Skip to main content
Erschienen in: Breast Cancer 3/2013

01.07.2013 | Review Article

The emerging role of breast tomosynthesis

verfasst von: Takayoshi Uematsu

Erschienen in: Breast Cancer | Ausgabe 3/2013

Einloggen, um Zugang zu erhalten

Abstract

Digital breast tomosynthesis (DBT) is a new modality that aids in breast cancer detection. It is a pseudo-three-dimensional digital mammography imaging system that produces a series of 1-mm-slice images with multiple very low-dose X-ray projections to reveal the inner architecture of the breast after eliminating interference from overlapping breast tissue. This review article provides an overview of the current and potential use of DBT. The illustrations and discussion are based on our experience with the Selenia Dimensions (Hologic, USA) DBT system approved by the US Food and Drug Administration.
Literatur
1.
Zurück zum Zitat Ziedes des Plantes B.G.: Eine Neue Methode Zur Diffenzierung in der Rontgenographie (Planigraphie) (in German). Acta Radiol. 1932;13:182–92. Ziedes des Plantes B.G.: Eine Neue Methode Zur Diffenzierung in der Rontgenographie (Planigraphie) (in German). Acta Radiol. 1932;13:182–92.
2.
Zurück zum Zitat Niklason LT, Christian BT, Niklason LE, et al. Digital tomosynthesis in breast imaging. Radiology. 1997;205:399–406.PubMed Niklason LT, Christian BT, Niklason LE, et al. Digital tomosynthesis in breast imaging. Radiology. 1997;205:399–406.PubMed
3.
4.
Zurück zum Zitat Feng SS, Sechopoulos I. Clinical digital breast tomosynthesis system: dosimetric characterization. Radiology. 2012;263:35–42.CrossRefPubMed Feng SS, Sechopoulos I. Clinical digital breast tomosynthesis system: dosimetric characterization. Radiology. 2012;263:35–42.CrossRefPubMed
5.
Zurück zum Zitat Olgar T, Kahn T, Gosch D. Average glandular dose in digital mammography and breast tomosynthesis. Rofo. 2012;184:911–8.CrossRefPubMed Olgar T, Kahn T, Gosch D. Average glandular dose in digital mammography and breast tomosynthesis. Rofo. 2012;184:911–8.CrossRefPubMed
6.
Zurück zum Zitat Ren B, Ruth C, Wu T, et al. A new generation FFDM/tomosynthesis fusion system with selenium detector. Proc SPIE. 2010;7622:76211B–20B. Ren B, Ruth C, Wu T, et al. A new generation FFDM/tomosynthesis fusion system with selenium detector. Proc SPIE. 2010;7622:76211B–20B.
7.
Zurück zum Zitat Machida H, Yuhara T, Mori T, Ueno E, Moribe Y, Sabol JM. Optimizing parameters for flat-panel detector digital tomosynthesis. Radiographics. 2010;30:549–62.CrossRefPubMed Machida H, Yuhara T, Mori T, Ueno E, Moribe Y, Sabol JM. Optimizing parameters for flat-panel detector digital tomosynthesis. Radiographics. 2010;30:549–62.CrossRefPubMed
8.
Zurück zum Zitat American College of Radiology. Breast imaging reporting and data system (BI-RADS). 4th ed. Reston: American College of Radiology; 2003. American College of Radiology. Breast imaging reporting and data system (BI-RADS). 4th ed. Reston: American College of Radiology; 2003.
9.
Zurück zum Zitat Burrell HC, Sibbering DM, Wilson AR, et al. Screening interval breast cancers: mammographic features and prognosis factors. Radiology. 1996;199:811–7.PubMed Burrell HC, Sibbering DM, Wilson AR, et al. Screening interval breast cancers: mammographic features and prognosis factors. Radiology. 1996;199:811–7.PubMed
10.
Zurück zum Zitat Rangayyan RM, Banik S, Desautels JE. Computer-aided detection of architectural distortion in prior mammograms of interval cancer. J Digit Imaging. 2010;23:611–31.CrossRefPubMed Rangayyan RM, Banik S, Desautels JE. Computer-aided detection of architectural distortion in prior mammograms of interval cancer. J Digit Imaging. 2010;23:611–31.CrossRefPubMed
11.
Zurück zum Zitat Nemoto M, Honmura S, Shimizu A, Furukawa D, Kobatake H, Nawano S. A pilot study of architectural distortion detection in mammograms based on characteristics of line shadows. Int J Comput Assist Radiol Surg. 2009;4:27–36.CrossRefPubMed Nemoto M, Honmura S, Shimizu A, Furukawa D, Kobatake H, Nawano S. A pilot study of architectural distortion detection in mammograms based on characteristics of line shadows. Int J Comput Assist Radiol Surg. 2009;4:27–36.CrossRefPubMed
