Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 1/2011

01.01.2011 | Original Paper

Atherosclerotic plaque components characterization and macrophage infiltration identification by intravascular ultrasound elastography based on b-mode analysis: validation in vivo

verfasst von: Peng-Fei Zhang, Hai-Jun Su, Mei Zhang, Ji-Fu Li, Chun-Xi Liu, Shi-Fang Ding, Ya Miao, Liang Chen, Xiao-Nan Li, Xin Yi, Yun Zhang

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

Intravascular ultrasound elastography (IVUSE) is a promising imaging technique for early investigation of vulnerable plaques. Compared to radiofrequency signal processing, digital B-mode analysis is simple and of higher portability. However, rare studies have been reported validating the latter technique in vivo. In this study, we developed an IVUSE computer software system involving semi-automatic border delineation and block-matching algorithm and validated the system in vivo. Seven minipigs were fed with atherogenic diet for 40 weeks. For each pig, the endothelium of one side of the renal arteries was denuded at the fifth week. With cross-correlation analysis, Lagrangian strain was calculated from two intravascular ultrasound images acquired in situ. Sixty regions of interests were selected from 35 elastograms matched well with the corresponding histological slices. Plaque types within these regions were classified as fibrous, fibro-fatty or fatty on Masson’s trichrome and Oil-red O staining. Macrophage infiltration was also evaluated with immunohistology. Comparison between the mean strain value of the region of interest and the histological results revealed significant differences in strain values among different plaque types and non-diseased artery walls. The extent of macrophage infiltration was found to be correlated positively with strain values. For identification of fibro-fatty and fibrous plaques and macrophage infiltration, the system showed high sensitivity (93, 96 and 92%, respectively) and specificity (89, 76 and 66%, respectively), as revealed by receiver operating characteristic analysis. Our IVUSE system based on B-mode analysis is capable of characterizing fibrous and fibro-fatty plaques and macrophage intensity, thus holds potential for identifying vulnerable plaque.
Literatur
1.
Zurück zum Zitat Fuster V, Moreno PR, Fayad ZA, Corti R, Badimon JJ (2005) Atherothrombosis and high-risk plaque: part I: evolving concepts. J Am Coll Cardiol 46:937–954CrossRefPubMed Fuster V, Moreno PR, Fayad ZA, Corti R, Badimon JJ (2005) Atherothrombosis and high-risk plaque: part I: evolving concepts. J Am Coll Cardiol 46:937–954CrossRefPubMed
2.
Zurück zum Zitat de Korte CL, Pasterkamp G, van der Steen AF, Woutman HA, Bom N (2000) Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro. Circulation 102:617–623PubMed de Korte CL, Pasterkamp G, van der Steen AF, Woutman HA, Bom N (2000) Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro. Circulation 102:617–623PubMed
3.
Zurück zum Zitat Schaar JA, de Korte CL, Mastik F, Strijder C, Pasterkamp G, Boersma E, Serruys PW, Van der Steen AF (2003) Characterizing vulnerable plaque features with intravascular elastography. Circulation 108:2636–2641CrossRefPubMed Schaar JA, de Korte CL, Mastik F, Strijder C, Pasterkamp G, Boersma E, Serruys PW, Van der Steen AF (2003) Characterizing vulnerable plaque features with intravascular elastography. Circulation 108:2636–2641CrossRefPubMed
4.
Zurück zum Zitat Talhami HE, Wilson LS, Neale ML (1994) Spectral tissue strain: a new technique for imaging tissue strain using intravascular ultrasound. Ultrasound Med Biol 20:759–772CrossRefPubMed Talhami HE, Wilson LS, Neale ML (1994) Spectral tissue strain: a new technique for imaging tissue strain using intravascular ultrasound. Ultrasound Med Biol 20:759–772CrossRefPubMed
5.
