Skip to main content
Erschienen in: European Journal of Applied Physiology 3/2012

01.03.2012 | Short Communication

Validation of the Sensewear Armband during recreational in-line skating

verfasst von: Maroje Soric, Pavle Mikulic, Marjeta Misigoj-Durakovic, Lana Ruzic, Goran Markovic

Erschienen in: European Journal of Applied Physiology | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Multi-sensor body monitors that combine accelerometry with other physiological data are designed to overcome drawbacks of accelerometers in assessing activities with little or no vertical movement. One of such devices is the Sensewear Armband (SWA) which has been extensively validated during various activities. However, very few of the validation studies included activities other than walking and running. The aim of this investigation was to assess the validity of the SWA during recreational in-line skating. Nineteen participants (11 females and 8 males), 28 (±6) years of age, performed in-line skating exercise on a circular track at a self-selected pace. Energy expenditure was measured with the SWA and the Cosmed K4b2 breath-by-breath portable metabolic unit. The mean (SD) energy expenditure during in-line skating estimated by the SWA [25.5 (5.8) kJ/min] was significantly lower compared with indirect calorimetry [44.2 (9.7) kJ/min, P < 0.001]. Similarly, the mean (SD) MET values recorded by the SWA were also lower compared with IC [5.3 (1.0) METs vs. 9.1 (1.6) METs, P < 0.001]. The ratio limits of agreement suggest that in 95% of cases the SWA will underestimate the energy expenditure and MET values during in-line skating by as much as 24–56% compared with indirect calorimetry. In conclusion, the results of the present study indicate that the SWA is not able to overcome the drawbacks of accelerometry in assessing activities with limited vertical movement.
Literatur
Zurück zum Zitat Ainsworth BE, Haskell WL, Whitt MC et al (2000) Compendium of physical activities: an update of activity codes and MET intensities. Med Sci Sports Exerc 32:S498–S504PubMedCrossRef Ainsworth BE, Haskell WL, Whitt MC et al (2000) Compendium of physical activities: an update of activity codes and MET intensities. Med Sci Sports Exerc 32:S498–S504PubMedCrossRef
Zurück zum Zitat Arvidsson D, Slinde F, Larsson L, Hulthen L (2009) Energy cost in children assessed by multi-sensor activity monitors. Med Sci Sports Exerc 41:603–611PubMedCrossRef Arvidsson D, Slinde F, Larsson L, Hulthen L (2009) Energy cost in children assessed by multi-sensor activity monitors. Med Sci Sports Exerc 41:603–611PubMedCrossRef
Zurück zum Zitat Berntsen S, Hageberg R, Aandstad A et al (2010) Validity of physical activity monitors in adults participating in free-living activities. Br J Sports Med 44(9):657–664PubMedCrossRef Berntsen S, Hageberg R, Aandstad A et al (2010) Validity of physical activity monitors in adults participating in free-living activities. Br J Sports Med 44(9):657–664PubMedCrossRef
Zurück zum Zitat Bland MJ, Altman DG. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i:307–310 Bland MJ, Altman DG. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i:307–310
Zurück zum Zitat Calabro MA, Welk GJ, Eisenmann JC (2009) Validation of the SenseWear Pro Armband algorithms in children. Med Sci Sports Exerc 41:1714–1720PubMedCrossRef Calabro MA, Welk GJ, Eisenmann JC (2009) Validation of the SenseWear Pro Armband algorithms in children. Med Sci Sports Exerc 41:1714–1720PubMedCrossRef
Zurück zum Zitat Corder K, Brage S, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef Corder K, Brage S, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef
Zurück zum Zitat Corder K, Ekelund U, Steele RM, Wareham NJ, Brage S (2008) Assessment of physical activity in youth. J Appl Physiol 105(3):977–987PubMedCrossRef Corder K, Ekelund U, Steele RM, Wareham NJ, Brage S (2008) Assessment of physical activity in youth. J Appl Physiol 105(3):977–987PubMedCrossRef
Zurück zum Zitat Davies KK, Jakicic JM, Mealey AD, Mealey LM, McDermott MD (2007) Does clothing affect the accuracy of the SenseWear Pro Armband(TM) to estimate energy expenditure during walking? Med Sci Sport Exerc 39(5):S177 Davies KK, Jakicic JM, Mealey AD, Mealey LM, McDermott MD (2007) Does clothing affect the accuracy of the SenseWear Pro Armband(TM) to estimate energy expenditure during walking? Med Sci Sport Exerc 39(5):S177
Zurück zum Zitat Dorminy CA, Choi L, Akohouse SA, Chen KY, Buchowski MS (2008) Validity of a multisensory armband in estimating 24-h energy expenditure in children. Med Sci Sports Exerc 40:699–706PubMedCrossRef Dorminy CA, Choi L, Akohouse SA, Chen KY, Buchowski MS (2008) Validity of a multisensory armband in estimating 24-h energy expenditure in children. Med Sci Sports Exerc 40:699–706PubMedCrossRef
