Skip to main content
Erschienen in: Surgical Endoscopy 1/2018

22.06.2017 | New Technology

Application of transoral continuous intraoperative neuromonitoring in natural orifice transluminal endoscopic surgery for thyroid disease: a preliminary study

verfasst von: Han-Kun Chen, Chun-Liang Chen, Kuo-Shan Wen, Yi-Feng Lin, Kai-Yuan Lin, Yih-Huei Uen

Erschienen in: Surgical Endoscopy | Ausgabe 1/2018

Einloggen, um Zugang zu erhalten

Abstract

Background

The novel concept of continuous intraoperative neuromonitoring (Cont-IONM) through stimulation of the vagal nerve has been used in thyroidectomies to prevent imminent injury of the recurrent laryngeal nerve (RLN). This article reports on this technology and the results of using transoral Cont-IONM in natural orifice transluminal endoscopic surgery for thyroid disease.

Methods

Cont-IONM of the RLN was achieved through automatic cyclical stimulation of the vagal nerve using a C2 monitor and delta stimulating electrode. During the operation, three vestibular incisions were made, and the stimulating electrode was transorally inserted, with its cable line lying outside the trocar. The vagal nerve was gently dissected, looped, and then enveloped by the electrode cuff. Electromyography (EMG) of the vocalis muscle was performed, and the alarm was set to activate when the EMG amplitude reduced by 50% and latency was prolonged by 10%. Demographic data and outcome variables, including incremental time required to achieve Cont-IONM, were obtained.

Results

A total of 20 patients (28 nerves at risk) undergoing a transoral endoscopic thyroidectomy vestibular approach were enrolled in this study. All Cont-IONM procedures were successfully completed. In all patients, the stimulation was set at 0.7 milliamps every 1 s, and Cont-IONM use was unassociated with any untoward neural, cardiovascular, or gastrointestinal sequelae. On average, the ipsilateral Cont-IONM procedure required 10.33 ± 2.57 min to complete. Except for one instance, no significant problems occurred with electrode displacement. In one patient, a combined EMG event occurred, which improved after releasing the thyroid retractor, and the patient had no vocal cord paralysis postoperatively.

