In the latter statistic approach, high target INR (3.0–4.0) and, most prominently, older age at the start of anticoagulation significantly influenced the risk, and 1 year of higher age increased the HR by 8%. Thus, self-testing was found to be efficient in reduction of fatal events, regardless of the monitor used for INR determination.
Under VKA treatment, the quality of INR adjustment and the resulting TTR is strongly correlated with the outcome of patients in terms of thrombotic events and the rate of complications, particularly anticoagulant-induced bleeding. Regarding the quality of INR control, a high TTR of 87.9% was observed in the patients in this analysis. It should be noted that this analysis of Dutch patients used a therapeutic INR range of 2.0–3.5 for most of the patients, while internationally a target range of 2.0–3.0 is used for most indications for VKA anticoagulation. The corresponding time in target range for the NTS data is calculated at 68.9%, which bears close comparison to the recently published STABLE retrospective analysis of 24,907 warfarin-anticoagulated patients on INR self-testing, with an overall TTR of 69.7% [8]. It should be noted though that maintenance within this narrower range is not a priority for NTS. Comparison with TTR values reported from randomized clinical trials is difficult because of the differences in parameters measured, level of monitoring and pre-specified endpoints.
Apart from TTR, the frequency of critical INR values is an important indicator for the quality of VKA anticoagulation; this aspect has even been regarded to be more suitable for the prediction of clinical events than the TTR. As with others, critical INR values were defined as those below 1.5, bearing a considerable risk for thrombotic or thromboembolic events, and those above 5.0, predisposing for bleeding complications [8, 19]. In our data, an average of 2.4% of the INR values per patient was within the critical range. The frequency of critical values observed in this study of an average of 0.085 per month compares slightly favorably to the overall average frequency of 0.096 per month implied in the STABLE population [8]. This is interesting since the two populations not only used different VKA (in the USA predominantly warfarin, which has a longer half-life than acenocoumarol but shorter than phenprocoumon), but in addition medical practice in the NTS population favoured the somewhat more aggressive treatment of atrial fibrillation to an INR target range of 2.5–3.5. This suggests that patient self-testing is able to achieve this more aggressive target in the Netherlands with the same quality of control, shown by the equivalent TTR. In general, the results indicate a high quality of INR control in the NTS population, indicated by both high TTR and low prevalence of critical INR values. This raises the question whether the good INR control resulted in an effective prevention of thrombotic and thromboembolic events on the one hand and the prevention of serious complications of treatment on the other.
Taken together the self-testing population analyzed in the Netherlands compares very similarly in setup and therapy control to the populations studied elsewhere. This INR management system seems representative of a typical self-monitoring therapy with the associated beneficial effects on therapy control. The analysis demonstrates a good level of INR control and, consequently, high TTR in patients performing self-testing of INR. As shown, good INR control by self-testing also leads to high efficacy of treatment and high treatment safety, indicated particularly by an acceptable prevalence of minor bleeding complications and low death rate due to major clinical events under VKA treatment.
A review of the literature on the analytical performance of point of care INR monitors, including CoaguChek XS and INRatio among others, concludes that in general they have adequate precision and accuracy for clinical use [36]. The effect of the choice of home monitor to measure INR has to our knowledge so far not been studied in a large population. A recent Health Technology Assessment (HTA) report in the UK noted that CoaguChek XS and INRatio2 had similar performance and their measurements correlated well with standard laboratory tests for INR [37]. However, this report also suggested that small differences in design or usability could have an impact on outcomes such as TTR or clinical events. Azarnoush et al. [38] did not find statistically significant differences for the clinical outcomes of 50 patients with mechanical valves using CoaguChek versus 40 patients using INRatio. Similarly Hemkens et al. [39] found that “the absolute and relative differences were not substantially different between both devices” in a study of 62 patients using INRatio and 65 patients using CoaguChek S for self-monitoring for any indication of VKA-therapy.
In contrast to these small clinical trials, in this retrospective analysis results of more than 4,000 patients managed by the NTS using CoaguChek XS and INRatio2 with the same clinical protocol are reported. The current analysis adds to this understanding regarding the differences between the two monitors on both surrogate outcome parameters and clinical endpoints. While in the univariate comparison CoaguChek XS shows a statistically non-significant advantage of 1.1%, correcting for all identified influencers on the TTR such as gender, age, indications, medication, and target range still resulted in only a 1.0% difference in TTR, which was statistically significant. However, there was no difference in the distribution of minor clinical events that were self-reported by patients and the effect of the minor clinical events of the two monitors was not statistically significant and varied between the monitors. More importantly, there was no statistically significant influence of the monitor type on mortality. Hence, the current evidence suggests that there is no clinically relevant difference on clinical events between these two monitors.
One of the key questions to be addressed is whether a 1.0% difference in TTR is relevant on outcomes other than clinical events. In accordance with others, this small difference was not considered to be practically relevant. Supporting this hypothesis, Rose et al. [35] showed in their model for a population of 67,077 patients based on a comprehensive meta-analysis that even TTR changes of 2.5% did not statistically significantly influence major clinical events like ischemic strokes or major hemorrhages, while impacting the death rate only marginally. Only at a 5% TTR change was there a significant influence on major clinical events. Similarly, Lam and colleagues [40] concluded that a TTR difference of 3.5% is not clinically relevant. The 1.0% difference observed between users of the two different monitors in the population of the NTS is well below these comparable TTR changes. Furthermore, the difference in TTR of the observed magnitude did not result in a notable difference between the incidences of minor clinical events. The CoaguChek XS showed a slight difference in two types of clinical event in multivariate statistical testing; however, this is deemed not to be clinically relevant and more likely due to the multiple tests performed in the large population analyzed. Most importantly, fatal events were not shown to be affected by the choice of the monitor in this analysis of over 4,000 patients.

