Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 5/2016

29.12.2015 | Cornea

Visual outcomes after femtosecond-assisted intracorneal MyoRing implantation: 18 months of follow-up

verfasst von: Masoomeh Mohebbi, Hassan Hashemi, Soheila Asgari, Sara Bigdeli, Kambiz Ameli Zamani

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To determine the long-term results of femtosecond-assisted MyoRing implantation for the treatment of keratoconus.

Methods

In this prospective, non-randomized, interventional clinical study, 47 eyes of 46 patients with keratoconus grade 1 to 3 entered the study. For all patients, a MyoRing (Dioptex, GmbH, Austria) was implanted using a femtosecond laser (Femto LDV, Ziemer, Germany).

Results

At 18 months, mean uncorrected and best corrected visual acuity was 0.41 ± 0.19 logMAR, (P = 0.004) and 0.62 ± 0.22 logMAR (P < 0.001), and mean manifest refraction spherical equivalent was −0.38 ± 2.62D (P < 0.001). The central 3-mm maximum and mean keratometry decreased by 5.20 ± 3.06D and 4.77 ± 2.47D, respectively (both P < 0.001), and the 8-mm maximum keratometry decreased by 1.16 ± 5.50D (P = 0.185). Central and minimal corneal thickness showed an insignificant increase. Both corneal hysteresis and corneal resistance factor showed an insignificant decrease of about 0.13 mmHg. Endothelial cell count decreased by 215.43 ± 300.55 cell/mm2 (P < 0.001). Twenty-six subjects (55.3 %) had halo vision at night and 24 subjects (51.1 %) had glare at night.

