Abstract

The transcutaneous communication system (TCS) is one of the key technologies for monitoring and controling artificial hearts and other artificial organs in the body. In this study, we have developed a new TCS that uses the human body as a conductive medium. Having no energy conversion from electric currents into electromagnetic waves and light provides energy-saving data transmission with a simple electrical circuit. Each unit of the TCS mainly consists of two electrodes, an amplitude shift keying (ASK) modulator and an ASK demodulator (carrier frequency: 4 and 10 MHz). A resonant frequency of an L-C tank circuit including the capacitance component of the body is tuned into each carrier frequency in order to apply the data current effectively into the body. Performance of the TCS was evaluated by a communication test on the surface of a human body. The TCS was able to transmit 3,315 bytes of data bi-directionally at a transmission rate of 115 kbps from a left wrist to a right forearm, to an abdomen and to a left calf without communication error. The power consumption of each TCS unit was 125 mW with an ASK modulated current of 7 mA (RMS). While further study is required to secure its safety, the TCS promises to be a next-generation transcutaneous communication device.
Literatur
1.
Zurück zum Zitat Hugo KM. External programming. In: Webstar JG, editor. Pacemaker. New York: IEEE Press; 1995. p. 277–89. Hugo KM. External programming. In: Webstar JG, editor. Pacemaker. New York: IEEE Press; 1995. p. 277–89.
2.
Zurück zum Zitat Snyder A, Pae W, Boehmer J, Rosenberg G, Weiss W, Piece W, Thompson J, Levis J, Frank D, Zintak H, Scholl S, Korfer R, El-Banayosy A, Arusoglu L, Fey O, Morshuis M. First clinical trials of a totally implantable destination therapy ventricular assist system. J Cogest Heart Fail Circ Support. 2001;1:185–92. Snyder A, Pae W, Boehmer J, Rosenberg G, Weiss W, Piece W, Thompson J, Levis J, Frank D, Zintak H, Scholl S, Korfer R, El-Banayosy A, Arusoglu L, Fey O, Morshuis M. First clinical trials of a totally implantable destination therapy ventricular assist system. J Cogest Heart Fail Circ Support. 2001;1:185–92.
3.
Zurück zum Zitat Santini M, Ricci RP, Lunati M, Landolina M, Perego GB, Marzegalli M, Schirru M, Belvito C, Brambilla R, Guenzati G, Gilardi S, Valsecchi S. Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes. J Interv Card Electrophysiol. 2009;24:53–61.CrossRefPubMed Santini M, Ricci RP, Lunati M, Landolina M, Perego GB, Marzegalli M, Schirru M, Belvito C, Brambilla R, Guenzati G, Gilardi S, Valsecchi S. Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes. J Interv Card Electrophysiol. 2009;24:53–61.CrossRefPubMed
4.
Zurück zum Zitat Okamoto E, Yamamoto Y, Inoue Y, Makino T, Mitamura Y. Development of bidirectional transcutaneous optical data transmission system for artificial hearts allowing long-distance data communication with low electric power consumption. J Artif Organs. 2005;8:149–53.CrossRefPubMed Okamoto E, Yamamoto Y, Inoue Y, Makino T, Mitamura Y. Development of bidirectional transcutaneous optical data transmission system for artificial hearts allowing long-distance data communication with low electric power consumption. J Artif Organs. 2005;8:149–53.CrossRefPubMed
5.
Zurück zum Zitat Inoue K, Shiba K, Shu E, Koshiji K, Tsukahara K, Oh-uchi T, Masuzawa T, Tatsumi E, Taenaka Y, Takano H. Transcutaneous optical telemetry system with infrared laser diode. ASAIO J. 1998;45:841–4.CrossRef Inoue K, Shiba K, Shu E, Koshiji K, Tsukahara K, Oh-uchi T, Masuzawa T, Tatsumi E, Taenaka Y, Takano H. Transcutaneous optical telemetry system with infrared laser diode. ASAIO J. 1998;45:841–4.CrossRef
6.
Zurück zum Zitat International Commission on Non-Ionizing Radiation Protection (ICNIRP). Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields. Oberschleissheim, Germany; 1997. p. 513–4. International Commission on Non-Ionizing Radiation Protection (ICNIRP). Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields. Oberschleissheim, Germany; 1997. p. 513–4.
7.
Zurück zum Zitat Zimmerman TG. Personal area networks: near-field intra-body communication. IBM Syst J. 1996;35:609–17.CrossRef Zimmerman TG. Personal area networks: near-field intra-body communication. IBM Syst J. 1996;35:609–17.CrossRef
8.
Zurück zum Zitat Zimmerman TG. Personal area networks (PAN); near-field intra-body communication, MS Thesis, MIT Media Laboratory, Cambridge, MA, September 1995. Zimmerman TG. Personal area networks (PAN); near-field intra-body communication, MS Thesis, MIT Media Laboratory, Cambridge, MA, September 1995.
