Purpose

Pedicle screw malplacement, leading to neurological symptoms, vascular injury, and premature implant loosening, is not uncommon and difficult to reliably detect intraoperatively with current techniques. We propose a new intraoperative post-placement pedicle screw position assessment system that can therefore allow surgeons to correct breaches during the procedure. Our objectives were to assess the accuracy and robustness of this proposed screw location system and to compare its performance to that of 2D planar radiography.

Methods

The proposed system uses two intraoperative X-ray shots acquired with a standard fluoroscopic C-arm and processed using 2D/3D registration methods to provide a 3D visualization of the vertebra and screw superimposed on one another. Point digitization and CT imaging of the residual screw tunnel were used to assess accuracy in five synthetic lumbar vertebral models (10 screws in total). Additionally, the accuracy was evaluated with and without correcting for image distortion and for various screw lengths, screw materials, breach directions, and vertebral levels.

Results

The proposed method is capable of localizing the implanted screws with less than 2 mm of translational error (RMSE: 0.7 and 0.8 mm for the screw head and tip, respectively) and less than \(2.3^{\circ }\) angular error (RMSE: \(1.3^{\circ }\)), with minimal change to the errors if image distortion is not corrected. Breaches and their anatomical locations were all correctly visualized and identified for a variety of screw lengths, screw materials, breach locations, and vertebral levels, demonstrating the robustness of this approach. In contrast, one breach, one non-breach, and the anatomical location of three screws were misclassified with 2D X-ray.

Conclusion

We have demonstrated an accurate and low-radiation technique for localizing pedicle screws post-implantation that requires only two X-rays. This intraoperative feedback of screw location and direction may allow the surgeon to correct malplaced screws intraoperatively, thereby reducing postoperative complications and reoperation rates.
Literatur
8.
Zurück zum Zitat Dea N, Fisher CG, Batke J, Strelzow J, Mendelsohn D, Paquette SJ, Kwon BK, Boyd MD, Dvorak MF, Street JT (2016) Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis. Spine J 16:23–31. https://doi.org/10.1016/j.spinee.2015.09.062 CrossRefPubMed Dea N, Fisher CG, Batke J, Strelzow J, Mendelsohn D, Paquette SJ, Kwon BK, Boyd MD, Dvorak MF, Street JT (2016) Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis. Spine J 16:23–31. https://​doi.​org/​10.​1016/​j.​spinee.​2015.​09.​062 CrossRefPubMed
20.
21.
Zurück zum Zitat Devlin VJ, Asher MA (2003) Lumbar pedicle fixation. In: Haher TR, Merola AA (eds) Surgical techniques for the spine. Thieme, New York, pp 212–217 Devlin VJ, Asher MA (2003) Lumbar pedicle fixation. In: Haher TR, Merola AA (eds) Surgical techniques for the spine. Thieme, New York, pp 212–217
26.
Zurück zum Zitat Brainerd EL, Baier DB, Gatesy SM, Hedrick TL, Metzger KA, Gilbert SL, Crisco JJ (2010) X-Ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research. J Exp Zool A Ecol Genet Physiol 313:262–279. https://doi.org/10.1002/Jez.589 PubMedCrossRef Brainerd EL, Baier DB, Gatesy SM, Hedrick TL, Metzger KA, Gilbert SL, Crisco JJ (2010) X-Ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research. J Exp Zool A Ecol Genet Physiol 313:262–279. https://​doi.​org/​10.​1002/​Jez.​589 PubMedCrossRef
35.
Zurück zum Zitat Esfandiari H, Anglin C, Street J, Guy P, Hodgson A (2017) A machine learning framework for intraoperative segmentation and quality assessment of pedicle screw X-rays. In: CAOS 2017. 17th annual meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS), vol 1, pp 144–150. https://doi.org/10.29007/x9mr Esfandiari H, Anglin C, Street J, Guy P, Hodgson A (2017) A machine learning framework for intraoperative segmentation and quality assessment of pedicle screw X-rays. In: CAOS 2017. 17th annual meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS), vol 1, pp 144–150. https://​doi.​org/​10.​29007/​x9mr
Metadaten
Titel
An intraoperative fluoroscopic method to accurately measure the post-implantation position of pedicle screws
verfasst von
Robyn Newell
Hooman Esfandiari
Carolyn Anglin
Renee Bernard
John Street
Antony J Hodgson
Publikationsdatum
09.04.2018
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 8/2018
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-018-1732-8

Weitere Artikel der Ausgabe 8/2018

International Journal of Computer Assisted Radiology and Surgery 8/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.