Zurück zum Zitat Ryan LK, Foster FS (1997) Ultrasonic measurement of differential displacement and strain in a vascular model. Ultrason Imaging 19:19–38PubMed Ryan LK, Foster FS (1997) Ultrasonic measurement of differential displacement and strain in a vascular model. Ultrason Imaging 19:19–38PubMed
6.
Zurück zum Zitat Hein IA, O’Brien WR (1993) Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review. IEEE Trans Ultrason Ferroelectr Freq Control 40:84–102CrossRefPubMed Hein IA, O’Brien WR (1993) Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review. IEEE Trans Ultrason Ferroelectr Freq Control 40:84–102CrossRefPubMed
7.
Zurück zum Zitat Wan M, Li Y, Li J, Cui Y, Zhou X (2001) Strain imaging and elasticity reconstruction of arteries based on intravascular ultrasound video images. IEEE Trans Biomed Eng 48:116–120CrossRefPubMed Wan M, Li Y, Li J, Cui Y, Zhou X (2001) Strain imaging and elasticity reconstruction of arteries based on intravascular ultrasound video images. IEEE Trans Biomed Eng 48:116–120CrossRefPubMed
8.
Zurück zum Zitat Revell J, Mirmehdi M, McNally D (2005) Computer vision elastography: speckle adaptive motion estimation for elastography using ultrasound sequences. IEEE Trans Med Imaging 24:755–766CrossRefPubMed Revell J, Mirmehdi M, McNally D (2005) Computer vision elastography: speckle adaptive motion estimation for elastography using ultrasound sequences. IEEE Trans Med Imaging 24:755–766CrossRefPubMed
9.
Zurück zum Zitat Shi H, Varghese T (2007) Two-dimensional multi-level strain estimation for discontinuous tissue. Phys Med Biol 52:389–401CrossRefPubMed Shi H, Varghese T (2007) Two-dimensional multi-level strain estimation for discontinuous tissue. Phys Med Biol 52:389–401CrossRefPubMed
10.
Zurück zum Zitat Pellot-Barakat C, Frouin F, Insana MF, Herment AA, Herment A (2004) Ultrasound elastography based on multi scale estimations of regularized displacement fields. IEEE Trans Med Imaging 23:153–163CrossRefPubMed Pellot-Barakat C, Frouin F, Insana MF, Herment AA, Herment A (2004) Ultrasound elastography based on multi scale estimations of regularized displacement fields. IEEE Trans Med Imaging 23:153–163CrossRefPubMed
11.
Zurück zum Zitat Ganzalez RC, Woods RE (2002) Digital image processing, 2nd edn. Prentice Hall, New Jersey Ganzalez RC, Woods RE (2002) Digital image processing, 2nd edn. Prentice Hall, New Jersey
12.
Zurück zum Zitat Lobregt S, Viergever MA (1995) A discrete dynamic contour model. IEEE Trans Med Imaging 14:12–24CrossRefPubMed Lobregt S, Viergever MA (1995) A discrete dynamic contour model. IEEE Trans Med Imaging 14:12–24CrossRefPubMed
13.
Zurück zum Zitat Céspedes EI, de Korte CL, vab der Steen AFW (2000) Intraluminal ultrasonic palpation: assessment of local and cross-sectional tissue stiffness. Ultrasound Med Biol 26:385–396CrossRefPubMed Céspedes EI, de Korte CL, vab der Steen AFW (2000) Intraluminal ultrasonic palpation: assessment of local and cross-sectional tissue stiffness. Ultrasound Med Biol 26:385–396CrossRefPubMed
14.
Zurück zum Zitat Mazzone RW, Kornblau S, Durand CM (1980) Shrinkage of lung after chemical fixation for analysis of pulmonary structure-function relations. J Appl Physiol 48:382–385PubMed Mazzone RW, Kornblau S, Durand CM (1980) Shrinkage of lung after chemical fixation for analysis of pulmonary structure-function relations. J Appl Physiol 48:382–385PubMed
15.
