Skip to main content
Erschienen in: Journal of Bone and Mineral Metabolism 4/2017

09.12.2016 | Original Article

Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density

verfasst von: Luke Arentsen, Karen E. Hansen, Masashi Yagi, Yutaka Takahashi, Ryan Shanley, Angela McArthur, Patrick Bolan, Taiki Magome, Douglas Yee, Jerry Froelich, Susanta K. Hui

Erschienen in: Journal of Bone and Mineral Metabolism | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

Temporal and spatial variations in bone marrow adipose tissue (MAT) can be indicative of several pathologies and confound current methods of assessing immediate changes in bone mineral remodeling. We present a novel dual-energy computed tomography (DECT) method to monitor MAT and marrow-corrected volumetric BMD (mcvBMD) throughout the body. Twenty-three cancellous skeletal sites in 20 adult female cadavers aged 40–80 years old were measured using DECT (80 and 140 kVp). vBMD was simultaneous recorded using QCT. MAT was further sampled using MRI. Thirteen lumbar vertebrae were then excised from the MRI-imaged donors and examined by microCT. After MAT correction throughout the skeleton, significant differences (p < 0.05) were found between QCT-derived vBMD and DECT-derived mcvBMD results. McvBMD was highly heterogeneous with a maximum at the posterior skull and minimum in the proximal humerus (574 and 0.7 mg/cc, respectively). BV/TV and BMC have a nearly significant correlation with mcvBMD (r = 0.545, p = 0.057 and r = 0.539, p = 0.061, respectively). MAT assessed by DECT showed a significant correlation with MRI MAT results (r = 0.881, p < 0.0001). Both DECT- and MRI-derived MAT had a significant influence on uncorrected vBMD (r = −0.86 and r = −0.818, p ≤ 0.0001, respectively). Conversely, mcvBMD had no correlation with DECT- or MRI-derived MAT (r = 0.261 and r = 0.067). DECT can be used to assess MAT while simultaneously collecting mcvBMD values at each skeletal site. MAT is heterogeneous throughout the skeleton, highly variable, and should be accounted for in longitudinal mcvBMD studies. McvBMD accurately reflects the calcified tissue in cancellous bone.
Literatur
1.
Zurück zum Zitat Hui SK, Fairchild GR, Kidder LS, Sharma M, Bhattacharya M, Jackson S, Le C, Petryk A, Islam MS, Yee D (2013) The influence of therapeutic radiation on the patterns of bone remodeling in ovary-intact and ovariectomized mice. Calcif Tissue Int 92:372–384CrossRefPubMedPubMedCentral Hui SK, Fairchild GR, Kidder LS, Sharma M, Bhattacharya M, Jackson S, Le C, Petryk A, Islam MS, Yee D (2013) The influence of therapeutic radiation on the patterns of bone remodeling in ovary-intact and ovariectomized mice. Calcif Tissue Int 92:372–384CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Yagi M, Arentsen L, Shanley RM, Rosen CJ, Kidder LS, Sharkey LC, Yee D, Koizumi M, Ogawa K, Hui SK (2014) A dual-radioisotope hybrid whole-body micro-positron emission tomography/ computed tomography system reveals functional heterogeneity and early local and systemic changes following targeted radiation to the murine caudal skeleton. Calcif Tissue Int 94:544–552CrossRefPubMedPubMedCentral Yagi M, Arentsen L, Shanley RM, Rosen CJ, Kidder LS, Sharkey LC, Yee D, Koizumi M, Ogawa K, Hui SK (2014) A dual-radioisotope hybrid whole-body micro-positron emission tomography/ computed tomography system reveals functional heterogeneity and early local and systemic changes following targeted radiation to the murine caudal skeleton. Calcif Tissue Int 94:544–552CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Frost ML, Fogelman I, Blake GM, Marsden PK, Cook G Jr (2004) Dissociation between global markers of bone formation and direct measurement of spinal bone formation in osteoporosis. J Bone Miner Res 19:1797–1804CrossRefPubMed Frost ML, Fogelman I, Blake GM, Marsden PK, Cook G Jr (2004) Dissociation between global markers of bone formation and direct measurement of spinal bone formation in osteoporosis. J Bone Miner Res 19:1797–1804CrossRefPubMed
