Abstract

Introduction

Generally range of motion (ROM) in total hip arthroplasty (THA) is intraoperatively assessed by eye. Can we assume that visual estimation of ROM is reliable?

Methods

60 patients underwent cementless THA in a subgroup analysis of a clinical prospective trial using a minimally invasive anterolateral approach in lateral decubitus position. Four experienced surgeons intraoperatively estimated ROM visually by assessment of the femur relative to the alignment of the patient’s pelvis. These estimations were compared with computer navigation measurements.

Results

We found a mean difference between navigation measurements and intraoperative estimations by eye of −5.6° (±10.9°; −17° to 30°) for flexion, respectively, −0.4° (±10.7°; −24° to 30°) for extension, 8.7° (±9.0°; −10° to 34°) for abduction, 5.9° (±18.3°; −58° to 68°) for external rotation and −5.8° (±12.1°; −38° to 22°) for internal rotation. Multivariate analysis showed no association between the visual accuracy of estimation of ROM and patient characteristics, such as BMI, sex, grade of osteoarthritis and treatment side except for a significant correlation of visual accuracy of estimation of extension and the level of professional experience. Otherwise, the level of professional experience had no impact on the accuracy of estimation of ROM by eye.

Conclusions

Even the experienced surgeon’s intraoperative estimation of ROM by eye is not reliable and differs up to 30° compared to objective measurements in minimally invasive THA. For accurate intraoperative assessment of ROM, the use of technical devices is recommended.