Zurück zum Zitat Dai D, Ding YH, Danielson MA, Kadirvel R, Lewis DA, Cloft HJ, Kallmes DF (2005) Histopathologic and immunohistochemical comparison of human, rabbit, and swine aneurysms embolized with platinum coils. Am J Neuroradiol 26:2560–2568PubMed Dai D, Ding YH, Danielson MA, Kadirvel R, Lewis DA, Cloft HJ, Kallmes DF (2005) Histopathologic and immunohistochemical comparison of human, rabbit, and swine aneurysms embolized with platinum coils. Am J Neuroradiol 26:2560–2568PubMed
16.
Zurück zum Zitat Lin HL, Xu XS, Lu HX, Zhang L, Li CJ, Tang MX, Sun HW, Liu Y, Zhang Y (2007) Pathological mechanisms and dose dependency of erythrocyte-induced vulnerability of atherosclerotic plaque. J Mol Cell Cardiol 43:272–280CrossRefPubMed Lin HL, Xu XS, Lu HX, Zhang L, Li CJ, Tang MX, Sun HW, Liu Y, Zhang Y (2007) Pathological mechanisms and dose dependency of erythrocyte-induced vulnerability of atherosclerotic plaque. J Mol Cell Cardiol 43:272–280CrossRefPubMed
17.
Zurück zum Zitat Malik N, Francis SE, Holt CM, Gunn J, Thomas GL, Shepherd L, Chamberlain J, Newman CMH, Cumberland DC, Crossman DC (1998) Apoptosis and cell proliferation after porcine coronary angioplasty. Circulation 98:1657–1665PubMed Malik N, Francis SE, Holt CM, Gunn J, Thomas GL, Shepherd L, Chamberlain J, Newman CMH, Cumberland DC, Crossman DC (1998) Apoptosis and cell proliferation after porcine coronary angioplasty. Circulation 98:1657–1665PubMed
18.
Zurück zum Zitat Pasterkamp G, Schoneveld AH, van der Wal AC, Haudenschild CC, Clarijs RJ, Becker AE, Hillen B, Borst C (1998) Relation of arterial geometry to luminal narrowing and histological markers for plaque vulnerability: the remodeling paradox. J Am Coll Cardiol 32:655–662CrossRefPubMed Pasterkamp G, Schoneveld AH, van der Wal AC, Haudenschild CC, Clarijs RJ, Becker AE, Hillen B, Borst C (1998) Relation of arterial geometry to luminal narrowing and histological markers for plaque vulnerability: the remodeling paradox. J Am Coll Cardiol 32:655–662CrossRefPubMed
19.
Zurück zum Zitat Fung YC (1993) Biomechanics: mechanical properties of living tissues, 2nd edn. Springer, New York Fung YC (1993) Biomechanics: mechanical properties of living tissues, 2nd edn. Springer, New York
20.
Zurück zum Zitat Chaturvedi P, Insana MF, Hall TJ (1998) Ultrasonic and elasticity imaging to model disease-induced changes in soft-tissue structure. Med Image Anal 2:325–338CrossRefPubMed Chaturvedi P, Insana MF, Hall TJ (1998) Ultrasonic and elasticity imaging to model disease-induced changes in soft-tissue structure. Med Image Anal 2:325–338CrossRefPubMed
21.
Zurück zum Zitat Janssen CRM, de Korte CL, van der Heiden MS, Wapennar CPA, van der Steen AFW (2000) Angle matching in intravascular elastography. Ultrasonics 38:417–423CrossRefPubMed Janssen CRM, de Korte CL, van der Heiden MS, Wapennar CPA, van der Steen AFW (2000) Angle matching in intravascular elastography. Ultrasonics 38:417–423CrossRefPubMed
22.
Zurück zum Zitat Shi H, Chen Q, Varghese T (2005) A general solution for catheter position effects for strain estimation in intravascular ultrasound. Ultrasound Med Biol 31:1509–1526CrossRefPubMed Shi H, Chen Q, Varghese T (2005) A general solution for catheter position effects for strain estimation in intravascular ultrasound. Ultrasound Med Biol 31:1509–1526CrossRefPubMed
23.