Conclusion

Cont-IONM is feasible and safe to use during transoral endoscopic thyroidectomies and may assist in the early detection of adverse EMG changes, thereby preventing paralysis of the RLNs.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Randolph GW, Dralle H, Abdullah H, Barczynski M, Bellantone R, Brauckhoff M, Carnaille B, Cherenko S, Chiang FY, Dionigi G, Finck C, Hartl D, Kamani D, Lorenz K, Miccolli P, Mihai R, Miyauchi A, Orloff L, Perrier N, Poveda MD, Romanchishen A, Serpell J, Sitges-Serra A, Sloan T, Van Slycke S, Snyder S, Takami H, Volpi E, Woodson G (2011) Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(Suppl 1):S1–S16CrossRefPubMed Randolph GW, Dralle H, Abdullah H, Barczynski M, Bellantone R, Brauckhoff M, Carnaille B, Cherenko S, Chiang FY, Dionigi G, Finck C, Hartl D, Kamani D, Lorenz K, Miccolli P, Mihai R, Miyauchi A, Orloff L, Perrier N, Poveda MD, Romanchishen A, Serpell J, Sitges-Serra A, Sloan T, Van Slycke S, Snyder S, Takami H, Volpi E, Woodson G (2011) Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope 121(Suppl 1):S1–S16CrossRefPubMed
2.
Zurück zum Zitat Shedd DP, Burget GC (1966) Identification of the recurrent laryngeal nerve. Arch Surg 92:861–864CrossRefPubMed Shedd DP, Burget GC (1966) Identification of the recurrent laryngeal nerve. Arch Surg 92:861–864CrossRefPubMed
3.
Zurück zum Zitat Ghani U, Assad S (2016) Role of intraoperative nerve monitoring during parathyroidectomy to prevent recurrent laryngeal nerve injury. Cureus 8:e880PubMedPubMedCentral Ghani U, Assad S (2016) Role of intraoperative nerve monitoring during parathyroidectomy to prevent recurrent laryngeal nerve injury. Cureus 8:e880PubMedPubMedCentral
4.
Zurück zum Zitat Hermann M, Hellebart C, Freissmuth M (2004) Neuromonitoring in thyroid surgery: prospective evaluation of intraoperative electrophysiological responses for the prediction of recurrent laryngeal nerve injury. Ann Surg 240:9–17CrossRefPubMedPubMedCentral Hermann M, Hellebart C, Freissmuth M (2004) Neuromonitoring in thyroid surgery: prospective evaluation of intraoperative electrophysiological responses for the prediction of recurrent laryngeal nerve injury. Ann Surg 240:9–17CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Caragacianu D, Kamani D, Randolph GW (2013) Intraoperative monitoring: normative range associated with normal postoperative glottic function. Laryngoscope 123:3026–3031CrossRefPubMed Caragacianu D, Kamani D, Randolph GW (2013) Intraoperative monitoring: normative range associated with normal postoperative glottic function. Laryngoscope 123:3026–3031CrossRefPubMed
6.
Zurück zum Zitat Snyder SK, Lairmore TC, Hendricks JC, Roberts JW (2008) Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy. J Am Coll Surg 206:123–130CrossRefPubMed Snyder SK, Lairmore TC, Hendricks JC, Roberts JW (2008) Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy. J Am Coll Surg 206:123–130CrossRefPubMed
7.
Zurück zum Zitat Liu XL, Wu CW, Zhao YS, Wang T, Chen P, Xin JW, Li SJ, Zhang DQ, Zhang G, Fu YT, Zhao LN, Zhou L, Dionigi G, Chiang FY, Sun H (2016) Exclusive real-time monitoring during recurrent laryngeal nerve dissection in conventional monitored thyroidectomy. Kaohsiung J Med Sci 32:135–141CrossRefPubMed Liu XL, Wu CW, Zhao YS, Wang T, Chen P, Xin JW, Li SJ, Zhang DQ, Zhang G, Fu YT, Zhao LN, Zhou L, Dionigi G, Chiang FY, Sun H (2016) Exclusive real-time monitoring during recurrent laryngeal nerve dissection in conventional monitored thyroidectomy. Kaohsiung J Med Sci 32:135–141CrossRefPubMed
8.
Zurück zum Zitat Chiang FY, Lu IC, Chang PY, Sun H, Wang P, Lu XB, Chen HC, Chen HY, Kim HY, Dionigi G, Wu CW (2015) Stimulating dissecting instruments during neuromonitoring of RLN in thyroid surgery. Laryngoscope 125:2832–2837CrossRefPubMed Chiang FY, Lu IC, Chang PY, Sun H, Wang P, Lu XB, Chen HC, Chen HY, Kim HY, Dionigi G, Wu CW (2015) Stimulating dissecting instruments during neuromonitoring of RLN in thyroid surgery. Laryngoscope 125:2832–2837CrossRefPubMed
9.
Zurück zum Zitat Lamade W, Meyding-Lamade U, Buchhold C, Brauer M, Brandner R, Uttenweiler V, Motsch J, Klar E, Herfarth C (2000) First continuous nerve monitoring in thyroid gland surgery. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen 71:551–557CrossRefPubMed Lamade W, Meyding-Lamade U, Buchhold C, Brauer M, Brandner R, Uttenweiler V, Motsch J, Klar E, Herfarth C (2000) First continuous nerve monitoring in thyroid gland surgery. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen 71:551–557CrossRefPubMed
10.
Zurück zum Zitat Lorincz BB, Mockelmann N, Busch CJ, Hezel M, Knecht R (2016) Automatic periodic stimulation of the vagus nerve during single-incision transaxillary robotic thyroidectomy: feasibility, safety, and first cases. Head Neck 38:482–485CrossRefPubMed Lorincz BB, Mockelmann N, Busch CJ, Hezel M, Knecht R (2016) Automatic periodic stimulation of the vagus nerve during single-incision transaxillary robotic thyroidectomy: feasibility, safety, and first cases. Head Neck 38:482–485CrossRefPubMed
11.
Zurück zum Zitat Witzel K, von Rahden BH, Kaminski C, Stein HJ (2008) Transoral access for endoscopic thyroid resection. Surg Endosc 22:1871–1875CrossRefPubMed Witzel K, von Rahden BH, Kaminski C, Stein HJ (2008) Transoral access for endoscopic thyroid resection. Surg Endosc 22:1871–1875CrossRefPubMed
