Purpose

The registration of preoperative 3D images to intra-operative laparoscopic 2D images is one of the main concerns for augmented reality in computer-assisted surgery. For laparoscopic liver surgery, while several algorithms have been proposed, there is neither a public dataset nor a systematic evaluation methodology to quantitatively evaluate registration accuracy.

Method

Our main contribution is to provide such a dataset with an in vivo porcine model. It is used to evaluate a state-of-the-art registration algorithm that is capable of simultaneous registration and soft-body collision reasoning.

Results

The dataset consists of 13 deformed liver states, with corresponding exploration videos and interventional CT acquisitions with 60 small artificial fiducials located on the surface of the liver and distributed within the parenchyma, where a precise registration is crucial for augmented reality. This dataset will be made public. Using this dataset, we show that collision reasoning improves performance of registration for strong deformation and independent lobe motion.

Conclusion

This dataset addresses the lack of public datasets in this field. As an example of use, we present and evaluate a state-of-the-art energy-based approach and a novel extension that handles self-collisions.
Literatur
1.
Zurück zum Zitat Adagolodjo Y, Trivisonne R, Haouchine N, Cotin S, Courtecuisse H (2017) Silhouette-based pose estimation for deformable organs application to surgical augmented reality. In: Intelligent robots and systems (IROS). IEEE, pp 539–544 Adagolodjo Y, Trivisonne R, Haouchine N, Cotin S, Courtecuisse H (2017) Silhouette-based pose estimation for deformable organs application to surgical augmented reality. In: Intelligent robots and systems (IROS). IEEE, pp 539–544
2.
Zurück zum Zitat Allard J, Cotin S, Faure F, Bensoussan PJ, Poyer F, Duriez C, Delingette H, Grisoni L (2007) Sofa—an open source framework for medical simulation. In: MMVR 15-Medicine meets virtual reality, vol 125. IOP Press, pp 13–18 Allard J, Cotin S, Faure F, Bensoussan PJ, Poyer F, Duriez C, Delingette H, Grisoni L (2007) Sofa—an open source framework for medical simulation. In: MMVR 15-Medicine meets virtual reality, vol 125. IOP Press, pp 13–18
3.
Zurück zum Zitat Amberg B, Romdhani S, Vetter T (2007) Optimal step nonrigid ICP algorithms for surface registration. In: IEEE conference on CVPR’07. IEEE, pp 1–8 Amberg B, Romdhani S, Vetter T (2007) Optimal step nonrigid ICP algorithms for surface registration. In: IEEE conference on CVPR’07. IEEE, pp 1–8
4.
Zurück zum Zitat Clements LW, Chapman WC, Dawant BM, Galloway RL Jr, Miga MI (2008) Robust surface registration using salient anatomical features for image-guided liver surgery: algorithm and validation. Med Phys 35(6Part1):2528–2540CrossRefPubMedPubMedCentral Clements LW, Chapman WC, Dawant BM, Galloway RL Jr, Miga MI (2008) Robust surface registration using salient anatomical features for image-guided liver surgery: algorithm and validation. Med Phys 35(6Part1):2528–2540CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Collins JA, Weis JA, Heiselman JS, Clements LW, Simpson AL, Jarnagin WR, Miga MI (2017) Improving registration robustness for image-guided liver surgery in a novel human-to-phantom data framework. IEEE Trans Med Imaging 36(7):1502–1510CrossRefPubMedPubMedCentral Collins JA, Weis JA, Heiselman JS, Clements LW, Simpson AL, Jarnagin WR, Miga MI (2017) Improving registration robustness for image-guided liver surgery in a novel human-to-phantom data framework. IEEE Trans Med Imaging 36(7):1502–1510CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Collins T, Bartoli A (2015) [POSTER] Realtime shape-from-template: system and applications. In: 2015 IEEE international symposium on ISMAR. IEEE, pp 116–119 Collins T, Bartoli A (2015) [POSTER] Realtime shape-from-template: system and applications. In: 2015 IEEE international symposium on ISMAR. IEEE, pp 116–119
7.
Zurück zum Zitat Collins T, Bartoli A, Bourdel N, Canis M (2016) Robust, real-time, dense and deformable 3D organ tracking in laparoscopic videos. In: MICCAI. Springer, pp 404–412 Collins T, Bartoli A, Bourdel N, Canis M (2016) Robust, real-time, dense and deformable 3D organ tracking in laparoscopic videos. In: MICCAI. Springer, pp 404–412
8.
