Skip to main content
Erschienen in: Archives of Gynecology and Obstetrics 4/2007

01.10.2007 | Original Article

Three-dimensional ultrasound fetal urinary bladder volume measurement: reliability of rotational (VOCALTM) technique using different steps of rotation

verfasst von: F. M. Peixoto-Filho, R. A. M. Sá, L. M. Lopes, L. G. C. Velarde, E. Marchiori, Y. Ville

Erschienen in: Archives of Gynecology and Obstetrics | Ausgabe 4/2007

Einloggen, um Zugang zu erhalten

Abstract

Objective

The aim of the study was to investigate the inter- and intraobserver reliability in measuring the fetal bladder volume by 3d ultrasound imaging by VOCALTM. In addition a comparison of 15° and 30° rotation steps calculation had been performed.

Methods

Measurements (n = 240) of FB volume were performed in 30 low-risk patients with gestation times ranging from 22 to 39 weeks by two independent observers blind to each other. All fetuses were examined and no ultrasound detectable malformation was found. The volume for each FB was measured twice by the observers who used the Virtual Organ Computed-aided Analysis (VOCALTM) technique. Distinct sets of 12 and 6 planes were obtained after sequential rotations of 15° and 30°, respectively. The internal contour of fetal bladder was determined manually and carefully as to exclude adjacent structures from volume calculation. Wilcoxon signed-rank test was used for the comparison of paired samples in the cases of replication within and between observers. Spearman’s rank correlation was used to study the relationship among angles. Bland and Altman’s graphical approach was used to investigate the agreement between observers.

Results

Both techniques were shown to be highly reliable. No significant difference was found between the measurements of FB volume with the VOCALTM technique by varying either the steps of rotation or the observers.

