Skip to main content
Erschienen in: European Journal of Applied Physiology 5/2011

01.05.2011 | Short Communication

Validation of the SenseWear Armband at high intensity exercise

verfasst von: Clemens Drenowatz, Joey C. Eisenmann

Erschienen in: European Journal of Applied Physiology | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

The SenseWear Armband (SWA) has been shown to be a valid and practical tool to assess energy expenditure during habitual physical activity. However, previous studies have focused on low-to-moderate intensity activities. The purpose of this study was to assess the validity of the SWA during high intensity exercise. Twenty (ten males, ten females) endurance trained subjects, 24.3 (±2.8) years of age, performed three 10-min treadmill runs at 65, 75, and 85% of their VO2max each and also ran outside for 30 min at their preferred speed. Energy expenditure was measured with the SWA (software version 6.1) and a portable indirect calorimetry system (Jaeger Oxycon Mobile®). The SWA showed a ceiling effect around an intensity of ten METs. Since all subjects exceeded that intensity range during the exercise trials, the SWA significantly underestimated energy expenditure at high intensities. The intra-individual correlations between MET values calculated by the SWA and values derived from the Oxycon, however, were significant for all but two subjects (r = 0.390–0.933, mean = 0.66 ± 0.25). While providing accurate results for energy expenditure during low-to-moderate intensity physical activities, the SWA does not provide accurate estimates of energy expenditure at high intensity levels. The threshold for accurate measurements seems to be around an intensity of ten METs.
Literatur
Zurück zum Zitat Ainslie P, Reilly T, Westerterp K (2003) Estimating human energy expenditure: a review of techniques with particular reference to doubly labelled water. Sports Med 33(9):683–698PubMedCrossRef Ainslie P, Reilly T, Westerterp K (2003) Estimating human energy expenditure: a review of techniques with particular reference to doubly labelled water. Sports Med 33(9):683–698PubMedCrossRef
Zurück zum Zitat Beashel P, Taylor J (eds) (1996) Advanced studies in physical education and sports. Nelson Thornes, Cheltenham Beashel P, Taylor J (eds) (1996) Advanced studies in physical education and sports. Nelson Thornes, Cheltenham
Zurück zum Zitat Calabró MA, Welk GJ, Eisenmann JC (2009) Validation of the SenseWear Pro Armband algorithms in children. Med Sci Sports Exerc 41:1714–1720PubMedCrossRef Calabró MA, Welk GJ, Eisenmann JC (2009) Validation of the SenseWear Pro Armband algorithms in children. Med Sci Sports Exerc 41:1714–1720PubMedCrossRef
Zurück zum Zitat Corder K, Brage S, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef Corder K, Brage S, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef
Zurück zum Zitat Foss Ø, Hallén J (2005) Validity and stability of a computerized metabolic system with mixing chamber. Int J Sports Med 26(7):569–575PubMedCrossRef Foss Ø, Hallén J (2005) Validity and stability of a computerized metabolic system with mixing chamber. Int J Sports Med 26(7):569–575PubMedCrossRef
Zurück zum Zitat Fruin ML, Rankin JW (2004) Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc 36(6):1063–1069PubMedCrossRef Fruin ML, Rankin JW (2004) Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc 36(6):1063–1069PubMedCrossRef
Zurück zum Zitat King GA, Torres N, Potter C, Brooks TJ, Coleman KJ (2004) Comparison of activity monitors to estimate energy cost of treadmill exercise. Med Sci Sports Exerc 36(7):1244–1251PubMedCrossRef King GA, Torres N, Potter C, Brooks TJ, Coleman KJ (2004) Comparison of activity monitors to estimate energy cost of treadmill exercise. Med Sci Sports Exerc 36(7):1244–1251PubMedCrossRef
Zurück zum Zitat Koehler K, deMarees M, Braun H, Schaenzer W (2010) Comparison of two portable devices for assessing energy expenditure during high-intensity running. Med Sci Sports Exerc 42(5 Suppl): S304–S305 Koehler K, deMarees M, Braun H, Schaenzer W (2010) Comparison of two portable devices for assessing energy expenditure during high-intensity running. Med Sci Sports Exerc 42(5 Suppl): S304–S305
Zurück zum Zitat Malavolti M, Pietrobelli A, Dugoni M, Poli M, Romagnoli E, De Cristofaro P, Battistini NC (2007) A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr Metab Cardiovasc Dis 17(5):338–343PubMedCrossRef Malavolti M, Pietrobelli A, Dugoni M, Poli M, Romagnoli E, De Cristofaro P, Battistini NC (2007) A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr Metab Cardiovasc Dis 17(5):338–343PubMedCrossRef
Zurück zum Zitat Malina RM (1995) Anthropometry. In: Maud PJ, Foster C (eds) Physiological assessment of human fitness. Human Kinetics, Champaign Malina RM (1995) Anthropometry. In: Maud PJ, Foster C (eds) Physiological assessment of human fitness. Human Kinetics, Champaign
Zurück zum Zitat St-Onge M, Mignault D, Allison DB, Rabasa-Lhoret R (2007) Evaluation of a portable device to measure daily energy expenditure in free-living adults. Am J Clin Nutr 85:742–749PubMed St-Onge M, Mignault D, Allison DB, Rabasa-Lhoret R (2007) Evaluation of a portable device to measure daily energy expenditure in free-living adults. Am J Clin Nutr 85:742–749PubMed
Zurück zum Zitat Troiano RP (2005) A timely meeting: objective measurement of physical activity. Med Sci Sports Exerc 37(11):S487–S489PubMedCrossRef Troiano RP (2005) A timely meeting: objective measurement of physical activity. Med Sci Sports Exerc 37(11):S487–S489PubMedCrossRef
Zurück zum Zitat Welk GJ, Corbin CB, Dale D (2000) Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 71(2 Suppl):S59–S73PubMed Welk GJ, Corbin CB, Dale D (2000) Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 71(2 Suppl):S59–S73PubMed
Metadaten
Titel
Validation of the SenseWear Armband at high intensity exercise
verfasst von
Clemens Drenowatz
Joey C. Eisenmann
Publikationsdatum
01.05.2011
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 5/2011
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1695-0