Strengths and Limitations

The key strength of this retrospective analysis is the large population of more than 4,000 patients included, to our knowledge the largest consecutive cohort of self-monitoring patients studied in Europe. This population was analyzed based on the clinical practice observed in standard treatment, as opposed to the tightly defined processes of a randomized controlled trial. The population mix of gender, age and indications is representative of many INR patient self-monitoring programs.
In addition to the methodological shortcomings inherent to every retrospective study, the elimination of the first 3 months familiarization period removes initial non-therapeutic INRs and may not be consistent with how TTR is calculated in other studies. Another limitation is the slightly different definition of the therapeutic and target ranges used in the Netherlands. Lack of verified causes of major clinical events, including death, in the NTS data prevents comparison of safety parameters with other studies. Finally, patients referred for patient self-monitoring may represent a select population, although this would not impact the applicability of the data to other patient self-monitoring settings.
Taken together, we believe that these limitations do not materially impact our major conclusion on the clinically similar performance of INRatio2 and CoaguChek XS.

Conclusion

In our analysis of self-testing data from a large cohort of patients in the Netherlands, the effect of the choice of coagulation monitor (CoaguChek XS or INRatio2) on the TTR, minor and major safety outcomes of long-term anticoagulation management is clinically irrelevant. In contrast, other factors like patient gender, indication, choice of target range, and the VKA used exert a larger and statistically significant effect on the quality of INR management. Good INR control and high TTR, both of which can be achieved by self-testing, improve therapeutic efficacy and treatment safety for patients. Thus, self-testing should be promoted and recommended as an indispensable element in the monitoring of VKA coagulation. These results open the opportunity to look for other parameters to determine the choice of INR monitor, such as cost of the monitor and strips, ease of use and value added by the manufacturers in terms of service to patients and healthcare providers.

Acknowledgments

Sponsorship and article processing charges for this study were funded by Alere International, Cranfield, UK.
Dr. Rob Neeter, Chairman of the National Thrombosis Service, coordinated data retrieval and provided critical review of the manuscript.
Dr. Toby Galbraith of IMC Healthcare Communication, London, UK, provided editorial assistance, supported by Alere International.
Dr. Christian Kloss, Managing Director, Gesellschaft für Patientenhilfe DGP mbH (a subsidiary of Alere Health Improvement Atlanta) provided critical review of the manuscript.
Alfred Müller, of Analytic Services Unternehmensberatungsges. mbH, provided statistical support and calculations, supported by Alere International.
Jan Leendert Pouwel Brouwer collected data, drafted sections and provided critical review and approval of the manuscript.
Hugo Stoevelaar collected data and provided critical review and approval of the manuscript.
Christoph Sucker drafted sections and provided critical review and approval of the manuscript.
All authors had full access to all of the data in this study and take complete responsibility for the integrity of the data and accuracy of the data analysis. All authors meet the ICMJE criteria for authorship of this manuscript, take responsibility for the integrity of the work as a whole, and have given final approval for the version to be published.