Zurück zum Zitat Collins T, Chauvet P, Debize C, Pizarro D, Bartoli A, Canis M, Bourdel N (2016) A system for augmented reality guided laparoscopic tumour resection with quantitative ex-vivo user evaluation. In: CARE. Springer, pp 114–126 Collins T, Chauvet P, Debize C, Pizarro D, Bartoli A, Canis M, Bourdel N (2016) A system for augmented reality guided laparoscopic tumour resection with quantitative ex-vivo user evaluation. In: CARE. Springer, pp 114–126
9.
Zurück zum Zitat Cour T, Srinivasan P, Shi J (2006) Balanced graph matching. In: Proceedings of the 19th international conference on neural information processing systems. MIT Press, pp 313–320 Cour T, Srinivasan P, Shi J (2006) Balanced graph matching. In: Proceedings of the 19th international conference on neural information processing systems. MIT Press, pp 313–320
11.
Zurück zum Zitat Fabian S, Spinczyk D (2018) Target registration error minimization for minimally invasive interventions involving deformable organs. Comput Med Imaging Graph 65:4–10CrossRefPubMed Fabian S, Spinczyk D (2018) Target registration error minimization for minimally invasive interventions involving deformable organs. Comput Med Imaging Graph 65:4–10CrossRefPubMed
12.
Zurück zum Zitat Fitzpatrick JM (2009) Fiducial registration error and target registration error are uncorrelated. In: Medical imaging 2009—visualization, image-guided procedures, and modeling, vol 7261. International Society for Optics and Photonics, p 726102 Fitzpatrick JM (2009) Fiducial registration error and target registration error are uncorrelated. In: Medical imaging 2009—visualization, image-guided procedures, and modeling, vol 7261. International Society for Optics and Photonics, p 726102
13.
Zurück zum Zitat Haouchine N, Dequidt J, Peterlik I, Kerrien E, Berger MO, Cotin S (2013) Image-guided simulation of heterogeneous tissue deformation for augmented reality during hepatic surgery. In: 2013 IEEE international symposium on ISMAR. IEEE Haouchine N, Dequidt J, Peterlik I, Kerrien E, Berger MO, Cotin S (2013) Image-guided simulation of heterogeneous tissue deformation for augmented reality during hepatic surgery. In: 2013 IEEE international symposium on ISMAR. IEEE
14.
Zurück zum Zitat Haouchine N, Roy F, Untereiner L, Cotin S (2016) Using contours as boundary conditions for elastic registration during minimally invasive hepatic surgery. In: 2016 IEEE/RSJ international conference on intelligent robots and systems (IROS). IEEE Haouchine N, Roy F, Untereiner L, Cotin S (2016) Using contours as boundary conditions for elastic registration during minimally invasive hepatic surgery. In: 2016 IEEE/RSJ international conference on intelligent robots and systems (IROS). IEEE
15.
Zurück zum Zitat Heiselman JS, Collins JA, Clements LW, Weis JA, Simpson AL, Geevarghese SK, Kingham TP, Jarnagin WR, Miga MI (2018) Nonrigid registration for laparoscopic liver surgery using sparse intraoperative data. In: Medical imaging 2018—image-guided procedures, robotic interventions, and modeling, vol 10576. International Society for Optics and Photonics, p 105760D Heiselman JS, Collins JA, Clements LW, Weis JA, Simpson AL, Geevarghese SK, Kingham TP, Jarnagin WR, Miga MI (2018) Nonrigid registration for laparoscopic liver surgery using sparse intraoperative data. In: Medical imaging 2018—image-guided procedures, robotic interventions, and modeling, vol 10576. International Society for Optics and Photonics, p 105760D
16.
Zurück zum Zitat Kerdok AE, Cotin SM, Ottensmeyer MP, Galea AM, Howe RD, Dawson SL (2003) Truth cube: establishing physical standards for soft tissue simulation. Med Image Anal 7(3):283–291CrossRefPubMed Kerdok AE, Cotin SM, Ottensmeyer MP, Galea AM, Howe RD, Dawson SL (2003) Truth cube: establishing physical standards for soft tissue simulation. Med Image Anal 7(3):283–291CrossRefPubMed
17.
Zurück zum Zitat Klosowski JT, Held M, Mitchell JS, Sowizral H, Zikan K (1998) Efficient collision detection using bounding volume hierarchies of k-DOPs. IEEE TVCG 4:21–36 Klosowski JT, Held M, Mitchell JS, Sowizral H, Zikan K (1998) Efficient collision detection using bounding volume hierarchies of k-DOPs. IEEE TVCG 4:21–36
18.
Zurück zum Zitat Koo B, Özgür E, Le Roy B, Buc E, Bartoli A (2017) Deformable registration of a preoperative 3D liver volume to a laparoscopy image using contour and shading cues. In: MICCAI. Springer, pp 326–334 Koo B, Özgür E, Le Roy B, Buc E, Bartoli A (2017) Deformable registration of a preoperative 3D liver volume to a laparoscopy image using contour and shading cues. In: MICCAI. Springer, pp 326–334
