Skip to main content
Erschienen in: European Radiology 2/2006

01.02.2006 | Chest

Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices

verfasst von: Ray Valencia, Timm Denecke, Lukas Lehmkuhl, Frank Fischbach, Roland Felix, Friedrich Knollmann

Erschienen in: European Radiology | Ausgabe 2/2006

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to investigate the diagnostic accuracy of non-overlapping 10-mm axial and coronal maximum intensity projections (MIP) in comparison with standard axial 1-mm and 5-mm slices in the detection of pulmonary nodules. Sixty patients with suspected nodules who underwent multislice spiral CT of the chest were evaluated. Axial 1-mm and 5-mm slices as well as non-overlapping 10-mm axial/coronal MIPs were interpreted independently by three blinded radiologists. After initial review, a retrospective consensus session was performed for agreement on final nodule counts using the axial 1-mm slices as gold standard. Small nodules of less than 5 mm in size were most accurately detected by the axial MIPs. Receiver operating characteristic (ROC) analysis of these small nodules showed that 5-mm slices were not capable of a statistically significant differentiation of nodules from other focal lesions in two observers (p=0.034 and p=0.012, respectively) whereas 1-mm slices and coronal/axial MIPs did allow a statistically significant differentiation in all observers (p<0.001). Nodules larger than 5 mm were equally well depicted with all modalities. Non-overlapping 10-mm axial MIPs improve the accuracy in the detection of small pulmonary nodules.
Literatur
1.
Zurück zum Zitat Austin JH, Muller NL, Friedman PJ, Hansell DM, Naidich DP, Remy-Jardin M, Webb WR, Zerhouni EA (1996) Glossary of terms for CT of the lungs: recommendations of the Nomenclature Committee of the Fleischner Society. Radiology 200:327–331PubMed Austin JH, Muller NL, Friedman PJ, Hansell DM, Naidich DP, Remy-Jardin M, Webb WR, Zerhouni EA (1996) Glossary of terms for CT of the lungs: recommendations of the Nomenclature Committee of the Fleischner Society. Radiology 200:327–331PubMed
2.
Zurück zum Zitat Remy-Jardin M, Remy J, Giraud F, Marquette CH (1993) Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology 187:513–520PubMed Remy-Jardin M, Remy J, Giraud F, Marquette CH (1993) Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology 187:513–520PubMed
3.
Zurück zum Zitat Tan BB, Flaherty KR, Kazerooni EA, Iannettoni MD (2003) The solitary pulmonary nodule. Chest 123:89S–96SCrossRefPubMed Tan BB, Flaherty KR, Kazerooni EA, Iannettoni MD (2003) The solitary pulmonary nodule. Chest 123:89S–96SCrossRefPubMed
4.
Zurück zum Zitat Fischbach F, Knollmann F, Griesshaber V, Freund T, Akkol E, Felix R (2003) Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13:2378–2383CrossRefPubMed Fischbach F, Knollmann F, Griesshaber V, Freund T, Akkol E, Felix R (2003) Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13:2378–2383CrossRefPubMed
5.
Zurück zum Zitat Gruden JF, Ouanounou S, Tigges S, Norris SD, Klausner TS (2002) Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT. Am J Roentgenol 179:149–157PubMed Gruden JF, Ouanounou S, Tigges S, Norris SD, Klausner TS (2002) Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT. Am J Roentgenol 179:149–157PubMed
6.
Zurück zum Zitat Diederich S, Lentschig MG, Overbeck TR, Wormanns D, Heindel W (2001) Detection of pulmonary nodules at spiral CT: comparison of maximum intensity projection sliding slabs and single-image reporting. Eur Radiol 11:1345–1350CrossRefPubMed Diederich S, Lentschig MG, Overbeck TR, Wormanns D, Heindel W (2001) Detection of pulmonary nodules at spiral CT: comparison of maximum intensity projection sliding slabs and single-image reporting. Eur Radiol 11:1345–1350CrossRefPubMed
7.
Zurück zum Zitat Coakley FV, Cohen MD, Johnson MS, Gonin R, Hanna MP (1998) Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT. Br J Radiol 71:135–140PubMed Coakley FV, Cohen MD, Johnson MS, Gonin R, Hanna MP (1998) Maximum intensity projection images in the detection of simulated pulmonary nodules by spiral CT. Br J Radiol 71:135–140PubMed
