Skip to main content
Erschienen in: Journal of Digital Imaging 1/2008

01.03.2008

An Algorithm for Tracking Microcatheters in Fluoroscopy

verfasst von: Akihiro Takemura, Kenneth R. Hoffmann, Masayuki Suzuki, Zhou Wang, Hussain S. Rangwala, Hajime Harauchi, Stephen Rudin, Tokuo Umeda

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 1/2008

Einloggen, um Zugang zu erhalten

Abstract

Currently, a large number of endovascular interventions are performed for treatment of intracranial aneurysms. For these treatments, correct positioning of microcatheter tips, microguide wire tips, or coils is essential. Techniques to detect such devices may facilitate endovascular interventions. In this paper, we describe an algorithm for tracking of microcatheter tips during fluoroscopically guided neuroendovascular interventions. A sequence of fluoroscopic images (1,024 × 1,024 × 12 bits) was acquired using a C-arm angiography system as a microcatheter was passed through a carotid phantom which was on top of a head phantom. The carotid phantom was a silicone cylinder containing a simulated vessel with the shape and curvatures of the internal carotid artery. The head phantom consisted of a human skull and tissue-equivalent material. To detect the microcatheter in a given fluoroscopic frame, a background image consisting of an average of the four previous frames is subtracted from the current frame, the resulting image is filtered using a matched filter, and the position of maximum intensity in the filtered image is taken as the catheter tip position in the current frame. The distance between the tracked position and the correct position (error distance) was measured in each of the fluoroscopic images. The mean and standard deviation of the error distance values were 0.277 mm (1.59 pixels) and 0.26 mm (1.5 pixels), respectively. The error distance was less than 3 pixels in the 93.0% frames. Although the algorithm intermittently failed to correctly detect the catheter, the algorithm recovered the catheter in subsequent frames.
Literatur
1.
Zurück zum Zitat Kuehne T, Saeed M, Higgins CB, et al: Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology 226:475–481, 2003PubMedCrossRef Kuehne T, Saeed M, Higgins CB, et al: Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology 226:475–481, 2003PubMedCrossRef
2.
Zurück zum Zitat Buecker A, Neuerburg JM, Adam GB, et al: Real-time MR fluoroscopy for MR-guided iliac artery stent placement. J Magn Reson Imaging 12:616–622, 2000PubMedCrossRef Buecker A, Neuerburg JM, Adam GB, et al: Real-time MR fluoroscopy for MR-guided iliac artery stent placement. J Magn Reson Imaging 12:616–622, 2000PubMedCrossRef
3.
Zurück zum Zitat Dion YM, Ben El Kadi H, Boudoux C, et al: Endovascular procedures under near-real-time magnetic resonance imaging guidance: an experimental feasibility study. J Vasc Surg 32:1006–1014, 2000PubMedCrossRef Dion YM, Ben El Kadi H, Boudoux C, et al: Endovascular procedures under near-real-time magnetic resonance imaging guidance: an experimental feasibility study. J Vasc Surg 32:1006–1014, 2000PubMedCrossRef
4.
Zurück zum Zitat Quick HH, Kuehl H, Kaiser G, et al: Interventional MR angiography with a floating table. Radiology 229:598–602, 2003PubMedCrossRef Quick HH, Kuehl H, Kaiser G, et al: Interventional MR angiography with a floating table. Radiology 229:598–602, 2003PubMedCrossRef
5.