Conclusions

Femtosecond-assisted intracorneal MyoRing implantation can be an appropriate treatment option in keratoconus patients with central corneal protrusion, but the incidence of optical disturbances can be relatively high.
Literatur
1.
Zurück zum Zitat Daxer A (2010) Adjustable intracorneal ring in a lamellar pocket for keratoconus. J Refract Surg 26:217–221CrossRefPubMed Daxer A (2010) Adjustable intracorneal ring in a lamellar pocket for keratoconus. J Refract Surg 26:217–221CrossRefPubMed
2.
Zurück zum Zitat Mahmood H, Venkateswaran RS, Daxer A (2011) Implantation of a complete corneal ring in an intrastromal pocket for keratoconus. J Refract Surg 27:63–68CrossRefPubMed Mahmood H, Venkateswaran RS, Daxer A (2011) Implantation of a complete corneal ring in an intrastromal pocket for keratoconus. J Refract Surg 27:63–68CrossRefPubMed
3.
Zurück zum Zitat Daxer A, Mahmoud H, Venkateswaran RS (2010) Intracorneal continuous ring implantation for keratoconus: One-year follow-up. J Cataract Refract Surg 36:1296–1302CrossRefPubMed Daxer A, Mahmoud H, Venkateswaran RS (2010) Intracorneal continuous ring implantation for keratoconus: One-year follow-up. J Cataract Refract Surg 36:1296–1302CrossRefPubMed
4.
Zurück zum Zitat Alio JL, Pinero DP, Daxer A (2011) Clinical outcomes after complete ring implantation in corneal ectasia using the femtosecond technology: a pilot study. Ophthalmology 118:1282–1290PubMed Alio JL, Pinero DP, Daxer A (2011) Clinical outcomes after complete ring implantation in corneal ectasia using the femtosecond technology: a pilot study. Ophthalmology 118:1282–1290PubMed
5.
Zurück zum Zitat Jabbarvand M, Salamatrad A, Hashemian H, Khodaparast M (2013) Continuous corneal intrastromal ring implantation for treatment of keratoconus in an Iranian population. Am J Ophthalmol 155:837–842CrossRefPubMed Jabbarvand M, Salamatrad A, Hashemian H, Khodaparast M (2013) Continuous corneal intrastromal ring implantation for treatment of keratoconus in an Iranian population. Am J Ophthalmol 155:837–842CrossRefPubMed
6.
Zurück zum Zitat Daxer B, Mahmood H, Daxer A (2012) MyoRing treatment for keratoconus: DIOPTEX PocketMaker vs Zeimer LDV for corneal pocket creation. Int J Kerat Ect Cor Dis 1:151–152 Daxer B, Mahmood H, Daxer A (2012) MyoRing treatment for keratoconus: DIOPTEX PocketMaker vs Zeimer LDV for corneal pocket creation. Int J Kerat Ect Cor Dis 1:151–152
7.
Zurück zum Zitat Daxer A (2012) MyoRing for central and noncentral keratoconus. Int J Kerat Ect Cor Dis 1:117–119 Daxer A (2012) MyoRing for central and noncentral keratoconus. Int J Kerat Ect Cor Dis 1:117–119
8.
Zurück zum Zitat Kubaloglu A, Cinar Y, Sari ES, Koytak A, Ozdemir B, Ozerturk Y (2010) Comparison of 2 intrastromal corneal ring segment models in the management of keratoconus. J Cataract Refract Surg 36:978–985CrossRefPubMed Kubaloglu A, Cinar Y, Sari ES, Koytak A, Ozdemir B, Ozerturk Y (2010) Comparison of 2 intrastromal corneal ring segment models in the management of keratoconus. J Cataract Refract Surg 36:978–985CrossRefPubMed
9.
Zurück zum Zitat Pinero DP, Alio JL, El Kady B, Coskunseven E, Morbelli H, Uceda-Montanes A, Maldonado MJ, Cuevas D, Pascual I (2009) Refractive and aberrometric outcomes of intracorneal ring segments for keratoconus: mechanical versus femtosecond-assisted procedures. Ophthalmology 116:1675–1687CrossRefPubMed Pinero DP, Alio JL, El Kady B, Coskunseven E, Morbelli H, Uceda-Montanes A, Maldonado MJ, Cuevas D, Pascual I (2009) Refractive and aberrometric outcomes of intracorneal ring segments for keratoconus: mechanical versus femtosecond-assisted procedures. Ophthalmology 116:1675–1687CrossRefPubMed
10.
Zurück zum Zitat Carrasquillo KG, Rand J, Talamo JH (2007) Intacs for keratoconus and post-LASIK ectasia: mechanical versus femtosecond laser-assisted channel creation. Cornea 26:956–962CrossRefPubMed Carrasquillo KG, Rand J, Talamo JH (2007) Intacs for keratoconus and post-LASIK ectasia: mechanical versus femtosecond laser-assisted channel creation. Cornea 26:956–962CrossRefPubMed
11.
Zurück zum Zitat Kubaloglu A, Sari ES, Cinar Y, Cingu K, Koytak A, Coşkun E, Ozertürk Y (2010) Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial. J Cataract Refract Surg 36:1556–1561CrossRefPubMed Kubaloglu A, Sari ES, Cinar Y, Cingu K, Koytak A, Coşkun E, Ozertürk Y (2010) Comparison of mechanical and femtosecond laser tunnel creation for intrastromal corneal ring segment implantation in keratoconus: prospective randomized clinical trial. J Cataract Refract Surg 36:1556–1561CrossRefPubMed