12.
Zurück zum Zitat Anuwong A (2016) Transoral endoscopic thyroidectomy vestibular approach: a series of the first 60 human cases. World J Surg 40:491–497CrossRefPubMed Anuwong A (2016) Transoral endoscopic thyroidectomy vestibular approach: a series of the first 60 human cases. World J Surg 40:491–497CrossRefPubMed
13.
Zurück zum Zitat Chiang FY, Lee KW, Chen HC, Chen HY, Lu IC, Kuo WR, Hsieh MC, Wu CW (2010) Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg 34:223–229CrossRefPubMed Chiang FY, Lee KW, Chen HC, Chen HY, Lu IC, Kuo WR, Hsieh MC, Wu CW (2010) Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World J Surg 34:223–229CrossRefPubMed
14.
Zurück zum Zitat Schneider R, Randolph GW, Sekulla C, Phelan E, Thanh PN, Bucher M, Machens A, Dralle H, Lorenz K (2013) Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury. Head Neck 35:1591–1598CrossRefPubMed Schneider R, Randolph GW, Sekulla C, Phelan E, Thanh PN, Bucher M, Machens A, Dralle H, Lorenz K (2013) Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury. Head Neck 35:1591–1598CrossRefPubMed
15.
Zurück zum Zitat Mattsson P, Hydman J, Svensson M (2015) Recovery of laryngeal function after intraoperative injury to the recurrent laryngeal nerve. Gland Surg 4:27–35PubMedPubMedCentral Mattsson P, Hydman J, Svensson M (2015) Recovery of laryngeal function after intraoperative injury to the recurrent laryngeal nerve. Gland Surg 4:27–35PubMedPubMedCentral
16.
Zurück zum Zitat Paniello RC, Rich JT, Debnath NL (2015) Laryngeal adductor function in experimental models of recurrent laryngeal nerve injury. Laryngoscope 125:E67–E72CrossRefPubMed Paniello RC, Rich JT, Debnath NL (2015) Laryngeal adductor function in experimental models of recurrent laryngeal nerve injury. Laryngoscope 125:E67–E72CrossRefPubMed
17.
Zurück zum Zitat Chiang FY, Lu IC, Kuo WR, Lee KW, Chang NC, Wu CW (2008) The mechanism of recurrent laryngeal nerve injury during thyroid surgery–the application of intraoperative neuromonitoring. Surgery 143:743–749CrossRefPubMed Chiang FY, Lu IC, Kuo WR, Lee KW, Chang NC, Wu CW (2008) The mechanism of recurrent laryngeal nerve injury during thyroid surgery–the application of intraoperative neuromonitoring. Surgery 143:743–749CrossRefPubMed
18.
Zurück zum Zitat Lamade W, Ulmer C, Seimer A, Molnar V, Meyding-Lamade U, Thon KP, Koch KP (2007) A new system for continuous recurrent laryngeal nerve monitoring. Minim Invasive Ther Allied Technol 16:149–154CrossRefPubMed Lamade W, Ulmer C, Seimer A, Molnar V, Meyding-Lamade U, Thon KP, Koch KP (2007) A new system for continuous recurrent laryngeal nerve monitoring. Minim Invasive Ther Allied Technol 16:149–154CrossRefPubMed
19.
Zurück zum Zitat Schneider R, Przybyl J, Pliquett U, Hermann M, Wehner M, Pietsch UC, Konig F, Hauss J, Jonas S, Leinung S (2010) A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve. Am J Surg 199:507–514CrossRefPubMed Schneider R, Przybyl J, Pliquett U, Hermann M, Wehner M, Pietsch UC, Konig F, Hauss J, Jonas S, Leinung S (2010) A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve. Am J Surg 199:507–514CrossRefPubMed
20.
Zurück zum Zitat Lamade W, Ulmer C, Rieber F, Friedrich C, Koch KP, Thon KP (2011) New backstrap vagus electrode for continuous intraoperative neuromonitoring in thyroid surgery. Surg Innov 18:206–213CrossRefPubMed Lamade W, Ulmer C, Rieber F, Friedrich C, Koch KP, Thon KP (2011) New backstrap vagus electrode for continuous intraoperative neuromonitoring in thyroid surgery. Surg Innov 18:206–213CrossRefPubMed
21.
Zurück zum Zitat Lipton RJ, McCaffrey TV, Litchy WJ (1988) Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery. Laryngoscope 98:1292–1296CrossRefPubMed Lipton RJ, McCaffrey TV, Litchy WJ (1988) Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery. Laryngoscope 98:1292–1296CrossRefPubMed
22.
Zurück zum Zitat Dionigi G, Donatini G, Boni L, Rausei S, Rovera F, Tanda ML, Kim HY, Chiang FY, Wu CW, Mangano A, Rulli F, Alesina PF, Dionigi R (2013) Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: a critical appraisal. Int J Surg 11(Suppl 1):S44–S46CrossRefPubMed Dionigi G, Donatini G, Boni L, Rausei S, Rovera F, Tanda ML, Kim HY, Chiang FY, Wu CW, Mangano A, Rulli F, Alesina PF, Dionigi R (2013) Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: a critical appraisal. Int J Surg 11(Suppl 1):S44–S46CrossRefPubMed
23.
Zurück zum Zitat Friedrich C, Ulmer C, Rieber F, Kern E, Kohler A, Schymik K, Thon KP, Lamade W (2012) Safety analysis of vagal nerve stimulation for continuous nerve monitoring during thyroid surgery. Laryngoscope 122:1979–1987CrossRefPubMed Friedrich C, Ulmer C, Rieber F, Kern E, Kohler A, Schymik K, Thon KP, Lamade W (2012) Safety analysis of vagal nerve stimulation for continuous nerve monitoring during thyroid surgery. Laryngoscope 122:1979–1987CrossRefPubMed
Metadaten
Titel
Application of transoral continuous intraoperative neuromonitoring in natural orifice transluminal endoscopic surgery for thyroid disease: a preliminary study
verfasst von
Han-Kun Chen
Chun-Liang Chen
Kuo-Shan Wen
Yi-Feng Lin
Kai-Yuan Lin
Yih-Huei Uen
Publikationsdatum
22.06.2017
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 1/2018
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-017-5656-0

