Automated Pediatric Abdominal Effective Diameter Measurements Versus Age-Predicted Body Size for Normalization of CT Dose

verfasst von: Phillip M. Cheng, Linda A. Vachon, Vinay A. Duddalwar

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 6/2013

Einloggen, um Zugang zu erhalten

Abstract

There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged 0.8 to 12.9 years (average 8.0 years, SD = 3.7 years) who had CT abdomen/pelvis exams performed on a Toshiba Aquilion 64 scanner. For this set of patients, age-predicted abdominal effective diameter extrapolated based on data from the International Commission on Radiation Units and Measurements was a relatively poor predictor of measured effective diameter. The mean absolute percentage error between the CTDI normalization coefficient calculated from a manually measured effective diameter and the coefficient determined by age-predicted effective diameter was 12.3 % with respect to a 32 cm phantom (range 0.0–52.8 %, SD 8.7 %) and 12.9 % with respect to a 16 cm phantom (range 0.0–56.4 %, SD 9.2 %). In contrast, there is a close correspondence between the automated and manually measured patient effective diameters, with a mean absolute error of 0.6 cm (error range 0.2–1.3 cm). This correspondence translates into a high degree of correspondence between normalization coefficients determined by automated and manual measurements; the mean absolute percentage error was 2.1 % with respect to a 32 cm phantom (range 0.0–8.1 %, SD = 1.4 %) and 2.3 % with respect to a 16 cm phantom (range 0.0–9.3 %, SD = 1.6 %).
Literatur
1.
Zurück zum Zitat Brody AS, Frush DP, Huda W, Brent RL: Radiation risk to children from computed tomography. Pediatrics 120:677–682, 2007PubMedCrossRef Brody AS, Frush DP, Huda W, Brent RL: Radiation risk to children from computed tomography. Pediatrics 120:677–682, 2007PubMedCrossRef
2.
Zurück zum Zitat Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations: Report of AAPM Task Group 204, American Association of Physicists in Medicine, College Park, MD, 2011 Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations: Report of AAPM Task Group 204, American Association of Physicists in Medicine, College Park, MD, 2011
3.
Zurück zum Zitat Strauss KJ, Goske MJ: Estimated pediatric radiation dose during CT. Pediatr Radiol 41(Suppl 2):472–482, 2011PubMedCrossRef Strauss KJ, Goske MJ: Estimated pediatric radiation dose during CT. Pediatr Radiol 41(Suppl 2):472–482, 2011PubMedCrossRef
4.
Zurück zum Zitat International Commission on Radiation Units and Measurements: Appendix D: reports produced by the Health Protection Agency (HPA) (formerly National Radiological Protection Board, NRPB). J ICRU 5:87–92, 2005CrossRef International Commission on Radiation Units and Measurements: Appendix D: reports produced by the Health Protection Agency (HPA) (formerly National Radiological Protection Board, NRPB). J ICRU 5:87–92, 2005CrossRef
5.
Zurück zum Zitat Kleinman PL, Strauss KJ, Zurakowski D, Buckley KS, Taylor GA: Patient size measured on CT images as a function of age at a tertiary care children’s hospital. AJR Am J Roentgenol 194:1611–1619, 2010PubMedCrossRef Kleinman PL, Strauss KJ, Zurakowski D, Buckley KS, Taylor GA: Patient size measured on CT images as a function of age at a tertiary care children’s hospital. AJR Am J Roentgenol 194:1611–1619, 2010PubMedCrossRef
6.
Zurück zum Zitat Brady SL, Kaufman RA: Investigation of American Association of Physicists in Medicine Report 204 size-specific dose estimates for pediatric CT implementation. Radiology 265:832–840, 2012PubMedCrossRef Brady SL, Kaufman RA: Investigation of American Association of Physicists in Medicine Report 204 size-specific dose estimates for pediatric CT implementation. Radiology 265:832–840, 2012PubMedCrossRef
7.
Zurück zum Zitat Cheng PM: Automated Estimation of Abdominal Effective Diameter for Body Size Normalization of CT Dose. J Digit Imaging 26:406–411, 2013 Cheng PM: Automated Estimation of Abdominal Effective Diameter for Body Size Normalization of CT Dose. J Digit Imaging 26:406–411, 2013
8.
Zurück zum Zitat Ikuta I, Sodickson A, Warden GI, Andriole KP, Khorasani R: Automated body size extraction using CT images to calculate water-equivalent diameter. Society of Imaging Informatics Annual Meeting, Orlando, FL, 2012 Ikuta I, Sodickson A, Warden GI, Andriole KP, Khorasani R: Automated body size extraction using CT images to calculate water-equivalent diameter. Society of Imaging Informatics Annual Meeting, Orlando, FL, 2012
9.
Zurück zum Zitat Wang J, Duan X, Christner JA, Leng S, Yu L, McCollough CH: Attenuation-based estimation of patient size for the purpose of size-specific dose estimation in CT. Part I. Development and validation of methods using the CT image. Med Phys 39:6764–6771, 2012PubMedCrossRef Wang J, Duan X, Christner JA, Leng S, Yu L, McCollough CH: Attenuation-based estimation of patient size for the purpose of size-specific dose estimation in CT. Part I. Development and validation of methods using the CT image. Med Phys 39:6764–6771, 2012PubMedCrossRef
10.
Zurück zum Zitat Wang J, Christner JA, Duan X, Leng S, Yu L, McCollough CH: Attenuation-based estimation of patient size for the purpose of size-specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images. Med Phys 39:6772–6778, 2012PubMedCrossRef Wang J, Christner JA, Duan X, Leng S, Yu L, McCollough CH: Attenuation-based estimation of patient size for the purpose of size-specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images. Med Phys 39:6772–6778, 2012PubMedCrossRef
Metadaten
Titel
Automated Pediatric Abdominal Effective Diameter Measurements Versus Age-Predicted Body Size for Normalization of CT Dose
verfasst von
Phillip M. Cheng
Linda A. Vachon
Vinay A. Duddalwar
Publikationsdatum
01.12.2013
Verlag
Springer US
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 6/2013
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-013-9623-6

Weitere Artikel der Ausgabe 6/2013

Journal of Digital Imaging 6/2013 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.