Skip to main content
Erschienen in: Aesthetic Plastic Surgery 5/2018

22.05.2018 | Original Article

Three-Dimensional Imaging in Rhinoplasty: A Comparison of the Simulated versus Actual Result

verfasst von: Sarah Persing, Andrew Timberlake, Sarika Madari, Derek Steinbacher

Erschienen in: Aesthetic Plastic Surgery | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Computer imaging has become increasingly popular for rhinoplasty. Three-dimensional (3D) analysis permits a more comprehensive view from multiple vantage points. However, the predictability and concordance between the simulated and actual result have not been morphometrically studied. The purpose of this study was to aesthetically and quantitatively compare the simulated to actual rhinoplasty result.

Methods

A retrospective review of 3D images (VECTRA, Canfield) for rhinoplasty patients was performed. Images (preop, simulated, and actual) were randomized. A blinded panel of physicians rated the images (1 = poor, 5 = excellent). The image series considered “best” was also recorded. A quantitative assessment of nasolabial angle and tip projection was compared. Paired and two-sample t tests were performed for statistical analysis (P < 0.05 as significant).

Results

Forty patients were included. 67.5% of preoperative images were rated as poor (mean = 1.7). The simulation received a mean score of 2.9 (good in 60% of cases). 82.5% of actual cases were rated good to excellent (mean 3.4) (P < 0.001). Overall, the panel significantly preferred the actual postoperative result in 77.5% of cases compared to the simulation in 22.5% of cases (P < 0.001). The actual nasal tip was more projected compared to the simulations for both males and females. There was no significant difference in nasal tip rotation between simulated and postoperative groups.

Conclusion

3D simulation is a powerful communication and planning tool in rhinoplasty. In this study, the actual result was deemed more aesthetic than the simulated image. Surgeon experience is important to translate the plan and achieve favorable postoperative results.

Level of Evidence IV

This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.​springer.​com/​00266.
Literatur
1.
Zurück zum Zitat Lekakis G, Claes P, Hamilton G, Hellings P (2016) Evolution of preoperative rhinoplasty consult by computer imaging. Facial Plast Surg 32:80–87CrossRefPubMed Lekakis G, Claes P, Hamilton G, Hellings P (2016) Evolution of preoperative rhinoplasty consult by computer imaging. Facial Plast Surg 32:80–87CrossRefPubMed
3.
4.
Zurück zum Zitat Muhlbauer W, Holm C (2005) Computer imaging and surgical reality in aesthetic rhinoplasty. Plast Reconstr Surg 115:2104 Muhlbauer W, Holm C (2005) Computer imaging and surgical reality in aesthetic rhinoplasty. Plast Reconstr Surg 115:2104
5.
Zurück zum Zitat Toriumi D, Dixon T (2011) Assessment of rhinoplasty techniques by overlay of before-and-after 3D images. Facial Plast Surg Clin N Am 19:711–723CrossRef Toriumi D, Dixon T (2011) Assessment of rhinoplasty techniques by overlay of before-and-after 3D images. Facial Plast Surg Clin N Am 19:711–723CrossRef
6.
Zurück zum Zitat Mehta U, Mazhar K, Frankel A (2010) Accuracy of preoperative computer imaging in rhinoplasty. Arch Facial Plast Surg 12:394–398CrossRefPubMed Mehta U, Mazhar K, Frankel A (2010) Accuracy of preoperative computer imaging in rhinoplasty. Arch Facial Plast Surg 12:394–398CrossRefPubMed
7.
Zurück zum Zitat Adelson R, DeFatta R, Bassischis B (2008) Objective assessment of the accuracy of computer-simulated imaging in rhinoplasty. J Otolaryngol 29:151–155CrossRef Adelson R, DeFatta R, Bassischis B (2008) Objective assessment of the accuracy of computer-simulated imaging in rhinoplasty. J Otolaryngol 29:151–155CrossRef
8.
Zurück zum Zitat Bronz G (1994) Predictability of teh computer imaging system in primary rhinoplasty. Aesthetic Plast Surg 18:175–181CrossRefPubMed Bronz G (1994) Predictability of teh computer imaging system in primary rhinoplasty. Aesthetic Plast Surg 18:175–181CrossRefPubMed
9.
Zurück zum Zitat Sharp H, Tingay R, Coman S, Mills V, Roberts D (2002) Computer imaging and patient satisfaction in rhinoplasty surgery. J Laryngol Otol 116:1009–1013PubMed Sharp H, Tingay R, Coman S, Mills V, Roberts D (2002) Computer imaging and patient satisfaction in rhinoplasty surgery. J Laryngol Otol 116:1009–1013PubMed
10.
Zurück zum Zitat Sharp H, Rowe-Jones J (2003) Assessing outcome in aesthetic rhinoplasty. Clin Otolaryngol 28:430–435CrossRefPubMed Sharp H, Rowe-Jones J (2003) Assessing outcome in aesthetic rhinoplasty. Clin Otolaryngol 28:430–435CrossRefPubMed
Metadaten
Titel
Three-Dimensional Imaging in Rhinoplasty: A Comparison of the Simulated versus Actual Result
verfasst von
Sarah Persing
Andrew Timberlake
Sarika Madari
Derek Steinbacher
Publikationsdatum
22.05.2018
Verlag
Springer US
Erschienen in
Aesthetic Plastic Surgery / Ausgabe 5/2018
Print ISSN: 0364-216X
Elektronische ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-018-1151-9

Weitere Artikel der Ausgabe 5/2018

Aesthetic Plastic Surgery 5/2018 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.