Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT

verfasst von: David Kuerten, Niklas Plange, Eva Charlotte Koch, Antonis Koutsonas, Peter Walter, Matthias Fuest

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 7/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study is to determine the influence of post-surgical corneal edema on the reliability and reproducibility of central corneal thickness (CCT) measurements by a Scheimpflug camera (Pentacam), ultrasound pachymetry (USP), and anterior-segment spectral-domain optical coherence tomography (AS-OCT).

Methods

Thirty-two patients planned for cataract surgery (n = 16) or vitrectomy (n =  6) were included in a prospective study. The non-surgery eye was used as control. Two investigators acquired two measurements each, with the Pentacam (Oculus, Germany) and the AS-OCT (Heidelberg Engineering, Germany) in a randomized order, followed by USP (Tomey SP-100, Germany). CCT was evaluated using the apex value for Pentacam, the corneal apex cut in AS–OCT and averaging eight single measurements for USP. Coefficients of variation (COV) and intra-class correlation coefficients (ICC) were determined.

Results

Post-surgery corneas showed a thickness of (investigators 1 and 2): Pentacam (615.9 ± 58.02 μm and 615.1 ± 60.17 μm), USP (601.4 ± 63.77 μm and 614.5 ± 70.91 μm), AS-OCT (608.8 ± 65.67 μm and 606.9 ± 64.41 μm) ,with no significant difference (ANOVA p > 0.99). The COVs (investigators 1 and 2) for control eyes were: Pentacam (0.78 ± 0.52 and 0.70 ± 0.76), USP (0.66 ± 0.29 and 0.98 ± 0.44), AS-OCT (0.59 ± 0.61 and 0.59 ± 0.40). The COVs (investigators 1 and 2) for post-surgical eyes were: Pentacam (0.98 ± 1.25 and 0.97 ± 0.73), USP (0.73 ± 0.64 and 1.35 ± 0.85), AS-OCT (1.34 ± 1.57 and 1.19 ± 1.18).The ICC was determined in post-surgery corneas (ICC > 0.96) and control corneas (ICC > 0.95).