Conflict of interest

Jan Leendert Pouwel Brouwer and Hugo Stoevelaar declare no conflict of interest and no financial or commercial relationships with relevant companies.
Christoph Sucker has provided consultancy in medical advice to Alere on other projects not related to this analysis.

Compliance with ethics guidelines

The analysis in this article is based on a retrospective examination of anonymous, aggregated patient data, and does not involve any new studies of human subjects performed by any of the authors.

Open Access

This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://​creativecommons.​org/​licenses/​by/​4.​0), which permits use, duplication, adaptation, distribution, and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

e.Med Allgemeinmedizin

Kombi-Abonnement

Mit e.Med Allgemeinmedizin erhalten Sie Zugang zu allen CME-Fortbildungen und Premium-Inhalten der allgemeinmedizinischen Zeitschriften, inklusive einer gedruckten Allgemeinmedizin-Zeitschrift Ihrer Wahl.

Anhänge

Electronic supplementary material

Below is the link to the electronic supplementary material.
Literatur
1.
Zurück zum Zitat European Heart Rhythm Association, European Association for Cardio-Thoracic Surgery, Camm AJ, et al. Guidelines for the management of atrial fibrillation: the task force for the management of atrial fibrillation of the European Society of Cardiology (ESC). Eur Heart J. 2010;31(19):2369–429.PubMedCrossRef European Heart Rhythm Association, European Association for Cardio-Thoracic Surgery, Camm AJ, et al. Guidelines for the management of atrial fibrillation: the task force for the management of atrial fibrillation of the European Society of Cardiology (ESC). Eur Heart J. 2010;31(19):2369–429.PubMedCrossRef
2.
Zurück zum Zitat Friberg L, Bergfeldt L. Atrial fibrillation prevalence revisited. J Intern Med. 2013;274(5):461–8.PubMedCrossRef Friberg L, Bergfeldt L. Atrial fibrillation prevalence revisited. J Intern Med. 2013;274(5):461–8.PubMedCrossRef
3.
Zurück zum Zitat Hart RG, Pearce LA, Aguilar MI. Meta-analysis: antithrombotic therapy to prevent stroke in patients who have nonvalvular atrial fibrillation. Ann Intern Med. 2007;146:857–67.PubMedCrossRef Hart RG, Pearce LA, Aguilar MI. Meta-analysis: antithrombotic therapy to prevent stroke in patients who have nonvalvular atrial fibrillation. Ann Intern Med. 2007;146:857–67.PubMedCrossRef
4.
Zurück zum Zitat Morgan CL, McEwan P, Tukiendorf A, Robinson PA, Clemens A, Plumb JM. Warfarin treatment in patients with atrial fibrillation: observing outcomes associated with varying levels of INR control. Thromb Res. 2009;124(1):37–41.PubMedCrossRef Morgan CL, McEwan P, Tukiendorf A, Robinson PA, Clemens A, Plumb JM. Warfarin treatment in patients with atrial fibrillation: observing outcomes associated with varying levels of INR control. Thromb Res. 2009;124(1):37–41.PubMedCrossRef
5.
Zurück zum Zitat Torn M, Cannegieter SC, Bollen WL, van der Meer FJ, van der Wall EE, Rosendaal FR. Optimal level of oral anticoagulant therapy for the prevention of arterial thrombosis in patients with mechanical heart valve prostheses, atrial fibrillation, or myocardial infarction: a prospective study of 4202 patients. Arch Intern Med. 2009;169(13):1203–9.PubMedCrossRef Torn M, Cannegieter SC, Bollen WL, van der Meer FJ, van der Wall EE, Rosendaal FR. Optimal level of oral anticoagulant therapy for the prevention of arterial thrombosis in patients with mechanical heart valve prostheses, atrial fibrillation, or myocardial infarction: a prospective study of 4202 patients. Arch Intern Med. 2009;169(13):1203–9.PubMedCrossRef