8.
Zurück zum Zitat Eibel R, Turk TR, Kulinna C, Herrmann K, Reiser MF (2001) Multidetector-row CT of the lungs: multiplanar reconstructions and maximum intensity projections for the detection of pulmonary nodules. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 173:815–821CrossRef Eibel R, Turk TR, Kulinna C, Herrmann K, Reiser MF (2001) Multidetector-row CT of the lungs: multiplanar reconstructions and maximum intensity projections for the detection of pulmonary nodules. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 173:815–821CrossRef
9.
Zurück zum Zitat Remy-Jardin M, Remy J, Artaud D, Deschildre F, Duhamel A (1996) Diffuse infiltrative lung disease: clinical value of sliding-thin-slab maximum intensity projection CT scans in the detection of mild micronodular patterns. Radiology 200:333–339PubMed Remy-Jardin M, Remy J, Artaud D, Deschildre F, Duhamel A (1996) Diffuse infiltrative lung disease: clinical value of sliding-thin-slab maximum intensity projection CT scans in the detection of mild micronodular patterns. Radiology 200:333–339PubMed
10.
Zurück zum Zitat Seltzer SE, Judy PF, Adams DF, Jacobson FL, Stark P, Kikinis R, Swensson RG, Hooton S, Head B, Feldman U (1995) Spiral CT of the chest: comparison of cine and film-based viewing. Radiology 197:73–78PubMed Seltzer SE, Judy PF, Adams DF, Jacobson FL, Stark P, Kikinis R, Swensson RG, Hooton S, Head B, Feldman U (1995) Spiral CT of the chest: comparison of cine and film-based viewing. Radiology 197:73–78PubMed
11.
Zurück zum Zitat Eibel R, Turk T, Kulinna C, Schopf UJ, Bruning R, Reiser MF (2001) Value of multiplanar reformations (MPR) in multi-slice spiral CT of the lung. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 173:57–64CrossRef Eibel R, Turk T, Kulinna C, Schopf UJ, Bruning R, Reiser MF (2001) Value of multiplanar reformations (MPR) in multi-slice spiral CT of the lung. Rofo Fortschr Geb Rontgenstrahlen Neuen Bildgeb Verfahr 173:57–64CrossRef
12.
Zurück zum Zitat Awai K, Murao K, Ozawa A, Komi M, Hayakawa H, Hori S, Nishimura Y (2004) Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists’ detection performance. Radiology 230:347–352PubMed Awai K, Murao K, Ozawa A, Komi M, Hayakawa H, Hori S, Nishimura Y (2004) Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists’ detection performance. Radiology 230:347–352PubMed
13.
Zurück zum Zitat Armato SG III, McLennan G, McNitt-Gray MF, Meyer CR, Yankelevitz D, Aberle DR, Henschke CI, Hoffman EA, Kazerooni EA, MacMahon H, Reeves AP, Croft BY, Clarke LP (2004) Lung image database consortium: developing a resource for the medical imaging research community. Radiology 232:739–748PubMed Armato SG III, McLennan G, McNitt-Gray MF, Meyer CR, Yankelevitz D, Aberle DR, Henschke CI, Hoffman EA, Kazerooni EA, MacMahon H, Reeves AP, Croft BY, Clarke LP (2004) Lung image database consortium: developing a resource for the medical imaging research community. Radiology 232:739–748PubMed
14.
Zurück zum Zitat Marten K, Grillhösl A, Seyfarth T, Obenauer S, Rummeny EJ, Engelke C (2005) Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings. Eur Radiol 15:203–212CrossRefPubMed Marten K, Grillhösl A, Seyfarth T, Obenauer S, Rummeny EJ, Engelke C (2005) Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings. Eur Radiol 15:203–212CrossRefPubMed
15.
Zurück zum Zitat Marten K, Seyfarth T, Auer F, Wiener E, Grillhösl A, Obenauer S, Rummeny EJ, Engelke C (2004) Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists. Eur Radiol 14:1930–1938CrossRefPubMed Marten K, Seyfarth T, Auer F, Wiener E, Grillhösl A, Obenauer S, Rummeny EJ, Engelke C (2004) Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists. Eur Radiol 14:1930–1938CrossRefPubMed
16.
Zurück zum Zitat Wormanns D, Ludwig K, Beyer F, Heindel W, Diederich S (2005) Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT. Eur Radiol 15:14–22CrossRefPubMed Wormanns D, Ludwig K, Beyer F, Heindel W, Diederich S (2005) Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT. Eur Radiol 15:14–22CrossRefPubMed