12.
Zurück zum Zitat Biswas SK, Mukherjee DP. Recognizing architectural distortion in mammogram: a multiscale texture modeling approach with GMM. IEEE Trans Biomed Eng. 2011;58:2023–30.CrossRefPubMed Biswas SK, Mukherjee DP. Recognizing architectural distortion in mammogram: a multiscale texture modeling approach with GMM. IEEE Trans Biomed Eng. 2011;58:2023–30.CrossRefPubMed
13.
Zurück zum Zitat Teertstra HJ, Loo CE, van den Bosch MA, et al. Breast tomosynthesis in clinical practice: initial results. Eur Radiol. 2010;20:16–24.CrossRefPubMed Teertstra HJ, Loo CE, van den Bosch MA, et al. Breast tomosynthesis in clinical practice: initial results. Eur Radiol. 2010;20:16–24.CrossRefPubMed
14.
Zurück zum Zitat Uematsu T, Kasami M. MR imaging findings of benign and malignant circumscribed breast masses: part 1. Solid circumscribed masses. Jpn J Radiol. 2009;27:395–404.CrossRefPubMed Uematsu T, Kasami M. MR imaging findings of benign and malignant circumscribed breast masses: part 1. Solid circumscribed masses. Jpn J Radiol. 2009;27:395–404.CrossRefPubMed
15.
Zurück zum Zitat Uematsu T, Kasami M. MR imaging findings of benign and malignant circumscribed breast masses: part 2. Cystic circumscribed masses. Jpn J Radiol. 2009;27:405–9.CrossRefPubMed Uematsu T, Kasami M. MR imaging findings of benign and malignant circumscribed breast masses: part 2. Cystic circumscribed masses. Jpn J Radiol. 2009;27:405–9.CrossRefPubMed
16.
Zurück zum Zitat Andersson I, Ikeda DM, Zackrisson S, et al. Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings. Eur Radiol. 2008;18:2817–25.CrossRefPubMed Andersson I, Ikeda DM, Zackrisson S, et al. Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings. Eur Radiol. 2008;18:2817–25.CrossRefPubMed
17.
Zurück zum Zitat Spangler ML, Zuley ML, Sumkin JH, et al. Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. AJR Am J Roentgenol. 2011;196:320–4.CrossRefPubMed Spangler ML, Zuley ML, Sumkin JH, et al. Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. AJR Am J Roentgenol. 2011;196:320–4.CrossRefPubMed
18.
Zurück zum Zitat Kopans D, Gavenonis S, Halpern E, Moore R. Calcifications in the breast and digital breast tomosynthesis. Breast J. 2011;17:638–44.CrossRefPubMed Kopans D, Gavenonis S, Halpern E, Moore R. Calcifications in the breast and digital breast tomosynthesis. Breast J. 2011;17:638–44.CrossRefPubMed
19.
Zurück zum Zitat Timberg P, Båth M, Andersson I, Mattsson S, Tingberg A, Ruschin M. In-plane visibility of lesions using breast tomosynthesis and digital mammography. Med Phys. 2010;37:5618–26.CrossRefPubMed Timberg P, Båth M, Andersson I, Mattsson S, Tingberg A, Ruschin M. In-plane visibility of lesions using breast tomosynthesis and digital mammography. Med Phys. 2010;37:5618–26.CrossRefPubMed
20.
Zurück zum Zitat Poplack SP, Tosteson TD, Kogel CA, Nagy HM. Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. AJR Am J Roentgenol. 2007;189:616–23.CrossRefPubMed Poplack SP, Tosteson TD, Kogel CA, Nagy HM. Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. AJR Am J Roentgenol. 2007;189:616–23.CrossRefPubMed
21.
Zurück zum Zitat Zhou J, Zhao B, Zhao W. A computer simulation platform for the optimization of a breast tomosynthesis system. Med Phys. 2007;34:1098–109.CrossRefPubMed Zhou J, Zhao B, Zhao W. A computer simulation platform for the optimization of a breast tomosynthesis system. Med Phys. 2007;34:1098–109.CrossRefPubMed
22.
Zurück zum Zitat Wallis MG, Moa E, Zanca F, Leifland K, Danielsson M. Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study. Radiology. 2012;262:788–96.CrossRefPubMed Wallis MG, Moa E, Zanca F, Leifland K, Danielsson M. Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-ray imaging observer study. Radiology. 2012;262:788–96.CrossRefPubMed
24.