Conclusion

Excellent correlations were found for both observers in the use of rotation angles of 15° and 30°. Since a significantly faster evaluation was obtained by using a 30° rotation step it must be preferred to assess the FB volume. Our results show that the VOCALTM technique, with a plane rotation of 30°, can be used in a simple way to estimate fetal urine production.
Literatur
1.
Zurück zum Zitat Campbell S, Wladmiroff JW, Dewhurst CJ (1973) The antenatal measurement of fetal urine production. J Obstet Gynecol Br Commonw 80:680–686 Campbell S, Wladmiroff JW, Dewhurst CJ (1973) The antenatal measurement of fetal urine production. J Obstet Gynecol Br Commonw 80:680–686
2.
Zurück zum Zitat Fägerquist M, Fägerquist U, Steyskal A, Odéns Blomberg (2003) Estimation of fetal urinary bladder volume using sum-of-cylinders modified vs. the ellipsoid formula Ultrasound Obstet Gynecol 22:67–73PubMedCrossRef Fägerquist M, Fägerquist U, Steyskal A, Odéns Blomberg (2003) Estimation of fetal urinary bladder volume using sum-of-cylinders modified vs. the ellipsoid formula Ultrasound Obstet Gynecol 22:67–73PubMedCrossRef
3.
Zurück zum Zitat Fägerquist M, Fägerquist U, Steyskal H, Odéns A, Blomberg SG (2002) Accuracy in estimating fetal urinary bladder volume using a modified ultrasound technique. Ultrasound Obstet Gynecol 19(4):371–379PubMedCrossRef Fägerquist M, Fägerquist U, Steyskal H, Odéns A, Blomberg SG (2002) Accuracy in estimating fetal urinary bladder volume using a modified ultrasound technique. Ultrasound Obstet Gynecol 19(4):371–379PubMedCrossRef
4.
Zurück zum Zitat Fägerquist M, Fägerquist U, Steyskal H, Odéns A, Blomberg SG (2001) Fetal urine production and accuracy when estimating fetal urinary bladder volume. Ultrasound Obstet Gynecol 17:132–139PubMedCrossRef Fägerquist M, Fägerquist U, Steyskal H, Odéns A, Blomberg SG (2001) Fetal urine production and accuracy when estimating fetal urinary bladder volume. Ultrasound Obstet Gynecol 17:132–139PubMedCrossRef
5.
Zurück zum Zitat Fok WY, Chan LY, Lau TK (2006) The influence of fetal position on amniotic fluid index and single deepest pocket. Ultrasound Obstet Gynecol 28:162–165PubMedCrossRef Fok WY, Chan LY, Lau TK (2006) The influence of fetal position on amniotic fluid index and single deepest pocket. Ultrasound Obstet Gynecol 28:162–165PubMedCrossRef
6.
Zurück zum Zitat Hendriana HL, Moore TR (1994) Ultrasonographic evaluation of human fetal urinary flow rate: accuracy limits of bladder volume estimations. Am J Obstet Gynecol 170:1250–1254 Hendriana HL, Moore TR (1994) Ultrasonographic evaluation of human fetal urinary flow rate: accuracy limits of bladder volume estimations. Am J Obstet Gynecol 170:1250–1254
7.
Zurück zum Zitat Kalache KD, Espinoza J, Chaiworapongsa T, Londono J, Schoen ML, Treadwell MC, Lee W, Romero R (2003) Three-dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique. Ultrasound Obstet Gynecol 21:111–118PubMedCrossRef Kalache KD, Espinoza J, Chaiworapongsa T, Londono J, Schoen ML, Treadwell MC, Lee W, Romero R (2003) Three-dimensional ultrasound fetal lung volume measurement: a systematic study comparing the multiplanar method with the rotational (VOCAL) technique. Ultrasound Obstet Gynecol 21:111–118PubMedCrossRef
8.
Zurück zum Zitat Kurjak A, Kirkinen P, Ivankovic D (1981) Ultrasonic assessment of fetal kidney function in normal and complicated pregnancies. Am J Obstet Gynecol 141:266–270PubMed Kurjak A, Kirkinen P, Ivankovic D (1981) Ultrasonic assessment of fetal kidney function in normal and complicated pregnancies. Am J Obstet Gynecol 141:266–270PubMed
9.
Zurück zum Zitat Magann EF, Chauhan SP, Barrilleaux FS, Whitworth NS, Martin JN Jr (2000) Amniotic Fluid index and single deepest pocket: weak indicators of abnormal amniotic volumes. Obstet Gynecol 96(5):737–740PubMedCrossRef Magann EF, Chauhan SP, Barrilleaux FS, Whitworth NS, Martin JN Jr (2000) Amniotic Fluid index and single deepest pocket: weak indicators of abnormal amniotic volumes. Obstet Gynecol 96(5):737–740PubMedCrossRef
10.
Zurück zum Zitat Martins WP, Ferriani RA, Barra DA, Dos Reis RM, Bortolieiro MAV, Nastri CO, Mauad-Filho F (2007) Reliability and validity of tissue volume measurement by three-dimensional ultrasound: an experimental model. Ultrasound Obstet Gynecol 29:210–214PubMedCrossRef Martins WP, Ferriani RA, Barra DA, Dos Reis RM, Bortolieiro MAV, Nastri CO, Mauad-Filho F (2007) Reliability and validity of tissue volume measurement by three-dimensional ultrasound: an experimental model. Ultrasound Obstet Gynecol 29:210–214PubMedCrossRef
11.
Zurück zum Zitat Nicolaides KH, Peters MT, Vyas S et al (1990) Relation of rate of urine production to oxygen tension in small-for-gestational age fetuses. Am J Obstet Gynecol 162(2):387–391PubMed Nicolaides KH, Peters MT, Vyas S et al (1990) Relation of rate of urine production to oxygen tension in small-for-gestational age fetuses. Am J Obstet Gynecol 162(2):387–391PubMed
12.
Zurück zum Zitat Ott WJ (2005) Reevaluation of the relationship between amniotic fluid volume and perinatal outcome. Am J Obstet Gynecol 192:1803–1809PubMedCrossRef Ott WJ (2005) Reevaluation of the relationship between amniotic fluid volume and perinatal outcome. Am J Obstet Gynecol 192:1803–1809PubMedCrossRef
13.
Zurück zum Zitat Raine-Fenning NJ, Clewes JS, Kendall NR et al (2003) The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting. Ultrasound Obstet Gynecol 21:283–291PubMedCrossRef Raine-Fenning NJ, Clewes JS, Kendall NR et al (2003) The interobserver reliability and validity of volume calculation from three-dimensional ultrasound datasets in the in vitro setting. Ultrasound Obstet Gynecol 21:283–291PubMedCrossRef
14.
Zurück zum Zitat Riccabona M, Nelson TR, Pretorius DH, Davidson TE (1995) Distance and Volume measurement using three-dimension ultrasonography. J Ultrasound Med 14(12):881–886PubMed Riccabona M, Nelson TR, Pretorius DH, Davidson TE (1995) Distance and Volume measurement using three-dimension ultrasonography. J Ultrasound Med 14(12):881–886PubMed
15.
Zurück zum Zitat Ruano R, Martinovic J, Dommergues M, Aubry MC, Dumez Y, Benachi A (2005) Accuracy of fetal lung volume assessed by three-dimensional sonography. Ultrasound Obstet Gynecol 26:725–730PubMedCrossRef Ruano R, Martinovic J, Dommergues M, Aubry MC, Dumez Y, Benachi A (2005) Accuracy of fetal lung volume assessed by three-dimensional sonography. Ultrasound Obstet Gynecol 26:725–730PubMedCrossRef
16.
Zurück zum Zitat Schrimmer DB, Moore TR (2002) Sonographic evaluation of amniotic fluid volume. Clinical Obstet Gynecol 45(4):1026–1038CrossRef Schrimmer DB, Moore TR (2002) Sonographic evaluation of amniotic fluid volume. Clinical Obstet Gynecol 45(4):1026–1038CrossRef
17.
Zurück zum Zitat Stiger RH, Mulder EJ, Visser GH (1998) Hourly fetal urine production rate in the near-term fetus: is it really increased during fetal quiet sleep? Early Hum Dev 50(3):263–272CrossRef Stiger RH, Mulder EJ, Visser GH (1998) Hourly fetal urine production rate in the near-term fetus: is it really increased during fetal quiet sleep? Early Hum Dev 50(3):263–272CrossRef
18.
Zurück zum Zitat Vanderheyden T, Sailesh K, Nicholas MF (2003) Fetal renal impairment. Seminars Neonatol 8:279–89CrossRef Vanderheyden T, Sailesh K, Nicholas MF (2003) Fetal renal impairment. Seminars Neonatol 8:279–89CrossRef
19.
Zurück zum Zitat Wegrzyn P, Faro C, Falcon O, Peralta CFA, Nicolaides KH (2006) Placental volume in twin and triplet pregnancies measured by three-dimensional ultrasound at 11 + 0 to 13 + 6 weeks of gestation. Ultrasound Obstet Gynecol 27:647–651PubMedCrossRef Wegrzyn P, Faro C, Falcon O, Peralta CFA, Nicolaides KH (2006) Placental volume in twin and triplet pregnancies measured by three-dimensional ultrasound at 11 + 0 to 13 + 6 weeks of gestation. Ultrasound Obstet Gynecol 27:647–651PubMedCrossRef
20.
Zurück zum Zitat Wladmiroff JW, Campbell S (1974) Fetal urine production rates in normal and complicated pregnancy. Lancet 1:151–154CrossRef Wladmiroff JW, Campbell S (1974) Fetal urine production rates in normal and complicated pregnancy. Lancet 1:151–154CrossRef
Metadaten
Titel
Three-dimensional ultrasound fetal urinary bladder volume measurement: reliability of rotational (VOCALTM) technique using different steps of rotation
verfasst von
F. M. Peixoto-Filho
R. A. M. Sá
L. M. Lopes
L. G. C. Velarde
E. Marchiori
Y. Ville
Publikationsdatum
01.10.2007
Verlag
Springer-Verlag
Erschienen in
Archives of Gynecology and Obstetrics / Ausgabe 4/2007
Print ISSN: 0932-0067
Elektronische ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-007-0360-2