6.
Zurück zum Zitat Veeger NJ, Piersma-Wichers M, Tijssen JG, Hillege HL, van der Meer J. Individual time within target range in patients treated with vitamin K antagonists: main determinant of quality of anticoagulation and predictor of clinical outcome. A retrospective study of 2300 consecutive patients with venous thromboembolism. Br J Haematol. 2005;128(4):513–9.PubMedCrossRef Veeger NJ, Piersma-Wichers M, Tijssen JG, Hillege HL, van der Meer J. Individual time within target range in patients treated with vitamin K antagonists: main determinant of quality of anticoagulation and predictor of clinical outcome. A retrospective study of 2300 consecutive patients with venous thromboembolism. Br J Haematol. 2005;128(4):513–9.PubMedCrossRef
7.
Zurück zum Zitat Heneghan C, Ward A, Perera R, et al. Self-monitoring of oral anticoagulation: systematic review and meta-analysis of individual patient data. Lancet. 2012;379(9813):322–34.PubMedCrossRef Heneghan C, Ward A, Perera R, et al. Self-monitoring of oral anticoagulation: systematic review and meta-analysis of individual patient data. Lancet. 2012;379(9813):322–34.PubMedCrossRef
8.
Zurück zum Zitat DeSantis G, Hogan-Schlientz J, Liska G, et al. STABLE results: warfarin home monitoring achieves excellent INR control. Am J Manag Care. 2014;20(3):202–9.PubMed DeSantis G, Hogan-Schlientz J, Liska G, et al. STABLE results: warfarin home monitoring achieves excellent INR control. Am J Manag Care. 2014;20(3):202–9.PubMed
9.
Zurück zum Zitat Cumberworth A, Mabvuure NT, Hallam MJ, Hindocha S. Is home monitoring of international normalised ratio safer than clinic-based monitoring? Interact CardioVasc Thorac Surg. 2013;16(2):198–201.PubMedCentralPubMedCrossRef Cumberworth A, Mabvuure NT, Hallam MJ, Hindocha S. Is home monitoring of international normalised ratio safer than clinic-based monitoring? Interact CardioVasc Thorac Surg. 2013;16(2):198–201.PubMedCentralPubMedCrossRef
10.
Zurück zum Zitat Garcia-Alamino JM, Ward AM, Alonso-Coello P. Self-monitoring and self-management of oral anticoagulation. Cochrane Database Syst Rev. 2010;4:CD003839.PubMed Garcia-Alamino JM, Ward AM, Alonso-Coello P. Self-monitoring and self-management of oral anticoagulation. Cochrane Database Syst Rev. 2010;4:CD003839.PubMed
11.
Zurück zum Zitat Bloomfield HE, Krause A, Greer N, et al. Meta-analysis: effect of patient self-testing and self-management of long-term anticoagulation on major clinical outcomes. Ann Intern Med. 2011;154:472–82.PubMedCrossRef Bloomfield HE, Krause A, Greer N, et al. Meta-analysis: effect of patient self-testing and self-management of long-term anticoagulation on major clinical outcomes. Ann Intern Med. 2011;154:472–82.PubMedCrossRef
12.
Zurück zum Zitat Heneghan C, Alonso-Coello P, Garcia-Alamino JM, Perera R, Meats E, Glasziou P. Self-monitoring of oral anticoagulation: a systematic review and meta-analysis. Lancet. 2006;367(9508):S404–11.CrossRef Heneghan C, Alonso-Coello P, Garcia-Alamino JM, Perera R, Meats E, Glasziou P. Self-monitoring of oral anticoagulation: a systematic review and meta-analysis. Lancet. 2006;367(9508):S404–11.CrossRef
13.