17.
Zurück zum Zitat Diederich S, Wormanns D, Semik M, Thomas M, Lenzen H, Roos N, Heindel W (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–781PubMed Diederich S, Wormanns D, Semik M, Thomas M, Lenzen H, Roos N, Heindel W (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773–781PubMed
18.
Zurück zum Zitat Swensen SJ, Jett JR, Sloan JA, Midthun DE, Hartman TE, Sykes AM, Aughenbaugh GL, Zink FE, Hillman SL, Noetzel GR, Marks RS, Clayton AC, Pairolero PC (2002) Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med 165:508–513PubMed Swensen SJ, Jett JR, Sloan JA, Midthun DE, Hartman TE, Sykes AM, Aughenbaugh GL, Zink FE, Hillman SL, Noetzel GR, Marks RS, Clayton AC, Pairolero PC (2002) Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med 165:508–513PubMed
19.
Zurück zum Zitat Henschke CI, McCauley DI, Yankelevitz DF, Naidich DP, McGuinness G, Miettinen OS, Libby DM, Pasmantier MW, Koizumi J, Altorki NK, Smith JP (1999) Early lung cancer action project: overall design and findings from baseline screening. Lancet 354:99–105CrossRefPubMed Henschke CI, McCauley DI, Yankelevitz DF, Naidich DP, McGuinness G, Miettinen OS, Libby DM, Pasmantier MW, Koizumi J, Altorki NK, Smith JP (1999) Early lung cancer action project: overall design and findings from baseline screening. Lancet 354:99–105CrossRefPubMed
20.
Zurück zum Zitat Wormanns D, Diederich S (2004) Characterization of small pulmonary nodules by CT. Eur Radiol 14:1380–1391PubMed Wormanns D, Diederich S (2004) Characterization of small pulmonary nodules by CT. Eur Radiol 14:1380–1391PubMed
21.
Zurück zum Zitat Benjamin MS, Drucker EA, McLoud TC, Shepard JA (2003) Small pulmonary nodules: detection at chest CT and outcome. Radiology 226:489–493PubMed Benjamin MS, Drucker EA, McLoud TC, Shepard JA (2003) Small pulmonary nodules: detection at chest CT and outcome. Radiology 226:489–493PubMed
22.
Zurück zum Zitat Greene RE (1992) Missed lung nodules: lost opportunities for cancer cure. Radiology 182:8–9PubMed Greene RE (1992) Missed lung nodules: lost opportunities for cancer cure. Radiology 182:8–9PubMed
23.
Zurück zum Zitat Diederich S, Semik M, Lentschig MG, Winter F, Scheld HH, Roos N, Bongartz G (1999) Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation. Am J Roentgenol 172:353–360 Diederich S, Semik M, Lentschig MG, Winter F, Scheld HH, Roos N, Bongartz G (1999) Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation. Am J Roentgenol 172:353–360
24.
Zurück zum Zitat Wormanns D, Diederich S, Lentschig MG, Winter F, Heindel W (2000) Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion size. Eur Radiol 10:710–713CrossRefPubMed Wormanns D, Diederich S, Lentschig MG, Winter F, Heindel W (2000) Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion size. Eur Radiol 10:710–713CrossRefPubMed
25.
Zurück zum Zitat Rubin GD (2000) Data explosion: the challenge of multidetector-row CT. Eur J Radiol 36:74–80CrossRefPubMed Rubin GD (2000) Data explosion: the challenge of multidetector-row CT. Eur J Radiol 36:74–80CrossRefPubMed
26.
Zurück zum Zitat Jhaveri KS, Saini S, Levine LA, Piazzo DJ, Doncaster RJ, Halpern EF, Jordan PF, Thrall JH (2001) Effect of multislice CT technology on scanner productivity. Am J Roentgenol 177:769–772 Jhaveri KS, Saini S, Levine LA, Piazzo DJ, Doncaster RJ, Halpern EF, Jordan PF, Thrall JH (2001) Effect of multislice CT technology on scanner productivity. Am J Roentgenol 177:769–772
Metadaten
Titel
Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices
verfasst von
Ray Valencia
Timm Denecke
Lukas Lehmkuhl
Frank Fischbach
Roland Felix
Friedrich Knollmann
Publikationsdatum
01.02.2006
Erschienen in
European Radiology / Ausgabe 2/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2871-1

Weitere Artikel der Ausgabe 2/2006

European Radiology 2/2006 Zur Ausgabe

Acknowledgement to Reviewers

Acknowledgement to reviewers 2005

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.