4.
Zurück zum Zitat Mitchell MJ, Logan PM (1998) Radiation-induced changes in bone. Radiographics 18:1125–1136 (quiz 1242–3) CrossRefPubMed Mitchell MJ, Logan PM (1998) Radiation-induced changes in bone. Radiographics 18:1125–1136 (quiz 1242–3) CrossRefPubMed
5.
Zurück zum Zitat Bolotin HH, Sievanen H, Grashuis JL, Kuiper JW, Jarvinen TL (2001) Inaccuracies inherent in patient-specific dual-energy X-ray absorptiometry bone mineral density measurements: comprehensive phantom-based evaluation. J Bone Miner Res 16:417–426CrossRefPubMed Bolotin HH, Sievanen H, Grashuis JL, Kuiper JW, Jarvinen TL (2001) Inaccuracies inherent in patient-specific dual-energy X-ray absorptiometry bone mineral density measurements: comprehensive phantom-based evaluation. J Bone Miner Res 16:417–426CrossRefPubMed
6.
Zurück zum Zitat Yu EW, Thomas BJ, Brown JK, Finkelstein JS (2012) Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT. J Bone Miner Res 27:119–124CrossRefPubMed Yu EW, Thomas BJ, Brown JK, Finkelstein JS (2012) Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT. J Bone Miner Res 27:119–124CrossRefPubMed
7.
8.
Zurück zum Zitat Scheller EL, Doucette CR, Learman BS, Cawthorn WP, Khandaker S, Schell B, Wu B, Ding SY, Bredella MA, Fazeli PK, Khoury B, Jepsen KJ, Pilch PF, Klibanski A, Rosen CJ, MacDougald OA (2015) Region-specific variation in the properties of skeletal adipocytes reveals regulated and constitutive marrow adipose tissues. Nat Commun 6:7808CrossRefPubMedPubMedCentral Scheller EL, Doucette CR, Learman BS, Cawthorn WP, Khandaker S, Schell B, Wu B, Ding SY, Bredella MA, Fazeli PK, Khoury B, Jepsen KJ, Pilch PF, Klibanski A, Rosen CJ, MacDougald OA (2015) Region-specific variation in the properties of skeletal adipocytes reveals regulated and constitutive marrow adipose tissues. Nat Commun 6:7808CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Mazess RB (1983) Errors in measuring trabecular bone by computed tomography due to marrow and bone composition. Calcif Tissue Int 35:148–152CrossRefPubMed Mazess RB (1983) Errors in measuring trabecular bone by computed tomography due to marrow and bone composition. Calcif Tissue Int 35:148–152CrossRefPubMed
10.
Zurück zum Zitat Kuiper JW, van Kuijk C, Grashuis JL, Ederveen AG, Schutte HE (1996) Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro. Osteoporos Int 6:25–30CrossRefPubMed Kuiper JW, van Kuijk C, Grashuis JL, Ederveen AG, Schutte HE (1996) Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro. Osteoporos Int 6:25–30CrossRefPubMed
11.
Zurück zum Zitat Gluer CC, Genant HK (1989) Impact of marrow fat on accuracy of quantitative CT. J Comput Assist Tomogr 13:1023–1035CrossRefPubMed Gluer CC, Genant HK (1989) Impact of marrow fat on accuracy of quantitative CT. J Comput Assist Tomogr 13:1023–1035CrossRefPubMed
12.
Zurück zum Zitat Rosen CJ, Ackert-Bicknell C, Rodriguez JP, Pino AM (2009) Marrow fat and the bone microenvironment: developmental, functional, and pathological implications. Crit Rev Eukaryot Gene Expr 19:109–124CrossRefPubMedPubMedCentral Rosen CJ, Ackert-Bicknell C, Rodriguez JP, Pino AM (2009) Marrow fat and the bone microenvironment: developmental, functional, and pathological implications. Crit Rev Eukaryot Gene Expr 19:109–124CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Arentsen L, Yagi M, Takahashi Y, Bolan PJ, White M, Yee D, Hui S (2015) Validation of marrow fat assessment using noninvasive imaging with histologic examination of human bone samples. Bone 72:118–122CrossRefPubMed Arentsen L, Yagi M, Takahashi Y, Bolan PJ, White M, Yee D, Hui S (2015) Validation of marrow fat assessment using noninvasive imaging with histologic examination of human bone samples. Bone 72:118–122CrossRefPubMed