Zurück zum Zitat Holbrook A, Schulman S, Witt DM, et al. Evidence-based management of anticoagulant therapy: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2012;141(2 Suppl):e152S–84S.PubMedCentralPubMed Holbrook A, Schulman S, Witt DM, et al. Evidence-based management of anticoagulant therapy: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2012;141(2 Suppl):e152S–84S.PubMedCentralPubMed
14.
Zurück zum Zitat Keeling D, Baglin T, Tait C, et al. Guidelines on oral anticoagulation with warfarin––fourth edition. Br J Haematol. 2011;154(3):311–24.PubMedCrossRef Keeling D, Baglin T, Tait C, et al. Guidelines on oral anticoagulation with warfarin––fourth edition. Br J Haematol. 2011;154(3):311–24.PubMedCrossRef
15.
Zurück zum Zitat Jones M, McEwan P, Morgan CL, Peters JR, Goodfellow J, Currie CJ. Evaluation of the pattern of treatment, level of anticoagulation control, and outcome of treatment with warfarin in patients with non-valvar atrial fibrillation: a record linkage study in a large British population. Heart. 2005;91:472–7.PubMedCentralPubMedCrossRef Jones M, McEwan P, Morgan CL, Peters JR, Goodfellow J, Currie CJ. Evaluation of the pattern of treatment, level of anticoagulation control, and outcome of treatment with warfarin in patients with non-valvar atrial fibrillation: a record linkage study in a large British population. Heart. 2005;91:472–7.PubMedCentralPubMedCrossRef
16.
Zurück zum Zitat Gallagher AM, Setakis E, Plumb JM, Clemens A, van Staa TP. Risks of stroke and mortality associated with suboptimal anticoagulation in atrial fibrillation patients. Thromb Haemost. 2011;106(5):968–77.PubMedCrossRef Gallagher AM, Setakis E, Plumb JM, Clemens A, van Staa TP. Risks of stroke and mortality associated with suboptimal anticoagulation in atrial fibrillation patients. Thromb Haemost. 2011;106(5):968–77.PubMedCrossRef
17.
Zurück zum Zitat Rose AJ, Hylek EM, Ozonoff A, Ash AS, Reisman JI, Berlowitz DR. Risk-adjusted percent time in therapeutic range as a quality indicator for outpatient oral anticoagulation: results of the Veterans Affairs study to improve anticoagulation (VARIA). Circ Cardiovasc Qual Outcomes. 2011;4(1):22–9.PubMedCrossRef Rose AJ, Hylek EM, Ozonoff A, Ash AS, Reisman JI, Berlowitz DR. Risk-adjusted percent time in therapeutic range as a quality indicator for outpatient oral anticoagulation: results of the Veterans Affairs study to improve anticoagulation (VARIA). Circ Cardiovasc Qual Outcomes. 2011;4(1):22–9.PubMedCrossRef
18.
Zurück zum Zitat Rose AJ, Hylek EM, Ozonoff A, Ash AS, Reisman JI, Berlowitz DR. Patient characteristics associated with oral anticoagulation control: results of the Veterans affairs study to improve anticoagulation (VARIA). J Thromb Haemost. 2010;8(10):2182–91.PubMedCrossRef Rose AJ, Hylek EM, Ozonoff A, Ash AS, Reisman JI, Berlowitz DR. Patient characteristics associated with oral anticoagulation control: results of the Veterans affairs study to improve anticoagulation (VARIA). J Thromb Haemost. 2010;8(10):2182–91.PubMedCrossRef
19.
Zurück zum Zitat Ansell J, Hirsh J, Hylek E, Jacobson A, Crowther M, Palareti G. Pharmacology and management of the vitamin K antagonists: American College of Chest Physicians evidence-based clinical practice guidelines (8th edition). Chest. 2008;133:160S–98S.PubMedCrossRef Ansell J, Hirsh J, Hylek E, Jacobson A, Crowther M, Palareti G. Pharmacology and management of the vitamin K antagonists: American College of Chest Physicians evidence-based clinical practice guidelines (8th edition). Chest. 2008;133:160S–98S.PubMedCrossRef
20.
