Skip to main content
Erschienen in: European Archives of Oto-Rhino-Laryngology 12/2017

22.09.2017 | Miscellaneous

Validity of wavelet transforms for analysis of video head impulse test (vHIT) results

verfasst von: Jorge Rey-Martinez

Erschienen in: European Archives of Oto-Rhino-Laryngology | Ausgabe 12/2017

Einloggen, um Zugang zu erhalten

Abstract

To explore the applicability of discrete wavelet transforms in the analysis of vHIT responses. Discrete wavelet transform was applied to vHIT responses and a new method for calculating aVOR gain was developed. A prospective study was performed with two groups of normal (N = 10) and altered (N = 19) gain values; HIMP and SHIMP vHIT protocols were performed on both groups. To evaluate the gain values obtained, Intraclass Correlation Index, Pearson’s correlation, linear regression, and t test were performed. Intraclass correlation indexes of 0.97 and 0.99 were determined for HIMP and SHIMP procedures performed on the proposed and standard gain calculation method. A significant difference of − 0.06 ± 0.07 (p < 0.001) was found between gain calculation methods for HIMP protocol. Significant differences were found (p < 0.001) between normal and altered groups for all gain calculation methods. Discrete wavelet transforms were successfully applied to measure head impulse test responses. Gain values obtained with this method appear to be valid and in concordance with gain values obtained with standard calculation method. However, a slight but significant difference was observed when this method was applied to tests obtained with HIMP.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
2.
Zurück zum Zitat Welgampola MS, Akdal G, Halmagyi GM (2017) Neuro-otology—some recent clinical advances. J Neurol 264:188–203CrossRefPubMed Welgampola MS, Akdal G, Halmagyi GM (2017) Neuro-otology—some recent clinical advances. J Neurol 264:188–203CrossRefPubMed
3.
Zurück zum Zitat MacDougall HG, Weber KP, McGarvie LA, Halmagyi GM, Curthoys IS (2009) The video head impulse test: diagnostic accuracy in peripheral vestibulopathy. Neurology 73:1134–1141CrossRefPubMedPubMedCentral MacDougall HG, Weber KP, McGarvie LA, Halmagyi GM, Curthoys IS (2009) The video head impulse test: diagnostic accuracy in peripheral vestibulopathy. Neurology 73:1134–1141CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Aw ST, Haslwanter T, Halmagyi GM, Curthoys IS, Yavor RA, Todd MJ (1996) Three-dimensional vector analysis of the human vestibuloocular reflex in response to high-acceleration head rotations. I. Responses in normal subjects. J Neurophysiol 76:4009–4020PubMed Aw ST, Haslwanter T, Halmagyi GM, Curthoys IS, Yavor RA, Todd MJ (1996) Three-dimensional vector analysis of the human vestibuloocular reflex in response to high-acceleration head rotations. I. Responses in normal subjects. J Neurophysiol 76:4009–4020PubMed
5.
Zurück zum Zitat Boleas-Aguirre M, Migliaccio AA, Carey JP (2007) Vestibulo-oculomotor reflex recording using the scleral search coil technique. Review of peripheral vestibular disorders. Acta Otorrinolaringol Esp 58:321–326CrossRefPubMedPubMedCentral Boleas-Aguirre M, Migliaccio AA, Carey JP (2007) Vestibulo-oculomotor reflex recording using the scleral search coil technique. Review of peripheral vestibular disorders. Acta Otorrinolaringol Esp 58:321–326CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Macdougall HG, McGarvie LA, Halmagyi GM, Curthoys IS, Weber KP (2013) The video head impulse test (vHIT) detects vertical semicircular canal dysfunction. PLoS One 8:e61488CrossRefPubMedPubMedCentral Macdougall HG, McGarvie LA, Halmagyi GM, Curthoys IS, Weber KP (2013) The video head impulse test (vHIT) detects vertical semicircular canal dysfunction. PLoS One 8:e61488CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Mantokoudis G, Saber Tehrani AS, Kattah JC, Eibenberger K, Guede CI, Zee DS, Newman-Toker DE (2015) Quantifying the vestibulo-ocular reflex with video-oculography: nature and frequency of artifacts. Audiol Neurootol 20:39–50CrossRefPubMed Mantokoudis G, Saber Tehrani AS, Kattah JC, Eibenberger K, Guede CI, Zee DS, Newman-Toker DE (2015) Quantifying the vestibulo-ocular reflex with video-oculography: nature and frequency of artifacts. Audiol Neurootol 20:39–50CrossRefPubMed
8.