14.
Zurück zum Zitat Hui SK, Arentsen L, Sueblinvong T, Brown K, Bolan et al (2015) A phase I feasibility study of multi-modality imaging assessing rapid expansion of marrow fat and decreased bone mineral density in cancer patients. Bone 73:90–97CrossRefPubMed Hui SK, Arentsen L, Sueblinvong T, Brown K, Bolan et al (2015) A phase I feasibility study of multi-modality imaging assessing rapid expansion of marrow fat and decreased bone mineral density in cancer patients. Bone 73:90–97CrossRefPubMed
15.
Zurück zum Zitat Graser A, Johnson TR, Bader M, Staehler M, Haseke N, Nikolaou K, Reiser MF, Stief CG, Becker CR (2008) Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol 43:112–119CrossRefPubMed Graser A, Johnson TR, Bader M, Staehler M, Haseke N, Nikolaou K, Reiser MF, Stief CG, Becker CR (2008) Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol 43:112–119CrossRefPubMed
16.
Zurück zum Zitat Christner JA, Kofler JM, McCollough CH (2010) Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol 194:881–889CrossRefPubMed Christner JA, Kofler JM, McCollough CH (2010) Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol 194:881–889CrossRefPubMed
17.
Zurück zum Zitat Hui SK, Arentsen L, Wilcox A, Shanley R, Yee D, Ghebre R (2015) Spatial and temporal fracture pattern in breast and gynecologic cancer survivors. J Cancer 6:66–69CrossRefPubMedPubMedCentral Hui SK, Arentsen L, Wilcox A, Shanley R, Yee D, Ghebre R (2015) Spatial and temporal fracture pattern in breast and gynecologic cancer survivors. J Cancer 6:66–69CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Berger MJ, Hubbell JH, Seltzer SM, Chang J, Coursey JS, Sukumar R, Zucker DS (1998) XCOM: photon cross section database. NIST Stand Ref Database 8:87–3597 Berger MJ, Hubbell JH, Seltzer SM, Chang J, Coursey JS, Sukumar R, Zucker DS (1998) XCOM: photon cross section database. NIST Stand Ref Database 8:87–3597
19.
Zurück zum Zitat Goodsitt MM, Hoover P, Veldee MS, Hsueh SL (1994) The composition of bone marrow for a dual-energy quantitative computed tomography technique. A cadaver and computer simulation study. Invest Radiol 29:695–704CrossRefPubMed Goodsitt MM, Hoover P, Veldee MS, Hsueh SL (1994) The composition of bone marrow for a dual-energy quantitative computed tomography technique. A cadaver and computer simulation study. Invest Radiol 29:695–704CrossRefPubMed
20.
Zurück zum Zitat Johnson TR, Krauss B, Sedlmair M, Grasruck M, Bruder H, Morhard D, Fink C, Weckbach S, Lenhard M, Schmidt B, Flohr T, Reiser MF, Becker CR (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517CrossRefPubMed Johnson TR, Krauss B, Sedlmair M, Grasruck M, Bruder H, Morhard D, Fink C, Weckbach S, Lenhard M, Schmidt B, Flohr T, Reiser MF, Becker CR (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517CrossRefPubMed
21.
Zurück zum Zitat ICRU (1992) Photon, electron, proton and neutron interaction data for body tissues. (Bethesda, MD: International commission on radiation units and measurements) ICRU Report 46 ICRU (1992) Photon, electron, proton and neutron interaction data for body tissues. (Bethesda, MD: International commission on radiation units and measurements) ICRU Report 46
22.
Zurück zum Zitat Bolan PJ, Arentsen L, Sueblinvong T, Zhang Y, Moeller S, Carter JS, Downs LS, Ghebre R, Yee D, Froelich J, Hui S (2013) Water-fat MRI for assessing changes in bone marrow composition due to radiation and chemotherapy in gynecologic cancer patients. J Magn Reson Imaging 38:1578–1584CrossRefPubMed Bolan PJ, Arentsen L, Sueblinvong T, Zhang Y, Moeller S, Carter JS, Downs LS, Ghebre R, Yee D, Froelich J, Hui S (2013) Water-fat MRI for assessing changes in bone marrow composition due to radiation and chemotherapy in gynecologic cancer patients. J Magn Reson Imaging 38:1578–1584CrossRefPubMed
23.