Zurück zum Zitat Lind M, Fahlen M, Kosiborod M, Eliasson B, Odén A. Variability of INR and its relationship with mortality, stroke, bleeding and hospitalisations in patients with atrial fibrillation. Thromb Res. 2012;129:32–5.PubMedCrossRef Lind M, Fahlen M, Kosiborod M, Eliasson B, Odén A. Variability of INR and its relationship with mortality, stroke, bleeding and hospitalisations in patients with atrial fibrillation. Thromb Res. 2012;129:32–5.PubMedCrossRef
21.
Zurück zum Zitat van Dolder BD, van Geest-Daalderop JJH, van’t Land RP, Levi MM, Piersma-Wichers G. De kunst van het doseren: Richtlijn, leidraad en informatie voor het doseren van vitamine K-antagonisten. Available from http://www.fnt.nl/. Accessed April 2014 (in Dutch). van Dolder BD, van Geest-Daalderop JJH, van’t Land RP, Levi MM, Piersma-Wichers G. De kunst van het doseren: Richtlijn, leidraad en informatie voor het doseren van vitamine K-antagonisten. Available from http://​www.​fnt.​nl/​. Accessed April 2014 (in Dutch).
22.
Zurück zum Zitat Bezemer ID, Roemer WH, Penning-van Beest FJ, van Eekelen E, Kramer MH. INR control calculation: comparison of Dutch and international methods. Neth J Med. 2013;71(4):194–8.PubMed Bezemer ID, Roemer WH, Penning-van Beest FJ, van Eekelen E, Kramer MH. INR control calculation: comparison of Dutch and international methods. Neth J Med. 2013;71(4):194–8.PubMed
23.
Zurück zum Zitat Erkens PM, ten Cate H, Büller HR, Prins MH. Benchmark for time in therapeutic range in venous thromboembolism: a systematic review and meta-analysis. PLoS One. 2012;7(9):e42269.PubMedCentralPubMedCrossRef Erkens PM, ten Cate H, Büller HR, Prins MH. Benchmark for time in therapeutic range in venous thromboembolism: a systematic review and meta-analysis. PLoS One. 2012;7(9):e42269.PubMedCentralPubMedCrossRef
24.
Zurück zum Zitat Rosendaal R, Cannegieter S, van der Meer F, van der Meer F, Briet E. A method to determine the optimal intensity of oral anticoagulant therapy. Thromb Haemost. 1993;69(3):236–9.PubMed Rosendaal R, Cannegieter S, van der Meer F, van der Meer F, Briet E. A method to determine the optimal intensity of oral anticoagulant therapy. Thromb Haemost. 1993;69(3):236–9.PubMed
25.
Zurück zum Zitat Prentice RL, Williams BJ, Peterson AV. On the regression analysis of multiple failure time data. Biometrika. 1981;68(2):373–9.CrossRef Prentice RL, Williams BJ, Peterson AV. On the regression analysis of multiple failure time data. Biometrika. 1981;68(2):373–9.CrossRef
26.
Zurück zum Zitat Lin DY, Wei LJ. The robust inference for the Cox proportional hazards model. J Am Stat Assoc. 1989;84:1074–8.CrossRef Lin DY, Wei LJ. The robust inference for the Cox proportional hazards model. J Am Stat Assoc. 1989;84:1074–8.CrossRef
27.
Zurück zum Zitat Wallentin L, Yusuf S, Ezekowitz MD, et al. Efficacy and safety of dabigatran compared with warfarin at different levels of international normalised ratio control for stroke prevention in atrial fibrillation: an analysis of the RE-LY trial. Lancet. 2010;376(9745):975–83.PubMedCrossRef Wallentin L, Yusuf S, Ezekowitz MD, et al. Efficacy and safety of dabigatran compared with warfarin at different levels of international normalised ratio control for stroke prevention in atrial fibrillation: an analysis of the RE-LY trial. Lancet. 2010;376(9745):975–83.PubMedCrossRef
28.