Zurück zum Zitat Ekelund U, Yngve A, Sjöström M, Westerterp K (2000) Field evaluation of the Computer Science and Application’s Inc. Activity monitor during running and skating training in adolescent athletes. Int J Sports Med 21(8):586–592PubMedCrossRef Ekelund U, Yngve A, Sjöström M, Westerterp K (2000) Field evaluation of the Computer Science and Application’s Inc. Activity monitor during running and skating training in adolescent athletes. Int J Sports Med 21(8):586–592PubMedCrossRef
Zurück zum Zitat Fruin ML, Rankin JW (2004) Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc 36:1063–1069PubMedCrossRef Fruin ML, Rankin JW (2004) Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc 36:1063–1069PubMedCrossRef
Zurück zum Zitat Hill EE, Zack E, Battaglini C, Viru M, Viru A, Hackney AC (2008) Exercise and circulating cortisol levels: the intensity threshold effect. J Endocrinol Invest 31(7):587–591PubMed Hill EE, Zack E, Battaglini C, Viru M, Viru A, Hackney AC (2008) Exercise and circulating cortisol levels: the intensity threshold effect. J Endocrinol Invest 31(7):587–591PubMed
Zurück zum Zitat King GA, Torres N, Potter C et al (2004) Comparison of activity monitors to estimate energy cost of treadmill exercise. Med Sci Sports Exerc 36(7):1244–1251PubMedCrossRef King GA, Torres N, Potter C et al (2004) Comparison of activity monitors to estimate energy cost of treadmill exercise. Med Sci Sports Exerc 36(7):1244–1251PubMedCrossRef
Zurück zum Zitat Koehler K, Braun H, de Marées M, Fusch G, Fusch C, Schaenzer W. (2010) Assessing energy expenditure in male endurance athletes: validity of the Sensewear Armband. Med Sci Sports Exerc. doi:10.1249/MSS.0b013e31820750f5 Koehler K, Braun H, de Marées M, Fusch G, Fusch C, Schaenzer W. (2010) Assessing energy expenditure in male endurance athletes: validity of the Sensewear Armband. Med Sci Sports Exerc. doi:10.​1249/​MSS.​0b013e31820750f5​
Zurück zum Zitat Maiolo C, Melchiorri G, Iacopino L, Masala S, De Lorenzo A (2003) Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer. Br J Sports Med 37(5):445–447PubMedCrossRef Maiolo C, Melchiorri G, Iacopino L, Masala S, De Lorenzo A (2003) Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer. Br J Sports Med 37(5):445–447PubMedCrossRef
Zurück zum Zitat Malavolti M, Pietrobelli A, Dugoni M et al (2007) A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr Metab Cardiovasc Dis 17:338–343PubMedCrossRef Malavolti M, Pietrobelli A, Dugoni M et al (2007) A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr Metab Cardiovasc Dis 17:338–343PubMedCrossRef
Zurück zum Zitat Sherker S, Cassell E (1998) In-line skating injury: a review of the literature. Monash University Accident Research Centre, Clayton Sherker S, Cassell E (1998) In-line skating injury: a review of the literature. Monash University Accident Research Centre, Clayton
Zurück zum Zitat Sirard JR, Pate RR (2001) Physical activity assessment in children and adolescents. Sports Med 31(6):439–454PubMedCrossRef Sirard JR, Pate RR (2001) Physical activity assessment in children and adolescents. Sports Med 31(6):439–454PubMedCrossRef
Zurück zum Zitat Weir JB (1949) New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol 109:1–9PubMed Weir JB (1949) New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol 109:1–9PubMed
Zurück zum Zitat Welk GJ, McClain JJ, Eisenmann JC, Wickel EE (2007) Field validation of the MTI Actigraph and BodyMedia armband monitor using the IDEEA monitor. Obesity 15:918–928PubMedCrossRef Welk GJ, McClain JJ, Eisenmann JC, Wickel EE (2007) Field validation of the MTI Actigraph and BodyMedia armband monitor using the IDEEA monitor. Obesity 15:918–928PubMedCrossRef
Zurück zum Zitat WHO (2009) Global health risks: mortality and burden of disease attributable to selected major risk factors. World Health Organization, Geneva WHO (2009) Global health risks: mortality and burden of disease attributable to selected major risk factors. World Health Organization, Geneva
Metadaten
Titel
Validation of the Sensewear Armband during recreational in-line skating
verfasst von
Maroje Soric
Pavle Mikulic
Marjeta Misigoj-Durakovic
Lana Ruzic
Goran Markovic
Publikationsdatum
01.03.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 3/2012
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-011-2045-6

Weitere Artikel der Ausgabe 3/2012

European Journal of Applied Physiology 3/2012 Zur Ausgabe