Zurück zum Zitat Yueng F, Levinson SF (1998) Feature-adaptive motion tracking of ultrasound image sequences using a deformable mesh. IEEE Trans Med Imaging 17:945–956CrossRef Yueng F, Levinson SF (1998) Feature-adaptive motion tracking of ultrasound image sequences using a deformable mesh. IEEE Trans Med Imaging 17:945–956CrossRef
24.
Zurück zum Zitat de Korte CL, Carlier SG, Mastik F, Doyley MM, van der Steen AFW, Surruys PW, Bom N (2002) Morphological and mechanical information of coronary arteries obtained with intravascular elastography. Eur Heart J 23:405–413CrossRefPubMed de Korte CL, Carlier SG, Mastik F, Doyley MM, van der Steen AFW, Surruys PW, Bom N (2002) Morphological and mechanical information of coronary arteries obtained with intravascular elastography. Eur Heart J 23:405–413CrossRefPubMed
25.
Zurück zum Zitat Kearney PP, Ramo MP, Spencer T, Shaw TRD, Starkey IR, McDicken N, Sutherland GR (1997) A study of quantitative and qualitative impact of catheter shaft angulation in a mechanical intravascular ultrasound system. Ultrasound Med Biol 23:87–93CrossRefPubMed Kearney PP, Ramo MP, Spencer T, Shaw TRD, Starkey IR, McDicken N, Sutherland GR (1997) A study of quantitative and qualitative impact of catheter shaft angulation in a mechanical intravascular ultrasound system. Ultrasound Med Biol 23:87–93CrossRefPubMed
26.
Zurück zum Zitat Band W, Goedhard WJA, Knoop AA (1972) Effects of aging on dynamic viscoelastic properties of the rat’s thoracic aorta. Pflugers Arch 331:357–364CrossRefPubMed Band W, Goedhard WJA, Knoop AA (1972) Effects of aging on dynamic viscoelastic properties of the rat’s thoracic aorta. Pflugers Arch 331:357–364CrossRefPubMed
27.
Zurück zum Zitat de Korte CL, Sierevogel MJ, Mastik F, Strijder C, Schaar JA, Velema E, Pasterkamp G, Serruys PW, van der Steen AF (2002) Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: a Yucatan pig study. Circulation 105:1627–1630CrossRefPubMed de Korte CL, Sierevogel MJ, Mastik F, Strijder C, Schaar JA, Velema E, Pasterkamp G, Serruys PW, van der Steen AF (2002) Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: a Yucatan pig study. Circulation 105:1627–1630CrossRefPubMed
28.
Zurück zum Zitat Hiro T, Leung CY, De Guzman S, Caiozzo VJ, Farvid AR, Karimi H, Helfant RH, Tobis JM (1997) Are soft echoes really soft? Intravascular ultrasound assessment of mechanical properties in human atherosclerotic tissue. Am Heart J 133:1–7CrossRefPubMed Hiro T, Leung CY, De Guzman S, Caiozzo VJ, Farvid AR, Karimi H, Helfant RH, Tobis JM (1997) Are soft echoes really soft? Intravascular ultrasound assessment of mechanical properties in human atherosclerotic tissue. Am Heart J 133:1–7CrossRefPubMed
29.
Zurück zum Zitat Gijsen FJ, Wentzel JJ, Thury A, Mastik F, Schaar JA, Schuurbiers JC, Slager CJ, van der Giessen WJ, de Feyter PJ, van der Steen AF, Serruys PW (2008) Strain distribution over plaques in human coronary arteries relates to shear stress. Am J Physiol Heart Circ Physiol 295:H1608–H1614CrossRefPubMed Gijsen FJ, Wentzel JJ, Thury A, Mastik F, Schaar JA, Schuurbiers JC, Slager CJ, van der Giessen WJ, de Feyter PJ, van der Steen AF, Serruys PW (2008) Strain distribution over plaques in human coronary arteries relates to shear stress. Am J Physiol Heart Circ Physiol 295:H1608–H1614CrossRefPubMed
30.
