Skip to main content
Erschienen in: Journal of Nuclear Cardiology 4/2017

01.08.2017 | Editorial

What are the necessary corrections for dynamic cardiac SPECT?

verfasst von: Brian F. Hutton, PhD, Simona Ben-Haim, MD, DSc

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Excerpt

Myocardial blood flow (MBF) and myocardial flow reserve (MFR) are important physiologic parameters for the detection of hemodynamically significant coronary artery disease (CAD) and have been shown to improve diagnostic accuracy and risk stratification of myocardial perfusion imaging (MPI), beyond that provided by relative perfusion abnormalities alone. Quantitative assessment of MBF can be obtained from cardiac PET, however, it is infrequently used in clinical practice due to the limited availability of PET scanners, suitable radiotracers, and dedicated software as compared to the widely used SPECT. MPI SPECT with conventional Anger technology has been traditionally limited to visual analysis or semiquantitative perfusion analysis. SPECT quantification of MBF requires fast acquisition of dynamic data in 5-10 seconds, as well as corrections, mainly for attenuation and scatter, which enable absolute measurement. …
Literatur
1.
Zurück zum Zitat Wang L, Wu D, Yang Y, Chen I-J, Lin C-Y, Hsu B, et al. Avoiding full corrections in Dynamic SPECT images impacts the performance of SPECT myocardial perfusion blood flow quantitation. J Nucl Cardiol 2016;. doi:10.1007/s12350-016-0513-4.CrossRefPubMed Wang L, Wu D, Yang Y, Chen I-J, Lin C-Y, Hsu B, et al. Avoiding full corrections in Dynamic SPECT images impacts the performance of SPECT myocardial perfusion blood flow quantitation. J Nucl Cardiol 2016;. doi:10.​1007/​s12350-016-0513-4.CrossRefPubMed
2.
Zurück zum Zitat Hendel RC, Corbett JR, Cullom SJ, Depuey EG, Garcia EV, Bateman TM. The value and practice of attenuation correction for myocardial perfusion spect imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine. J Nucl Med 2002;43:273-80. Hendel RC, Corbett JR, Cullom SJ, Depuey EG, Garcia EV, Bateman TM. The value and practice of attenuation correction for myocardial perfusion spect imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine. J Nucl Med 2002;43:273-80.
3.
Zurück zum Zitat Erlandsson K, Buvat I, Pretorius PH, Thomas BA, Hutton BF. A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology. Phys Med Biol 2012;57:R119-59.CrossRef Erlandsson K, Buvat I, Pretorius PH, Thomas BA, Hutton BF. A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology. Phys Med Biol 2012;57:R119-59.CrossRef
4.
Zurück zum Zitat Schafers KP, Stegger L. Combined imaging of molecular function and morphology: Image fusion and motion correction. Basic Res Cardiol 2008;103:191-9.CrossRef Schafers KP, Stegger L. Combined imaging of molecular function and morphology: Image fusion and motion correction. Basic Res Cardiol 2008;103:191-9.CrossRef
5.
Zurück zum Zitat Gullberg GT, Reutter BW, Sitek A, Maltz JS, Budinger TF. Dynamic single photon emission computed tomography—Basic principles and cardiac applications. Phys Med Biol 2010;55:R111-91.CrossRef Gullberg GT, Reutter BW, Sitek A, Maltz JS, Budinger TF. Dynamic single photon emission computed tomography—Basic principles and cardiac applications. Phys Med Biol 2010;55:R111-91.CrossRef
6.
Zurück zum Zitat Wells RG, Timmins R, Klein R, Lockwood J, Marvin B, deKemp RA, et al. Dynamic SPECT measurement of absolute myocardial blood flow in a porcine model. J Nucl Med 2014;55:1-7.CrossRef Wells RG, Timmins R, Klein R, Lockwood J, Marvin B, deKemp RA, et al. Dynamic SPECT measurement of absolute myocardial blood flow in a porcine model. J Nucl Med 2014;55:1-7.CrossRef
7.
Zurück zum Zitat Ben-Haim S, Murthy VL, Breault C, Allie R, Sitek A, Roth N, et al. Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans: A feasibility study. J Nucl Med 2013;54:873-9.CrossRef Ben-Haim S, Murthy VL, Breault C, Allie R, Sitek A, Roth N, et al. Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans: A feasibility study. J Nucl Med 2013;54:873-9.CrossRef
8.
Zurück zum Zitat Bocher M, Blevis IM, Tsukerman L. Shrem Y, Kovaski G, Volokh L. A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. Eur J Nucl Med Mol Imaging 2010;37:1887-902.CrossRef Bocher M, Blevis IM, Tsukerman L. Shrem Y, Kovaski G, Volokh L. A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. Eur J Nucl Med Mol Imaging 2010;37:1887-902.CrossRef
10.
Zurück zum Zitat Ritt P, Vija H, Hornegger J, Kuwert T. Absolute quantification in SPECT. Eur J Nucl Med Mol Imaging 2011;38:S69-77.CrossRef Ritt P, Vija H, Hornegger J, Kuwert T. Absolute quantification in SPECT. Eur J Nucl Med Mol Imaging 2011;38:S69-77.CrossRef
11.
Zurück zum Zitat Willowson K, Bailey DL, Baldock C. Quantitative SPECT reconstruction using CT-derived corrections. Phys Med Biol 2008;53:3099-112.CrossRef Willowson K, Bailey DL, Baldock C. Quantitative SPECT reconstruction using CT-derived corrections. Phys Med Biol 2008;53:3099-112.CrossRef
12.
Zurück zum Zitat Shcherbinin S, Celler A, Belhocine T, Vanderwerf R, Driedger A. Accuracy of quantitative reconstructions in SPECT/CT imaging. Phys Med Biol 2008;53:4595-604.CrossRef Shcherbinin S, Celler A, Belhocine T, Vanderwerf R, Driedger A. Accuracy of quantitative reconstructions in SPECT/CT imaging. Phys Med Biol 2008;53:4595-604.CrossRef
Metadaten
Titel
What are the necessary corrections for dynamic cardiac SPECT?
verfasst von
Brian F. Hutton, PhD
Simona Ben-Haim, MD, DSc
Publikationsdatum
01.08.2017
Verlag
Springer International Publishing
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 4/2017
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-016-0580-6