9.
Zurück zum Zitat Handa T, Ike S, Takeda S, Sekiguchi T. A very low-power consumption wireless ECG monitoring system using body as a signal transmission medium. IEEE proceedings of international conference on solid-state sensors and actuators; 1997. p. 1003–6. Handa T, Ike S, Takeda S, Sekiguchi T. A very low-power consumption wireless ECG monitoring system using body as a signal transmission medium. IEEE proceedings of international conference on solid-state sensors and actuators; 1997. p. 1003–6.
10.
Zurück zum Zitat Hachisuka K, Nakata A, Takeda T, Terauchi Y, Shiba K, Sasaki K, Hosaka H, Itao K. Development and performance of an intra-body communication device. IEEE proceedings of the 12th international conference on solid state sensors, actuators and microsystems; 2003. p. 1722–5. Hachisuka K, Nakata A, Takeda T, Terauchi Y, Shiba K, Sasaki K, Hosaka H, Itao K. Development and performance of an intra-body communication device. IEEE proceedings of the 12th international conference on solid state sensors, actuators and microsystems; 2003. p. 1722–5.
11.
Zurück zum Zitat Wegmueller MS, Huclova S, Froehlich J, Oberle M, Felber N, Kuster N, Fichtner W. Galvanic coupling enabling wireless implant communications. IEEE Trans Instrum Meas. 2009;58:2618–25.CrossRef Wegmueller MS, Huclova S, Froehlich J, Oberle M, Felber N, Kuster N, Fichtner W. Galvanic coupling enabling wireless implant communications. IEEE Trans Instrum Meas. 2009;58:2618–25.CrossRef
12.
Zurück zum Zitat Ruiz JA, Shimamoto S. A study on the transmission characteristics of the human body towards broadband intra-body communications. IEEE proceedings of the 9th International Symposium on Consumer Electronics; 2005. p. 99–104. Ruiz JA, Shimamoto S. A study on the transmission characteristics of the human body towards broadband intra-body communications. IEEE proceedings of the 9th International Symposium on Consumer Electronics; 2005. p. 99–104.
13.
Zurück zum Zitat Hachisuka K, Nakata A, Takeda T, Shiba K, Sasaki K, Hosaka H, Itao K. Development of devices for communication through human bodies. Micromechatronics. 2002;46:53–64. (in Japanese). Hachisuka K, Nakata A, Takeda T, Shiba K, Sasaki K, Hosaka H, Itao K. Development of devices for communication through human bodies. Micromechatronics. 2002;46:53–64. (in Japanese).
14.
Zurück zum Zitat Wegmuller MS, Kuhn A, Froehlich J, Oberle M, Felber N, Fichtner W. An attempt to model the human body as a communication channel. IEEE Trans Biomed Eng. 2007;54:1851–7.CrossRef Wegmuller MS, Kuhn A, Froehlich J, Oberle M, Felber N, Fichtner W. An attempt to model the human body as a communication channel. IEEE Trans Biomed Eng. 2007;54:1851–7.CrossRef
15.
Zurück zum Zitat Hachisuka K, Terauchi Y, Kishi Y, Sasaki K, Hirota T, Hosaka H, Fujii K, Takahashi M, Ito K. Simplified circuit modeling and fabrication of intra-body communication devices. Sens Actuators A. 2006;130–131:322–30. Hachisuka K, Terauchi Y, Kishi Y, Sasaki K, Hirota T, Hosaka H, Fujii K, Takahashi M, Ito K. Simplified circuit modeling and fabrication of intra-body communication devices. Sens Actuators A. 2006;130–131:322–30.
16.
Zurück zum Zitat Okamoto E, Iwazawa E, Suzuki S, Fukuoka S, Mitamura Y. Feasibility of a remote monitoring system for implantable LVAD patients using PHS telecommunication technology. J Artif Organs. 2001;4:205–13.CrossRef Okamoto E, Iwazawa E, Suzuki S, Fukuoka S, Mitamura Y. Feasibility of a remote monitoring system for implantable LVAD patients using PHS telecommunication technology. J Artif Organs. 2001;4:205–13.CrossRef
17.
Zurück zum Zitat Okamoto E. Transcutaneous information transmission technology. In: Cooperative Research Committee of Medical Actuation Technology, editor. Current state of medical actuation. IEEJ Technical Report vol. 1122. IEEJ Press; 2008. p. 42–4 (in Japanese). Okamoto E. Transcutaneous information transmission technology. In: Cooperative Research Committee of Medical Actuation Technology, editor. Current state of medical actuation. IEEJ Technical Report vol. 1122. IEEJ Press; 2008. p. 42–4 (in Japanese).
Metadaten
Titel
Basic study of a transcutaneous information transmission system using intra-body communication
verfasst von
Eiji Okamoto
Yusuke Sato
Kazuyuki Seino
Takashi Kiyono
Yoshikuni Kato
Yoshinori Mitamura
Publikationsdatum
01.07.2010
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 2/2010
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-010-0502-3