Zurück zum Zitat Quick HH, Ladd ME, Nanz D, et al: Vascular stents as RF antennas for intravascular MR guidance and imaging. Magn Reson Med 42:738–745, 1999PubMedCrossRef Quick HH, Ladd ME, Nanz D, et al: Vascular stents as RF antennas for intravascular MR guidance and imaging. Magn Reson Med 42:738–745, 1999PubMedCrossRef
6.
Zurück zum Zitat Strother CM, Unal O, Frayne R, et al: Endovascular treatment of experimental canine aneurysms: feasibility with MR imaging guidance. Radiology 215:516–519, 2000PubMed Strother CM, Unal O, Frayne R, et al: Endovascular treatment of experimental canine aneurysms: feasibility with MR imaging guidance. Radiology 215:516–519, 2000PubMed
7.
Zurück zum Zitat Wittkampf FH, Wever EF, Derksen R, et al: Accuracy of the LocaLisa system in catheter ablation procedures. J Electrocardiol 32(Supplement 7):12, 1999 Wittkampf FH, Wever EF, Derksen R, et al: Accuracy of the LocaLisa system in catheter ablation procedures. J Electrocardiol 32(Supplement 7):12, 1999
8.
Zurück zum Zitat Salem RR, Ward BA, Ravikumar TS: A new peripherally implanted subcutaneous permanent central venous access device for patients requiring chemotherapy. J Clin Oncol 11:2181–2185, 1993PubMed Salem RR, Ward BA, Ravikumar TS: A new peripherally implanted subcutaneous permanent central venous access device for patients requiring chemotherapy. J Clin Oncol 11:2181–2185, 1993PubMed
9.
Zurück zum Zitat Starkhammar H, Bengtsson M, Kay DA: Cath-Finder catheter tracking system: a new device for positioning of centeral venous catheters. Early experience from implantation of brachial portal systems. Acta Anaesthesiol Scand 34:296–300, 1990PubMedCrossRef Starkhammar H, Bengtsson M, Kay DA: Cath-Finder catheter tracking system: a new device for positioning of centeral venous catheters. Early experience from implantation of brachial portal systems. Acta Anaesthesiol Scand 34:296–300, 1990PubMedCrossRef
10.
Zurück zum Zitat Meyer SA, Wolf PD: Registration of three-dimensional cardiac catheter models to single-plane fluoroscopic images. IEEE Trans Biomed Eng 46:1471–1479, 1999PubMedCrossRef Meyer SA, Wolf PD: Registration of three-dimensional cardiac catheter models to single-plane fluoroscopic images. IEEE Trans Biomed Eng 46:1471–1479, 1999PubMedCrossRef
11.
Zurück zum Zitat Esthappan J, Kupinsky M, Hoffmann KR: Estimation of catheter orientations from single-plane x-ray images. Proc SPIE 3976:28–36, 2000CrossRef Esthappan J, Kupinsky M, Hoffmann KR: Estimation of catheter orientations from single-plane x-ray images. Proc SPIE 3976:28–36, 2000CrossRef
12.
Zurück zum Zitat Jabri KN, Wilson DL: Detection improvement in spatially filtered x-ray fluoroscopy image sequences. J Opt Soc Am A Opt Image Sci Vis 16:742–749, 1999PubMedCrossRef Jabri KN, Wilson DL: Detection improvement in spatially filtered x-ray fluoroscopy image sequences. J Opt Soc Am A Opt Image Sci Vis 16:742–749, 1999PubMedCrossRef
13.
Zurück zum Zitat Wilson DL, Jabri KN, Aufrichtig R: Perception of temporally filtered X-ray fluoroscopy images. IEEE Trans Med Imag 18:22–31, 1999CrossRef Wilson DL, Jabri KN, Aufrichtig R: Perception of temporally filtered X-ray fluoroscopy images. IEEE Trans Med Imag 18:22–31, 1999CrossRef
14.
Zurück zum Zitat Xue P, Wilson DL: Detection of moving objects in pulsed-x-ray fluoroscopy. J Opt Soc Am A Opt Image Sci Vis 15:375–388, 1998PubMedCrossRef Xue P, Wilson DL: Detection of moving objects in pulsed-x-ray fluoroscopy. J Opt Soc Am A Opt Image Sci Vis 15:375–388, 1998PubMedCrossRef
15.
Zurück zum Zitat Xue P, Wilson DL: Pulsed fluoroscopy detectability from interspersed adaptive forced-choice measurements. Med Phys 23:1833–1843, 1996PubMedCrossRef Xue P, Wilson DL: Pulsed fluoroscopy detectability from interspersed adaptive forced-choice measurements. Med Phys 23:1833–1843, 1996PubMedCrossRef