Weitere Artikel der Ausgabe 4/2017

Journal of Nuclear Cardiology 4/2017 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Vorhofflimmern bei Jüngeren gefährlicher als gedacht

06.05.2024 Vorhofflimmern Nachrichten

Immer mehr jüngere Menschen leiden unter Vorhofflimmern. Betroffene unter 65 Jahren haben viele Risikofaktoren und ein signifikant erhöhtes Sterberisiko verglichen mit Gleichaltrigen ohne die Erkrankung.

Chronisches Koronarsyndrom: Gefahr von Hospitalisierung wegen Herzinsuffizienz

06.05.2024 Herzinsuffizienz Nachrichten

Obwohl ein rezidivierender Herzinfarkt bei chronischem Koronarsyndrom wahrscheinlich die Hauptsorge sowohl der Patienten als auch der Ärzte ist, sind andere Ereignisse womöglich gefährlicher. Laut einer französischen Studie stellt eine Hospitalisation wegen Herzinsuffizienz eine größere Gefahr dar.

Das Risiko für Vorhofflimmern in der Bevölkerung steigt

02.05.2024 Vorhofflimmern Nachrichten

Das Risiko, im Lauf des Lebens an Vorhofflimmern zu erkranken, ist in den vergangenen 20 Jahren gestiegen: Laut dänischen Zahlen wird es drei von zehn Personen treffen. Das hat Folgen weit über die Schlaganfallgefährdung hinaus.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.