Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 1/2014

01.01.2014 | Original Article

A preregistered STAMP method for image-guided temporal bone surgery

verfasst von: Masamichi Oka, Byunghyun Cho, Nozomu Matsumoto, Jaesung Hong, Misaki Jinnouchi, Riichi Ouchida, Shizuo Komune, Makoto Hashizume

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

Objectives

   Image-guided otological surgeries require minimal invasiveness and high accuracy, and these two factors usually compete with each other. Our recently developed registration method, called the STAMP method, showed minimal invasiveness with accuracy comparable to that of the current more invasive registration methods used in image-guided temporal bone surgery. However, surgeons perceived the STAMP method as complex and time-consuming.

Methods

   We modified our STAMP method to further simplify the surgeon’s tasks in the operating room. We attached an optical tracking target on the STAMP plate and registered the plate in an IGS system before surgery, outside the operating room. The registration was completed in the operating room by finishing the final simple task, which was to hold the preregistered STAMP plate still on the patient’s temporal bone. We tested this modified preregistered STAMP method in simulation surgery and actual surgeries. The registration times and errors of the STAMP method and preregistered STAMP method were compared.

Results

   The proposed new preregistered STAMP method significantly reduced the registration time in the operating room without compromising the registration accuracy.

Conclusions

   The preregistered STAMP method significantly improved the original STAMP method in terms of time and convenience. It is now considered to be one of the easiest and quickest registrations for image-guided temporal bone surgery. Because most of the critical processes of registration can be completed in the laboratory, the registration task in the operating room is therefore greatly simplified, thus allowing surgeons to concentrate more on the surgery itself.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
3.
Zurück zum Zitat Grayeli AB, Esquia-Medina G, Nguyen Y, Mazalaigue S, Vellin JF, Lombard B, Kalamarides M, Ferrary E, Sterkers O (2009) Use of anatomic or invasive markers in association with skin surface registration in image-guided surgery of the temporal bone. Acta Otolaryngol 129(4):405–410. doi:10.1080/00016480802579025 PubMedCrossRef Grayeli AB, Esquia-Medina G, Nguyen Y, Mazalaigue S, Vellin JF, Lombard B, Kalamarides M, Ferrary E, Sterkers O (2009) Use of anatomic or invasive markers in association with skin surface registration in image-guided surgery of the temporal bone. Acta Otolaryngol 129(4):405–410. doi:10.​1080/​0001648080257902​5 PubMedCrossRef
5.
6.
Zurück zum Zitat Ledderose GJ, Hagedorn H, Spiegl K, Leunig A, Stelter K (2012) Image guided surgery of the lateral skull base: testing a new dental splint registration device. Comput Aided Surg 17(1):13–20. doi:10.3109/10929088.2011.632783 Ledderose GJ, Hagedorn H, Spiegl K, Leunig A, Stelter K (2012) Image guided surgery of the lateral skull base: testing a new dental splint registration device. Comput Aided Surg 17(1):13–20. doi:10.​3109/​10929088.​2011.​632783
8.
Zurück zum Zitat Hong J, Matsumoto N, Ouchida R, Komune S, Hashizume M (2009) Medical navigation system for otologic surgery based on hybrid registration and virtual intraoperative computed tomography. IEEE Trans Biomed Eng 56(2):426–432. doi:10.1109/TBME.2008.2008168 PubMedCrossRef Hong J, Matsumoto N, Ouchida R, Komune S, Hashizume M (2009) Medical navigation system for otologic surgery based on hybrid registration and virtual intraoperative computed tomography. IEEE Trans Biomed Eng 56(2):426–432. doi:10.​1109/​TBME.​2008.​2008168 PubMedCrossRef
10.
Zurück zum Zitat Labadie RF, Mitchell J, Balachandran R, Fitzpatrick JM (2009) Customized, rapid-production microstereotactic table for surgical targeting: description of concept and in vitro validation. Int J Comput Assist Radiol Surg 4(3):273–280. doi:10.1007/s11548-009-0292-3 PubMedCrossRef Labadie RF, Mitchell J, Balachandran R, Fitzpatrick JM (2009) Customized, rapid-production microstereotactic table for surgical targeting: description of concept and in vitro validation. Int J Comput Assist Radiol Surg 4(3):273–280. doi:10.​1007/​s11548-009-0292-3 PubMedCrossRef
12.
Zurück zum Zitat Grauvogel TD, Grauvogel J, Arndt S, Berlis A, Maier W (2012) Is there an equivalence of non-invasive to invasive referenciation in computer-aided surgery? Eur Arch Otorhinolaryngol 269(10):2285–2290. doi:10.1007/s00405-012-2023-6 PubMedCrossRef Grauvogel TD, Grauvogel J, Arndt S, Berlis A, Maier W (2012) Is there an equivalence of non-invasive to invasive referenciation in computer-aided surgery? Eur Arch Otorhinolaryngol 269(10):2285–2290. doi:10.​1007/​s00405-012-2023-6 PubMedCrossRef