Weitere Artikel der Ausgabe 1/2018

Surgical Endoscopy 1/2018 Zur Ausgabe

Echinokokkose medikamentös behandeln oder operieren?

06.05.2024 DCK 2024 Kongressbericht

Die Therapie von Echinokokkosen sollte immer in spezialisierten Zentren erfolgen. Eine symptomlose Echinokokkose kann – egal ob von Hunde- oder Fuchsbandwurm ausgelöst – konservativ erfolgen. Wenn eine Op. nötig ist, kann es sinnvoll sein, vorher Zysten zu leeren und zu desinfizieren. 

Recycling im OP – möglich, aber teuer

05.05.2024 DCK 2024 Kongressbericht

Auch wenn sich Krankenhäuser nachhaltig und grün geben – sie tragen aktuell erheblich zu den CO2-Emissionen bei und produzieren jede Menge Müll. Ein Pilotprojekt aus Bonn zeigt, dass viele Op.-Abfälle wiederverwertet werden können.

Im OP der Zukunft läuft nichts mehr ohne Kollege Roboter

04.05.2024 DCK 2024 Kongressbericht

Der OP in der Zukunft wird mit weniger Personal auskommen – nicht, weil die Technik das medizinische Fachpersonal verdrängt, sondern weil der Personalmangel es nötig macht.

Wo hapert es noch bei der Umsetzung der POMGAT-Leitlinie?

03.05.2024 DCK 2024 Kongressbericht

Seit November 2023 gibt es evidenzbasierte Empfehlungen zum perioperativen Management bei gastrointestinalen Tumoren (POMGAT) auf S3-Niveau. Vieles wird schon entsprechend der Empfehlungen durchgeführt. Wo es im Alltag noch hapert, zeigt eine Umfrage in einem Klinikverbund.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.