Weitere Artikel der Ausgabe 4/2007

Archives of Gynecology and Obstetrics 4/2007 Zur Ausgabe

Antikörper-Wirkstoff-Konjugat hält solide Tumoren in Schach

16.05.2024 Zielgerichtete Therapie Nachrichten

Trastuzumab deruxtecan scheint auch jenseits von Lungenkrebs gut gegen solide Tumoren mit HER2-Mutationen zu wirken. Dafür sprechen die Daten einer offenen Pan-Tumor-Studie.

Mammakarzinom: Senken Statine das krebsbedingte Sterberisiko?

15.05.2024 Mammakarzinom Nachrichten

Frauen mit lokalem oder metastasiertem Brustkrebs, die Statine einnehmen, haben eine niedrigere krebsspezifische Mortalität als Patientinnen, die dies nicht tun, legen neue Daten aus den USA nahe.

S3-Leitlinie zur unkomplizierten Zystitis: Auf Antibiotika verzichten?

15.05.2024 Harnwegsinfektionen Nachrichten

Welche Antibiotika darf man bei unkomplizierter Zystitis verwenden und wovon sollte man die Finger lassen? Welche pflanzlichen Präparate können helfen? Was taugt der zugelassene Impfstoff? Antworten vom Koordinator der frisch überarbeiteten S3-Leitlinie, Prof. Florian Wagenlehner.

Gestationsdiabetes: In der zweiten Schwangerschaft folgenreicher als in der ersten

13.05.2024 Gestationsdiabetes Nachrichten

Das Risiko, nach einem Gestationsdiabetes einen Typ-2-Diabetes zu entwickeln, hängt nicht nur von der Zahl, sondern auch von der Reihenfolge der betroffenen Schwangerschaften ab.

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.