13.
15.
Zurück zum Zitat Suzuki M, Hagiwara A, Ogawa Y, Ono H (2007) Rapid-prototyped temporal bone and inner-ear models replicated by adjusting computed tomography thresholds. J Laryngol Otol 121(11):1025–1028. doi:10.1017/S0022215107006706 Suzuki M, Hagiwara A, Ogawa Y, Ono H (2007) Rapid-prototyped temporal bone and inner-ear models replicated by adjusting computed tomography thresholds. J Laryngol Otol 121(11):1025–1028. doi:10.​1017/​S002221510700670​6
16.
Zurück zum Zitat Manzey D, Luz M, Mueller S, Dietz A, Meixensberger J, Strauss G (2011) Automation in surgery: the impact of navigated-control assistance on performance, workload, situation awareness, and acquisition of surgical skills. Hum Factors 53(6):584–599 Manzey D, Luz M, Mueller S, Dietz A, Meixensberger J, Strauss G (2011) Automation in surgery: the impact of navigated-control assistance on performance, workload, situation awareness, and acquisition of surgical skills. Hum Factors 53(6):584–599
18.
Zurück zum Zitat Metson R, Cosenza M, Gliklich RE, Montgomery WW (1999) The role of image-guidance systems for head and neck surgery. Arch Otolaryngol Head Neck Surg 125(10):1100–1104PubMedCrossRef Metson R, Cosenza M, Gliklich RE, Montgomery WW (1999) The role of image-guidance systems for head and neck surgery. Arch Otolaryngol Head Neck Surg 125(10):1100–1104PubMedCrossRef
19.
Zurück zum Zitat Wiles AD, Thompson DG, Frantz DD (2004) Accuracy assessment and interpretation for optical tracking systems. Proc Soc Photo-Opt Ins 5367:421–432. doi:10.1117/12.536128 Wiles AD, Thompson DG, Frantz DD (2004) Accuracy assessment and interpretation for optical tracking systems. Proc Soc Photo-Opt Ins 5367:421–432. doi:10.​1117/​12.​536128
21.
Zurück zum Zitat Chinzei K (2007) Clinical use of surgical navigation systems—questionnaire results (1). J JSCAS 9(2):115–134 (in Japanese) Chinzei K (2007) Clinical use of surgical navigation systems—questionnaire results (1). J JSCAS 9(2):115–134 (in Japanese)
22.
Zurück zum Zitat Manzey D, Rottger S, Bahner-Heyne JE, Schulze-Kissing D, Dietz A, Meixensberger J, Strauss G (2009) Image-guided navigation: the surgeon’s perspective on performance consequences and human factors issues. Int J Med Robot 5(3):297–308. doi:10.1002/rcs.261 PubMed Manzey D, Rottger S, Bahner-Heyne JE, Schulze-Kissing D, Dietz A, Meixensberger J, Strauss G (2009) Image-guided navigation: the surgeon’s perspective on performance consequences and human factors issues. Int J Med Robot 5(3):297–308. doi:10.​1002/​rcs.​261 PubMed
23.
Zurück zum Zitat Uneri A, Schafer S, Mirota DJ, Nithiananthan S, Otake Y, Taylor RH, Gallia GL, Khanna AJ, Lee S, Reh DD, Siewerdsen JH (2012) TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery. Int J Comput Assist Radiol Surg 7(1):159–173. doi:10.1007/s11548-011-0636-7 PubMedCrossRef Uneri A, Schafer S, Mirota DJ, Nithiananthan S, Otake Y, Taylor RH, Gallia GL, Khanna AJ, Lee S, Reh DD, Siewerdsen JH (2012) TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery. Int J Comput Assist Radiol Surg 7(1):159–173. doi:10.​1007/​s11548-011-0636-7 PubMedCrossRef
24.
Zurück zum Zitat Oka M, Cho B, Matsumoto N, Hong J, Komune S, Hashizume M (2011) Pre-registered STAMP method for instant registration in image-guided temporal bone surgery. Int J Comput Assist Radiol Surg 6(Suppl 1):S123–S126 Oka M, Cho B, Matsumoto N, Hong J, Komune S, Hashizume M (2011) Pre-registered STAMP method for instant registration in image-guided temporal bone surgery. Int J Comput Assist Radiol Surg 6(Suppl 1):S123–S126
25.
Zurück zum Zitat Bettschart C, Kruse A, Matthews F, Zemann W, Obwegeser JA, Gratz KW, Lubbers HT (2012) Point-to-point registration with mandibulo-maxillary splint in open and closed jaw position. Evaluation of registration accuracy for computer-aided surgery of the mandible. J Craniomaxillofac Surg 40(7):592–598. doi:10.1016/j.jcms.2011.10.016 PubMedCrossRef Bettschart C, Kruse A, Matthews F, Zemann W, Obwegeser JA, Gratz KW, Lubbers HT (2012) Point-to-point registration with mandibulo-maxillary splint in open and closed jaw position. Evaluation of registration accuracy for computer-aided surgery of the mandible. J Craniomaxillofac Surg 40(7):592–598. doi:10.​1016/​j.​jcms.​2011.​10.​016 PubMedCrossRef
Metadaten
Titel
A preregistered STAMP method for image-guided temporal bone surgery
verfasst von
Masamichi Oka
Byunghyun Cho
Nozomu Matsumoto
Jaesung Hong
Misaki Jinnouchi
Riichi Ouchida
Shizuo Komune
Makoto Hashizume
Publikationsdatum
01.01.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 1/2014
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0916-5

Weitere Artikel der Ausgabe 1/2014

International Journal of Computer Assisted Radiology and Surgery 1/2014 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.