Zurück zum Zitat Addison P (2002) The illustrated wavelet transform handbook: introductory theory and applications in science, engineering, medicine and finance. Institute of Physics Publishing, BristolCrossRef Addison P (2002) The illustrated wavelet transform handbook: introductory theory and applications in science, engineering, medicine and finance. Institute of Physics Publishing, BristolCrossRef
9.
Zurück zum Zitat Rey-Martinez J, Batuecas-Caletrio A, Matiño E, Perez Fernandez N (2015) HITCal: a software tool for analysis of video head impulse test responses. Acta Otolaryngol 135:886–894CrossRefPubMed Rey-Martinez J, Batuecas-Caletrio A, Matiño E, Perez Fernandez N (2015) HITCal: a software tool for analysis of video head impulse test responses. Acta Otolaryngol 135:886–894CrossRefPubMed
10.
Zurück zum Zitat Magosso E, Ursino M, Zaniboni A, Gardella E (2009) A wavelet-based energetic approach for the analysis of biomedical signals: application to the electroencephalogram and electro-oculogram. Appl Math Comput 207:42–62CrossRef Magosso E, Ursino M, Zaniboni A, Gardella E (2009) A wavelet-based energetic approach for the analysis of biomedical signals: application to the electroencephalogram and electro-oculogram. Appl Math Comput 207:42–62CrossRef
11.
Zurück zum Zitat Curthoys I, MacDougall H, McGarvie L, Weber K, Szmulewicz D, Manzari L, Burgess A (2016) Halmagyi G. In: Jacobson G, Shepard N (eds) Balance function assessment and management, 2nd edn. Plural Publishing, San Diego, pp 391–430 Curthoys I, MacDougall H, McGarvie L, Weber K, Szmulewicz D, Manzari L, Burgess A (2016) Halmagyi G. In: Jacobson G, Shepard N (eds) Balance function assessment and management, 2nd edn. Plural Publishing, San Diego, pp 391–430
12.
Zurück zum Zitat MacDougall HG, McGarvie LA, Halmagyi GM, Rogers SJ, Manzari L, Burgess AM, Curthoys IS, Weber KP (2016) A new saccadic indicator of peripheral vestibular function based on the video head impulse test. Neurology 87:410–418CrossRefPubMedPubMedCentral MacDougall HG, McGarvie LA, Halmagyi GM, Rogers SJ, Manzari L, Burgess AM, Curthoys IS, Weber KP (2016) A new saccadic indicator of peripheral vestibular function based on the video head impulse test. Neurology 87:410–418CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat McGarvie LA, MacDougall HG, Halmagyi GM, Burgess AM, Weber KP, Curthoys IS (2015) The video head impulse test (vHIT) of semicircular canal function—age-dependent normative values of VOR gain in healthy subjects. Front Neurol 8:154 McGarvie LA, MacDougall HG, Halmagyi GM, Burgess AM, Weber KP, Curthoys IS (2015) The video head impulse test (vHIT) of semicircular canal function—age-dependent normative values of VOR gain in healthy subjects. Front Neurol 8:154
14.
Zurück zum Zitat Matiño-Soler E, Esteller-More E, Martin-Sanchez JC, Martinez-Sanchez JM, Perez-Fernandez N (2015) Normative data on angular vestibulo-ocular responses in the yaw axis measured using the video head impulse test. Otol Neurotol 36:466–471CrossRefPubMed Matiño-Soler E, Esteller-More E, Martin-Sanchez JC, Martinez-Sanchez JM, Perez-Fernandez N (2015) Normative data on angular vestibulo-ocular responses in the yaw axis measured using the video head impulse test. Otol Neurotol 36:466–471CrossRefPubMed
15.
Zurück zum Zitat Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRefPubMed Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRefPubMed
16.
Zurück zum Zitat Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155–163CrossRefPubMedPubMedCentral Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155–163CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307–310CrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307–310CrossRef
18.
Zurück zum Zitat Moore C, Mertens S (2011) The nature of computation. Oxford University Press, OxfordCrossRef Moore C, Mertens S (2011) The nature of computation. Oxford University Press, OxfordCrossRef
Metadaten
Titel
Validity of wavelet transforms for analysis of video head impulse test (vHIT) results
verfasst von
Jorge Rey-Martinez
Publikationsdatum
22.09.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
European Archives of Oto-Rhino-Laryngology / Ausgabe 12/2017
Print ISSN: 0937-4477
Elektronische ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-017-4755-9

Weitere Artikel der Ausgabe 12/2017

European Archives of Oto-Rhino-Laryngology 12/2017 Zur Ausgabe

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.