Open Access 01.12.2023 | Case Report

A case of stent-assisted balloon-induced intimal disruption and relamination of distal remaining aortic dissection after the ascending aorta and aortic arch replacement for acute aortic dissection

verfasst von: Seito Shimizu, Yujiro Kawai, Yuki Horinouchi, Ayaka Yu, Masanori Hayashi, Kanako Kobayashi, Takahito Itoh, Naoki Fujimura, Hirohisa Harada, Satoshi Ohtsubo

Erschienen in: General Thoracic and Cardiovascular Surgery Cases | Ausgabe 1/2023

Abstract

Background

The early survival rate of patients with acute type A aortic dissection (TAAD) has improved remarkably over the past two decades. However, a false lumen may remain after proximal aortic repair and is a potential risk factor for aortic diameter enlargement, aortic rupture, and death in the chronic phase. In the stent-assisted balloon-induced intimal disruption and relamination of aortic dissection (STABILISE) technique, a stent graft is implanted at the proximal part of the aortic dissection, followed by bare-metal aortic stent placement over the distal aortic dissection. Next, an aortic balloon catheter is dilated inside the stent graft and the bare stent to disrupt the intima and collapse the false lumen, immediately restoring uniluminal thoracoabdominal aortic flow. This report describes our experience with the STABILISE technique for a residual aortic dissection after an ascending aorta, and partial aortic arch replacement for acute TAAD resulted in complications.

Case presentation

A 60-year-old man presented to our hospital with chest pain, paresthesia, and left lower-limb paralysis. He was diagnosed with acute type A aortic dissection (TAAD) and malperfusion of the left lower limb by computed tomography (CT), and an emergent ascending aorta and partial aortic arch replacement were performed. Immediately after surgery, the left femoral arterial pulse improved, and left lower limb revascularization was deferred. The postoperative course was good; however, back pain and intermittent claudication recurred on the 9th day after surgery. A CT examination revealed persistent antegrade false lumen flow in the descending thoracic aorta through the left subclavian artery dissection and retrograde false lumen flow from the thoracoabdominal segment, resulting in aortic diameter enlargement and narrowing of the true lumen. The symptoms did not improve, and the STABILISE technique was performed on the 12th day after the initial aortic surgery. The patient’s subsequent course was good; the back pain and intermittent claudication resolved. The patient was discharged on the 8th day after the STABILISE technique.

Conclusions

The STABILISE technique can obliterate the false lumen and resolve symptoms associated with a residual false lumen after proximal aortic repair for acute TAAD.
Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
TAAD
Type A aortic dissection
STABILISE
Stent-assisted balloon-induced intimal disruption and relamination of aortic dissection
CT
Computed tomography
EIA
External iliac arteries
BCA
Brachiocephalic artery
CCA
Common carotid artery
SCA
Subclavian artery
CFA
Common femoral artery
ABI
Ankle-brachial pressure index
CIA
Common iliac artery
TEVAR
Thoracic endovascular aortic repair
SINE
Stent-graft-induced new entry
TBAD
Type B aortic dissection

Background

The early survival rate for acute type A aortic dissection (TAAD) has improved remarkably over the past two decades. However, a false lumen may remain in the descending and abdominal aortas after proximal aortic repair. A residual false lumen can cause problems, such as rapid dilatation of the aorta, narrowing of the true lumen, and malperfusion in the acute phase. For instance, Park et al. reported an abdominal aortic false lumen patency of up to 89% after acute DeBakey type 1 aortic dissection repair [1]. Furthermore, persistent patency of a false lumen of the thoracoabdominal aorta has been reported as a risk factor for aortic diameter enlargement, aortic rupture, and death in the chronic phase [2]. Therefore, obliterating the distal aortic false lumen after proximal aortic repair may improve outcomes.
Hofferberth et al. first reported the stent-assisted balloon-induced intimal disruption and relamination of aortic dissection (STABILISE) technique, which can obliterate the false lumen, in 2014 [3]. In the STABILISE technique, a stent graft is implanted at the proximal part of the aortic dissection to close the entry tear, followed by bare-metal aortic stent placement over the distal aortic dissection. Next, an aortic balloon catheter is dilated inside the stent graft and the bare stent to forcefully disrupt the intima and collapse the false lumen, immediately restoring uniluminal thoracoabdominal aortic flow.
This report describes our experience implementing the STABILISE technique for residual aortic dissection after complications from an ascending aorta and partial aortic arch replacement for acute TAAD.

