A mask method to assess the uniformity of fat suppression in phantom studies

verfasst von: Yasuo Takatsu, Masafumi Nakamura, Kenichiro Yamamura, Satoshi Sawa, Masaki Asahara, Michitaka Honda, Tosiaki Miyati

Erschienen in: Radiological Physics and Technology | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Fat suppression is a technique used to suppress the signals from adipose tissues, during clinical evaluation of the tissues near the fat–tissue boundary. However, in cases where the scan area has a complicated shape, the effect of fat suppression may demonstrate poor uniformity, resulting in diagnosis-related difficulties. To improve the uniformity of fat suppression, phantom studies are more suitable than volunteer studies. In this study, we evaluated the reliability of the region of interest (ROI) dependency using an unevenness phantom, to develop a method to assess the uniformity of fat suppression while using whole magnetic resonance imaging by masking the surrounding phantom. We modulated different ROI sizes, which were eroded from 100% to approximately 50%, and observed that the normalized absolute average deviation and error increased with decreased ROI. Using our method, more objective, concrete, and accurate data could be obtained by including the whole-body phantom (whole poor uniformity area).
Literatur
1.
Zurück zum Zitat Bernstein MA, King KF, Zhou XJ. Chapter 4, spectral radiofrequency pulses. In: Bernstein MA, King KF, Zhou XJ, editors. Handbook of MRI pulse sequences. London: Elsevier Academic; 2004. p. 96–124.CrossRef Bernstein MA, King KF, Zhou XJ. Chapter 4, spectral radiofrequency pulses. In: Bernstein MA, King KF, Zhou XJ, editors. Handbook of MRI pulse sequences. London: Elsevier Academic; 2004. p. 96–124.CrossRef
2.
Zurück zum Zitat Bernstein MA, King KF, Zhou XJ. Chapter 5, spatial radiofrequency pulses. In: Bernstein MA, King KF, Zhou XJ, editors. Handbook of MRI pulse sequences. London: Elsevier Academic; 2004. p. 125–76.CrossRef Bernstein MA, King KF, Zhou XJ. Chapter 5, spatial radiofrequency pulses. In: Bernstein MA, King KF, Zhou XJ, editors. Handbook of MRI pulse sequences. London: Elsevier Academic; 2004. p. 125–76.CrossRef
3.
Zurück zum Zitat Bernstein MA, King KF, Zhou XJ. Chapter 6, adiabatic radiofrequency pulses. In: Zhou XJ, editor. Handbook of MRI pulse sequences. London: Elsevier Academic; 2004. p. 177–214.CrossRef Bernstein MA, King KF, Zhou XJ. Chapter 6, adiabatic radiofrequency pulses. In: Zhou XJ, editor. Handbook of MRI pulse sequences. London: Elsevier Academic; 2004. p. 177–214.CrossRef
4.
Zurück zum Zitat Reeder SB, Yu H, Johnson JW, Shimakawa A, Brittain JH, Pelc NJ, Beaulieu CF, Gold GE. T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation. J Magn Reson Imaging. 2006;24:825–32.CrossRef Reeder SB, Yu H, Johnson JW, Shimakawa A, Brittain JH, Pelc NJ, Beaulieu CF, Gold GE. T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation. J Magn Reson Imaging. 2006;24:825–32.CrossRef
5.
Zurück zum Zitat Takatsu Y, Nishiyama K, Miyati T, Miyano H, Kajihara M, Akasaka T. A comparison of shimming techniques for optimizing fat suppression in MR mammography. Radiol Phys Technol. 2013;6:486–91.CrossRef Takatsu Y, Nishiyama K, Miyati T, Miyano H, Kajihara M, Akasaka T. A comparison of shimming techniques for optimizing fat suppression in MR mammography. Radiol Phys Technol. 2013;6:486–91.CrossRef
6.