Trial registration

DRKS00000739.
Literatur
1.
Zurück zum Zitat Trousdale RT, Cabanela ME, Berry DJ (1995) Anterior iliopsoas impingement after total hip arthroplasty. J Arthroplasty 10:546–549CrossRefPubMed Trousdale RT, Cabanela ME, Berry DJ (1995) Anterior iliopsoas impingement after total hip arthroplasty. J Arthroplasty 10:546–549CrossRefPubMed
2.
Zurück zum Zitat Yoshimine F (2006) The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech 39:1315–1323CrossRefPubMed Yoshimine F (2006) The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements. J Biomech 39:1315–1323CrossRefPubMed
3.
Zurück zum Zitat Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F (2002) Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17:359–364CrossRefPubMed Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F (2002) Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17:359–364CrossRefPubMed
4.
Zurück zum Zitat Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A (2005) Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J 25:1–9PubMedPubMedCentral Dorr LD, Hishiki Y, Wan Z, Newton D, Yun A (2005) Development of imageless computer navigation for acetabular component position in total hip replacement. Iowa Orthop J 25:1–9PubMedPubMedCentral
5.
Zurück zum Zitat Dorr LD, Malik A, Wan Z, Long WT, Harris M (2007) Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res 465:92–99PubMed Dorr LD, Malik A, Wan Z, Long WT, Harris M (2007) Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position. Clin Orthop Relat Res 465:92–99PubMed
6.
Zurück zum Zitat Komeno M, Hasegawa M, Sudo A, Uchida A (2006) Computed tomographic evaluation of component position on dislocation after total hip arthroplasty. Orthopedics 29:1104–1108PubMed Komeno M, Hasegawa M, Sudo A, Uchida A (2006) Computed tomographic evaluation of component position on dislocation after total hip arthroplasty. Orthopedics 29:1104–1108PubMed
7.
Zurück zum Zitat Grifka J, Keshmiri A, Maderbacher B, Craiovan B (2014) Clinical examination of the adult hip joint. Orthopade 43:1115–1133CrossRefPubMed Grifka J, Keshmiri A, Maderbacher B, Craiovan B (2014) Clinical examination of the adult hip joint. Orthopade 43:1115–1133CrossRefPubMed
8.
Zurück zum Zitat D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW (2000) The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 82:315PubMed D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW (2000) The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 82:315PubMed
9.
Zurück zum Zitat Jerosch J, Filler TJ, Peuker ET (2002) The cartilage of the tibiofibular joint: a source for autologous osteochondral grafts without damaging weight-bearing joint surfaces. Arch Orthop Trauma Surg 122:217CrossRefPubMed Jerosch J, Filler TJ, Peuker ET (2002) The cartilage of the tibiofibular joint: a source for autologous osteochondral grafts without damaging weight-bearing joint surfaces. Arch Orthop Trauma Surg 122:217CrossRefPubMed
10.
Zurück zum Zitat Miki H, Yamanashi W, Nishii T, Sato Y, Yoshikawa H, Sugano N (2007) Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty 7:946–952CrossRef Miki H, Yamanashi W, Nishii T, Sato Y, Yoshikawa H, Sugano N (2007) Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty 7:946–952CrossRef
11.
Zurück zum Zitat Seki M, Yuasa N, Ohkuni K (1998) Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation. J Orthop Res 16:513CrossRefPubMed Seki M, Yuasa N, Ohkuni K (1998) Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation. J Orthop Res 16:513CrossRefPubMed
12.
Zurück zum Zitat Widmer KH, Zurfluh B (2004) Compliant positioning of total hip components for optimal range of motion. J Orthop Res 22:815CrossRefPubMed Widmer KH, Zurfluh B (2004) Compliant positioning of total hip components for optimal range of motion. J Orthop Res 22:815CrossRefPubMed
13.
Zurück zum Zitat Amstutz HC, Lodwig RM, Schurman DJ, Hodgson AG (1975) Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clin Orthop Relat Res 111:124–130CrossRefPubMed Amstutz HC, Lodwig RM, Schurman DJ, Hodgson AG (1975) Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clin Orthop Relat Res 111:124–130CrossRefPubMed
14.
Zurück zum Zitat Davis KE, Ritter MA, Berend ME, Meding JB (2007) The importance of range of motion after total hip arthroplasty. Clin Orthop Relat Res 465:180–184PubMed Davis KE, Ritter MA, Berend ME, Meding JB (2007) The importance of range of motion after total hip arthroplasty. Clin Orthop Relat Res 465:180–184PubMed
15.
Zurück zum Zitat Renkawitz T, Weber M, Springorum R, Sendtner E, Woerner M, Ulm K, Weber T, Grifka J (2015) Impingement-free range of movement, acetabular component cover and early clinical results comparing ‘femur-first’ navigation and ‘conventional’ minimally invasive total hip arthroplasty: a randomised controlled trial. Bone Joint J 97(7):890–898CrossRefPubMed Renkawitz T, Weber M, Springorum R, Sendtner E, Woerner M, Ulm K, Weber T, Grifka J (2015) Impingement-free range of movement, acetabular component cover and early clinical results comparing ‘femur-first’ navigation and ‘conventional’ minimally invasive total hip arthroplasty: a randomised controlled trial. Bone Joint J 97(7):890–898CrossRefPubMed
16.
Zurück zum Zitat Wu G, Siegler S, Allard P, Kirtley C, Leardini A, Rosenbaum D, Whittle M, D’Lima DD, Cristofolini L, Witte H, Schmid O, Stokes I (2002) ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spine. International Society of Biomechanics. J Biomech 35:543–548CrossRefPubMed Wu G, Siegler S, Allard P, Kirtley C, Leardini A, Rosenbaum D, Whittle M, D’Lima DD, Cristofolini L, Witte H, Schmid O, Stokes I (2002) ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spine. International Society of Biomechanics. J Biomech 35:543–548CrossRefPubMed
17.
Zurück zum Zitat Renkawitz T, Haimerl M, Dohmen L, Woerner M, Springorum HR, Sendtner E, Heers G, Weber M, Grifka J (2012) Development and evaluation of an image-free computer-assisted impingement detection technique for total hip arthroplasty. Proc Inst Mech Eng H 226(12):911–918CrossRefPubMed Renkawitz T, Haimerl M, Dohmen L, Woerner M, Springorum HR, Sendtner E, Heers G, Weber M, Grifka J (2012) Development and evaluation of an image-free computer-assisted impingement detection technique for total hip arthroplasty. Proc Inst Mech Eng H 226(12):911–918CrossRefPubMed
18.
Zurück zum Zitat Michel M, Witschger P (2007) MicroHip: a minimally invasive procedure for total hip replacement surgery using a modified Smith-Peterson approach. Ortop Traumatol Rehabil 9:46–51PubMed Michel M, Witschger P (2007) MicroHip: a minimally invasive procedure for total hip replacement surgery using a modified Smith-Peterson approach. Ortop Traumatol Rehabil 9:46–51PubMed
19.
Zurück zum Zitat Renkawitz T, Haimerl M, Dohmen L, Gneiting S, Wegner M, Ehret N, Buchele C, Schubert M, Lechler P, Woerner M, Sendtner E, Schuster T, Ulm K, Springorum R, Grifka J (2011) Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial. BMC Musculoskelet Disord 19(12):192CrossRef Renkawitz T, Haimerl M, Dohmen L, Gneiting S, Wegner M, Ehret N, Buchele C, Schubert M, Lechler P, Woerner M, Sendtner E, Schuster T, Ulm K, Springorum R, Grifka J (2011) Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial. BMC Musculoskelet Disord 19(12):192CrossRef
20.
21.
Zurück zum Zitat Turley GA, Ahmed SM, Williams MA, Griffin DR (2011) Establishing a range of motion boundary for total hip arthroplasty. Proc Inst Mech Eng H 225:769–782CrossRefPubMed Turley GA, Ahmed SM, Williams MA, Griffin DR (2011) Establishing a range of motion boundary for total hip arthroplasty. Proc Inst Mech Eng H 225:769–782CrossRefPubMed
22.
Zurück zum Zitat Hube R, Dienst M, von Roth P (2014) Complications after minimally invasive total hip arthroplasty. Orthopade 43:47–53CrossRefPubMed Hube R, Dienst M, von Roth P (2014) Complications after minimally invasive total hip arthroplasty. Orthopade 43:47–53CrossRefPubMed
23.
Zurück zum Zitat Zenk K, Finze S, Kluess D, Bader R, Malzahn J, Mittelmeier W (2014) Influence of Surgeon’s experience in total hip arthroplasty. Orthopade 43:522–528CrossRefPubMed Zenk K, Finze S, Kluess D, Bader R, Malzahn J, Mittelmeier W (2014) Influence of Surgeon’s experience in total hip arthroplasty. Orthopade 43:522–528CrossRefPubMed
24.
Zurück zum Zitat Kapandji IA (1985) Physiologie articulaire. Maloine, Paris Kapandji IA (1985) Physiologie articulaire. Maloine, Paris
25.
Zurück zum Zitat Nadzadi ME, Pedersen DR, Yack HJ, Callaghan JJ, Brown TD (2003) Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech 36:577–591CrossRefPubMed Nadzadi ME, Pedersen DR, Yack HJ, Callaghan JJ, Brown TD (2003) Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech 36:577–591CrossRefPubMed
Metadaten
Titel
Visual intraoperative estimation of range of motion is misleading in minimally invasive total hip arthroplasty
verfasst von
Michael Woerner
Markus Weber
Ernst Sendtner
Robert Springorum
Michael Worlicek
Benjamin Craiovan
Joachim Grifka
Tobias Renkawitz
Publikationsdatum
28.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 7/2016
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-016-2478-9

Weitere Artikel der Ausgabe 7/2016

Archives of Orthopaedic and Trauma Surgery 7/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.