Case presentation

A 60-year-old man presented at our hospital with sudden chest pain. The patient was a current smoker (five cigarettes per day) and had hypertension, dyslipidemia, and a history of vertebrobasilar artery dissection. A physical examination on arrival revealed coldness and pallor of the left lower limb. The left dorsal foot artery was not palpable, and the patient could not move their left lower limb. Computed tomography (CT) revealed TAAD extending to the bilateral external iliac arteries (EIA) with primary entry just above the Valsalve’s sinus. Cardiac tamponade or visceral artery malperfusion was not observed. The dissection involved the brachiocephalic artery (BCA), right common carotid artery (CCA), and right and left subclavian arteries (SCAs). The true lumen of the left EIA was severely collapsed because of the false lumen, and thus, a contrast exam of the common femoral artery (CFA) was delayed.
The patient underwent emergent ascending aorta and partial aortic arch replacement with BCA and left CCA reconstruction. The aorta was resected 1 cm above the sinotubular junction and then transected. A tear was observed in the lesser curvature of the aortic arch just below the left CCA, which was considered the primary entry. Then, the primary entry was resected, and the aortic arch was transected in zone 2. A 4-branched J-graft® (24 mm, Japan Lifeline, Tokyo, Japan) was selected, and the ascending aorta and partial aortic arch were replaced with the graft.
Immediately after surgery, the left femoral arterial pulse improved, and additional revascularization of the left lower extremity was deferred. There was no intermittent claudication after the surgery, and the postoperative course was good. However, on the 9th day after surgery, back pain and intermittent claudication of the left lower limb reemerged, so a follow-up CT scan was performed. The primary entry at the aortic arch was closed; however, a persistent antegrade false lumen flow in the descending thoracic aorta was present through the left SCA dissection, along with retrograde false lumen flow from the thoracoabdominal segment, resulting in enlargement of the aortic diameter to 42 mm at the distal arch and narrowing of the true lumen (Fig. 1 A–D). Furthermore, the left EIA had a significantly narrowed true lumen, and an ankle brachial pressure index (ABI) exam performed on the 10th day after surgery showed a decreased value of 0.53 (normal range: 0.90–1.40) on the left side. As for the visceral arteries, there was no dissection present, and only left renal artery was perfused from both true lumen with all other visceral arteries diverging from true lumen.
The patient underwent reoperation using the STABILISE technique on the 12th day after the initial surgery since the symptoms did not improve. The patient first underwent a debranching procedure from the left CCA to the left SCA bypass using 8-mm Propaten with a ring (WL Gore, Flagstaff, AZ, USA). Since the aortic diameter was 26 mm at the proximal landing zone (= J-graft) and 29–32 mm at the distal descending aorta, a Zenith TXD® 32–200 mm (Cook Medical, Bloomington, IN, USA) was selected and deployed just distal to the left CCA branch of the J-graft, closing the left SCA. An additional stent graft (Zenith Alpha® 32–80 mm, Cook Medical) was deployed with a 1.5 stent overlap from the previous stent graft. The first bare-metal aortic stent (Zenith Dissection® 36–123 mm, Cook Medical) was deployed from the second stent graft to just proximal to the celiac artery, and the second Zenith Dissection® 36–164 mm stent (Cook Medical) was deployed with a 25-mm overlap from the first Zenith dissection® stent to just above the aortic bifurcation. Pre-STABILISE angiography showed narrowing of the true lumen with all visceral arteries patent (Fig. 2A). The distal part of the stent graft was carefully dilated with a Coda Balloon (Cook Medical) and easily dilated to the intended diameter. The STABILISE technique seemed feasible from the initial dilation, and it was carefully performed over the entire length of the Zenith Dissection® (Fig. 2 B, C). Post-STABILISE angiography revealed favorable true lumen dilation and a completely obliterated false lumen (Fig. 2D). However, angiography also revealed occlusion of the left renal artery and bail-out stenting using the Express™ SD stent 6 mm × 18 mm (Boston Scientific, Marlborough, MA, USA) was performed. Next, aortic angiography was performed again, which confirmed the patency of all visceral arteries. Finally, angiography of the iliac arteries confirmed the residual left common iliac artery dissection and severe narrowing of the left EIA true lumen. To treat the EIA, an S.M.A.R.T.® stent 8 mm × 10 cm (Cordis Japan, Tokyo) was implanted from the ostium of the EIA; angiography confirmed good dilation of the EIA.
Follow-up CT was performed on the 1st day after the STABILISE technique (the 13th day after the initial aortic surgery). The true lumen of the aortic arch to the abdominal aorta was dilated, and the false lumen was completely obliterated where the STABILISE technique was performed (Fig. 3A, B). The patient’s postoperative course was uneventful, and his symptoms resolved. The ABI on the 3rd day after the STABILISE surgery (the 15th day after the initial aortic surgery) was 1.19 on the left side. The patient underwent rehabilitation and was discharged on the 9th day after the STABILISE surgery (the 21st day after the initial aortic surgery). A follow-up CT performed 6 months after the STABILISE technique showed a completely obliterated false lumen and no aortic enlargement (Fig. 3C, D).