Weitere Artikel der Ausgabe 5/2011

European Journal of Applied Physiology 5/2011 Zur Ausgabe

Neu im Fachgebiet Arbeitsmedizin

Elterliches Belastungserleben, Unaufmerksamkeits‑/Hyperaktivitätssymptome und elternberichtete ADHS bei Kindern und Jugendlichen: Ergebnisse aus der KiGGS-Studie

Open Access ADHS Leitthema

Die Aufmerksamkeitsdefizit‑/Hyperaktivitätsstörung (ADHS) ist eine der häufigsten psychischen Störungen im Kindes- und Jugendalter [ 1 ]. In Deutschland beträgt die Prävalenz einer elternberichteten ADHS-Diagnose bei Kindern und Jugendlichen 4,4 % …

Substanzkonsum und Nutzung von sozialen Medien, Computerspielen und Glücksspielen unter Auszubildenden an beruflichen Schulen

Open Access Leitthema

Die Begrenzung von Schäden durch Substanzkonsum und andere abhängige Verhaltensweisen von Jugendlichen und jungen Erwachsenen ist ein wichtiges Anliegen der öffentlichen Gesundheit. Der Übergang von der Adoleszenz zum jungen Erwachsenenalter ist …

Berufsbelastung und Stressbewältigung von weiblichen und männlichen Auszubildenden

Leitthema

In der Öffentlichkeit wird die berufliche Ausbildung oftmals unter ökonomischen Gesichtspunkten diskutiert: Mit den geburtenstarken Jahrgängen gehen erfahrene Fachkräfte in Rente und von nachfolgenden Generationen rücken zu wenige Arbeitskräfte …

Rauschtrinken in der frühen Adoleszenz

COVID-19 Leitthema

Alkohol ist in Deutschland die mit Abstand am häufigsten konsumierte psychoaktive Substanz. Mehr als 2 Drittel aller Erwachsenen im Alter von 18 bis 64 Jahren (70,5 %) hat 2021 in den letzten 30 Tagen Alkohol konsumiert [ 1 ]. Von diesen …