Zurück zum Zitat Gómez-Outes A, Terleira-Fernández AI, Calvo-Rojas G, Suárez-Gea ML, Vargas-Castrillón E. Dabigatran, rivaroxaban, or apixaban versus warfarin in patients with nonvalvular atrial fibrillation: a systematic review and meta-analysis of subgroups. Thrombosis. 2013;2013:640723.PubMedCentralPubMedCrossRef Gómez-Outes A, Terleira-Fernández AI, Calvo-Rojas G, Suárez-Gea ML, Vargas-Castrillón E. Dabigatran, rivaroxaban, or apixaban versus warfarin in patients with nonvalvular atrial fibrillation: a systematic review and meta-analysis of subgroups. Thrombosis. 2013;2013:640723.PubMedCentralPubMedCrossRef
29.
Zurück zum Zitat Di Minno MN, Russolillo A, Di Minno A, Camera M, Parolari A, Tremoli E. Direct anticoagulant drugs to overcome limitations of vitamin K antagonists. A critical appraisal of data in atrial fibrillation patients. Expert Opin Emerg Drugs. 2013;18(1):9–23.PubMedCrossRef Di Minno MN, Russolillo A, Di Minno A, Camera M, Parolari A, Tremoli E. Direct anticoagulant drugs to overcome limitations of vitamin K antagonists. A critical appraisal of data in atrial fibrillation patients. Expert Opin Emerg Drugs. 2013;18(1):9–23.PubMedCrossRef
30.
Zurück zum Zitat Giugliano RP, Ruff CT, Braunwald E, et al. Edoxaban versus warfarin in patients with atrial fibrillation. N Engl J Med. 2013;369(22):2093–104.PubMedCrossRef Giugliano RP, Ruff CT, Braunwald E, et al. Edoxaban versus warfarin in patients with atrial fibrillation. N Engl J Med. 2013;369(22):2093–104.PubMedCrossRef
31.
Zurück zum Zitat Ruff CT, Giugliano RP, Braunwald E, et al. Comparison of the efficacy and safety of new oral anticoagulants with warfarin in patients with atrial fibrillation: a meta-analysis of randomised trials. Lancet. 2014;383(9921):955–62.PubMedCrossRef Ruff CT, Giugliano RP, Braunwald E, et al. Comparison of the efficacy and safety of new oral anticoagulants with warfarin in patients with atrial fibrillation: a meta-analysis of randomised trials. Lancet. 2014;383(9921):955–62.PubMedCrossRef
32.
Zurück zum Zitat Connolly SJ, Ezekowitz MD, Yusuf S, et al. Dabigatran versus warfarin in patients with atrial fibrillation. N Engl J Med. 2009;361(12):1139–51.PubMedCrossRef Connolly SJ, Ezekowitz MD, Yusuf S, et al. Dabigatran versus warfarin in patients with atrial fibrillation. N Engl J Med. 2009;361(12):1139–51.PubMedCrossRef
33.
Zurück zum Zitat Patel MR, Mahaffey KW, Garg J, et al. Rivaroxaban versus warfarin in nonvalvular atrial fibrillation. N Engl J Med. 2011;365(10):883–91.PubMedCrossRef Patel MR, Mahaffey KW, Garg J, et al. Rivaroxaban versus warfarin in nonvalvular atrial fibrillation. N Engl J Med. 2011;365(10):883–91.PubMedCrossRef
34.
Zurück zum Zitat Granger CB, Alexander JH, McMurray JJ, et al. Apixaban versus warfarin in patients with atrial fibrillation. N Engl J Med. 2011;365(11):981–92.PubMedCrossRef Granger CB, Alexander JH, McMurray JJ, et al. Apixaban versus warfarin in patients with atrial fibrillation. N Engl J Med. 2011;365(11):981–92.PubMedCrossRef
35.
Zurück zum Zitat Rose AJ, Berlowitz DR, Ash AS, Ozonoff A, Hylek EM, Goldhaber-Fiebert JD. The business case for quality improvement: oral anticoagulation for atrial fibrillation. Circ Cardiovasc Qual Outcomes. 2011;4(4):416–24.PubMedCentralPubMedCrossRef Rose AJ, Berlowitz DR, Ash AS, Ozonoff A, Hylek EM, Goldhaber-Fiebert JD. The business case for quality improvement: oral anticoagulation for atrial fibrillation. Circ Cardiovasc Qual Outcomes. 2011;4(4):416–24.PubMedCentralPubMedCrossRef
36.