Discussion and conclusions

Acute TAAD with malperfusion occurs in 20.5–33.7% of TAAD cases, of which visceral malperfusion occurs in less than 3%; however, the mortality rate for those with visceral malperfusion is up to 75% [46]. Treatment includes primary entry closure, total arch replacement plus open stent grafting, bypass or endovascular therapy for visceral branches, and simultaneous or early thoracic endovascular aortic repair (TEVAR) [7]. Bin et al. reported that total arch replacement plus open stent grafting might improve the prognosis in acute TAAD with malperfusion [8]. However, open stent grafts have been associated with an increased risk of paraplegia due to spinal cord infarctions. An open stent graft may also cause re-dissection due to stent graft-induced new entry (SINE) [9].
In this patient, total arch replacement plus open stent graft (or frozen elephant trunk) was an option. However, since our hospital’s strategy is to prioritize entry resection to keep the treatment simple and minimize surgical stress, only an ascending aorta and partial aortic arch replacement were performed, initially resolving the left limb malperfusion. Unfortunately, the residual false lumen flow resulted in recurrent back pain and intermittent claudication of the left lower limb, requiring additional treatment. The additional treatment options were conventional TEVAR with or without a bare-metal aortic stent or TEVAR with the STABILISE technique. TEVAR is an effective treatment for complicated type B aortic dissection (TBAD), such as rupture and malperfusion. The aim of TEVAR for TBAD is to close the entry tear, which causes a false lumen. TEVAR alone provides good remodeling in the descending thoracic aorta, and TEVAR with a bare-metal aortic stent, known as the PETTICOAT technique, also achieves good thoracic aortic remodeling and good true lumen expansion [10]. However, in both cases, the false lumen at the thoracoabdominal and abdominal aorta remains, as reentry cannot be treated in these segments.
A patent false lumen is associated with complications, such as aortic enlargement and SINE. In addition, impaired blood flow in visceral branches due to a residual false lumen after TEVAR can cause future problems. Furthermore, Faure et al. reported that TEVAR is associated with a 40% re-intervention rate [11]. A residual false lumen after proximal aortic repair is a major problem resulting in a poor prognosis. Therefore, obliteration of the distal aortic false lumen after proximal aortic repair may improve outcomes.
As previously reported, the STABILISE technique can disrupt the intima and obstruct the false lumen, immediately restoring the uniluminal thoracoabdominal aortic flow. In a study by Faure et al. (2018), all patients (n = 15) achieved technical success, and the aortic diameter did not expand during the follow-up period (range: 90–735 days). The STABILISE technique has also been used in patients with residual thoracoabdominal dissection after acute TAAD repair, achieving immediate and mid-term persistent remodeling of the thoracoabdominal aorta [12, 13]. In our patient, recurrent symptoms occurred from persistent false lumen flaws; thus, we applied the STABILISE technique, achieving good early results for at least 6 months.
The biggest limitation of the STABILISE technique is that it has not been widely utilized; thus, even though the short- and mid-term results are encouraging, the evidence is limited. For example, in a report by Hofferberth et al., the inclusion criteria were the presence of visceral malperfusion, dissection extending into the aortic branches, proximal false lumen growth (> 5 mm in 12 months), and true lumen collapse [3]. However, in our opinion, these criteria are over-indicated. We believe that most of those cases could have been treated with conventional TEVAR with or without a bare-metal aortic stent, and only persistent false lumen flaws with a high possibility of future complications should be indicated for the STABILISE technique. Therefore, more large-scale studies with long-term follow-ups are required. Furthermore, possibility of aortic injury always remains as we obliterate the intima by dilating a semi-compliant aortic balloon manually, and overdilation can easily occur. We believe development of non-compliant balloon dedicated for STABILISE technique using inflation device is warranted in the future to make this technique feasible for everyone.
In summary, we successfully performed the STABILISE technique on a patient with residual dissection after complications arose from aortic repair for acute TAAD.

