Cardiac cine CT approaching 1 mSv: implementation and assessment of a 58-ms temporal resolution protocol

verfasst von: Younhee J. Choi, Mark A. Ahlman, Marissa Mallek, Tyler E. Cork, Marcus Y. Chen, David A. Bluemke, Veit Sandfort

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 8/2020

Einloggen, um Zugang zu erhalten

Abstract

Clinical use of cardiac cine CT imaging is limited by high radiation dose and low temporal resolution. To evaluate a low radiation dose, high temporal resolution cardiac cine CT protocol in human cardiac CT and phantom scans. CT scans of a circulating iodine target were reconstructed using the conventional single heartbeat half-scan (HS, approx. 175 ms temporal resolution) and the 3-heartbeat multi-segment (MS, approx. 58 ms) algorithms. Motion artifacts were quantified by the root-mean-square error (RMSE). Low-dose cardiac cine CT scans were performed in 55 subjects at a tube potential of 80 kVp and current of 80 mA. Image quality of HS and MS scans was assessed by blinded reader quality assessment, left ventricular (LV) free wall motion, and LV ejection rate. Motion artifacts in phantom scans were higher in HS than in MS reconstructions (RSME 188 and 117 HU, respectively; p = 0.001). Median radiation dose in human scans was 1.2 mSv. LV late diastolic filling was observed more frequently in MS than in HS images (42 vs. 26 subjects, respectively; p < 0.001). LV free wall systolic motion was more physiologic and had less error in MS than in HS reconstructions (sum-of-squared errors 34 vs. 45 mm2, respectively; p < 0.001), and LV peak ejection rate was higher in MS than in HS reconstructions (166 vs. 152 mL/s, respectively; p < 0.001). Cardiac cine CT imaging is feasible at a low radiation dose of 1.2 mSv. MS reconstruction showed improved imaging of rapid motion in phantom studies and human cardiac CTs.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Amzulescu MS, De Craene M, Langet H, Pasquet A, Vancraeynest D, Pouleur AC, Vanoverschelde JL, Gerber BL (2019) Myocardial strain imaging: review of general principles, validation, and sources of discrepancies. Eur Hear J Cardiovasc Imaging 20:605–619. https://doi.org/10.1093/ehjci/jez041 CrossRef Amzulescu MS, De Craene M, Langet H, Pasquet A, Vancraeynest D, Pouleur AC, Vanoverschelde JL, Gerber BL (2019) Myocardial strain imaging: review of general principles, validation, and sources of discrepancies. Eur Hear J Cardiovasc Imaging 20:605–619. https://​doi.​org/​10.​1093/​ehjci/​jez041 CrossRef
6.
Zurück zum Zitat Han BK, Hlavacek AM, Kay WA, Pham TDN, Grant K, Garberich RF, Lesser JR, Raman SV (2016) Multi-institutional evaluation of the indications and radiation dose of functional cardiovascular computed tomography (CCT) imaging in congenital heart disease. Int J Cardiovasc Imaging 32:339–346. https://doi.org/10.1007/s10554-015-0775-y CrossRefPubMed Han BK, Hlavacek AM, Kay WA, Pham TDN, Grant K, Garberich RF, Lesser JR, Raman SV (2016) Multi-institutional evaluation of the indications and radiation dose of functional cardiovascular computed tomography (CCT) imaging in congenital heart disease. Int J Cardiovasc Imaging 32:339–346. https://​doi.​org/​10.​1007/​s10554-015-0775-y CrossRefPubMed
15.
Zurück zum Zitat Schneider CA, Rasband WS, Eliceiri KW (2012) NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9:671–675CrossRef Schneider CA, Rasband WS, Eliceiri KW (2012) NIH Image to ImageJ: 25 years of image analysis. Nat Methods 9:671–675CrossRef
20.
Zurück zum Zitat Smiseth OA, Torp H, Opdahl A, Haugaa KH, Urheim S (1207b) Myocardial strain imaging: how useful is it in clinical decision making? Eur Heart J 37:1196–1207bCrossRef Smiseth OA, Torp H, Opdahl A, Haugaa KH, Urheim S (1207b) Myocardial strain imaging: how useful is it in clinical decision making? Eur Heart J 37:1196–1207bCrossRef
Metadaten
Titel
Cardiac cine CT approaching 1 mSv: implementation and assessment of a 58-ms temporal resolution protocol
verfasst von
Younhee J. Choi
Mark A. Ahlman
Marissa Mallek
Tyler E. Cork
Marcus Y. Chen
David A. Bluemke
Veit Sandfort
Publikationsdatum
04.05.2020
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 8/2020
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-020-01863-z

Weitere Artikel der Ausgabe 8/2020

The International Journal of Cardiovascular Imaging 8/2020 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.