Zurück zum Zitat Christensen TD, Larsen TB. Precision and accuracy of point-of-care testing coagulometers used for self-testing and self-management of oral anticoagulation therapy. J Thromb Haemost. 2012;10:251–60.PubMedCrossRef Christensen TD, Larsen TB. Precision and accuracy of point-of-care testing coagulometers used for self-testing and self-management of oral anticoagulation therapy. J Thromb Haemost. 2012;10:251–60.PubMedCrossRef
37.
Zurück zum Zitat Sharma P, Scotland G, Cruickshank M, et al. Clinical and cost-effectiveness of point-of-care tests (CoaguChek system, INRatio2 PT/INR monitor and ProTime microcoagulation system) for the self-monitoring of the coagulation status of people receiving long-term vitamin K antagonist therapy compared with standard UK practice: systematic review and economic evaluation. Aberdeen HTA Group, Institute of Applied Health Sciences, University of Aberdeen, 2013. Available from http://www.nice.org.uk/nicemedia/live/14091/66498/66498.pdf. Accessed May 2014. Sharma P, Scotland G, Cruickshank M, et al. Clinical and cost-effectiveness of point-of-care tests (CoaguChek system, INRatio2 PT/INR monitor and ProTime microcoagulation system) for the self-monitoring of the coagulation status of people receiving long-term vitamin K antagonist therapy compared with standard UK practice: systematic review and economic evaluation. Aberdeen HTA Group, Institute of Applied Health Sciences, University of Aberdeen, 2013. Available from http://​www.​nice.​org.​uk/​nicemedia/​live/​14091/​66498/​66498.​pdf. Accessed May 2014.
38.
Zurück zum Zitat Azarnoush K, Camilleri L, Aublet-Cuvelier B, et al. Results of the first randomized French study evaluating self-testing of the international normalized ratio. J Heart Valve Dis. 2011;20(5):518–25.PubMed Azarnoush K, Camilleri L, Aublet-Cuvelier B, et al. Results of the first randomized French study evaluating self-testing of the international normalized ratio. J Heart Valve Dis. 2011;20(5):518–25.PubMed
39.
Zurück zum Zitat Hemkens LG, Hilden KM, Hartschen S, et al. A randomized trial comparing INR monitoring devices in patients with anticoagulation self-management: evaluation of a novel error-grid approach. J Thromb Thrombolysis. 2008;26:22–30.PubMedCrossRef Hemkens LG, Hilden KM, Hartschen S, et al. A randomized trial comparing INR monitoring devices in patients with anticoagulation self-management: evaluation of a novel error-grid approach. J Thromb Thrombolysis. 2008;26:22–30.PubMedCrossRef
40.
Zurück zum Zitat Lam J, Schulman S, Witt DM, Vandvik PO, Qayyum F, Holbrook AM. Anticoagulation control with daily low-dose vitamin K to reduce clinically adverse outcomes and international normalized ratio variability: a systematic review and meta-analysis. Pharmacotherapy. 2013;33(11):1184–90.PubMedCrossRef Lam J, Schulman S, Witt DM, Vandvik PO, Qayyum F, Holbrook AM. Anticoagulation control with daily low-dose vitamin K to reduce clinically adverse outcomes and international normalized ratio variability: a systematic review and meta-analysis. Pharmacotherapy. 2013;33(11):1184–90.PubMedCrossRef
Metadaten
Titel
The Clinical Impact of Different Coagulometers on Patient Outcomes
verfasst von
Jan Leendert Pouwel Brouwer
Hugo Stoevelaar
Christoph Sucker
Publikationsdatum
01.06.2014
Verlag
Springer Healthcare
Erschienen in
Advances in Therapy / Ausgabe 6/2014
Print ISSN: 0741-238X
Elektronische ISSN: 1865-8652
DOI
https://doi.org/10.1007/s12325-014-0124-x

Weitere Artikel der Ausgabe 6/2014

Advances in Therapy 6/2014 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.