Acknowledgements

Not applicable.

Declarations

The Tokyo Saiseikai Central Hospital IRB granted an exemption from requiring ethics approval.
Written informed consent was obtained from the patient for publication of this case report and accompanying images.

Competing interests

The authors declare that they have no competing interests.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Park KH, Lim C, Choi JH, Chung E, Choi SI, Chun EJ, et al. Midterm change of descending aortic false lumen after repair of acute type I dissection. Ann Thorac Surg. 2009;87(1):103–8.CrossRefPubMed Park KH, Lim C, Choi JH, Chung E, Choi SI, Chun EJ, et al. Midterm change of descending aortic false lumen after repair of acute type I dissection. Ann Thorac Surg. 2009;87(1):103–8.CrossRefPubMed
2.
Zurück zum Zitat Leontyev S, Haag F, Davierwala PM, Lehmkuhl L, Borger MA, Etz CD, et al. Postoperative changes in the distal residual aorta after surgery for acute type A aortic dissection: impact of false lumen patency and size of descending aorta. Thorac Cardiovasc Surg. 2017;65(2):90–8.PubMed Leontyev S, Haag F, Davierwala PM, Lehmkuhl L, Borger MA, Etz CD, et al. Postoperative changes in the distal residual aorta after surgery for acute type A aortic dissection: impact of false lumen patency and size of descending aorta. Thorac Cardiovasc Surg. 2017;65(2):90–8.PubMed
3.
Zurück zum Zitat Hofferberth SC, Nixon IK, Boston RC, McLachlan CS, Mossop PJ. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair: the STABILISE concept. J Thorac Cardiovasc Surg. 2014;147(4):1240–5.CrossRefPubMed Hofferberth SC, Nixon IK, Boston RC, McLachlan CS, Mossop PJ. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair: the STABILISE concept. J Thorac Cardiovasc Surg. 2014;147(4):1240–5.CrossRefPubMed
4.
Zurück zum Zitat Di Eusanio M, Trimarchi S, Patel HJ, Hutchison S, Suzuki T, Peterson MD, et al. Clinical presentation, management, and short-term outcome of patients with type A acute dissection complicated by mesenteric malperfusion: observations from the International Registry of Acute Aortic Dissection. J Thorac Cardiovasc Surg. 2013;145(2):385-90e1.CrossRefPubMed Di Eusanio M, Trimarchi S, Patel HJ, Hutchison S, Suzuki T, Peterson MD, et al. Clinical presentation, management, and short-term outcome of patients with type A acute dissection complicated by mesenteric malperfusion: observations from the International Registry of Acute Aortic Dissection. J Thorac Cardiovasc Surg. 2013;145(2):385-90e1.CrossRefPubMed
5.
Zurück zum Zitat Pacini D, Leone A, Belotti LM, Fortuna D, Gabbieri D, Zussa C, et al. Acute type A aortic dissection: significance of multiorgan malperfusion. Eur J Cardiothorac Surg. 2013;43(4):820–6.CrossRefPubMed Pacini D, Leone A, Belotti LM, Fortuna D, Gabbieri D, Zussa C, et al. Acute type A aortic dissection: significance of multiorgan malperfusion. Eur J Cardiothorac Surg. 2013;43(4):820–6.CrossRefPubMed
6.
Zurück zum Zitat Girdauskas E, Kuntze T, Borger MA, Falk V, Mohr FW. Surgical risk of preoperative malperfusion in acute type A aortic dissection. J Thorac Cardiovasc Surg. 2009;138(6):1363–9.CrossRefPubMed Girdauskas E, Kuntze T, Borger MA, Falk V, Mohr FW. Surgical risk of preoperative malperfusion in acute type A aortic dissection. J Thorac Cardiovasc Surg. 2009;138(6):1363–9.CrossRefPubMed
7.
Zurück zum Zitat Nienaber CA, Clough RE. Management of acute aortic dissection. Lancet. 2015;385(9970):800–11.CrossRefPubMed Nienaber CA, Clough RE. Management of acute aortic dissection. Lancet. 2015;385(9970):800–11.CrossRefPubMed
8.