19.
Zurück zum Zitat Mahmoud N, Cirauqui I, Hostettler A, Doignon C, Soler L, Marescaux J, Montiel J (2016) Orbslam-based endoscope tracking and 3D reconstruction. In: CARE. Springer, pp 72–83 Mahmoud N, Cirauqui I, Hostettler A, Doignon C, Soler L, Marescaux J, Montiel J (2016) Orbslam-based endoscope tracking and 3D reconstruction. In: CARE. Springer, pp 72–83
20.
Zurück zum Zitat Modrzejewski R, Collins T, Bartoli A, Hostettler A, Marescaux J (2018) Soft-body registration of pre-operative 3D models to intra-operative RGBD partial body scans. In: MICCAI. Springer, pp 39–46 Modrzejewski R, Collins T, Bartoli A, Hostettler A, Marescaux J (2018) Soft-body registration of pre-operative 3D models to intra-operative RGBD partial body scans. In: MICCAI. Springer, pp 39–46
21.
Zurück zum Zitat Plantefeve R, Peterlik I, Haouchine N, Cotin S (2016) Patient-specific biomechanical modeling for guidance during minimally-invasive hepatic surgery. Ann Biomed Eng 44(1):139–153CrossRefPubMed Plantefeve R, Peterlik I, Haouchine N, Cotin S (2016) Patient-specific biomechanical modeling for guidance during minimally-invasive hepatic surgery. Ann Biomed Eng 44(1):139–153CrossRefPubMed
22.
Zurück zum Zitat Rumman NA, Schaerf M, Bechmann D (2015) Collision detection for articulated deformable characters. In: Proceedings of the 8th ACM SIGGRAPH conference on motion in games. ACM, pp 215–220 Rumman NA, Schaerf M, Bechmann D (2015) Collision detection for articulated deformable characters. In: Proceedings of the 8th ACM SIGGRAPH conference on motion in games. ACM, pp 215–220
23.
Zurück zum Zitat Suwelack S, Röhl S, Bodenstedt S, Reichard D, Dillmann R, Santos T, Maier-Hein L, Wagner M, Wünscher J, Kenngott H (2014) Physics-based shape matching for intraoperative image guidance. Med Phys 41(11):111901CrossRefPubMed Suwelack S, Röhl S, Bodenstedt S, Reichard D, Dillmann R, Santos T, Maier-Hein L, Wagner M, Wünscher J, Kenngott H (2014) Physics-based shape matching for intraoperative image guidance. Med Phys 41(11):111901CrossRefPubMed
24.
Zurück zum Zitat Thompson S, Schneider C, Bosi M, Gurusamy K, Ourselin S, Davidson B, Hawkes D, Clarkson MJ (2018) In vivo estimation of target registration errors during augmented reality laparoscopic surgery. CARS 13(6):865–874CrossRef Thompson S, Schneider C, Bosi M, Gurusamy K, Ourselin S, Davidson B, Hawkes D, Clarkson MJ (2018) In vivo estimation of target registration errors during augmented reality laparoscopic surgery. CARS 13(6):865–874CrossRef
25.
Zurück zum Zitat Thompson S, Totz J, Song Y, Johnsen S, Stoyanov D, Ourselin S, Gurusamy K, Schneider C, Davidson B, Hawkes D (2015) Accuracy validation of an image guided laparoscopy system for liver resection. In: Medical imaging 2015—image-guided procedures, robotic interventions, and modeling, vol 9415. SPIE, p 941509 Thompson S, Totz J, Song Y, Johnsen S, Stoyanov D, Ourselin S, Gurusamy K, Schneider C, Davidson B, Hawkes D (2015) Accuracy validation of an image guided laparoscopy system for liver resection. In: Medical imaging 2015—image-guided procedures, robotic interventions, and modeling, vol 9415. SPIE, p 941509
26.
Zurück zum Zitat Zijlmans M, Langø T, Hofstad EF, Van Swol CF, Rethy A (2012) Navigated laparoscopy–liver shift and deformation due to pneumoperitoneum in an animal model. Minim Invasive Ther Allied Technol 21(3):241–248CrossRefPubMed Zijlmans M, Langø T, Hofstad EF, Van Swol CF, Rethy A (2012) Navigated laparoscopy–liver shift and deformation due to pneumoperitoneum in an animal model. Minim Invasive Ther Allied Technol 21(3):241–248CrossRefPubMed
Metadaten
Titel
An in vivo porcine dataset and evaluation methodology to measure soft-body laparoscopic liver registration accuracy with an extended algorithm that handles collisions
verfasst von
Richard Modrzejewski
Toby Collins
Barbara Seeliger
Adrien Bartoli
Alexandre Hostettler
Jacques Marescaux
Publikationsdatum
30.05.2019
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 7/2019
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-019-02001-4

Weitere Artikel der Ausgabe 7/2019

International Journal of Computer Assisted Radiology and Surgery 7/2019 Zur Ausgabe

Update Radiologie