Zurück zum Zitat Rosen Y, Bloch BN, Lenkinski RE, Greenman RL, Marquis RP, Rofsky NM. 3T MR of the prostate: reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension. Magn Reson Med. 2007;57:898–904.CrossRef Rosen Y, Bloch BN, Lenkinski RE, Greenman RL, Marquis RP, Rofsky NM. 3T MR of the prostate: reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension. Magn Reson Med. 2007;57:898–904.CrossRef
7.
Zurück zum Zitat Takatsu Y, Kyotani K, Ueyama T, Miyati T, Yamamura K, Andou A. Assessment of the quality of breast MR imaging using the modified Dixon method and frequency-selective fat suppression: a phantom study. Magn Reson Med Sci. 2018;17:350–5.CrossRef Takatsu Y, Kyotani K, Ueyama T, Miyati T, Yamamura K, Andou A. Assessment of the quality of breast MR imaging using the modified Dixon method and frequency-selective fat suppression: a phantom study. Magn Reson Med Sci. 2018;17:350–5.CrossRef
8.
Zurück zum Zitat Mirowitz SA, Apicella P, Reinus WR, Hammerman AM. MR imaging of bone marrow lesions: relative conspicuousness on T1-weighted, fat-suppressed T2-weighted, and STIR images. Am J Roentgenol. 1994;162:215–21.CrossRef Mirowitz SA, Apicella P, Reinus WR, Hammerman AM. MR imaging of bone marrow lesions: relative conspicuousness on T1-weighted, fat-suppressed T2-weighted, and STIR images. Am J Roentgenol. 1994;162:215–21.CrossRef
9.
Zurück zum Zitat Le-Petross H, Kundra V, Szklaruk J, Wei W, Hortobagyi GN, Ma J. Fast three-dimensional dual echo dixon technique improves fat suppression in breast MRI. J Magn Reson Imaging. 2010;31:889–94.CrossRef Le-Petross H, Kundra V, Szklaruk J, Wei W, Hortobagyi GN, Ma J. Fast three-dimensional dual echo dixon technique improves fat suppression in breast MRI. J Magn Reson Imaging. 2010;31:889–94.CrossRef
10.
Zurück zum Zitat National Electrical Manufacturers Association, Determination of image uniformity in diagnostic magnetic resonance images. NEMA Standards Publication MS 3-2008 (NEMA, Rosslyn, VA, 2008), 2008. pp. 1–17. National Electrical Manufacturers Association, Determination of image uniformity in diagnostic magnetic resonance images. NEMA Standards Publication MS 3-2008 (NEMA, Rosslyn, VA, 2008), 2008. pp. 1–17.
11.
Zurück zum Zitat Otsu N. A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern. 1979;9(1):62–6.CrossRef Otsu N. A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern. 1979;9(1):62–6.CrossRef
12.
Zurück zum Zitat Kanda Y. Investigation of the freely available easy-to-use software‘EZR’ for medical statistics. Bone Marrow Transpl. 2013;48:452–8.CrossRef Kanda Y. Investigation of the freely available easy-to-use software‘EZR’ for medical statistics. Bone Marrow Transpl. 2013;48:452–8.CrossRef
13.
Zurück zum Zitat Takatsu Y, Akasaka T, Miyati T. The Dixon technique and the frequency-selective fat suppression technique in three-dimensional T1 weighted MRI of the liver: a comparison of contrast-to-noise ratios of hepatocellular carcinomas-to-liver. Br J Radiol. 2015;88:20150117.CrossRef Takatsu Y, Akasaka T, Miyati T. The Dixon technique and the frequency-selective fat suppression technique in three-dimensional T1 weighted MRI of the liver: a comparison of contrast-to-noise ratios of hepatocellular carcinomas-to-liver. Br J Radiol. 2015;88:20150117.CrossRef
Metadaten
Titel
A mask method to assess the uniformity of fat suppression in phantom studies
verfasst von
Yasuo Takatsu
Masafumi Nakamura
Kenichiro Yamamura
Satoshi Sawa
Masaki Asahara
Michitaka Honda
Tosiaki Miyati
Publikationsdatum
17.08.2019
Verlag
Springer Singapore
Erschienen in
Radiological Physics and Technology / Ausgabe 4/2019
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00531-9

Weitere Artikel der Ausgabe 4/2019

Radiological Physics and Technology 4/2019 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.