Zurück zum Zitat Berglund J, Johansson L, Ahlstrom H, Kullberg J (2010) Three-point Dixon method enables whole-body water and fat imaging of obese subjects. Magn Reson Med 63:1659–1668CrossRefPubMed Berglund J, Johansson L, Ahlstrom H, Kullberg J (2010) Three-point Dixon method enables whole-body water and fat imaging of obese subjects. Magn Reson Med 63:1659–1668CrossRefPubMed
24.
Zurück zum Zitat Hu HH, Bornert P, Hernando D, Kellman P, Ma J, Reeder S, Sirlin C (2012) ISMRM workshop on fat-water separation: insights, applications and progress in MRI. Magn Reson Med 68:378–388CrossRefPubMedPubMedCentral Hu HH, Bornert P, Hernando D, Kellman P, Ma J, Reeder S, Sirlin C (2012) ISMRM workshop on fat-water separation: insights, applications and progress in MRI. Magn Reson Med 68:378–388CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Hamilton G, Yokoo T, Bydder M, Cruite I, Schroeder ME, Sirlin CB, Middleton MS (2011) In vivo characterization of the liver fat (1)H MR spectrum. NMR Biomed 24:784–790CrossRefPubMed Hamilton G, Yokoo T, Bydder M, Cruite I, Schroeder ME, Sirlin CB, Middleton MS (2011) In vivo characterization of the liver fat (1)H MR spectrum. NMR Biomed 24:784–790CrossRefPubMed
26.
Zurück zum Zitat Doube M, Klosowski MM, Arganda-Carreras I, Cordelieres FP, Dougherty RP, Jackson JS, Schmid B, Hutchinson JR, Shefelbine SJ (2010) BoneJ: free and extensible bone image analysis in ImageJ. Bone 47:1076–1079CrossRefPubMedPubMedCentral Doube M, Klosowski MM, Arganda-Carreras I, Cordelieres FP, Dougherty RP, Jackson JS, Schmid B, Hutchinson JR, Shefelbine SJ (2010) BoneJ: free and extensible bone image analysis in ImageJ. Bone 47:1076–1079CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat National Rasband WS (1997–2011) ImageJ. In: U.S. National Institutes of Health, Bethesda National Rasband WS (1997–2011) ImageJ. In: U.S. National Institutes of Health, Bethesda
28.
Zurück zum Zitat Muller R, Hildebrand T, Hauselmann HJ, Ruegsegger P (1996) In vivo reproducibility of three-dimensional structural properties of noninvasive bone biopsies using 3D-pQCT. J Bone Miner Res 11:1745–1750CrossRefPubMed Muller R, Hildebrand T, Hauselmann HJ, Ruegsegger P (1996) In vivo reproducibility of three-dimensional structural properties of noninvasive bone biopsies using 3D-pQCT. J Bone Miner Res 11:1745–1750CrossRefPubMed
29.
Zurück zum Zitat Hazrati Marangalou J, Eckstein F, Kuhn V, Ito K, Cataldi M, Taddei F, van Rietbergen B (2014) Locally measured microstructural parameters are better associated with vertebral strength than whole bone density. Osteoporos Int 25:1285–1296CrossRefPubMed Hazrati Marangalou J, Eckstein F, Kuhn V, Ito K, Cataldi M, Taddei F, van Rietbergen B (2014) Locally measured microstructural parameters are better associated with vertebral strength than whole bone density. Osteoporos Int 25:1285–1296CrossRefPubMed
30.
Zurück zum Zitat Altuncu E, Akman I, Yurdakul Z, Ozdogan T, Solakoglu M, Selim N, Bilgen H, Ozek E, Bereket A (2007) Quantitative ultrasound and biochemical parameters for the assessment of osteopenia in preterm infants. J Matern Fetal Neonatal Med 20:401–405CrossRefPubMed Altuncu E, Akman I, Yurdakul Z, Ozdogan T, Solakoglu M, Selim N, Bilgen H, Ozek E, Bereket A (2007) Quantitative ultrasound and biochemical parameters for the assessment of osteopenia in preterm infants. J Matern Fetal Neonatal Med 20:401–405CrossRefPubMed
31.
Zurück zum Zitat Poole KES (2009) Changing structure of the femoral neck across the adult female lifespan. J Bone Miner Res 25:482–491CrossRef Poole KES (2009) Changing structure of the femoral neck across the adult female lifespan. J Bone Miner Res 25:482–491CrossRef
32.
Zurück zum Zitat Dall’Ara E, Varga P, Pahr D, Zysset P (2011) A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images. Med Phys 38:2602–2608CrossRefPubMed Dall’Ara E, Varga P, Pahr D, Zysset P (2011) A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images. Med Phys 38:2602–2608CrossRefPubMed