Weitere Artikel der Ausgabe 2/2010

Journal of Artificial Organs 2/2010 Zur Ausgabe

Echinokokkose medikamentös behandeln oder operieren?

06.05.2024 DCK 2024 Kongressbericht

Die Therapie von Echinokokkosen sollte immer in spezialisierten Zentren erfolgen. Eine symptomlose Echinokokkose kann – egal ob von Hunde- oder Fuchsbandwurm ausgelöst – konservativ erfolgen. Wenn eine Op. nötig ist, kann es sinnvoll sein, vorher Zysten zu leeren und zu desinfizieren. 

Wie sieht der OP der Zukunft aus?

04.05.2024 DCK 2024 Kongressbericht

Der OP in der Zukunft wird mit weniger Personal auskommen – nicht, weil die Technik das medizinische Fachpersonal verdrängt, sondern weil der Personalmangel es nötig macht.

Umsetzung der POMGAT-Leitlinie läuft

03.05.2024 DCK 2024 Kongressbericht

Seit November 2023 gibt es evidenzbasierte Empfehlungen zum perioperativen Management bei gastrointestinalen Tumoren (POMGAT) auf S3-Niveau. Vieles wird schon entsprechend der Empfehlungen durchgeführt. Wo es im Alltag noch hapert, zeigt eine Umfrage in einem Klinikverbund.

Recycling im OP – möglich, aber teuer

02.05.2024 DCK 2024 Kongressbericht

Auch wenn sich Krankenhäuser nachhaltig und grün geben – sie tragen aktuell erheblich zu den CO2-Emissionen bei und produzieren jede Menge Müll. Ein Pilotprojekt aus Bonn zeigt, dass viele Op.-Abfälle wiederverwertet werden können.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.