12.
Zurück zum Zitat Ferrara P, Torquetti L (2010) Corneal endothelial profile after Ferrara ring implantation. J Emmetropia 1:29–32 Ferrara P, Torquetti L (2010) Corneal endothelial profile after Ferrara ring implantation. J Emmetropia 1:29–32
13.
Zurück zum Zitat Takács AI, Kovács I, Miháltz K, Filkorn T, Knorz MC, Nagy ZZ (2012) Central corneal volume and endothelial cell count following femtosecond laser-assisted refractive cataract surgery compared to conventional phacoemulsification. J Refract Surg 28:387–391CrossRefPubMed Takács AI, Kovács I, Miháltz K, Filkorn T, Knorz MC, Nagy ZZ (2012) Central corneal volume and endothelial cell count following femtosecond laser-assisted refractive cataract surgery compared to conventional phacoemulsification. J Refract Surg 28:387–391CrossRefPubMed
14.
Zurück zum Zitat Azar RG, Holdbrook MJ, Lemp M, Edelhauser HF, KeraVision Study Group (2001) Two-year corneal endothelial cell assessment following INTACS implantation. J Refract Surg 17:542–548PubMed Azar RG, Holdbrook MJ, Lemp M, Edelhauser HF, KeraVision Study Group (2001) Two-year corneal endothelial cell assessment following INTACS implantation. J Refract Surg 17:542–548PubMed
15.
Zurück zum Zitat Liu T, Zhang J, Sun D, Sui W, Zhang Y, Li D, Chen Z, Gao H (2014) Comparative study of corneal endothelial cell damage after femtosecond laser assisted deep stromal dissection. BioMed Res Int 2014:731565PubMedPubMedCentral Liu T, Zhang J, Sun D, Sui W, Zhang Y, Li D, Chen Z, Gao H (2014) Comparative study of corneal endothelial cell damage after femtosecond laser assisted deep stromal dissection. BioMed Res Int 2014:731565PubMedPubMedCentral
16.
Zurück zum Zitat Sturbaum CW, Peiffer RL (1993) Pathology of corneal endothelium in keratoconus. Ophthalmologica 206:192–208CrossRefPubMed Sturbaum CW, Peiffer RL (1993) Pathology of corneal endothelium in keratoconus. Ophthalmologica 206:192–208CrossRefPubMed
17.
Zurück zum Zitat Li Y, Tan O, Brass R, Weiss JL, Huang D (2012) Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology 119(12):2425–2433CrossRefPubMedPubMedCentral Li Y, Tan O, Brass R, Weiss JL, Huang D (2012) Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology 119(12):2425–2433CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Holmes-Higgin DK, Burris TE, Lapidus JA, Greenlick MR (2002) Risk factors for self-reported visual symptoms with intacs inserts for myopia. Ophthalmology 109:46–56CrossRefPubMed Holmes-Higgin DK, Burris TE, Lapidus JA, Greenlick MR (2002) Risk factors for self-reported visual symptoms with intacs inserts for myopia. Ophthalmology 109:46–56CrossRefPubMed
19.
Zurück zum Zitat Ruckhofer J, Stoiber J, Alzner E, Grabner G, Multicenter European Corneal Correction Assessment Study Group (2001) One year results of European multicenter study of intrastromal corneal ring segments. Part 2: complications, visual symptoms, and patient satisfaction. J Cataract Refract Surg 27:287–296CrossRefPubMed Ruckhofer J, Stoiber J, Alzner E, Grabner G, Multicenter European Corneal Correction Assessment Study Group (2001) One year results of European multicenter study of intrastromal corneal ring segments. Part 2: complications, visual symptoms, and patient satisfaction. J Cataract Refract Surg 27:287–296CrossRefPubMed
21.
Zurück zum Zitat Cohen AW, Goins KM, Sutphin JE, Wandling GR, Wagoner MD (2010) Penetrating keratoplasty versus deep anterior lamellar keratoplasty for the treatment of keratoconus. Int Ophthalmol 30:675–681CrossRefPubMed Cohen AW, Goins KM, Sutphin JE, Wandling GR, Wagoner MD (2010) Penetrating keratoplasty versus deep anterior lamellar keratoplasty for the treatment of keratoconus. Int Ophthalmol 30:675–681CrossRefPubMed
22.
Zurück zum Zitat Applegate RA, Gansel KA (1990) The importance of pupil size in optical quality measurements following radial keratotomy. Refract Corneal Surg 6:47–54PubMed Applegate RA, Gansel KA (1990) The importance of pupil size in optical quality measurements following radial keratotomy. Refract Corneal Surg 6:47–54PubMed
Metadaten
Titel
Visual outcomes after femtosecond-assisted intracorneal MyoRing implantation: 18 months of follow-up
verfasst von
Masoomeh Mohebbi
Hassan Hashemi
Soheila Asgari
Sara Bigdeli
Kambiz Ameli Zamani
Publikationsdatum
29.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 5/2016
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-015-3231-8

Weitere Artikel der Ausgabe 5/2016

Graefe's Archive for Clinical and Experimental Ophthalmology 5/2016 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.