Zurück zum Zitat Saunders RS Jr, Samei E, Lo JY, Baker JA. Can compression be reduced for breast tomosynthesis? Monte Carlo study on mass and microcalcification conspicuity in tomosynthesis. Radiology. 2009;251:673–82.CrossRefPubMed Saunders RS Jr, Samei E, Lo JY, Baker JA. Can compression be reduced for breast tomosynthesis? Monte Carlo study on mass and microcalcification conspicuity in tomosynthesis. Radiology. 2009;251:673–82.CrossRefPubMed
25.
Zurück zum Zitat Förnvik D, Andersson I, Svahn T, Timberg P, Zackrisson S, Tingberg A. The effect of reduced breast compression in breast tomosynthesis: human observer study using clinical cases. Radiat Prot Dosimetry. 2010;139:118–23.CrossRefPubMed Förnvik D, Andersson I, Svahn T, Timberg P, Zackrisson S, Tingberg A. The effect of reduced breast compression in breast tomosynthesis: human observer study using clinical cases. Radiat Prot Dosimetry. 2010;139:118–23.CrossRefPubMed
26.
Zurück zum Zitat Tagliafico A, Astengo D, Cavagnetto F, et al. One-to-one comparison between digital spot compression view and digital breast tomosynthesis. Eur Radiol. 2012;22:539–44.CrossRefPubMed Tagliafico A, Astengo D, Cavagnetto F, et al. One-to-one comparison between digital spot compression view and digital breast tomosynthesis. Eur Radiol. 2012;22:539–44.CrossRefPubMed
27.
Zurück zum Zitat Hakim CM, Chough DM, Ganott MA, Sumkin JH, Zuley ML, Gur D. Digital breast tomosynthesis in the diagnostic environment: a subjective side-by-side review. AJR Am J Roentgenol. 2010;195:W172–6.CrossRefPubMed Hakim CM, Chough DM, Ganott MA, Sumkin JH, Zuley ML, Gur D. Digital breast tomosynthesis in the diagnostic environment: a subjective side-by-side review. AJR Am J Roentgenol. 2010;195:W172–6.CrossRefPubMed
28.
Zurück zum Zitat Gur D, Zuley ML, Anello MI, et al. Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study. Acad Radiol. 2012;19:166–71.CrossRefPubMed Gur D, Zuley ML, Anello MI, et al. Dose reduction in digital breast tomosynthesis (DBT) screening using synthetically reconstructed projection images: an observer performance study. Acad Radiol. 2012;19:166–71.CrossRefPubMed
29.
Zurück zum Zitat Michell MJ, Iqbal A, Wasan RK, et al. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis. Clin Radiol. 2012;67:976–81.CrossRefPubMed Michell MJ, Iqbal A, Wasan RK, et al. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis. Clin Radiol. 2012;67:976–81.CrossRefPubMed
30.
Zurück zum Zitat Carney PA, Miglioretti DL, Yankaskas BC, et al. Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Intern Med. 2003;138:168–75.CrossRefPubMed Carney PA, Miglioretti DL, Yankaskas BC, et al. Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Intern Med. 2003;138:168–75.CrossRefPubMed
Metadaten
Titel
The emerging role of breast tomosynthesis
verfasst von
Takayoshi Uematsu
Publikationsdatum
01.07.2013
Verlag
Springer Japan
Erschienen in
Breast Cancer / Ausgabe 3/2013
Print ISSN: 1340-6868
Elektronische ISSN: 1880-4233
DOI
https://doi.org/10.1007/s12282-013-0456-4

Weitere Artikel der Ausgabe 3/2013

Breast Cancer 3/2013 Zur Ausgabe

Alter verschlechtert Prognose bei Endometriumkarzinom

11.05.2024 Endometriumkarzinom Nachrichten

Ein höheres Alter bei der Diagnose eines Endometriumkarzinoms ist mit aggressiveren Tumorcharakteristika assoziiert, scheint aber auch unabhängig von bekannten Risikofaktoren die Prognose der Erkrankung zu verschlimmern.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Erhöhte Mortalität bei postpartalem Brustkrebs

07.05.2024 Mammakarzinom Nachrichten

Auch für Trägerinnen von BRCA-Varianten gilt: Erkranken sie fünf bis zehn Jahre nach der letzten Schwangerschaft an Brustkrebs, ist das Sterberisiko besonders hoch.

Hypertherme Chemotherapie bietet Chance auf Blasenerhalt

07.05.2024 Harnblasenkarzinom Nachrichten

Eine hypertherme intravesikale Chemotherapie mit Mitomycin kann für Patienten mit hochriskantem nicht muskelinvasivem Blasenkrebs eine Alternative zur radikalen Zystektomie darstellen. Kölner Urologen berichten über ihre Erfahrungen.

Update Onkologie