Zurück zum Zitat Richardson PD, Davies MJ, Born GV (1989) Influence of plaque configuration and stress distribution on fissuring of coronary atherosclerotic plaques. Lancet 2:941–944CrossRefPubMed Richardson PD, Davies MJ, Born GV (1989) Influence of plaque configuration and stress distribution on fissuring of coronary atherosclerotic plaques. Lancet 2:941–944CrossRefPubMed
31.
Zurück zum Zitat Lee RT, Libby P (1997) The unstable atheroma. Arterioscler Thromb Vasc Biol 17:1859–1867PubMed Lee RT, Libby P (1997) The unstable atheroma. Arterioscler Thromb Vasc Biol 17:1859–1867PubMed
32.
Zurück zum Zitat Su HJ, Zhang M, Zhang Y (2004) Mechanical model of vulnerable atherosclerotic plaque rupture. Sci China Ser G 47:452–462CrossRef Su HJ, Zhang M, Zhang Y (2004) Mechanical model of vulnerable atherosclerotic plaque rupture. Sci China Ser G 47:452–462CrossRef
33.
Zurück zum Zitat Van Mieghem CA, Bruining N, Schaar JA, McFadden E, Mollet N, Cademartiri F, Mastik F, Ligthart JM, Granillo GA, Valgimigli M, Sianos G, van der Giessen WJ, Backx B, Morel MA, Van Es GA, Sawyer JD, Kaplow J, Zalewski A, van der Steen AF, de Feyter P, Serruys PW (2005) Rationale and methods of the integrated biomarker and imaging study (IBIS): combining invasive and non-invasive imaging with biomarkers to detect subclinical atherosclerosis and assess coronary lesion biology. Int J Card Imaging 21:425–441CrossRef Van Mieghem CA, Bruining N, Schaar JA, McFadden E, Mollet N, Cademartiri F, Mastik F, Ligthart JM, Granillo GA, Valgimigli M, Sianos G, van der Giessen WJ, Backx B, Morel MA, Van Es GA, Sawyer JD, Kaplow J, Zalewski A, van der Steen AF, de Feyter P, Serruys PW (2005) Rationale and methods of the integrated biomarker and imaging study (IBIS): combining invasive and non-invasive imaging with biomarkers to detect subclinical atherosclerosis and assess coronary lesion biology. Int J Card Imaging 21:425–441CrossRef
34.
Zurück zum Zitat Saijo Y, Tanaka A, Iwamoto T, dos Santos Filho E, Yoshizawa M, Hirosaka A, Kijima M, Akino Y, Hanadate Y, Yambe T (2006) Intravascular two-dimensional tissue strain imaging. Ultrasonics 44:e147–e151CrossRefPubMed Saijo Y, Tanaka A, Iwamoto T, dos Santos Filho E, Yoshizawa M, Hirosaka A, Kijima M, Akino Y, Hanadate Y, Yambe T (2006) Intravascular two-dimensional tissue strain imaging. Ultrasonics 44:e147–e151CrossRefPubMed
Metadaten
Titel
Atherosclerotic plaque components characterization and macrophage infiltration identification by intravascular ultrasound elastography based on b-mode analysis: validation in vivo
verfasst von
Peng-Fei Zhang
Hai-Jun Su
Mei Zhang
Ji-Fu Li
Chun-Xi Liu
Shi-Fang Ding
Ya Miao
Liang Chen
Xiao-Nan Li
Xin Yi
Yun Zhang
Publikationsdatum
01.01.2011
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 1/2011
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-010-9659-3

Weitere Artikel der Ausgabe 1/2011

The International Journal of Cardiovascular Imaging 1/2011 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.