33.
Zurück zum Zitat Bergmann P, Paternot T, Schoutens A (1983) Regional measurement of bone calcium accretion rate and exchangeable pool with a whole-body counter: method and studies in subjects without bone disease. Calcif Tissue Int 35:21–28CrossRefPubMed Bergmann P, Paternot T, Schoutens A (1983) Regional measurement of bone calcium accretion rate and exchangeable pool with a whole-body counter: method and studies in subjects without bone disease. Calcif Tissue Int 35:21–28CrossRefPubMed
34.
Zurück zum Zitat Liu X, Yu L, Primak AN, McCollough CH (2009) Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition. Med Phys 36:1602–1609CrossRefPubMedPubMedCentral Liu X, Yu L, Primak AN, McCollough CH (2009) Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition. Med Phys 36:1602–1609CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat Hui SK, Arentsen L, Sueblinvong T, Brown K, Bolan et al (2014) A phase I feasibility study of multi-modality imaging assessing rapid expansion of marrow fat and decreased bone mineral density in cancer patients. Bone 73C:90–97 Hui SK, Arentsen L, Sueblinvong T, Brown K, Bolan et al (2014) A phase I feasibility study of multi-modality imaging assessing rapid expansion of marrow fat and decreased bone mineral density in cancer patients. Bone 73C:90–97
36.
Zurück zum Zitat Veres C, Allodji RS, Llanas D, Vu Bezin J, Chavaudra J, Mege JP, Lefkopoulos D, Quiniou E, Deutsh E, de Vathaire F, Diallo I (2014) Retrospective reconstructions of active bone marrow dose-volume histograms. Int J Radiat Oncol Biol Phys 90:1216–1224CrossRefPubMed Veres C, Allodji RS, Llanas D, Vu Bezin J, Chavaudra J, Mege JP, Lefkopoulos D, Quiniou E, Deutsh E, de Vathaire F, Diallo I (2014) Retrospective reconstructions of active bone marrow dose-volume histograms. Int J Radiat Oncol Biol Phys 90:1216–1224CrossRefPubMed
37.
38.
Zurück zum Zitat Kerl JM, Bauer RW, Maurer TB, Aschenbach R, Korkusuz H, Lehnert T, Deseive S, Ackermann H, Vogl TJ (2011) Dose levels at coronary CT angiography—a comparison of Dual Energy-, Dual Source- and 16-slice CT. Eur Radiol 21:530–537CrossRefPubMed Kerl JM, Bauer RW, Maurer TB, Aschenbach R, Korkusuz H, Lehnert T, Deseive S, Ackermann H, Vogl TJ (2011) Dose levels at coronary CT angiography—a comparison of Dual Energy-, Dual Source- and 16-slice CT. Eur Radiol 21:530–537CrossRefPubMed
39.
Zurück zum Zitat Noh J, Fessler JA, Kinahan PE (2009) Statistical sinogram restoration in dual-energy CT for PET attenuation correction. IEEE Trans Med Imaging 28:1688–1702CrossRefPubMedPubMedCentral Noh J, Fessler JA, Kinahan PE (2009) Statistical sinogram restoration in dual-energy CT for PET attenuation correction. IEEE Trans Med Imaging 28:1688–1702CrossRefPubMedPubMedCentral
Metadaten
Titel
Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density
verfasst von
Luke Arentsen
Karen E. Hansen
Masashi Yagi
Yutaka Takahashi
Ryan Shanley
Angela McArthur
Patrick Bolan
Taiki Magome
Douglas Yee
Jerry Froelich
Susanta K. Hui
Publikationsdatum
09.12.2016
Verlag
Springer Japan
Erschienen in
Journal of Bone and Mineral Metabolism / Ausgabe 4/2017
Print ISSN: 0914-8779
Elektronische ISSN: 1435-5604
DOI
https://doi.org/10.1007/s00774-016-0796-1

Weitere Artikel der Ausgabe 4/2017

Journal of Bone and Mineral Metabolism 4/2017 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Reizdarmsyndrom: Diäten wirksamer als Medikamente

29.04.2024 Reizdarmsyndrom Nachrichten

Bei Reizdarmsyndrom scheinen Diäten, wie etwa die FODMAP-arme oder die kohlenhydratreduzierte Ernährung, effektiver als eine medikamentöse Therapie zu sein. Das hat eine Studie aus Schweden ergeben, die die drei Therapieoptionen im direkten Vergleich analysierte.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Update Innere Medizin