Zurück zum Zitat Bin L, Fei J, Zhao L, Hong R, Yang W. Comparative effectiveness and safety of open triple-branched stent graft technique with stented elephant trunk implantation in treating Stanford type A aortic dissection: a trial sequential meta-analysis. J Card Surg. 2022;37(12):5210–7.CrossRefPubMedPubMedCentral Bin L, Fei J, Zhao L, Hong R, Yang W. Comparative effectiveness and safety of open triple-branched stent graft technique with stented elephant trunk implantation in treating Stanford type A aortic dissection: a trial sequential meta-analysis. J Card Surg. 2022;37(12):5210–7.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Kato M, Kuratani T, Kaneko M, Kyo S, Ohnishi K. The results of total arch graft implantation with open stent-graft placement for type A aortic dissection. J Thorac Cardiovasc Surg. 2002;124(3):531–40.CrossRefPubMed Kato M, Kuratani T, Kaneko M, Kyo S, Ohnishi K. The results of total arch graft implantation with open stent-graft placement for type A aortic dissection. J Thorac Cardiovasc Surg. 2002;124(3):531–40.CrossRefPubMed
10.
Zurück zum Zitat Lombardi JV, Cambria RP, Nienaber CA, Chiesa R, Mossop P, Haulon S, et al. Aortic remodeling after endovascular treatment of complicated type B aortic dissection with the use of a composite device design. J Vasc Surg. 2014;59(6):1544–54.CrossRefPubMed Lombardi JV, Cambria RP, Nienaber CA, Chiesa R, Mossop P, Haulon S, et al. Aortic remodeling after endovascular treatment of complicated type B aortic dissection with the use of a composite device design. J Vasc Surg. 2014;59(6):1544–54.CrossRefPubMed
11.
Zurück zum Zitat Faure EM, Canaud L, Agostini C, Shaub R, Boge G, Marty-ane C, et al. Reintervention after thoracic endovascular aortic repair of complicated aortic dissection. J Vasc Surg. 2014;59(2):327–33.CrossRefPubMed Faure EM, Canaud L, Agostini C, Shaub R, Boge G, Marty-ane C, et al. Reintervention after thoracic endovascular aortic repair of complicated aortic dissection. J Vasc Surg. 2014;59(2):327–33.CrossRefPubMed
12.
Zurück zum Zitat Faure EM, El Batti S, Abou Rjeili M, Julia P, Alsac JM. Mid-term outcomes of stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) in acute type B aortic dissection. Eur J Vasc Endovasc Surg. 2018;56(2):209–15.CrossRefPubMed Faure EM, El Batti S, Abou Rjeili M, Julia P, Alsac JM. Mid-term outcomes of stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) in acute type B aortic dissection. Eur J Vasc Endovasc Surg. 2018;56(2):209–15.CrossRefPubMed
13.
Zurück zum Zitat Faure EM, El Batti S, Sutter W, Bel A, Julia P, Achouh P, et al. Stent-assisted balloon-induced intimal disruption and relamination of distal remaining aortic dissection after acute DeBakey type I repair. J Thorac Cardiovasc Surg. 2019;157(6):2159–65.CrossRefPubMed Faure EM, El Batti S, Sutter W, Bel A, Julia P, Achouh P, et al. Stent-assisted balloon-induced intimal disruption and relamination of distal remaining aortic dissection after acute DeBakey type I repair. J Thorac Cardiovasc Surg. 2019;157(6):2159–65.CrossRefPubMed
Metadaten
Titel
A case of stent-assisted balloon-induced intimal disruption and relamination of distal remaining aortic dissection after the ascending aorta and aortic arch replacement for acute aortic dissection
verfasst von
Seito Shimizu
Yujiro Kawai
Yuki Horinouchi
Ayaka Yu
Masanori Hayashi
Kanako Kobayashi
Takahito Itoh
Naoki Fujimura
Hirohisa Harada
Satoshi Ohtsubo
Publikationsdatum
01.12.2023
Verlag
BioMed Central
Erschienen in
General Thoracic and Cardiovascular Surgery Cases / Ausgabe 1/2023
Elektronische ISSN: 2731-6203
DOI
https://doi.org/10.1186/s44215-023-00071-0

Weitere Artikel der Ausgabe 1/2023

General Thoracic and Cardiovascular Surgery Cases 1/2023 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.