Conclusion

USP measurements have the highest user dependence. Post-surgical corneal edema leads to higher intraobserver variability. All methods reached a high level of agreement in CCT determination in edematous as well as healthy corneas.
Literatur
1.
Zurück zum Zitat Gordon MO, Beiser JA, Brandt JD, Heuer DK, Higginbotham EJ, Johnson CA, Keltner JL, Miller JP, Parrish RK 2nd, Wilson MR, Kass MA (2002) The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 120(6):714–720, discussion 829–730PubMedCrossRef Gordon MO, Beiser JA, Brandt JD, Heuer DK, Higginbotham EJ, Johnson CA, Keltner JL, Miller JP, Parrish RK 2nd, Wilson MR, Kass MA (2002) The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 120(6):714–720, discussion 829–730PubMedCrossRef
3.
Zurück zum Zitat Jorge J, Rosado J, Diaz-Rey J, Gonzalez-Meijome J (2013) Central corneal thickness and anterior chamber depth measurement by Sirius((R)) Scheimpflug tomography and ultrasound. Clin Ophthalmol 7:417–422. doi:10.2147/OPTH.S35121 PubMedCentralPubMed Jorge J, Rosado J, Diaz-Rey J, Gonzalez-Meijome J (2013) Central corneal thickness and anterior chamber depth measurement by Sirius((R)) Scheimpflug tomography and ultrasound. Clin Ophthalmol 7:417–422. doi:10.​2147/​OPTH.​S35121 PubMedCentralPubMed
4.
Zurück zum Zitat Martin R, de Juan V, Rodriguez G, Cuadrado R, Fernandez I (2007) Measurement of corneal swelling variations without removal of the contact lens during extended wear. Invest Ophthalmol Vis Sci 48(7):3043–3050. doi:10.1167/iovs.06-1372 PubMedCrossRef Martin R, de Juan V, Rodriguez G, Cuadrado R, Fernandez I (2007) Measurement of corneal swelling variations without removal of the contact lens during extended wear. Invest Ophthalmol Vis Sci 48(7):3043–3050. doi:10.​1167/​iovs.​06-1372 PubMedCrossRef
8.
9.
Zurück zum Zitat Miglior S, Albe E, Guareschi M, Mandelli G, Gomarasca S, Orzalesi N (2004) Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness. Br J Ophthalmol 88(2):174–177PubMedCentralPubMedCrossRef Miglior S, Albe E, Guareschi M, Mandelli G, Gomarasca S, Orzalesi N (2004) Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness. Br J Ophthalmol 88(2):174–177PubMedCentralPubMedCrossRef
11.
Zurück zum Zitat de Sanctis U, Missolungi A, Mutani B, Richiardi L, Grignolo FM (2007) Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry. Am J Ophthalmol 144(5):712–718. doi:10.1016/j.ajo.2007.07.021 PubMedCrossRef de Sanctis U, Missolungi A, Mutani B, Richiardi L, Grignolo FM (2007) Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry. Am J Ophthalmol 144(5):712–718. doi:10.​1016/​j.​ajo.​2007.​07.​021 PubMedCrossRef
14.
Zurück zum Zitat Hiraoka M, Amano S, Oshika T, Kato S, Hori S (2001) Factors contributing to corneal complications after vitrectomy in diabetic patients. Jpn J Ophthalmol 45(5):492–495PubMedCrossRef Hiraoka M, Amano S, Oshika T, Kato S, Hori S (2001) Factors contributing to corneal complications after vitrectomy in diabetic patients. Jpn J Ophthalmol 45(5):492–495PubMedCrossRef
15.
Zurück zum Zitat du Toit R, Vega JA, Fonn D, Simpson T (2003) Diurnal variation of corneal sensitivity and thickness. Cornea 22(3):205–209PubMedCrossRef du Toit R, Vega JA, Fonn D, Simpson T (2003) Diurnal variation of corneal sensitivity and thickness. Cornea 22(3):205–209PubMedCrossRef
16.
Zurück zum Zitat Zadnik K, Mutti DO, Adams AJ (1992) The repeatability of measurement of the ocular components. Invest Ophthalmol Vis Sci 33(7):2325–2333PubMed Zadnik K, Mutti DO, Adams AJ (1992) The repeatability of measurement of the ocular components. Invest Ophthalmol Vis Sci 33(7):2325–2333PubMed
18.
Zurück zum Zitat Li EY, Mohamed S, Leung CK, Rao SK, Cheng AC, Cheung CY, Lam DS (2007) Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography. Ophthalmology 114(10):1842–1847. doi:10.1016/j.ophtha.2007.02.017 PubMedCrossRef Li EY, Mohamed S, Leung CK, Rao SK, Cheng AC, Cheung CY, Lam DS (2007) Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography. Ophthalmology 114(10):1842–1847. doi:10.​1016/​j.​ophtha.​2007.​02.​017 PubMedCrossRef
19.
Zurück zum Zitat Chen S, Huang J, Wen D, Chen W, Huang D, Wang Q (2012) Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry. Acta Ophthalmol 90(5):449–455. doi:10.1111/j.1755-3768.2010.01947 PubMedCrossRef Chen S, Huang J, Wen D, Chen W, Huang D, Wang Q (2012) Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry. Acta Ophthalmol 90(5):449–455. doi:10.​1111/​j.​1755-3768.​2010.​01947 PubMedCrossRef
22.
Zurück zum Zitat Wu W, Wang Y, Xu L (2014) Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes. Graefes Arch Clin Exp Ophthalmol 252(1):91–99. doi:10.1007/s00417-013-2502-5 PubMedCrossRef Wu W, Wang Y, Xu L (2014) Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes. Graefes Arch Clin Exp Ophthalmol 252(1):91–99. doi:10.​1007/​s00417-013-2502-5 PubMedCrossRef
23.
Zurück zum Zitat Pierro L, Conforto E, Resti AG, Lattanzio R (1998) High-frequency ultrasound biomicroscopy versus ultrasound and optical pachymetry for the measurement of corneal thickness. Ophthalmologica 212(1):1–3PubMedCrossRef Pierro L, Conforto E, Resti AG, Lattanzio R (1998) High-frequency ultrasound biomicroscopy versus ultrasound and optical pachymetry for the measurement of corneal thickness. Ophthalmologica 212(1):1–3PubMedCrossRef
24.
Zurück zum Zitat Marsich MW, Bullimore MA (2000) The repeatability of corneal thickness measures. Cornea 19(6):792–795PubMedCrossRef Marsich MW, Bullimore MA (2000) The repeatability of corneal thickness measures. Cornea 19(6):792–795PubMedCrossRef
25.
Zurück zum Zitat Mertz GW (1980) Overnight swelling of the living human cornea. J Am Optom Assoc 51(3):211–214PubMed Mertz GW (1980) Overnight swelling of the living human cornea. J Am Optom Assoc 51(3):211–214PubMed
26.
Zurück zum Zitat Kotecha A, Crabb DP, Spratt A, Garway-Heath DF (2009) The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis. Invest Ophthalmol Vis Sci 50(9):4229–4236. doi:10.1167/iovs.08-2955 PubMedCrossRef Kotecha A, Crabb DP, Spratt A, Garway-Heath DF (2009) The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis. Invest Ophthalmol Vis Sci 50(9):4229–4236. doi:10.​1167/​iovs.​08-2955 PubMedCrossRef
27.
Zurück zum Zitat Wheeler NC, Morantes CM, Kristensen RM, Pettit TH, Lee DA (1992) Reliability coefficients of three corneal pachymeters. Am J Ophthalmol 113(6):645–651PubMedCrossRef Wheeler NC, Morantes CM, Kristensen RM, Pettit TH, Lee DA (1992) Reliability coefficients of three corneal pachymeters. Am J Ophthalmol 113(6):645–651PubMedCrossRef
28.
Zurück zum Zitat Iester M, Telani S, Frezzotti P, Manni G, Uva M, Figus M, Perdicchi A (2012) Differences in central corneal thickness between the paired eyes and the severity of the glaucomatous damage. Eye (Lond) 26(11):1424–1430. doi:10.1038/eye.2012.179 CrossRef Iester M, Telani S, Frezzotti P, Manni G, Uva M, Figus M, Perdicchi A (2012) Differences in central corneal thickness between the paired eyes and the severity of the glaucomatous damage. Eye (Lond) 26(11):1424–1430. doi:10.​1038/​eye.​2012.​179 CrossRef
Metadaten
Titel
Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT
verfasst von
David Kuerten
Niklas Plange
Eva Charlotte Koch
Antonis Koutsonas
Peter Walter
Matthias Fuest
Publikationsdatum
01.07.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 7/2015
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-015-2998-y

Weitere Artikel der Ausgabe 7/2015

Graefe's Archive for Clinical and Experimental Ophthalmology 7/2015 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.