16.
Zurück zum Zitat Baert SAM, Viergever MA, Niessen WJ: Guide-wire tracking during endovascular interventions. IEEE Trans Med Imag 22:965–972, 2003CrossRef Baert SAM, Viergever MA, Niessen WJ: Guide-wire tracking during endovascular interventions. IEEE Trans Med Imag 22:965–972, 2003CrossRef
17.
Zurück zum Zitat Palti-Wasserman D, Brukstein AM, Beyar RP: Identifying and tracking a guide wire in the coronary arteries during angioplasty from X-ray images. IEEE Trans Biomed Eng 44:152–1464, 1997PubMedCrossRef Palti-Wasserman D, Brukstein AM, Beyar RP: Identifying and tracking a guide wire in the coronary arteries during angioplasty from X-ray images. IEEE Trans Biomed Eng 44:152–1464, 1997PubMedCrossRef
18.
Zurück zum Zitat Baert SAM, van de Kraats EB, van Walsum T, et al: Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature. IEEE Trans Med Imag 22:1252–1258, 2003CrossRef Baert SAM, van de Kraats EB, van Walsum T, et al: Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature. IEEE Trans Med Imag 22:1252–1258, 2003CrossRef
19.
Zurück zum Zitat Takemura A, Harauchi H, Suzuki M, et al: An algorithm for mapping the catheter tip position on a fluorograph to the three-dimensional position in magnetic resonance angiography volume data. Phys Med Biol 48:2697–2711, 2003PubMedCrossRef Takemura A, Harauchi H, Suzuki M, et al: An algorithm for mapping the catheter tip position on a fluorograph to the three-dimensional position in magnetic resonance angiography volume data. Phys Med Biol 48:2697–2711, 2003PubMedCrossRef
20.
Zurück zum Zitat Cucchiara R, Grana C, Piccardi M, et al: Improving shadow suppression in moving object detection with HSV color information. Proc IEEE Intelligent Transportation System Conference 334–339, 2001 Cucchiara R, Grana C, Piccardi M, et al: Improving shadow suppression in moving object detection with HSV color information. Proc IEEE Intelligent Transportation System Conference 334–339, 2001
21.
Zurück zum Zitat Prati A, Mikic I, Grana C, et al: Shadow detection algorithms for traffic flow analysis: a comparative study. Proc IEEE Intelligent Transportation System Conference 340–345, 2001 Prati A, Mikic I, Grana C, et al: Shadow detection algorithms for traffic flow analysis: a comparative study. Proc IEEE Intelligent Transportation System Conference 340–345, 2001
22.
Zurück zum Zitat Haritaoglu I, Harwood D, Davis LS: W4: real-time surveillance of people and their activities. IEEE Trans Pattern Anal Mach Intell 22:809–830, 2000CrossRef Haritaoglu I, Harwood D, Davis LS: W4: real-time surveillance of people and their activities. IEEE Trans Pattern Anal Mach Intell 22:809–830, 2000CrossRef
23.
Zurück zum Zitat Ivanov Y, Bobick A, Liu J: Fast lighting independent background subtraction. Int J Comput Vis 37:199–207, 2000CrossRef Ivanov Y, Bobick A, Liu J: Fast lighting independent background subtraction. Int J Comput Vis 37:199–207, 2000CrossRef
Metadaten
Titel
An Algorithm for Tracking Microcatheters in Fluoroscopy
verfasst von
Akihiro Takemura
Kenneth R. Hoffmann
Masayuki Suzuki
Zhou Wang
Hussain S. Rangwala
Hajime Harauchi
Stephen Rudin
Tokuo Umeda
Publikationsdatum
01.03.2008
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2008
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-007-9016-9

Weitere Artikel der Ausgabe 1/2008

Journal of Digital Imaging 1/2008 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.